7.Removetheharddrivebackplanebyslidingitinthedirectionofthearrowandpullingit outwardfromitsstandoffposts. Figure6-82RemovingtheSCSIBackplane Figure6-83RemovingtheSCSIBackplaneFromtheChassis ReplacingtheHardDiskDriveSCSIBackplane ToreplacetheharddiskdriveSCSIbackplane,followthesesteps: RemovingandReplacingtheHardDiskDrive(SCSI)Backplane191
1.Inserttheharddrivebackplaneontoitsfourchassisstandoffsandslideittotheleftasyou faceit.Thislockstheharddrivebackplaneinplace. 2.ScrewinthetwobackplanemountingscrewsandconnectthetwoSCSIcables. 3.Connectthebackplanepowercableandlowerthefanpowerbridgeuntilitsnapsinplace. 4.Replacefans2and3.(See“RemovingandReplacingSystemFans”(page136).) 5.ReplacethePCIcardcage.(See“ReplacingthePCICardCage”(page168).) 6.Replacethetopcover. 7.Reconnectallthepowerandexternalcables. 8.Verifythebackplanereplacementandoperationbyusingthesystemutilities.(Foradditional information,seeAppendixB(page199)ortheHPIntegrityandHP9000iLOMPOperations Guide.) •UsetheiLOMPcommandstoverifyoperation. •UsetheBCHcommandstoverifyoperation. 192RemovingandReplacingComponents
AReplacementParts Thisappendixprovidesareplacementpartslistthatcontainsthefollowingcustomerself-repair partinformationfortheserver: •ManufacturingPartNumber •Description •ReplacementPartNumber,ifapplicable •ExchangePartNumber,ifapplicable PartsIllustrations FigureA-1providespartsidentificationillustrations.Seethereplaceablepartslisttoidentify partnumbers. NOTE:ThepartsdisplayedinFigureA-1donotrepresentallthepartsintheHP9000rp3410 andrp3440servers. FigureA-1PartsIdentification FigureA-2showsthepedestalandrackpartsfortheHP9000rp3410andrp3440servers.Seethe replaceablepartslisttoidentifypartnumbers. PartsIllustrations193
FigureA-2PedestalandRackParts CustomerSelfRepair HPproductsaredesignedwithmanyCustomerSelfRepair(CSR)partstominimizerepairtime andallowforgreaterflexibilityinperformingdefectivepartsreplacement.Ifduringthediagnosis periodHP(orHPserviceprovidersorservicepartners)identifiesthattherepaircanbe accomplishedbytheuseofaCSRpart,HPwillshipthatpartdirectlytoyouforreplacement. TherearethreecategoriesofCSRparts: YesPartsforwhichcustomerselfrepairismandatory.IfyourequestHPtoreplace theseparts,youwillbechargedforthetravelandlaborcostsofthisservice. OptionalPartsforwhichcustomerselfrepairisoptional.Thesepartsarealsodesignedfor customerselfrepair.If,however,yourequirethatHPreplacethemforyou,there mayormaynotbeadditionalcharges,dependingonthetypeofwarrantyservice designatedforyourproduct. NoSomeHPpartsarenotdesignedforcustomerselfrepair.Tosatisfythecustomer warranty,HPrequiresthatanauthorizedserviceproviderreplacethepart. 194ReplacementParts
Basedonavailabilityandwheregeographypermits,CSRpartsareshippedfornextbusiness daydelivery.Same-dayorfour-hourdeliverymaybeofferedatanadditionalchargewhere geographypermits.Ifassistanceisrequired,youcancalltheHPTechnicalSupportCenterand atechnicianwillhelpyouoverthetelephone. HPspecifiesinthematerialsshippedwithareplacementCSRpartwhetheradefectivepartmust bereturnedtoHP.IncaseswhereitisrequiredtoreturnthedefectiveparttoHP,youmustship thedefectivepartbacktoHPwithinadefinedperiodoftime,normallyfive(5)businessdays. Thedefectivepartmustbereturnedwiththeassociateddocumentationintheprovidedshipping material.FailuretoreturnthedefectivepartmayresultinHPbillingyouforthereplacement. WithaCSR,HPpaysforalltheshippingandpartreturncostsanddeterminesthecouriertobe used. FormoreinformationaboutHP'sCustomerSelfRepairprogram,contactyourlocalservice provider.FortheNorthAmericanprogram,seetheHPwebsiteathttp://www.hp.com/go/ selfrepair. TableA-1providesCSRinformation. TableA-1CustomerSelfRepairInformation CommentsDescriptionLevelCode Requiresyoutoreplacethesepartsunderwarranty. Notechnicalskillsrequired. LevelAwithinstructions availableintheserviceguide YesAY Lowtomoderatetechnicalskillsrequired.LevelBwithinstructions availableintheserviceguide OptionalBY Hightechnicalskillsrequired.LevelCwithinstructions availableintheserviceguide OptionalCY SomeHPpartsarenotdesignedforcustomerselfrepair.In ordertosatisfythecustomerwarranty,HPrequiresthatan authorizedserviceproviderreplacethepart. Notacustomerreplaceable part. NoN ReplaceablePartsList Theitemsinthislistandthecorrespondingitemnumbersarethecustomerself-repairunitsfor HP9000rp3410andrp3440servers. Theitemnumberslistedbelowareusedwiththepartillustrationsinordertoidentifythe nomenclatureofthepart.Partnumbersarefoundbyusingthepartnomenclaturefromthislist toselectthecorrectpartfromtheHPPartsurfer. NOTE:Ifyouneedtoreplaceasystemboard,firstremovetheprocessormodules,DIMMs, andadapterboards,andthentransferthesetothenewboard.Ensurealljumperandswitch settingsontheoldboardaretransferredtothenewboard. NOTE:ThereplaceablepartslistcontainspartsthatdonotdisplayinFigureA-1orFigureA-2. WhenorderingpartsforHP9000rp3410andrp3440servers,seeTableA-2. TableA-2ReplaceablePartsList CustomerSelf Repair PartNumber Exchange PartNumber Replacement DescriptionItem No. PCABoards(SystemComponents) NN/AA7231-04018PowerSupplyInterfaceModule22 CYA7231-69520A7231-66520SCSIBackplaneN/A CYA7136-69001A7136-67001SystemBoard(A7136-60001);64MBCache (CPUsrequirePDCgreaterthan44.52) 23 ReplaceablePartsList195
TableA-2ReplaceablePartsList(continued) CustomerSelf Repair PartNumber Exchange PartNumber Replacement DescriptionItem No. CYN/AA7231-66530PCIbackplane/PCIRiser17 NN/AA7231-66550DisplayPanel12 CYN/AA7231-66580iLOMPCard13 OpticalDevices NA7231-69012A7231-62012DVDDrive,Slimline(A9919A)14 NA7231-69014A7231-62024CD-RW/DVDComboDrive,Slimline (A9920A) 14 Memory AYN/AA6967-67001256MBDDR-SDRAMDIMM(AB542A))2 AYN/AA6968AX512MBDDR-SDRAMDIMM(A9773A))2 AYA6969-69001A6969AX1GBDDR-SDRAM(rp3440(A9774A))2 AYA6835-69001A6970AX2GBDDR-SDRAM(rp3440)(A9775A)2 AYAB475-69001AB475AX4GBDDR-SDRAM,(rp3440)(AB561A) (thereisan8-slotrestrictionforthisDIMM) 2 InternalDisks/RemovableMedia(HardDiskDrives) BNA9896-69001A9896-6400136GB,15KRPMUltra320SCSIDiskDrive (A9796A) 15 BNA9897-69001A9897-6400173GB,15KRPMUltra320SCSIDiskDrive (A9897A) 15 BNA9898-69001A9898-64001146GB,10KRPMUltra320SCSIDiskDrive (A9898A) 15 BNAB461-69001AB461-64001146GB,15KRPMUltra320SCSIDiskDrive (AB581A) 15 BNA7384-690010950-4532E0300GB,10KUltra320SCSILPDiskDrive (AD049A) 15 Fans AYN/AA7231-04014Assembly,Super80mmFan(Fan1a/1b)6 AYN/AA7231-04015Assembly,Thin80mmFan(Fan2)7 NN/AA7231-04033Assembly,Dualfan(Fan3)8 NN/AA7231-04017Assembly,Standard80mmFanN/A Processors BYA7138-69002A7138-67002Dual800MHzPA-RISCCPUwith32MBL2 Cache(A7138-62002)(A7138A) 5 BYAB534-69001AB534-62001Dual800MHzPA-RISCCPUwith64MBL2 Cache(A9952A,A9954A)(AB534A) (RequiresPDCgreaterthan44.52) 5 BYAB354-69001AB254-67001Dual1GHzPA-RISCCPUwith32MBL2 Cache(AB354-62001)(AB354A) 5 BYAB535-69001AB535-62001Dual1GHzPA-RISCCPUwith64MBL2 Cache(A9953A)(AB535A)(RequiresPDC greaterthan44.52) 5 196ReplacementParts
TableA-2ReplaceablePartsList(continued) CustomerSelf Repair PartNumber Exchange PartNumber Replacement DescriptionItem No. NN/A5069-5441ProcessorToolKitN/A PowerSupply NA6874-69000A6874-63000PowerSupply,650Watts,Redundant (A6874A) 10 CYN/A0950-4294Assembly,PowerPod4 Battery N/A1420-0386SystemBattery(BR2330)N/A N/AN/AiLOMPCardBattery(BR2032)N/A PedestalandRackSolutionKits NN/AA7231-04028DesksidePedestal27 N/AN/AA7231-04054Assembly,DesksideFrontPanel26 N/AN/AA7231-40052DesksideTopPanel24 AYN/AA7231-04051Assembly,DesksideSidePanel25 N/AN/A5064-9670FieldRackKit,SlideMidWeight(AB241A)N/A N/AN/A5065-5963FieldRackKit,CableManagementArm (AB241A) N/A RackServer NN/AA7231-04023Server,Assembly—RackLatchRight28 NN/AA7231-04053Server,Assembly—RackBezelRight29 AYN/AA7231-04068Server,Assembly—RackLeftBezelwith RackLatch 30 PlasticandMetalParts AYN/AA7231-40027Filler,SlimlineCarbonN/A AYN/AA7231-40026Filler,SlimlineGrayN/A AYN/AA6198-60003HDDFiller,CarbonN/A AYN/AA6198-60002HDDFiller,GrayN/A BYN/AA7231-04004Assembly,FanCageN/A BYN/AA7231-04006Assembly,PCICardCage16,18 AYN/AA7231-04034Assembly,PlasticTurbocoolerDuct3 AYN/AA7231-00072ECICoverPlateN/A AYN/A0515-2721Screw,M3x0.5x6mmLongwithTorx-T15 Recess N/A AYN/AA7231-04003Assembly,TopCover1 AYN/AA7231-04049Assembly,MemoryAirFlowGuideN/A Cables AYN/AA7231-63002IDECableN/A AYN/AA7231-63003StatusPanelCable11 ReplaceablePartsList197
TableA-2ReplaceablePartsList(continued) CustomerSelf Repair PartNumber Exchange PartNumber Replacement DescriptionItem No. AYN/AA7231-63004DiskPowerN/A AYN/AA7231-63017Cable,SCSI,ChannelA20 AYN/AA7231-63018Cable,SCSI,ChannelB21 AYN/AA7231-63005Cable,Super80mmFanN/A AYN/AA7231-63006Cable,80mmFanN/A AYN/AA7231-63024Single-ChannelInternalSCSICableN/A AYN/AA7231-63025Dual-ChannelInternalSCSICables(2)N/A AYN/AA6144-63001iLOMPCardMCableN/A BYN/AA7231-63008FlexCablefortheiLOMPCardN/A AYN/A8121-0808AudioCableN/A AYN/A5183-9500HeadphoneN/A AYN/A8120-1378PowerCordU.S.Canada125VACN/A AYN/A8120-1689PowerCordCont.Europe250VACN/A AYN/A8120-8376Chinesepowercord,straightN/A AYN/A8120-4753PowerCordJapan125VACN/A AYN/A8120-2104PowerCordSwitzerland250VACN/A AYN/A8120-1351PowerCordU.K.250VACN/A BYA6828-69001A6828-60101Single-ChannelUltra160SCSI Adapter(A6828A) N/A BYA6829-69001A6829-60101PCI4X2-ChannelUltra160SCSIAdapter (A6829A) N/A BYA6795-69001N/AFibreChannelCard,2Gb,Single-Port (A6795A) N/A BYA5838-69101A5838-60101PCI2-Port100Base-TUltra2SCSI(A5838A)N/A BYA6826-69001A6826-60001PCI-XDual-Channel2GbFibreChannel HBA(A6826A) N/A BYA5506-69102A5506-60102PCILANAdapter,4-Port100Base-TX (A5506B) N/A BYnoneA6847-67101LANAdapter,1000SXGigabit,NextGen (A6847A N/A BYnoneA6825-67101LANAdapter,1000TXGigabit,NextGen (A6825A) N/A BYN/AN/ASingle-Port100BaseTXLANAdapter(RJ-45, HalfLength)(A5230A) N/A BYA5513-69002A5513-60001PCIATM155MBpsMMFAdapter (A5513A) N/A BYA3739-69002N/AFDDIDualAttachStationLANAdapter (A3739B) N/A BYA5783-69101A5783-60101PCITokenRing4/16/100HardwareAdapter (A5783A) N/A 198ReplacementParts
BUtilities Thisappendixdescribesthebootconsolehandler(BCH)utilitythatispartoftheserver. High-levelinformationisalsoprovidedoniLOMP.ForcompleteinformationontheiLOMP, seetheHPIntegrityandHP9000iLOMPOperationsGuideontheHPwebsiteathttp:// h20000.www2.hp.com/bizsupport/TechSupport. BootConsoleHandler TheBCHuserinterfaceprovidestheinterfacebetweenyouandthefirmwarethroughthemenus andsimplecommands. TheBCHisseparatecodeinprocessor-dependentcode(PDC).TheBCHcodehastwopurposes: •Enablesthebootstrapcodetoknowwhichpathtobootfrom. •EnablesyoutointeractwithPDCtoviewandmodifyasetofspecificsystemparameters. BootingisstandardforPARISC,butcanbetransparentdependingonthestateoftheautoflags (boot, search,andstart).Iftheautoflagsareclearandyouoverrideautobooting,aboot sequenceendsintheinteractiveportionofBCHwheremodificationandviewingofsomesystem parametersispossible. NOTE:Whentheautostartflagisoff,autobootsareinterruptedifaconfigurationchange occurs,whichcausesreducedperformance.Therefore,youmustintervenebeforebootingtothe internalsystemloader(ISL). TheautoboothaltsattheBCHprompt.Continuebootingbyenteringboot. BCHCommands ThePDCuserinterfaceprovidesthefollowingtypesofcommands: UserCommandsRelatetocommonsystemmanagementoradministrationtaskssuch asconfigurationorboot. ServiceCommandsAvailabletoqualifiedservicepersonnel.Theservicecommandsare generallyusedtoaccessinformationaboutfaultsthatoccurwhilethe systemisrunning. TableB-1showstheBCHMainMenu,submenusandcommands.Examplesareprovidedin “BCHMainMenuCommandsandSubmenus”(page200). TableB-1BCHMainMenu,Submenus,andCommands DescriptionSubmenu Bootsfromthespecifiedpath.Boot [PRI|ALT|] Displaysormodifiesapath.Path [PRI|ALT] [] Searchesforbootdevices.Search [DIsplay|IPL] [] Displaysorsetsbootvalues.Configuration menu Displayshardwareinformation.Information menu Displaysservicecommands.Service menu Redisplaysthecurrentmenu.Display Displayshelpformenuorcommand.Help [| Restartsthesystem.Reset BootConsoleHandler199
Thebootdevicepathsspecifytheprimarybootdevice(PRIbootpath),thehigh-availability alternatedevice(HAAbootpath),andthealternatedevice(ALTbootpath). TableB-2liststhebootpaths. TableB-2BootPaths BootPathBootSource 0/1/1/0.0.0(SimplexMode)0/1/1/1.0.0(DuplexMode)BottomDisk–Slot1(SCSIID=0) 0/1/1/0.1.0(DuplexMode)TopDisk–Slot2(SCSIID=1) 0/0/3/0.0DVD BCHMainMenuCommandsandSubmenus Thefollowingsectionsprovideinformationandexamplesofthesubmenusandcommandsin theBCHfirmwareuserinterface. TheBCHMainMenuisthefirstmenudisplayedwhenyouenterthefirmwareuserinterface. Theothermenusavailablearelistedinthismenu.EnterDI(display)toviewthecommands availablefromthismenu. Accessothermenusbyenteringthenameofthemenuatthecommandprompt.Fromagiven menu,youcanrunacommandfromanyothermenubyenteringthemenunamethatisassociated withthecommand,followedbythecommand.Forexample,toruntheTI(time)command(in theConfigurationmenu)fromtheMainMenu,enterco ti.Toseeallavailablecommands listedundertheirrespectivemenus,enterHE(help)MA(main). ExamplescreenoutputoftheBCHMainMenu: ---- Main Menu --------------------------------------------------------------- Command Description ------- ----------- BOot [PRI|ALT|] Boot from specified path * PAth [PRI|ALT|CON|KEY] [] Display or modify a path SEArch [DIsplay|IPL] [] Search for boot devices COnfiguration menu Displays or sets boot values INformation menu Displays hardware information SERvice menu Displays service commands DIsplay Redisplay the current menu HElp [|] Display help for menu or command RESET Restart the system---- Main Menu: Enter command or menu > *Youcannotmodifythekeyboardpath. BootCommand UsetheBO(boot)commandtoinitiatethebootsequencefromanymenuintheinterface.You canentereitheradefaultorspecifiedpathtothebootdevice.Thispathmustbethedefinition ofadevice,forexample,FWSCSI.6.0orPRI.ThedefaultisPRI. PathCommand ThePA(path)commanddisplaysorsetsthecurrentpaths.Invokedwithonlyoneargument,PA displaysthecurrentpathoftheentitypassedasargument.Forexample,path altdisplaysthe currentalternativebootpath,andpath pri fwscsi.6.0setsuptheprimarybootpathas thedeviceattachedtoSCSIcontrollerwithID6andLUN0.Youcanalsosetanddisplaythe pathsofconsole(graphics/serial)andkeyboard.Forexample: Main Menu: Enter command or menu > pa Primary boot path: intscsia.1 200Utilities