CHAPTER 4 NDA-24301 Pag e 1 14 Revision 1.0 OFFICE DATA ASSIGNMENT 5) ARRC (Alternative Route Restriction Pattern Data) Allow the restriction between the external trunk and the announcement trunk. ICRT : Incoming Route Number OGRT : Outgoing Route Number (Announcement trunk) ARI-D_RES = 1 (Tandem Connection without an operator/station assistance is allowed) 6) AAED (Announcement Equipment Data) Assign EQP=60 for the AUTOMATIC ANNOUNCEMENT-PS OUT OF ZONE TN : Tenant Number EQP = 60 (AUTOMATIC ANNOUNCEMENT-PS OUT OF ZONE) C : Duration of Connection R : Sending RBT A : 1 (Answer Signal Sending) M : 1 (Multiple Connection) END A

NDA-24301 CHAPTER 4 Page 115 Revision 1.0 OFFICE DATA ASSIGNMENT 4-2 C.F.-PS Incoming Incomplete Entry Procedures 1) ASYD (Assignment for System Data) Assign whether to use a same access code for Call Forwarding-Busy Line, Call Forwarding-Don’t Answer and C.F.-PS Incoming Incomplete, or use separate access codes. SYS1, INDEX5, bit 0 0=Same 1=Separate 2) ANPD (Numbering Plan Data) Assign the necessary number of digits needed to determine the service which is required according to the first digit received. 3) ASPA (Special Access Code Data) Assign the Special Access Code for the C.F.-PS INCOMING INCOMPLETE CI=N SRV=SSCA SIDA=101 (C.F.-PS INCOMING INCOMPLETE: Set) CI=N SRV=SSCA SIDA=102 (C.F.-PS INCOMING INCOMPLETE: Cancel) 4) ASFC (Service Feature Class Data) Allow the C.F.-PS INCOMING INCOMPLETE according to PS Service Feature Class. SFI=147 (C.F.-INCOMING INCOMPLETE) RES=1 (Allowed) END START

CHAPTER 4 NDA-24301 Pag e 1 16 Revision 1.0 OFFICE DATA ASSIGNMENT AUTOMATIC ANNOUNCEMENT-DISCONNECTED PS OUT OF ZONE 1. GENERAL DESCRIPTION When a PS user moves Out of Zone (out of the PCS service area) and the call is disconnected, the counterpart hears the announcement stating the call was disconnected due to the the wireless user going Out of Zone. 2. OPERATING PROCEDURE No manual operation 3. SERVICE CONDITIONS 1. This service is valid only in a two-party call. This service cannot be used when a call is placed on hold or conference calling participated in by three-party or more is in progress. 2. Digital Announcement Trunk (DAT) circuit card can be used as an announcement trunk. 3. PS user encounters BT when the announcement trunk, when used as single connection (M=0 in the command AAED) and all the trunks are used. 4. AUTOMATIC ANNOUNCEMENT-DISCONNECTED PS OUT OF ZONE is not applied when calls are in progress via a COT line or Attendant Console. A C.O. line subscriber hears ROT and a caller via the Attendant Console encounters BT. 5. In the Fusion Network, every node must have one or more announcement trunks.

NDA-24301 CHAPTER 4 Page 117 Revision 1.0 OFFICE DATA ASSIGNMENT 4. PROGRAMMING Entry Procedures 1) ARTD (Route Class Data) Assign the Route Class Data of the announcement trunk. RT : Route Number OSGS (CDN: 1) = 2 ONSG (CDN: 2)= 2 TF (CDN: 5) = 1 TCL (CDN: 6) = 4 L/T (CDN: 7) = 1 ANS (CDN: 28) = 1 Assign “0” for other data. 2) ALRTN (Assignment of Logical RT in Network Data Memory) LGRT : Logical Route Number FPC : Fusion Point Code RT : Route Number Note:Not necessary in a standalone type. 3) ATRK (Trunk Data) Assign the LENS of the announcement trunk. RT : Route Number TK : Trunk Number LENS : Line Equipment Numbers TN : Tenant Number START A

CHAPTER 4 NDA-24301 Pag e 1 18 Revision 1.0 OFFICE DATA ASSIGNMENT 3) MBTK (Make Busy of Trunk) Set the announcement trunk in a make-busy cancel state 4) ARSC (Route Restriction Class Data) Assign the Route Restriction Class of the station which allows access to the announcement trunk. D/N : Day/Night Mode TN : Tenant Number RT : Route Number RSC : Route Restriction Class (0-15) RRI : Route Restriction Index (0-3) RES = 1 (Allowed) 5) ARRC (Alternative Route Restriction Pattern Data) Allow the connection between an external trunk and the announcement trunk. ICRT : Incoming Route Number OGRT: Outgoing Route Number (Announcement trunk) ARI-D_RES = 1 (Tandem Connection without an operator/station assistance is allowed) 6) AAED (Announcement Equipment Data) Assign EQP=61 for AUTOMATIC ANNOUNCEMENT-DISCONNECTED PS OUT OF ZONE. TN : Tenant Number EQP = 61 (AUTOMATIC ANNOUNCEMENT-DISCONNECTED PS OUT OF ZONE) C : Duration of Connection R : Sending RBT A : 1 (Answer Signal Sending) M : 1(Multiple Connection) END A

NDA-24301 CHAPTER 4 Page 119 Revision 1.0 OFFICE DATA ASSIGNMENT NAME DISPLAY 1. GENERAL DESCRIPTION This feature allows a PS to indicate the user information corresponding to the calling station number while engaged in a station-to-station call. 2. OPERATING PROCEDURE Examples of LCD display are shown below. When originating a station-to-station call: LCD display of the calling station: LCD display of the called station: When a station call has been transferred to another station by Call Forwarding-All Calls/Busy Line/Don’t Answer/PS-Incoming Incomplete: LCD display of the calling station: LCD display of the called station: H . T A R O D I R S P D L N R M . T A R O D I R S P D L N R C F : H . T A R O D I R S P D L N R C F : M . T A R O D I R S P D L N R

CHAPTER 4 NDA-24301 Pag e 1 20 Revision 1.0 OFFICE DATA ASSIGNMENT 3. SERVICE CONDITIONS 1. This feature is available for Series 7300 or later software. 2. User information corresponding to the station number that can be displayed on the LCD is a maximum of 16 digits. 3. User information is displayed on the LCD, intended to the left. The information may consist of upper case letters, numeric characters, and most keyboard symbols. 4. When user information is 12 digits or more, the first or last part of information can be displayed by key operation (Refer to the User Guide of PS). 5. This service and NAME DISPLAY service by Open Application Interface (OAI) cannot be activated concurrently. 6. This service and NAME DISPLAY service for D terms can be activated concurrently. 7. 8-digit display or 16-digit display is selectable by System Data, but cannot be used concurrently. 8. If the PS station has no name programmed for NAME DISPLAY service, the station number is displayed in the name field. 9. NAME DISPLAY is available for the following services: Station-to-station connection Call Forwarding-All Calls/Busy Line/Don’t Answer/PS-Incoming Incomplete Call Waiting Call Transfer 10. MEM_HDD, HDD_FDD and HDD_MAT commands can be used for saving, loading and verifying Name Display data. For detailed information, refer to System Operation and Maintenance Manual.

NDA-24301 CHAPTER 4 Page 121 Revision 1.0 OFFICE DATA ASSIGNMENT 4. PROGRAMMING 1) ASYD (Assignment of System Data) SYS1 SI 78 b5: 1 (Name Display In Service) SI 79 b6: 0 (OAI In Service) SI 241 b1: The number of digits displayed in NAME DISPLAY service 0/1: 8 digits/16 digits 2) ANDD (Assignment of Name Display Data) Assign user’s information to Physical Station Number. TN : Tenant Number STN : Physical Station Number NAME : User information (Maximum 16 digits) END START

CHAPTER 4 NDA-24301 Pag e 1 22 Revision 1.0 OFFICE DATA ASSIGNMENT NAME DISPLAY - CCIS 1. GENERAL DESCRIPTION In between CCIS nodes, this feature allows calling or called party information to be displayed on the LCD of a PS. 2. OPERATING PROCEDURE Examples of LCD display are shown below. When originating a call: LCD display of the calling station: LCD display of the called station: When a call has been transferred to another station by Call Forwarding-All Calls/Busy Line/Don’t Answer/ PS-Incoming Incomplete: LCD display of the calling station: LCD display of the called station: H . T A R O D I R S P D L N R M . T A R O D I R S P D L N R H . T A R O D I R S P D L N R C F : M . T A R O D I R S P D L N R

NDA-24301 CHAPTER 4 Page 123 Revision 1.0 OFFICE DATA ASSIGNMENT 3. SERVICE CONDITIONS 1. This feature is available for Series 7300 or later software. 2. User information corresponding to the station number that can be displayed on the LCD is a maximum of 16 digits. 3. User information is displayed on the LCD, intended to the left. The information may consist of upper case letters, numeric characters, and most keyboard symbols. 4. When user information is 12 digits or more, the first or last part of information can be displayed by the key operation (Refer to the User Guide of PS). 5. This service and NAME DISPLAY service by Open Application Interface (OAI) cannot be activated concurrently. 6. This service and NAME DISPLAY service for D terms can be activated concurrently. 7. Either an 8-digit display or 16-digit display is selectable by System Data, but they cannot be used concurrently. 8. If the PS station has no name programmed for NAME DISPLAY - CCIS service, “Office Code + Station Number” is displayed in the name field. 9. NAME DISPLAY - CCIS is available for the following services: Tie line connection Call Forwarding-All Calls/Busy Line/Don’t Answer/PS-Incoming Incomplete-CCIS Call Waiting Call Transfer 10. When the parameter CI of ARTD command is set to “1” (Information transfer from ISDN line to CCIS line is available), if Low layer compatibility and/or Calling party subaddress information elements are included in a SETUP message from a PS, user information cannot be included in the IAI message. In this case, user information from the PS is not displayed on the called station (PS or D term). 11. MEM_HDD, HDD_FDD and HDD_MAT commands can be used for saving, loading and verifying Name Display data. For detailed information, refer to System Operation and Maintenance Manual.