Home > NEC > Communications System > NEC Neax 2400 Ipx Wireless System Manual

NEC Neax 2400 Ipx Wireless System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Ipx Wireless System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							TABLE OF CONTENTS NDA-24301
    Pag e iv
    Revision 1.0
    This page is for your notes. 
    						
    							NDA-24301 LIST OF FIGURES
    Page v
    Revision 1.0
    LIST OF FIGURES
    Figure TitlePage
    Figure 1-1 Route Connecting Diagram : Built-in PCS System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
    Figure 1-2 Comparison : Standalone Type and Fusion Type   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
    Figure 1-3 Power Supply from the Built-in PCS System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
    Figure 1-4 Local Power Supply   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
    Figure 1-5 Route Connection Diagram : U Interface (When NT1 is used) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
    Figure 2-1 Related Equipment for Built-in Wireless System (When using PA-4CSIC)   . . . . . . . . . . . . . . . . . . . 26
    Figure 2-2 Related Equipment for Built-in Wireless System (When using PA-4CSIE)   . . . . . . . . . . . . . . . . . . . 28
    Figure 2-3 Standard Installation Image   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
    Figure 2-4 High Traffic Installation Image   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
    Figure 2-5 Image of ZT Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
    Figure 2-6 Examples of Inappropriate Mounting   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
    Figure 2-7 Dimension Drawing for ZT Installation (1/2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
    Figure 2-8 Dimension Drawing for ZT Installation (2/2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
    Figure 2-9 Mounting of the ZT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
    Figure 2-10 Local Power Feeding   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
    Figure 2-11 LEDs on the Zone Transceiver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
    Figure 2-12 Adjustment of Antenna  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
    Figure 3-1 Location of Card in System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
    Figure 3-2 Lamp, Key and Connectors : PA-4CSIC   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
    Figure 3-3 LT Connector Leads Accommodation of PIM : PA-4CSIC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
    Figure 3-4 Connecting Route Diagram   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
    Figure 3-5 Location of Card in System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
    Figure 3-6 Lamp, Key and Connectors : PA-4CSID   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
    Figure 3-7 LT Connector Leads Accommodation of PIM : PA-4CSID  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
    Figure 3-8 Connecting Route Diagram   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
    Figure 3-9 Location of Card in System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
    Figure 3-10 Lamp, Key and Connectors : PA-4CSIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
    Figure 3-11 LT Connector Leads Accommodation of PIM : PA-4CSIE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
    Figure 3-12 Connecting Route Diagram   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
    Figure 3-13 Location of Card in System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
    Figure 3-14 Lamp, Key and Connectors : PA-4CSIF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
    Figure 3-15 LT Connector Leads Accommodation of PIM : PA-4CSIF   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
    Figure 3-16 Connecting Route Diagram   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
    Figure 3-17 Location of Card in the System   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
    Figure 3-18 Lamp, Key and Connectors: PA-CK16  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
    Figure 3-19 LT Connector Lead Accommodation of PIM: PA-CK16 (1/2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
    Figure 3-19 LT Connector Lead Accommodation of PIM: PA-CK16 (2/2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   91
    Figure 3-20 Connecting Route Diagram   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
    Figure 3-21 Example of Clock Network Using PA-CK16 [SYNC]   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93
    Figure 4-1 PS Roaming in Release 8 Enhancement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
    Figure 4-2 ATRK for 24PRT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
    Figure 4-3 ATRK for 24DTI + 2DCH   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
    Figure 4-4 ATRK for 30PRT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 
    						
    							LIST OF FIGURES NDA-24301
    Pag e v i
    Revision 1.0
    LIST OF FIGURES
    Figure TitlePage
    Figure 4-5 ATRK for 30DTI + 2DCH   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
    Figure 4-6 Group Call-Automatic Conference using Station Hunting-Circular  . . . . . . . . . . . . . . . . . . . . . . . . . 177
    Figure 4-7 Outline of Short Text Message (STM) Service  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
    Figure 5-1 Command Descriptions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
    Figure 6-1 Make-Busy Set of CSINT Circuit Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
    Figure 6-2 Make-Busy Cancel of CSINT Circuit Card   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
    Figure 6-3 Make-Busy Set of ZT and Each B Channel   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
    Figure 6-4 Make-Busy Cancel of ZT and Each B Channel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 
    						
    							LIST OF TABLES
    Ta b l e T i t l ePage
    NDA-24301 LIST OF TABLES
    Pag e vii
    Revision 1.0 Table 1-1 System Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  .  6
    Table 1-2 List of Wireless Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
    Table 1-3 List of OG Call Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
    Table 1-4 List of IC Call Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
    Table 1-5 List of Station Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
    Table 1-6 List of Other Service Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18
    Table 1-7 List of Attendant Console Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19
    Table 1-8 List of Network Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21
    Table 1-9 List of Operation/Maintenance Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21
    Table 1-10 List of ISDN Service Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22
    Table 1-11 List of CCIS Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
    Table 2-1 Meaning of LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  41
    Table 3-1 Switch Setting Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  54
    Table 3-2 PA-CK16 Lamp Indications Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  88
    Table 3-3 Standard Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  89
    Table 4-1 Roaming Class Data List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  133
    Table 4-2 List of OG Call Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  137
    Table 4-3 List of IC Call Features for Q.931a. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  137
    Table 4-4 List of Station Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  139
    Table 4-5 List of Other Service Features for Q.931a  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  143
    Table 4-6 List of Attendant Console Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
    Table 4-7 List of Network Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  146
    Table 4-8 List of Operation/Maintenance Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  146
    Table 4-9 List of ISDN Service Features for Q.931a  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  147
    Table 4-10 List of CCIS Service Features for Q.931a  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  148
    Table 4-11 Route Class Data Assignment Table for Q.931a  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  152
    Table 5-1 List of Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  193
    Table 5-2 SFI  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . . . . . . .  248 
    						
    							LIST OF TABLES NDA-24301
    Pag e v iii
    Revision 1.0
    This page is for your notes. 
    						
    							NDA-24301 PREFACE
    Page ix
    Revision 1.0
    PREFACE
    This manual explains the necessary hardware (such as circuit cards, terminal), the data programming, service
    features, etc. for the Built-in PCS (Personal Communication System) System. Since this manual describes the only
    specific information for the Built-in PCS System, see the existing manuals for the installation, functions, service
    features and the system operation/maintenance job of the PBX itself. 
    						
    							PREFACE NDA-24301
    Pag e x
    Revision 1.0
    This page is for your notes. 
    						
    							NDA-24301 CHAPTER 1
    Page 1
    Revision 1.0
    CHAPTER 1 GENERAL DESCRIPTION
    1. GENERAL DESCRIPTION OF SYSTEM
    The Built-in PCS System has its CSINT, which interfaces the ZT with the system, mounted in the Port Interface
    Module (PIM). The Control Processor Rack (CPR) exclusively designed for the PCS is necessary in the PBX.
    Figure 1-1 shows the entire route connecting diagram of this system.
    Module structures of the Built-in PCS System are identical to that of the PBX. For more details, see the
    “Installation Design Manual”.
    Figure 1-1  Route Connecting Diagram : Built-in PCS System
    Note 1:
    A maximum of four (4) ZTs can be connected to one CSINT circuit card.
    Note 2:If the receive tone level of the PS is low, please select -5 dB (GAIN) in the PAD data of the COT Route by
    the command ARTD.
    ZT
    ZT
    ZT
    ZT
    PRT
    ODT PBX
    PS
    PS
    Analog
    TEL
    MATISDN
    CCTCCIS
    PSTN CSINT
    ELC ELC
    LC
    CFT
    IOCACIS
    COT/DTI
    D
    term
    (Note 1)
    (Note 2) 
    						
    							CHAPTER 1 NDA-24301
    Page 2
    Revision 1.0
    GENERAL DESCRIPTION
    Figure 1-2  Comparison : Standalone Type and Fusion Type
    Wired Terminal
    Standalone Type
    Wired Terminal
    Built-in PCS System
    Wireless Terminal
    Wireless Terminal
    Wired TerminalWireless Terminal
    NEAX2400
       IPX
    FCCS
    (Fusion Link)
    Fusion Type
    NEAX2400
       IPX
    PS
    ZT PSZT
    ZT
    ZT PS
    PS 
    						
    							NDA-24301 CHAPTER 1
    Page 3
    Revision 1.0
    GENERAL DESCRIPTION
    2. CONNECTION BETWEEN CSINT AND ZT
    Figures 1-3 through 1-5 illustrate connection methods between the CSINT and the ZT. The CSINT and the ZTs
    can be connected with two pairs of twisted cable using the following two connection methods - one, line voltage
    from the Built-in PCS System and the other, the local power supply.
    1. PBX line power from Built-in PCS System.
    Line Power from the PCS System is power to the ZT supplied from the PBX.
    Figure 1-3  Power Supply from the Built-in PCS System
    2. Local Power Supply
    Local power for the ZT is supplied via AC-DC adapter from the AC.
    Figure 1-4  Local Power Supply
    3. U Interface (NT1 is used)
    Figure 1-5  Route Connection Diagram : U Interface (When NT1 is used)
    S interface PBX
    CSINT
    (PA-4CSICZT
    /PA-4CSIE)
    S interface PBXCSINT(PA-4CSICZT
    /PA-4CSIE)
    ZT NT1 U InterfaceCSINT(PA-4CSID
    PBX
    S Interface
    /PA-4CSIF) 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Ipx Wireless System Manual