CHAPTER 5 NDA-24301 Pag e 2 54 Revision 1.0 ASYD : Assignment of System Data 1. GENERAL The ASYD/ASYDL command is used to assign the system data of the following node; Local Node (LN) / Network Control Node (NCN) of the Fusion network. Stand alone PBX. List Up Command: LSYD 2. PRECAUTIONS This part describes only the contents of the command added in Built-in PCS system. For more details, refer to the “Office Data Specification.”

NDA-24301 CHAPTER 5 Page 255 Revision 1.0 3. DATA ENTRY INSTRUCTIONS Define each bit corresponding data with referring to the SYSTEM DATA CONTENTS SYSTEM DATA TYPE ( SYS )DATA ( DATA ) 00-FF ( Hex ) SYSTEM DATA INDEX ( INDEX ) 0 - 511 BIT CORRE- SPONDING DATA DATA 0 / 1BITSYSTEM DATA CONTENTS DATA DATA BIT BIT DATA Hex 1 1b0 b1 b2 b3 b4 b5 b6 b7 1 0 0 0 0 0 0n n+1 FF031 1 0 0 0 0 0 0b0 b1 b2 Not used Not used Not used Not used Not used Not used Number of zzz b3 b4 b5 b6 b7xxx service 0/1=Not to be provided/ To be provided yyy service 0/1=Not to be provided/ To be provided Convert from Binary DATA to Hexadecimal, and enter the Hex. value at DATA text box. 00000011 b7 b6 b5 b4 b3 b2 b1 b0 03

CHAPTER 5 NDA-24301 Pag e 2 56 Revision 1.0 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00-FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 15b 0 Access Code for C.F.-Busy Line and C.F. – Don’t Answer Services 0/1 = Same/Separate Note 1:If a PCS system, C.F.-PS Incoming Call Incomplete also refers to this system data. Note 2:If “0” is assigned, assign either SID: 10 or 12 in command “ASPA”. b 1Maximum number of Multiple Call Forwarding – All Calls/Busy Line occurrences: Note:This data is valid when SYS-1, INDEX 69, bit 7 is assigned as “1”. b 2 b3 b4Miscellaneous Timer Counter (MTC) (0-7)Call Back – Delay Timer Timer Value Setting is MTC × 2 sec. When this data is “000”, Timer value is 2 sec. b 5 b6 b7Call Back – Delay Timer 0/1 = Ineffective/Effective b3b2b1b3b2b1 000: 100: 001: 101: 010: 110: 011:111: once three times twice five times four times

NDA-24301 CHAPTER 5 Page 257 Revision 1.0 4. SYSTEM DATA PROGRAMMING SHEET (1) S Y S 1 SYSTEM DATA INDEX 0-511DATA 00-FFB I TSYSTEM DATA CONTENTS 30 060 Mounting Capacity of Data Memory (DM) : 1~63 Mbyte (01~3F) Normally assigned as “6” 1 2 3 4 5 6 7 4200Access code using Pre-set dialing (e.g.: Special Access Code + Station number) 0/1 : Out/In service 1By cancelling C.F.-PS INCOMING INCOMPLETE 0 = C.F.-DROPPED CALL is also cancelled 1 = C.F.-DROPPED CALL is not cancelled 2Not used 3 4 5 6 7 b7 b6 b5 b4 b3 b2 b1 b0 00 Data b7 b6 b5 b4 b3 b2 b1 b0 0000000 Data

CHAPTER 5 NDA-24301 Pag e 2 58 Revision 1.0 S Y S 1 SYSTEM DATA INDEX 0-511DATA 00-FFB I TSYSTEM DATA CONTENTS 4210 Miscellaneous Time Counter (MTC) is to be assigned a value from 1 Hex to F Hex.1) Announcement PS-Out of Zone disconnection timer (Release Guard timer) Timer value setting is as follows: (TC) sec. × (MTC) When the data is assigned as 00, the default data is 30 sec. 1 2 3 4 Timer class (TC) 0 : – 3 : 2 sec. 6 : – 1 : – 4 : – 7 : – 2 : – 5 : – 5 6 7 Not used 4220Miscellaneous Time Counter (MTC) is to be assigned a value from 1 Hex to F Hex.2) No-tone connection timer to the called party during the handover Timer value setting is as follows: 800 msec.+ (TC) × (MTC) When the data is assigned as 00, the default data is 800 msec. 1 2 3 4Timer class (TC) 0 : – 3 : – 6 : – 1 : 64 msec. 4 : – 7 : – 2 : – 5 : – 5 6 7Not used 4230 Miscellaneous Time Counter (MTC) is to be assigned a value from 1 Hex to F Hex.3) ZT start-up Guard Timer when initialization is in progress. (This is the timer by which the ZT is placed out of Zone and made send PS location registration.) Timer value setting is as follows: (TC) sec.× (MTC) When the data is assigned as 00, the default data is 60 sec. 1 2 3 4 Timer class (TC) 0 : – 3 : 2 sec. 6 : – 1 : – 4 : 30 sec. 7 : – 2 : – 5 : – 5 6 7Not used b7 b6 b5 b4 b3 b2 b1 b0 0 b7 b6 b5 b4 b3 b2 b1 b0 0 b7 b6 b5 b4 b3 b2 b1 b0 0

NDA-24301 CHAPTER 5 Page 259 Revision 1.0 AAED : Assignment of Announcement Equipment Data 1. GENERAL This command is used to assign the trunk information related to Announcement Equipment on a tenant basis. List Up Command: LAED 2. PRECAUTIONS This part describes only the contents of the command added in PCS system. For more details, refer to the “Office Data Specification”.

CHAPTER 5 NDA-24301 Pag e 2 60 Revision 1.0 3. DATA ENTRY INSTRUCTIONS 0 = Common 1 = Japanese 2 = English 3 = German 4 = French 5 = Spanish 6 = Chinese 7 = Russian 8-15 = Spare Note: LANG is available for the Hotel application. LANG Enter EQP as the service feature provided by DAT. 0 ~ 59 : 60 : ANNOUNCEMENT-PS-OUT OF ZONE 61 : AUTOMATIC ANNOUNCEMENT-PS-OUT OF ZONE CALL 62 ~ 127 :EQP 0 = Single connection 1 = Multiple connection M TK parameter appears if M=1 is entered. TK 0 = 30 seconds, and then disconnects 1 = The connection is held until the calling party released C TENANT NUMBER ( TN )ANNOUNCEMENT EQUIPMENT NUMBER ( EQP ) 0 - 127 KIND OF LANGUAGE ( LANG ) 0 - 15DURATION OF CONNECTION ( C ) 0 / 1SENDING RBT ( R ) 0 / 1ANSWER SIGNAL SENDING ( A ) 0 / 1MULTIPLE CONNECTION ( M ) 0 / 1ROUTE NUMBER ( RT )TRUNK NUMBER ( TK ) Enter DAT route number assigned by the ATRK command. RT 0 = Send RBT 1 = Do not send RBT R 0 = Answer Signal is not sent 1 = Answer Signal is sent A Note: Regarding this data, refer to the Office Data Specification. Note Note

NDA-24301 CHAPTER 5 Page 261 Revision 1.0 4. DATA SHEET Note:Parameter LANG is available for the Hotel System. TENANT NUMBER (TN)ANNOUNCE -MENT EQUIPMENT NUMBER (EQP) 0-127KIND OFLANGUAGE (LANG) 0-15 Note DURATION OF CONNEC- TION (C) 0/1SENDING RBT (R) 0/1ANSWER SIGNAL SENDING (A) 0/1MULTIPLE CONNEC- TION (M)0/1ROUTE NUMBER (RT)TRUNK NUMBER (TK)REMARKS

CHAPTER 5 NDA-24301 Pag e 2 62 Revision 1.0 ALGSL : Assignment of Telephone Number Data for LDM 1. GENERAL This command is used to assign the data pertaining to the relationship between the Telephone Number (TELN) and physical station. List Up Command : LLGSL 2. PRECAUTIONS 1. This Telephone Number can be used in the self (local) node only. Use the ALGSN command if the Telephone Number for the Fusion network is required. 2. TYPE parameter designates the programming method of physical station (the result is the same whichever selected). When TYPE = 1 (LENS) is selected, the physical station which accommodates the Telephone Number (TELN) is specified by the LENS. Likewise, TYPE = 2 (STN) is selected, the physical station number (STN) is used. 3. The system data assignment (ASYDL, SYS1, INDEX513 Data 01hex) is needed to provide the Local Data Memory (LDM). 4. The applicable tenant number (TN) range is designated by the ASYD command, SYS1, INDEX8. 5. When deleting the telephone number, the user must first delete the data which is concerned with Group Calling Conference.

NDA-24301 CHAPTER 5 Page 263 Revision 1.0 3. DATA ENTRY INSTRUCTIONS TYPE = 1 (LENS is used to specify the Telephone number.) TYPE = 2 (STN is used to specify the Telephone number.) TELEPHONE NUMBER (TELN) MAX. 16 DIGITSLINE EQUIPMENT NUMBER USER GROUP NUMBER (UGN) UGN TYPE 1 = User Group Number 1 (Fixed) LENS LENS of the physical stationTYPE 1 = LENS is used to specify the Telephone number 2 = STN is used to specify the Telephone number 1 1 1 1 (LENS) 11 TELN Telephone number assigned by the ALGNL command TELEPHONE NUMBER (TELN) MAX. 16 DIGITSSTATION NUMBER (STN) TENANT NUMBER (TN) USER GROUP NUMBER (UGN) UGN TYPE 1 = User Group Number 1 (Fixed) STN Station number of the physical stationTYPE 1 = LENS is used to specify the Telephone number 2 = STN is used to specify the Telephone number 1 1 2 2 TN Tenant number of the physical station TELN Telephone number assigned by the ALGNL command