1.Graspthenewsystemboardbyitsedgesandcarefullyalignitintheserver: a.AngletheboardtoenablethePCIconnectortoslideintothePCIcardcagebayarea. b.Alignthesystemboardkeyholeswiththeirstandoffsonthechassis. c.SlidethePCIconnectorpostsonthesystemboardintotheirslotsontheserverchassis. Figure6-68AligningtheSystemBoardPCIConnector 2.Slidethesystemboardbacktowardtherearoftheservertosecurethesystemboardonits standoffs. Figure6-69SlidingtheSystemBoardintheChassis RemovingandReplacingtheSystemBoard181
3.Screwinthesystemboardmountingscrew. 4.Connectallthecablestotheirappropriateconnectorsonthesystemboard. 5.Screwinthesixrearbackplanesystemboardmountingscrews. Figure6-70InstallingtheRearPanelMountingScrews 6.ReplacethemechanicalcoversovertheVGAandDB9ports. Figure6-71ReplacingMechanicalCovers 7.Replacethepowerconnectorsintheirslotsonthebackoftheserverandscrewinthepower connectormountingscrews. Figure6-72ReinstallingthePowerConnectors 8.Replacethefollowingservercomponents: •iLOMPcard.(See“ReplacingtheiLOMPCard”(page174)) •Dualprocessormodules.(See“InstallingaDualProcessorModule”(page160)) •MemoryDIMMs.(See“InstallingSystemMemory”(page152)) 182RemovingandReplacingComponents
•Processorairflowguide.(See“ReplacingtheProcessorAirflowGuide”(page148)) •Memoryairflowguide.(See“ReplacingtheMemoryAirflowGuide”(page145)) •PCIcardcage.(See“RemovingthePCICardCage”(page167)) •Systemfans.(See“ReplacingaSystemFan”(page138)) 9.Replacethetopcover. 10.Reconnectallthepowerandexternalcablesandturnontheserver. 11.Ifyouhaveinstalledanewsystemboard,youmustwritetheserialnumberandmodel stringdatatothenewsystemboard.Towritetheserverinformationtothenewsystem board,followthesesteps: a.Locatethesystemserialnumberandnoteitforuseinthefollowingsteps.Thesystem serialnumberisfoundintwoplaces: •Ontheleftofthefrontbezel,buttotherightofthediskdrives,locatethepulltab andextendthetabfromtheservertodisplayproductinformation.Alabel containingthesystemserialnumberisattachedtothepulltab.(Figure6-73 (page185)) •Alabelcontainingthesystemserialnumberislocatedontherightsideofthe chassis,asyoufacetheserver. b.Monitorserverstartuponaterminal.AttheBCHprompt,entertheSERcommandto calluptheservicemenu.(ForadditionalinformationabouttheBCH,seeAppendixB (page199).) c.Attheservicemenuprompt,entertheINITcommandtoenteroriginalproductnumber andsystemserialnumber. d.Whenpromptedtochange,entertheproductnumberthatisonthepulltabandconfirm byenteringYwhenprompted. e.Whenprompted,enterthesystemserialnumber. f.Whenprompted,enterYtoconfirmthechange. NOTE:Ifyourproductisabasesystemthatisoneprocessor800mhzCPU,skipsteps g-jandgotostepktoresettheserver. g.Entertheupgradecommandattheservicemenuprompt.Youwillbeaskedforthe systemserialnumber. h.Enterthesamesystemserialnumberasyoupreviouslyenteredfromthepull-outtag. i.Enterthekeyfromthekeycertificatethatisonthebackofthepull-outtag.Thekey certificatenumbermustbethenumberthatappliestothissystemserialnumberorall thesystemcomponentswillnotbeenabled.Acurrentsystemvaluedisplays(rp3410 DC--)withtheupgradedsystemvalue(theoriginalvalue).Thefollowingprompt displays: Do you wish to continue with the change? j.EnterYtocontinuewiththechange. k.EntertheRESETcommandtoresettheserverwiththechangesineffect. NOTE:Ifyouperformedanupgrade,thecertificateshowsanewkeyandmodelnumber tobeused 12.Verifythesystemboardreplacementandoperationbyusingthesystemutilities.(For additionalinformation,seeAppendixB(page199)ortheHPIntegrityandHP9000iLOMP OperationsGuide.) •UsetheiLOMPcommandstoverifyoperation. •UsetheBCHcommandstoverifyoperation. RemovingandReplacingtheSystemBoard183
ReplacingtheResidentSystemBoardwithaReplacementSystemBoard AllA7136B,A9948A,andA9949Aproductswithinthedocumentedserialnumberrangeswere shippedfromthefactorywithanincorrectsystemsettingproductnumber. CAUTION:A7137-69001,HP9000rp34x0,changingtoyoursystemsettings. Ifthisprocedureisnotperformedcorrectly,youwillnotbeabletosetyourserverupwithout thehelpofanHPCustomerEngineer. AffectedSerialNumbers: •USL0804515-USE4444KD3 •SG40909239-SG44719451 •JPA0409004-JPA0444016 •DE40900020-DE44700079 Forthelifeoftheaffectedsystems,thefactory-programmedvaluemustbemaintainedwhen enteringthesystemproductnumberinsteadofthevalueonthesystempull-outtag.Failureto dosocancauselicensedcustomerapplicationstofail. AffectedProductNumbers: Forthefollowingproductnumbers,A7137Amustbeusedwhenenteringthesystemsetting productnumber,asdetailedinstep5ofthefollowingprocedure: A9948A-rp3440-1Way800MHzSolution A9949A-rp3440-1Way1GHzSolution A7136AmustbeusedwhenenteringthesystemsettingproductnumberfortheA7136B-rp3410-1 WayBaseserver800MHzSolution,asdetailedinstep5ofthefollowingprocedure. WARNING!Ensurethattheserverispoweredoffandallthepowersourceshavebeen disconnectedfromtheserverbeforeremovingorreplacingaremovablesystemdrive. VoltagesarepresentatvariouslocationswithintheserverwheneveranACpowersourceis connected.Thisvoltageispresentevenwhenthemainpowerswitchisintheoffposition. Failuretoobservethiswarningcanresultinpersonalinjuryordamagetoequipment. CAUTION:ObserveallESDsafetyprecautionsbeforeattemptingthisprocedure.Failureto followESDsafetyprecautionscanresultindamagetotheserver.Failuretoproperlycomplete thestepsinthisprocedurewillresultinerraticserverbehaviororserverfailure.Forassistance withthisprocedurecontactyourlocalHPAuthorizedServiceProvider. Beforereplacingtheresidentsystemboardwiththereplacementsystemboard(A7136-69001), youmustlocatethepull-outtagthatisonthechassisofyourserver.Thisprovidesyouwiththe systemproductnumber,systemserialnumber,andkeycertificatenumberthatyouneedtoset upthesystemboard. 184RemovingandReplacingComponents
Figure6-73SystemProductNumber,SystemSerialNumber,KeyCertificate ReplacingaSystemBoard Youmustperformthefollowingproceduretoensureallcomponentsintheserverarefunctional. Toreplacethesystemboard,followthesesteps: 1.Removethesystemboard.(See“RemovingtheSystemBoard”(page177).) 2.Replacethesystemboardwiththereplacementsystemboard.(See“ReplacingtheSystem Board”(page180).) 3.Powerthesystemon. 4.AttheBCHprompt,entertheSERcommand.Thisputsyouintotheservicemenu. 5.Attheservicemenuprompt,entertheINITcommand. NOTE:TheINITcommandonlyworksontherepairboard. 6.Whenprompted,entertheproductnumberlocatedonthepull-outtag.Confirmbyanswering Ywhenasked.Ifyoumadeamistakeenteringtheproductnumber,youcananswerNand re-entertheproductnumberwhenasked. 7.Enterthesystemserialnumberwhenprompted.Ifyouaccidentallyhitreturnwithout enteringthesystemserialnumber,youwillhaveadefaultvalue.Confirmtheoriginalserial numberbyenteringYwhenasked.Ifyoumadeamistakeenteringtheserialnumber,you canenterNandre-entertheserialnumberwhenasked. 8.Ifyourproductisaoneprocessor800MHzCPU,skipsteps9-12andgotostep13toreset yourserver. 9.Attheservicemenuprompt,enterupgrade.Thesystemasksyouforthesystemserial number. 10.Enterthesystemserialnumberfromthepull-outtag. 11.Enterthekeyfromthekeycertificatethatisonthebacksideofthepull-outtag.Thekey certificatenumberandsystemserialnumberareapairandmustbeusedtogether.Ifyou donotenterthecorrectkeycertificatenumber,theservercomponentswillnotfunction. 12.Thescreendisplaysthecurrentsystemvalue(rp3410DC--)andtheoriginalupgradedsystem value.Youwillbepromptedwiththequestion“Doyouwishtocontinuewiththischange?” AnswerYtoconfirmthechange. 13.Enterresettoreboottheserver.performtheresettingwiththechangesineffect. ReplacingtheResidentSystemBoardwithaReplacementSystemBoard185
14.Performtheresettingwiththechangesineffect. CAUTION:Ifthisprocedureisnotfollowed,theservercomponentswillnotbefunctional. RemovingandReplacingthePowerSupplyInterfaceModule ThePowerSupplyInterface(PSI)modulesupportsuptotworedundantpowersupplies. RemovingthePowerSupplyInterfaceModule Toremovethepowersupplyinterfacemodule,followthesesteps: 1.Powerofftheserveranddisconnectallthepowerandexternalcables. 2.Removethetopcover.(See“RemovingandReplacingServerCoversandBezel”(page126).) 3.Removethesystemboard.(See“RemovingtheSystemBoard”(page177).) 4.Liftthepowercablesoutoftheirmetalholdingclips. Figure6-74PowerCablesandHoldingClips 186RemovingandReplacingComponents
5.UnscrewthePSImountingscrewandremovethePSImodulefromtheserver. Figure6-75RemovingtheMountingScrew Figure6-76RemovingthePSIInterfaceModule ReplacingthePowerSupplyInterfaceModule Toreplacethepowersupplyinterfacemodule,followthesesteps: RemovingandReplacingthePowerSupplyInterfaceModule187
1.PlacethePSImoduleintothechassisbyslidingthemoduleretainingtabintothesocketon theharddiskdrivebaywall. Figure6-77ReplacingthePowerSupplyInterfaceModule 2.ScrewinthePSImodulemountingscrewandsecurethepowercablesbehindtheholding clips. Figure6-78SecuringthePowerSupplyInterfaceModuleandCables 3.Replacethesystemboard.(See“ReplacingtheSystemBoard”(page180).) 4.Replacethetopcover. 5.Reconnectallthepowerandexternalcables. 188RemovingandReplacingComponents
6.VerifythePSIreplacementandoperationbyusingthesystemutilities.(Foradditional information,seeAppendixB(page199)ortheHPIntegrityandHP9000iLOMPOperations Guide.) •UsetheiLOMPcommandstoverifyoperation. •UsetheBCHcommandstoverifyoperation. RemovingandReplacingtheHardDiskDrive(SCSI)Backplane RemovingtheHardDriveDiskSCSIBackplane ToremovetheharddrivediskSCSIbackplane,followthesesteps: 1.Powerofftheserveranddisconnectallthepowerandexternalcables. 2.Removethetopcover.(See“RemovingandReplacingServerCoversandBezel”(page126).) 3.LiftuponthePCIcardcagereleaseleverandthebackedgeofthePCIcardcageandliftthe PCIcardcageoutoftheserver.(See“RemovingandReplacingthePCICardCage”(page167).) 4.Removefans2and3.(See“RemovingandReplacingSystemFans”(page136).) 5.Liftuponthefanpowerbridgeanddisconnectthebackplanepowercable. Figure6-79OpeningtheFanPowerBridge 6.DisconnecttheSCSIcablesandunscrewthebackplanemountingscrews. RemovingandReplacingtheHardDiskDrive(SCSI)Backplane189
Figure6-80DisconnectingtheSCSICables Figure6-81RemovingtheMountingScrews 190RemovingandReplacingComponents