Figure3-17AligningthePedestalFrontBezel 3.Rotatethebezelagainstthechassissothatitsnapsintoplace. InstallingInternalHardDiskDrives Thissectionprovidesinformationaboutinstallingadditionalinternalharddiskdrives. CAUTION:Ahot-pluggabledevicecanrequireinteractionwiththeoperatingserverbeforethe devicecanbesafelyinstalledintotheserver.Verifythattheoperatingsystemsupportsinstalling diskdriveswhiletheoperatingsystemisrunning.Iftheoperatingsystemdoesnotsupportthis feature,shutdowntheoperatingsystembeforeattemptingthisprocedure.Failuretoobserve thiscautionwillresultinsystemfailure. Figure3-18FrontViewoftheHP9000rp3410/rp3440Server Twoadditionalharddiskdrivescanbeaddedtotheserverinslots2and3.Alwaysuselow profilediskdrives(1inchheight)inHP9000rp3410andrp3440servers. Toinstallaharddiskdrive,followthesesteps: InstallingAdditionalComponents61

1.Ifyouwillbelockingtheharddriveinplace,youmustremovethecovertoaccessthehard drivelock. a.Ifrack-mounted,slidetheserveroutfromtherackuntilitstops.(See“ExtendtheServer FromtheRack”(page53).) b.Removethecoverandbezel.(See“RemovingandReplacingServerCoversandBezels” (page52).) 2.Removetheslotfillerthatisinstalledintheslotwheretheadditionaldriveistobeinstalled. Figure3-19FillerRemovalfromSlot1 3.Slidetheharddiskdriveintotheslotuntilitisseated. Figure3-20DiskDriveInstallationinSlot3 62InstallingtheSystem

4.Closethedriveejectorhandlebypushingitdownuntilitclicks. 5.Ifdesired,locktheharddriveinplace. a.Presstheharddrivelockingleverdownintothelockedposition. b.Replacethecoverandbezel.(See“RemovingandReplacingServerCoversandBezels” (page52).) Figure3-21HardDriveLock 6.Verifythedriveinstallationbyusingthesystemutilities. •UsetheiLOMPcommandstoverifyoperation. •UsetheBCHcommandstoverifyoperation. •Usediagnosticsprovidedbytheofflinediagnosticenvironmenttoexercisethemodule added. 7.Ifrack-mounted,slidetheserverbackintotherackuntilitstops. 8.Checktheinstallationoftheharddiskdrivebypoweringontheserverandcheckingthe virtualfrontpanelandSystemEventLog(SEL)forcorrectstatusfortheharddiskdrive. InstallingAdditionalComponents63

InstallingaDVDDrive InstallaDVDdrivebehindthefrontbezel. WARNING!Ensurethattheserverispoweredoffandallthepowersourceshavebeen disconnectedfromtheserverbeforeremovingorreplacingaremovablemediadrive. VoltagesarepresentatvariouslocationswithintheserverwheneveranACpowersourceis connected.Thisvoltageispresentevenwhenthemainpowerswitchisintheoffposition. Failuretoobservethiswarningcanresultinpersonalinjuryordamagetoequipment. CAUTION:ObserveallESDsafetyprecautionsbeforeattemptingthisprocedure.Failureto followESDsafetyprecautionscanresultindamagetotheserver.Failuretoproperlycomplete thestepsinthisprocedurewillresultinerraticserverbehaviororsystemfailure.Forassistance withthisprocedure,contactyourlocalHPAuthorizedServiceProvider. Figure3-22DVDDriveInstallation InstallingtheDVDDrive ToinstallaDVDdrive,followthesesteps: 1.Powerofftheserveranddisconnectthepowerandexternalcables. 2.Removethefrontbezelandcover.(See“RemovingandReplacingServerCoversandBezels” (page52).) 3.Ifaremovablemediadrivehasnotpreviouslybeeninstalledintheserver,thedriveslotis coveredwithaDVDdrivefiller.RemovetheDVDdrivefiller. 4.Slidethedriveintothedrivebayuntilitstopsslidingandtheretainingclipsonbothsides ofthedrivesnapintoplace(Figure3-22). 5.ConnecttheIDEcableonthebackofthedrive(Figure3-22). 6.Replacethecoverandbezel.(See“RemovingandReplacingServerCoversandBezels” (page52).) 7.Reconnectthepowerandexternalcables. 8.Turnontheserver. 64InstallingtheSystem

9.Verifythedriveoperationbyusingthesystemutilities. •UsetheiLOMPcommandstoverifyoperation. •UsetheBCHcommandstoverifyoperation. •Usediagnosticsprovidedbytheofflinediagnosticenvironmenttoexercisethenewly installedmodule. RemovingandReplacingAirflowGuides Youmustremoveairflowguidesbeforeinstallingprocessorsormemory.Theserverhasthe followingairflowguides: •Theprocessorairflowguideensuresthatthepropervolumeofairforcoolingthedual processormodulepowerpods,processormodules,andvoltageregulatormodulesflows overthesecomponents.Youmustremovetheprocessorairflowguidebeforeremovingor installingadualprocessormodule. •Thememoryairflowguideensuresthatthepropervolumeofairflowsoverthememory DIMMstocoolthem.ToaccessmemoryDIMMsandsockets,youmustremovethememory airflowguide. NOTE:Airflowsthroughtheserverfromfronttoback. Figure3-23AirflowGuidesLocations RemovingandReplacingtheMemoryAirflowGuide RemovingtheMemoryAirflowGuide Toremovethememoryairflowguide,followthesesteps: 1.Powerofftheserveranddisconnectthepowerandexternalcables. 2.Removetheserverchassiscover.(See“RemovingandReplacingtheTopCoverona Rack-MountedServer”(page53).) InstallingAdditionalComponents65

3.Graspthememoryairflowguideandliftitoutoftheserver. Figure3-24RemovingtheMemoryAirflowGuide ReplacingtheMemoryAirflowGuide Toreplacethememoryairflowguide,followthesesteps: 1.Aligntheguidesonbothsidesoftheairflowguidewiththeslotsonthechassis. 2.Insertthememoryairflowguideintheslots. 3.Replacethecover.(See“RemovingandReplacingtheTopCoveronaRack-MountedServer” (page53).) RemovingandReplacingtheProcessorAirflowGuide RemovingtheProcessorAirflowGuide Toremovetheprocessorairflowguide,followthesesteps: 1.Powerofftheserver,anddisconnectthepowerandexternalcables. 2.Removetheservercover.(See“RemovingandReplacingtheTopCoveronaRack-Mounted Server”(page53).) 3.RemovetheIDEcableandpowermodulecablesfromtheprocessorairflowguidecable clips. 66InstallingtheSystem

4.Removethemainportionoftheairflowguide: a.Holdtheguideusingtheopeningontopoftheguide. b.Atthesametime,graspthebackendoftheprocessorairflowguideandlifttheguide outoftheserver. Figure3-25RemovingtheProcessorAirflowGuide 5.Graspsystemfan1Aandliftitfromitssocket. Figure3-26RemovingFans1Aand1B 6.Graspsystemfan1Bandliftitfromitssocket(Figure3-26). 7.Removethememoryairflowguide.“RemovingtheMemoryAirflowGuide”(page65) InstallingAdditionalComponents67

8.Rotatetheclipclockwisetoreleasethelatch. Figure3-27OpeningtheReleaseClip 9.Todisconnectthepowercableconnectedtotheguidefromthesystemboard,squeezethe clips. 10.Liftthefrontportionoftheprocessorairflowguideoutoftheserver. Figure3-28RemovingtheFrontPortionoftheProcessorAirflowGuide 68InstallingtheSystem

ReplacingtheProcessorAirflowGuide Toreplacetheprocessorairflowguide,followthesesteps: 1.Replacethefrontportionoftheairflowguide: a.Alignthereleaselatchofthefronthalfoftheairflowguideoverthereleaselatchpost andsnapitinplace. b.Connectthepowerconnectoronthefrontportionoftheguidetotheconnectoronthe systemboard. 2.Insertsystemfans1Aand1Bintotheirmountingpositions. 3.Routetheprocessorturbofanpowercablesthroughtheprocessorheatsinkpostssothatthe cableswillnotbepinchedbetweentheheatsinkpostsandtheprocessorairflowguide (Figure3-29). CAUTION:Turbofanpowercablescanbedamagedifpinchedbetweentheheatsinkposts andtheprocessorairflowguide.Ensurethatthecablesarebelowthetopsurfaceofthe heatsinkpostsbeforeinstallingtheprocessorairflowguide. Figure3-29RoutingtheTurbofanPowerCablesThroughHeatsinkPosts 4.Replacethemainportionoftheairflowguide: a.Holdtheopeningontopoftheprocessorairflowguide. b.Atthesametime,graspthebackendoftheairflowguideandinserttheairflowguide intotheserver. c.Connectthepowermodulecable. d.PlacethepowerandIDEcablesinthecableclips. e.Insertthetwoairflowguideretainingtabsintothetwoslotsonthefronthalfofthe airflowguide. f.Replacethememoryairflowguide.“ReplacingtheMemoryAirflowGuide”(page66) 5.Replacetheservercover. InstallingAdditionalComponents69

InstallingAdditionalSystemMemory Theserverhas12memorysocketsforinstallingDDRSDRAMmemorymodules.Systemmemory DIMMsarelocatedonthesystemboard. WARNING!Ensurethattheserverispoweredoffandallthepowersourceshavebeen disconnectedfromtheserverbeforeremovingorreplacingthesystemmemory. VoltagesarepresentatvariouslocationswithintheserverwheneveranACpowersourceis connected.Thisvoltageispresentevenwhenthemainpowerswitchisintheoffposition. Failuretoobservethiswarningcanresultinpersonalinjuryordamagetoequipment. CAUTION:ObserveallESDsafetyprecautionsbeforeattemptingthisprocedure.Failureto followESDsafetyprecautionscanresultindamagetotheserver. SupportedDIMMSizes SupportedDIMMsizesareasfollows: •256MB •512MB •1GB •2GB) •4GB(HP9000rp3440only).If4GBDIMMsareused,onlyoneconfiguration(8X4GBin thefirsteightsockets)issupported. DissimilarDIMMsizescanbeusedacrosstheentiresystemboard(exceptwhen4GBDIMMs areused)butbothDIMMsinapair(firstgroupoffour,connectors0Aand0BofHP9000rp3410) andallfourDIMMsofanyquadmustbeidentical. 70InstallingtheSystem