    							CHAPTER 5 NDA-24301
    Pag e 2 54
    Revision 1.0
    ASYD  : Assignment of System Data
    1. GENERAL
    The ASYD/ASYDL command is used to assign the system data of the following node;
    Local Node (LN) / Network Control Node (NCN) of the Fusion network.
    Stand alone PBX.
    List Up Command: LSYD
    2. PRECAUTIONS
    This part describes only the contents of the command added in Built-in PCS system. For more details, refer to
    the “Office Data Specification.” 
    						
    							NDA-24301 CHAPTER 5
    Page 255
    Revision 1.0
    3. DATA ENTRY INSTRUCTIONS
    Define each bit corresponding
    data with referring to the
    SYSTEM DATA CONTENTS
    SYSTEM
    DATA
    TYPE
    ( SYS )DATA
    ( DATA )
    00-FF
    ( Hex ) SYSTEM
    DATA
    INDEX
    ( INDEX )
    0 - 511
    BIT CORRE-
    SPONDING
    DATA
    DATA
    0 / 1BITSYSTEM DATA CONTENTS
    DATA
    DATA BIT
    BIT
    DATA
    Hex 1
    1b0
    b1
    b2
    b3
    b4
    b5
    b6
    b7 1
    0
    0
    0
    0
    0
    0n
    n+1 FF031
    1
    0
    0
    0
    0
    0
    0b0
    b1
    b2 Not used
    Not used
    Not used
    Not used
    Not used
    Not used
    Number of zzz b3
    b4
    b5
    b6
    b7xxx service 0/1=Not to be provided/  To be provided
    yyy service 0/1=Not to be provided/  To be provided
    Convert from Binary DATA
    to Hexadecimal, and enter the
    Hex. value at DATA text box.
    00000011 b7 b6 b5 b4 b3 b2 b1 b0
    03 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 56
    Revision 1.0
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA  
    INDEX 
    (INDEX)
    0 - 511DATA 
    (DATA) 
    00-FF 
    (Hex)BIT CORRE-
    SPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT
    15b
    0
    Access Code for C.F.-Busy Line and C.F. – Don’t Answer Services
    0/1 = Same/Separate
    Note 1:If a PCS system, C.F.-PS Incoming Call Incomplete also
    refers to this system data.
    Note 2:If “0” is assigned, assign either SID: 10 or 12 in
    command “ASPA”.
    b
    1Maximum number of Multiple Call Forwarding – All Calls/Busy 
    Line occurrences:
    Note:This data is valid when SYS-1, INDEX 69, bit 7 is assigned
    as “1”. b
    2
    b3
    b4Miscellaneous Timer Counter 
    (MTC)
    (0-7)Call Back – Delay Timer
    Timer Value Setting is MTC × 2 
    sec.
    When this data is “000”, Timer 
    value is 2 sec. b
    5
    b6
    b7Call Back – Delay Timer
    0/1 = Ineffective/Effective
    b3b2b1b3b2b1
    000: 100:
    001: 101:
    010: 110:
    011:111:
    once
    three times twice
    five times four times 
    						
    							NDA-24301 CHAPTER 5
    Page 257
    Revision 1.0
    4. SYSTEM DATA PROGRAMMING SHEET (1)
    S
    Y
    S
    1
    SYSTEM
    DATA
    INDEX
    0-511DATA
    00-FFB
    I
    TSYSTEM DATA CONTENTS
    30 060 Mounting Capacity of Data Memory (DM) : 1~63 Mbyte (01~3F) 
    Normally assigned as “6” 
    1
    2
    3
    4
    5
    6
    7
    4200Access code using Pre-set dialing
     (e.g.: Special Access Code + Station number)
    0/1 : Out/In service
    1By cancelling C.F.-PS INCOMING INCOMPLETE
    0 = C.F.-DROPPED CALL is also cancelled
    1 = C.F.-DROPPED CALL is not cancelled
    2Not used
    3
    4
    5
    6
    7
    b7 b6 b5 b4 b3 b2 b1 b0
    00
    Data
    b7 b6 b5 b4 b3 b2 b1 b0
    0000000
    Data 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 58
    Revision 1.0
    S
    Y
    S
    1
    SYSTEM
    DATA
    INDEX
    0-511DATA
    00-FFB
    I
    TSYSTEM DATA CONTENTS
    4210 Miscellaneous Time Counter (MTC) is 
    to be assigned a value from 1 Hex to F 
    Hex.1) Announcement PS-Out of 
    Zone disconnection timer 
    (Release Guard timer)
    Timer value setting is as 
    follows: (TC) sec. × (MTC)
    When the data is assigned as 
    00, the default data is 30 sec. 1
    2
    3
    4 Timer class (TC)
    0 : –  3 : 2 sec.  6 : –
    1 : – 4 : – 7 : –
    2 : –  5 : – 5
    6
    7 Not used
    4220Miscellaneous Time Counter (MTC) is 
    to be assigned a value from 1 Hex to F 
    Hex.2) No-tone connection timer to 
    the called party during the 
    handover
    Timer value setting is as 
    follows: 800 msec.+ (TC) × 
    (MTC)
    When the data is assigned as 
    00, the default data is 800 
    msec. 1
    2
    3
    4Timer class (TC)
    0 : –  3 : –  6 : –
    1 : 64 msec. 4 : –  7 : –
    2 : –  5 : – 5
    6
    7Not used
    4230 Miscellaneous Time Counter (MTC) is 
    to be assigned a value from 1 Hex to F 
    Hex.3) ZT start-up Guard Timer 
    when initialization is in 
    progress.
    (This is the timer by which 
    the ZT is placed out of Zone 
    and made send PS location 
    registration.)
    Timer value setting is as 
    follows: (TC) sec.× (MTC)
    When the data is assigned as 
    00, the default data is 60 sec. 1
    2
    3
    4 Timer class (TC)
    0 : –  3 : 2 sec.  6 : –
    1 : – 4 : 30 sec. 7 : –
    2 : –  5 : – 5
    6
    7Not used
    b7 b6 b5 b4 b3 b2 b1 b0
    0
    b7 b6 b5 b4 b3 b2 b1 b0
    0
    b7 b6 b5 b4 b3 b2 b1 b0
    0 
    						
    							NDA-24301 CHAPTER 5
    Page 259
    Revision 1.0
    AAED  : Assignment of Announcement Equipment Data
    1. GENERAL
    This command is used to assign the trunk information related to Announcement Equipment on a tenant basis. 
    List Up Command: LAED
    2. PRECAUTIONS
    This part describes only the contents of the command added in PCS system. For more details, refer to the “Office
    Data Specification”. 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 60
    Revision 1.0
    3. DATA ENTRY INSTRUCTIONS
    0 = Common 1 = Japanese
    2 = English     3 = German
    4 = French      5 = Spanish
    6 = Chinese     7 = Russian
    8-15 = Spare 
    Note: LANG is available for the
    Hotel application.
    LANG
    Enter EQP as the service feature provided by DAT. 
    0 ~ 59     :
    60       : ANNOUNCEMENT-PS-OUT OF ZONE
    61      : AUTOMATIC ANNOUNCEMENT-PS-OUT OF ZONE CALL
    62 ~ 127 :EQP
    0 = Single connection
    1 = Multiple connection M
    TK parameter appears
    if M=1 is entered. TK
    0 = 30 seconds, and then disconnects
    1 = The connection is held until the calling party released 
    C
    TENANT
    NUMBER
    ( TN )ANNOUNCEMENT
    EQUIPMENT
    NUMBER
    ( EQP ) 0 - 127 KIND OF
    LANGUAGE
    ( LANG )
    0 - 15DURATION OF
    CONNECTION
    ( C )
    0 / 1SENDING
    RBT
    ( R )
    0 / 1ANSWER
    SIGNAL
    SENDING
    ( A )
    0 / 1MULTIPLE
    CONNECTION
    ( M )
    0 / 1ROUTE
    NUMBER
    ( RT )TRUNK
    NUMBER
    ( TK )
    Enter DAT route number assigned
    by the ATRK command. RT
    0 = Send RBT
    1 = Do not send RBT 
    R
    0 = Answer Signal is not sent
    1 = Answer Signal is sent 
    A
    Note:  Regarding this data, refer to the Office Data Specification.  Note   Note 
    						
    							NDA-24301 CHAPTER 5
    Page 261
    Revision 1.0
    4. DATA SHEET
    Note:Parameter LANG is available for the Hotel System.
    TENANT 
    NUMBER
    (TN)ANNOUNCE
    -MENT
    EQUIPMENT
    NUMBER
    (EQP) 0-127KIND OFLANGUAGE
    (LANG)
    0-15
    Note 
    DURATION 
    OF 
    CONNEC-
    TION (C)
    0/1SENDING
    RBT (R)
    0/1ANSWER
    SIGNAL
    SENDING
    (A) 0/1MULTIPLE
    CONNEC-
    TION
    (M)0/1ROUTE
    NUMBER
    (RT)TRUNK
    NUMBER
    (TK)REMARKS 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 62
    Revision 1.0
    ALGSL  : Assignment of Telephone Number Data for LDM
    1. GENERAL
    This command is used to assign the data pertaining to the relationship between the Telephone Number (TELN)
    and physical station. 
    List Up Command : LLGSL
    2. PRECAUTIONS
    1. This Telephone Number can be used in the self (local) node only. Use the ALGSN command if the
    Telephone Number for the Fusion network is required.
    2. TYPE parameter designates the programming method of physical station (the result is the same whichever
    selected). When TYPE = 1 (LENS) is selected, the physical station which accommodates the Telephone
    Number (TELN) is specified by the LENS. Likewise, TYPE = 2 (STN) is selected, the physical station
    number (STN) is used.
    3. The system data assignment (ASYDL, SYS1, INDEX513 Data 01hex) is needed to provide the Local Data
    Memory (LDM).
    4. The applicable tenant number (TN) range is designated by the ASYD command, SYS1, INDEX8.
    5. When deleting the telephone number, the user must first delete the data which is concerned with Group
    Calling Conference. 
    						
    							NDA-24301 CHAPTER 5
    Page 263
    Revision 1.0
    3. DATA ENTRY INSTRUCTIONS
      TYPE = 1 (LENS is used to specify the Telephone number.)
      TYPE = 2 (STN is used to specify the Telephone number.)
    TELEPHONE NUMBER
     (TELN) MAX. 16 DIGITSLINE EQUIPMENT NUMBER USER GROUP
    NUMBER
    (UGN)
    UGN TYPE
     1 = User Group Number 1 (Fixed)
    LENS
    LENS of the physical stationTYPE
    1 = LENS is used to specify the Telephone number
    2 = STN is used to specify the Telephone number
    1
    1 1
    1
    (LENS)
    11
    TELN
    Telephone number assigned by the 
    ALGNL command
    TELEPHONE NUMBER
     (TELN) MAX. 16 DIGITSSTATION
    NUMBER
    (STN) TENANT
    NUMBER
    (TN) USER GROUP
    NUMBER
    (UGN)
    UGN TYPE
     1 = User Group Number 1 (Fixed)
    STN
    Station number of the 
    physical stationTYPE
    1 = LENS is used to specify the Telephone number
    2 = STN is used to specify the Telephone number
    1
    1 2
    2
    TN
    Tenant number of  the physical station
    TELN
     Telephone number assigned by the ALGNL command 
    						