    							CHAPTER 3 NDA-24301
    Pag e 9 4
    Revision 1.0
    7. Switch Setting Sheet
    SWITCH NAME SWITCH SHAPE REMARKS
    MB
    SW01
    SW02
    1234 56 78ON
    1234 56 78ON 
    						
    							NDA-24301 CHAPTER 4
    Page 95
    Revision 1.0
    CHAPTER 4 OFFICE DATA ASSIGNMENT
    This chapter explains the office data assignment for the System. Refer to the “Feature Programming Manual” for
    basic office data assignment for the PBX and other programming for service features. Sections 1 and 2 of this chapter
    provide guidelines to the system data and the programming of ZT and PS office data as a basic data assignment,
    while Section 3 provides information regarding each service data assignment.
    1. BASIC OFFICE DATA ASSIGNMENT (STANDALONE)
    1.1 SYSTEM DATA
    The following data assignment is necessary for activating the Wireless service.
    Note 1:For more detail about the above data, refer to the ASYD command in Chapter 5,Commands.
    Note 2:Do not assign the FPC in a standalone configuration. ASYD-SYS1
    SI30=06
    SI420
    b0: Access code using the Pre-Set dialing
    0/1: Out/In service (Normal Setting=0)
    SI421
    SI422
    SI423:  AUTOMATIC ANNOUNCEMENT-PS OUT OF ZONE disconnection timer
    : No tone connection timer to the called party during the handover
    :  ZT start-up Guard Timer when system initialization is in progress (The timer is designed to 
    have the PS location registration required after being placed Out of Zone): Reserved for future 
    use.
    SI427
    bit4-7:Assign the tone sent to the caller when waiting for the system finding PS.
    Note :Effective since Series 7400 Release 9 software.
    0 = No tone, 1 = SPDT, 2 = RBT, 3 = CWT,
    4 = BT, 5 = ROT, 6 = SST, 7 = SDT, 8 = No tone, 
    9 = SDTT, A = CWRBT, B = No Tone, C = 2DT, D = No Tone, 
    E = MUSIC, F = No tone
    ASYDL-SYS1
    SI513=01 LDM is use
    SI800
    b3: PCN for Tenant
    0/1: Different PCN for Tenant/Same PCN for Tenant 
    						
    							CHAPTER 4 NDA-24301
    Pag e 9 6
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    1.2 ZT OFFICE DATA ASSIGNMENT
     CSINT circuit card can accommodate a maximum of four ZTs.
     Every ZT has three speech channels in the form of 3B+D.
     Each ZT is provided with PHS Community, Calling Area, Group and ZT number, given a maximum
    capacity to have 32 areas while each area has eight groups. One group can house 32 ZTs.
    PHS Community: PHS community having the same SYS-ID is identified by PHS community Number
    (PCN).
    Calling Area:  When a dedicated PS is called, the system is designed to search first for a PS in its
    registered area and if the PS has moved Out of Zone, the PS Location Registration is
    automatically performed in no time just when the dedicated PS has moved to another
    place.
    Group:  Dividing into groups is not presently used.
    NEAX2400 IPX
    CS-INT
    CS-INTCalling Area 1
    PSPS
    PS ZT
    Calling Area 2
    PSPS
    PS ZT
    Calling Area 1
    PSPS
    PS ZT
    PCN=1
    PCN=2 
    						
    							NDA-24301 CHAPTER 4
    Page 97
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    1. ZT Initial Start-Up
    1) ASYD (Assignment of System Data)
    CCIS ISDN function simultaneously becomes valid when the ZT operation is attempted to be in 
    service, as the ZT is regarded as a terminal of the ISDN.
    SYS1
    SI186 
    Note 1
    b6=1 (CCIS function in service)
    SI220 
    Note 1
    b6=0 (ISDN function in service)
    Note 1:ISDN and CCIS data become valid, but where the ISDN and CCIS functions are not to be
    used, optional software concerning ISDN and CCIS is not necessary.
    2) Call LVP Server system
    3) APCNL (Assignment of PHS Community Number Data for Local Data Memory)
    FUNC=1
    PHS Community Number (PCN) Entry
    TN ... PCN
    Note:Do not assign Func=2.
    4) ALVPL (Assignment of LVP Code for Local Data Memory)
    KIND=2
    Assign the SYS-ID Code
     
    5) ALVPL (Assignment of LVP Code for Local Data Memory)
    KIND=1
    Assign the LVP Code
    6) ACSEL (Assignment of Expansion CS/ZT System Data for Local Data Memory)
     PHS Community Number : 1~1024
     Network Number : Only for Roaming Feature
     Additional Area Number : Only for Roaming Feature
     Country Number : 31A (USA) fixed
     Number of PHS-Manager Code : 0 fixed
    7) ACSDL (Assignment of CS/ZT Data for Local Data Memory)
    This command is used to assign the ZT related data including the PHS Community Number, 
    Calling Area No., Group No., ZT No., ZT LENS, ZT KIND.
    When this data assignment is finished, 3B+D channels of the CSINT circuit card start-up.
     PHS Community Number : 1~1024
     Calling Area Number : 1-32
     Group Number : 1-8
     ZT Number : 1-32
     KIND : ZT Kind : Number : 4 (fixed)
     TN : Tenant Number
     LENS : ZT Equipment Number
     START
     END 
    						
    							CHAPTER 4 NDA-24301
    Pag e 9 8
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    2.  Add Operating ZT
    1) Installation of Additional ZT
    2) Call LVP Server system
    3) ALVPL (Assignment of LVP Code for Local Data Memory)
    KIND=1
    Assign the LVP Code
    ACSDL (Assignment of CS/ZT Data for Local Data Memory)
    This command is used to assign the ZT related data including the PHS Community Number, 
    Calling Area No., Group No., ZT No., ZT LENS, ZT KIND.
    When this data assignment is finished, 3B+D channels of the CSINT circuit card start-up.
     PHS Community Number : 1~1024
     Calling Area Number : 1-32
     Group Number : 1-8
     ZT Number : 1-32
     TN : Tenant Number
     LENS : ZT Equipment Number
     START
     END 
    						
    							NDA-24301 CHAPTER 4
    Page 99
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    3. ZT Deletion Procedure
    1) MBCSL (MAKE BUSY of CS/ZT for Local Data Memory)
    2) ACSDL (Assignment of CS/ZT Data for Local Data Memory)
    Delete the ZT Data.
     START
     END 
    						
    							CHAPTER 4 NDA-24301
    Pag e 1 00
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    1.3 PS OFFICE DATA ASSIGNMENT
    Below are explanations about assigning office data by which the PS can be in operation in the Built-in PCS
    system.
    
    The port is automatically occupied for each PS assignment from the bigger numbered port (MG=31,U=3, G=23,
    Level=7) to the smaller. When adding UNIT to the system later, you must concern about the number of assigned
    PS (for example, if 192 PSs are assigned, the biggest numbered UNIT can not be used for the station
    assignment). Conversely, if a station data is assigned against the biggest numbered MG, PS can not be assigned
    to your system.
    1. Initial Start-UP of the PS
    2. Addition of the PS
    1) APSD (Assignment of the PS Operation Data for DM)
    This command assigns the PS operation data including its tenant No., station No., Service Feature 
    Restriction Class (SFC) and the Route Restriction Class (RSC) in consideration of the numbering 
    plan/restriction data.
     TN : Tenant
     PS STN : PS Station Number
     KIND : PS KIND :6 (My Line) or 7 (Sub Line)
     RSC : Route Restriction Class
     SFC : Service Feature Restriction Class
     PS-ID : Max. 9 [DEC]
     PSNO : PS KIND : 2 (13 digits or less [BCD]) fixed
       NO. : Assign the same number as the PS NO. according to PS KIND.
     NWN : Network Number  : Only for Roaming Feature
     ADERA : Additional Area Number  : Only for Roaming Feature
     CTRN : Country Number  : 794 (USA) fixed
     Sub-Sysid : Number of Sub-Sysid  : Not used
    3) ALGSL (Assignment of Telephone Number Data for Local Data Memory)
    Refer to “Office Data Specification Manual”.
    4) APDLL (Download of PS Operation Data for Local Data Memory)
    This command loads the PS operation data to the PS.
     UGN
     PS Telephone Number : Max. 16 Digits
    TYPE=2
     PS No : Max. 13 Digits
     END
     START 
    						
    							NDA-24301 CHAPTER 4
    Page 101
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    3. Deletion of the PS data
    1) ALGSL (Assignment of Telephone Number Data for Local Data Memory)
    Delete the related Telephone Number and LENS.
    2) APSD (Assignment of the PS Operation Data for DM)
    Using this command, delete the PS data to be cleared such as tenant No., station No., SFC and 
    RSC.
     END
     START 
    						
    							CHAPTER 4 NDA-24301
    Pag e 1 02
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    2. BASIC OFFICE DATA ASSIGNMENT (FUSION)
    2.1 SYSTEM DATA
    The following data assignment is necessary for activating the PCS service.
    Note:For more detail about the above data, refer to the ASYD command in Chapter 5. ASYD-SYS1
    SI30=06
    SI420
    b0: Access code using the Pre-Set dialing
    0/1: Out/In service (Normal Setting=0)
    SI421
    SI422
    SI423:  AUTOMATIC ANNOUNCEMENT-PS OUT OF ZONE disconnection timer
    : No tone connection timer to the called party during the handover
    :  ZT start-up Guard Timer when system initialization is in progress (The timer is designed to 
    have the PS location registration required after being placed Out of Zone): Reserved for 
    future use.
    SI427
    bit4-7: Assign the tone sent to the caller when waiting for the system finding PS.
    Available since Release 9 software.
    0 = No tone, 1 = SPDT, 2 = RBT, 3 = CWT,
    4 = BT, 5 = ROT, 6 = SST, 7 = SDT, 8 = No tone, 
    9 = SDTT, A = CWRBT, B = No Tone, C = 2DT, D = No Tone, 
    E = MUSIC, F = No tone
    ASYDL-SYS1
    SI512=01 ~ FD : FPC
    SI513=01 LDM is used
    SI514=01 NDM is used
    SI800
    b3: PCN for Tenant
    0/1: a Tenant basis/Common 
    						
    							NDA-24301 CHAPTER 4
    Page 103
    Revision 1.0
    OFFICE DATA ASSIGNMENT
    2.2 ZT OFFICE DATA ASSIGNMENT
     CSINT circuit card can accommodate a maximum of four ZTs.
     Every ZT has three speech channels in the form of 3B+D.
     Each ZT is provided with PHS Community, Calling Area, Group and ZT number, given a maximum
    capacity to have 32 areas while each area has eight groups. One group can house 32 ZTs.
    PHS Community: PHS community having the same SYS-ID is identified by PHS community Number
    (PCN).
    Calling Area:  When a dedicated PS is called, the system is designed to search first for a PS in its
    registered area and if the PS has moved Out of Zone, the PS Location Registration is
    automatically performed in no time just when the dedicated PS has moved to another
    place.
    One area cannot exist in multiple node.
    Group:  Dividing into groups is not presently used.
    NEAX2400 IPX
    CS-INT
    CS-INTCalling Area 1
    PSPS
    PS ZT
    Calling Area 2
    PSPS
    PS ZT
    Calling Area 1
    PSPS
    PS ZT PCN=1
    PCN=2
    NEAX2400 IPX
    CS-INT
    CS-INTCalling Area 2
    PSPS
    PS ZT
    Calling Area 3
    PSPS
    PS ZT
    Calling Area 3
    PSPS
    PS ZT PCN=2
    PCN=1
    FCCS 
    						
    All NEC manuals Comments (0)