    3.3.6 Inserting and removing the parameter modules
    1. Align the module with  the insertion guides 
    2. Push the module into the monitor frame until it stops.
    3. Pull the module outwards . Make sure not to drop it when it comes out.
    WARNINGWhen detaching modules, be careful no t to drop them. Always support with 
    one hand while pulling  out with the other.
    NOTE: Only one E-PSM(P) module and one N-F(C)(REC) module can be attached to S/5 FM. 
    NOTE: If you want to install  both modules, you must inst all the FM Extension Module, 
    (N-F(C)(REC) first and attach the E-PSM(P) module to it.
    3.3.7 Downloading Monitor Software F-FM(W)-00
    The following instructions apply to downloading of  new monitor software in case of upgrade or 
    service. Detailed instructions  for downloading software are supplied with software PCMCIA 
    cards.
    NOTE: All user settings will be lost afte r downloading of new monitor software.
    NOTE: During the downloading of software, the serial number of the monitor is written on the 
    software card. The software can then be down loaded again to the same monitor, but not to 
    any other monitor.
    1. Make sure the monitor  is switched to standby.
    .
    2. Open the cover for card drive slot. Insert the software card into the card drive slot and 
    press the software card firmly into its place.
    123
    130
    s e c2 
    						
    							Datex-Ohmeda S/5 FM
    24
    Document no. M1187317-009
    3. Switch the monitor on.
    4. Wait for approximately 80 seconds. After the normal screen appears, enter the service 
    menu and make sure that the information regarding monitor software has been updated. 
    Memorize the serial number of new software.
    5. Remove the software card.
    6. Replace the original device plate for monitor software by the new one supplied with the  software card.
    7. Perform Factory Reset. Make  sure that the monitor functions normally after the restart.
    8. Set the time and date (
    Monitor Setup -   Time And Date ).
    9. Set the monitor’s network co mmunication according to the used network software, if 
    necessary.
    The communication is set in the monitor’s  Network service menu:
    Monitor Setup - Install/Service   (password 16-4-34) -  Service (password 26-23-8)  - Frame – 
    Network  
    Network software S-CNET01 -> DRI Level = 2001
    Network software S-CNET02 -> DRI Level = 2001 or 2002 (WLAN)
    Network software L-NET03 -> DRI Level = 2003
    Network software L-NET05 -> DRI Level = 2003
    NOTE:  If the DRI level is changed, the  monitor will restart automatically.
    10. Fill out all necessary documentatio n regarding the new monitor software.
    NOTE: The license agreement of monitor software  needs to be in accordance with the monitor 
    software serial number. Make sure you archive the license agreement in a secure location.
    NOTE: The first start-up after software loading takes considerably longer. 
    3.3.8 Downloading Monitor Software, F-FM(W)-01
    See “Software Download Tool - User Instructions.”
    Software Download Tool, L-SWDL, is the on ly way to download/replace software on 
    F-FM(W)-01 frame by a field engineer. SWDL is a  service tool that enables the installation of 
    monitor service software from personal comp uter into legacy Datex-Ohmeda patient monitor.
    2
    80
    sec
    5 
    						
    							 System installation25
    Document no. M1187317-009
    3.3.9 Performing Factory Reset
    NOTE: The Factory Reset is necessary after  downloading of monitor software and after 
    replacing the CPU board or SRAM/Timekeeper battery.
    NOTE: The Factory Reset will restore all your customized defaults, includ ing language selection, 
    to factory defaults.
    1. Press the 
    Monitor Setup key.
    2. Select  Install/Service  and password (16-4-34).
    3. Select  Service and password (26-23-8).
    4. Select  Set/Test and perform  Factory Reset .
    5. The monitor will perform an automatic restart. After th e restart is completed, restart the 
    monitor also manually by the On/Standby switch.
    3.3.10 Installing the Datex-Ohmeda Wire less Network Upgrade, U-FMW (F-FM-00)
    The following instructions apply to upgrading th e monitor with the Wireless Network Upgrade. 
    Detailed upgrade instructions are supplied with the corresponding product.
    NOTE: You can download the option software only  to one monitor. During the downloading of 
    the option software, the serial number of the monitor is written on the software card, and if the 
    downloading for some reason would fail, the software can be downloaded again.
    1. Make sure that the monitor is switched to STANDBY.
    2. Open the cover for the card drive slot (on the left side of the monitor). Insert the option  software card into the card drive slot and  press the software card firmly in position.
    3. Switch the monitor ON.
    4. Wait until the normal screen appears and check that the message Field upgrade OK is  displayed as a note of successful upgrade.
    5. Remove the option software card.
    6. Switch the monitor to STANDBY.
    7. Disassemble the monitor in order to access the second PC card drive slot on the monitor  CPU board. 
    NOTE: Follow instructions in  the S/5 Frame for FM slot for disassembling the monitor.
    8. Insert the WLAN interface card into the PC card drive slot.        
    9. Connect the WLAN antennas to the handle guide. 
    						
    							Datex-Ohmeda S/5 FM
    26
    Document no. M1187317-009
    10. Connect the WLAN antennas to the WLAN interface card. Secure the antennas to the PC card drive slot with the holder included in the upgrade kit.
    11. Reassemble the monitor.
    NOTE: When reassembling the monitor make sure th at the tips of the WLAN halfwave antennas 
    do not get pinched between the monitor covers.
    12. Switch the monitor ON.
    13. Enter the service menu and make sure that the option software was downloaded 
    successfully (
    Monitor Setup –Install/Service (16-4-34) – Service (26-23-8) – Frame):
    Options = ”WLAN”
    14. Enter the WLAN Configuration service menu (
    Monitor Setup –Install/Service (16-4-34) – 
    Service (26-23-8) – Frame -  Network – WLAN – WLAN Config ).
    Enter the appropriate  Network ID, WEP Algorithm , Key ID  and Encryption Key  using the 
    corresponding menu selections.
    For selecting allowed communication channels, enter the appropriate  Channel Mask 
    using the corresponding menu selection.
    See  Appendix C. Channel Mask Selections for S/5 FM .
    Save the monitor’s wireless LA N configuration by selecting Save Configuration - Save.
    NOTE: The settings must match up with the ones that are defined in the Access Point 
    configuration. Refer to the rela ted site configuration document ation for correct settings, if 
    necessary.
    15. Attach the RLAN card sticker above the device plate at the monitor rear panel.
    If the monitor is located in Czech Rebublic,  Hong Kong, Poland, Singapore, Taiwan, South 
    Africa or South Korea, attach also the corr esponding country sticker (delivered with the 
    WLAN interface card) to the place that is indicated with a dashed line on the RLAN card 
    sticker. 
    						
    							 System installation27
    Document no. M1187317-009
    16. Enter the Network Status service menu (Monitor Setup –Install/Service (16-4-34) – 
    Service (26-23-8) – Frame - Network – Network Status ).
    Check that the Virtual ID sticker that is supplied with the Wireless Network upgrade, 
    U-FMW corresponds with the  Location ID that is displayed in the menu.
    NOTE: The Location ID is the monitor’s ID on the Datex-Ohmeda Network and cannot be 
    changed.
    17. Attach the Virtual ID sticker above the RLAN card sticker at the monitor rear panel.
    18. Configure the monitor’ s Location ID in the S/5 Central Network setup.
    NOTE: Refer to the Datex-Ohmeda S/5 Central, ViewStation and Network Technical Reference 
    Manual for information about th e configuration, if necessary.
    19. Check that the monitor connects to the Datex-Ohmeda Wireless Network: - the wireless LAN network symbol is displayed on the monitor screen
    - the S/5 Central is listed in the monitor’s Network Status service menu
    - monitor data can be displayed on the S/5 Central
    Wireless LAN network symbol on the S/5 FM monitor
    20. Fill out all necessary documentation regarding the upgrade.
    3.3.11 Installing the Datex-Ohmeda Wire less Network Service Option, N-FMWS 
    (F-FM-00)
    The following instructions apply to upgrading  the monitor with the Wireless Network Service 
    Option. Detailed upgrade instructions are supplied with the corresponding product.
    NOTE: You can download the option software only  to one monitor. During the downloading of 
    the option software, the serial number of the monitor is written on the software card, and if the 
    downloading for some reason would fail, the software can be downloaded again.
    1. Make sure that the monitor is switched to STANDBY.
    2. Open the cover for the card drive slot (on the left side of the monitor). Insert the option  software card into the card drive slot and  press the software card firmly in position.
    3. Switch the monitor ON.
    4. Wait until the normal screen appears and check that a message Field upgrade OK is  displayed as a note of successful upgrade.
    5. Remove the option software card.
    6. Enter the service menu and make sure that the option software was downloaded  successfully (
    Monitor Setup –Install/Service (16-4-34) – Service (26-23-8) – Frame ):
    Options  = ”WLAN”
    7. Enter the WLAN Configuration service menu (
    Monitor Setup –Install/Service (16-4-34) – 
    Service (26-23-8) – Frame -  Network – WLAN – WLAN Config ).
    Enter the appropriate  Network ID, WEP Algorithm , Key ID  and Encryption Key  using the 
    corresponding menu selections.
    For selecting allowed communication channels, enter the appropriate  Channel Mask 
    using the corresponding menu selection. 
    						
    							Datex-Ohmeda S/5 FM
    28
    Document no. M1187317-009
    See Appendix C. Channel Mask Selections for S/5 FM .
    Save the monitor’s wireless LA N configuration by selecting Save Configuration - Save.
    NOTE: The settings must match up with the ones that are defined in the Access Point 
    configuration. Refer to the rela ted site configuration document ation for correct settings, if 
    necessary.
    8. Enter the Network Status service menu (
    Monitor Setup  –Install/Service (16-4-34) – 
    Service (26-23-8) – Frame - Network – Network Status ).
    Check that the Virtual ID -sticker that is supplied with the Wireless Network upgrade, 
    U-FMW corresponds with the  Location ID that is displayed in the menu.
    NOTE: The Location ID is the monitor’s ID on the
      Datex-Ohmeda Network and cannot be 
    changed.
    9. Attach the Virtual ID sticker above the RLAN card sticker at the monitor rear panel.
    10. Configure the monitor’ s Location ID in the S/5 Central Network setup.
    NOTE: Refer to the Datex-Ohmeda S/5 Central, ViewStation and Network Technical Reference 
    Manual for information about th e configuration, if necessary.
    11. Check that the monitor connects to the Datex-Ohmeda Wireless Network: - the wireless LAN network symbol is displayed on the monitor screen
    - the S/5 Central is listed in the monitor’s Network Status service menu
    - monitor data can be displayed on the S/5 Central
    Wireless LAN network symbol on the S/5 FM monitor
    12. Fill out all necessary documentation regarding the upgrade.
    3.3.12 Installing the S/5 Wire less Network Upgrade, U-FMW-01
    The following instructions apply to upgrading  the monitor with the Wireless Network Upgrade.
    Detailed upgrade instructions are supplied with the corresponding product.
    1. Perform main software upload to th e monitor using Software Download Tool.
    NOTE: Follow Software Download Tool  User Instructions, if necessary. 
     When generating the license key use N-FMW as an option.
     Use the Virtual ID number that is supplied with the Wireless Network Upgrade, 
    U-FMW-01 package to avoid ID conflict in the network.  
    						
    							 System installation29
    Document no. M1187317-009
    After the patient monitor has restarted fo r the first time after monitor software 
    reinstallation, perform a factory reset to the patient monitor. 
    2. Enter the service menu and make sure that  the WLAN option was activated successfully 
    (
    Monitor Setup - Install/Service (16-4-34) - Service (26-23-8) - Frame) :
    Options = WLAN
    3. Switch the monitor to STANDBY.
    4. Disassemble the monitor in order to access the Compact Flash card drive slot on the  monitor CPU board.
    NOTE: Follow instructions in th e S/5 Frame for FM slot for disassembling the monitor, if 
    necessary.
    5. Insert the WLAN interface card into the Compact Flash card drive slot.
    6. Connect the WLAN antennas to the handle guide. 
    7. Connect the WLAN antennas to the WLAN interface card. Secure the antennas to the  Compact Flash card drive slot with the holder included in the upgrade kit.
    8. Reassemble the monitor.
    NOTE: When reassembling the monitor make sure th at the tips of the WLAN halfwave antennas 
    do not pinch between the monitor covers.
    9. Switch the monitor ON. 
    						
    							Datex-Ohmeda S/5 FM
    30
    Document no. M1187317-009
    10. Enter the WLAN Configuration service menu (Monitor Setup -Install/Service (16-4-34) - 
    Service (26-23-8) - Frame - Network - WLAN - WLAN Config).
    Enter the appropriate  Network ID, WEP Algorithm,  Key ID and Encryption Key  using the 
    corresponding menu selections.
    For selecting allowed communication channels, enter the appropriate  Channel Mask 
    using the corresponding menu selection. See  Appendix C. Channel Mask Selections for S/5 
    FM .
    Save the monitors wireless LA N configuration by selecting Save Configuration - Save.
    NOTE: The settings must match up with the ones that are defined in the Access Point 
    configuration. Refer to the rela ted site configuration document ation for correct settings, if 
    necessary.
    11. Attach the RLAN card sticker above the device plate at the monitor rear panel.
    If the monitor is located in Czech Rebublic,  Hong Kong, Poland, Singapore, Taiwan, South 
    Africa or South Korea, attach also the corr esponding country sticker (delivered with the 
    upgrade package) to the place that is indicated with a dashed line on the RLAN card 
    sticker. 
    12. Enter the Network Status service menu (
    Monitor Setup -Install/Service (16-4-34) - 
    Service (26-23-8) - Frame - Network - Network Status ).
    Check that the Virtual ID -sticker that is supplied with the Wireless Network upgrade, 
    U-FMW corresponds with the  Location ID that is displayed in the menu.
    NOTE: The Location ID is the monitors ID  on the S/5 Network and cannot be changed.
    13. Attach the Virtual ID -sticker above the RLAN card sticker at the monitor rear panel.
    14. Configure the monitors Location ID in the S/5 Central Network setup.
    NOTE: Refer to the Datex-Ohmeda S/5 Central, ViewStation and Network Technical Reference 
    Manual for information about th e configuration, if necessary.
    15. Check that the monitor connec ts onto the S/5 Network wireless:
     the wireless LAN network symbol is displayed on the monitor screen
     the S/5 Central is listed in the monitors Network Status service menu
     monitor data can be displayed on the S/5 Central    
    16. Fill out all necessary documentation regarding the upgrade.                           Wi
    reless LAN network symbol on the S/5 FM monitor 
    						
    							 System installation31
    Document no. M1187317-009
    3.4 Remote Controller, K-CREMCO
    To connect a Remote Controller, K-CREMCO to  S/5 FM plug the connector to the 5-pin DIN 
    connector X7 in Multi I/O adapter at the back of the monitor.
    3.5 Visual indicators
    Function Specification             Explanation
    External power supply Green LED Indicates when monitor is powered from 
    mains or ext. DC (External DC power for 
    future use)
    Battery operation  Green LED Indicates when monitor is powered from 
    internal batteries
    Battery condition  Orange LED  Indicates when monitor is charging 
    batteries (solid) or battery failure, one or 
    both batteries missing (flashing). 
    Alarm LEDs Red LED Indicates a life threatening situation
    Yellow LED Indicates seriou s but not life threatening 
    problems
    Alarm Light Highly visible Red/ 
    Yellow light    Ease alarm detection from distance.  Brightness of the light and enabling the 
    alarm light function are user configurable. 
    3.6 Troubleshooting
    If a problem occurs during the functional exam ination, check the components of the monitor 
    according to the following troubleshooting chart.  If the problem persists, please refer to the 
    part II.
    Problem What to do
    Nothing functions Unplug and re-plug Remote Controller Cable. Also confirm that the cable is intact. Unplug and re-plug the Power Cord. Also confirm that the cable is intact.
    Confirm that the fuses are intact.
    E-PSM(P) module does 
    not function Remove and replace the module.
    Confirm that the desired parameters are configured to be displayed.
    N-F(C)(REC) module does 
    not function Confirm that ‘Occlusion’ or ‘Calibrating Gas Sensor’ messages are not displayed.
    Confirm that a D-fend water trap and a sample tube are attached.
    Confirm that the desired parameters are configured to be displayed.
    Remove and replace the module. 
    						
    							Datex-Ohmeda S/5 FM
    32
    Document no. M1187317-009
    4 Interfacing
    External devices can be interfaced with the S/5 FM via the monitors serial port and via the 
    Device Interfacing So lution, N-DISxxx.  
    Printers and computers can be interfaced via the monitor’s serial port.
     
    Device specific N-DISxxx modules can be used with:
    •Monitors
    •Blood-gas analyzers
    NOTE: The Device Interfacing Solution, N-DISxxx th at is used on the S/5 FM must be of revision 
    01 or later.
    4.1 Interfacing external bedside devices via Device 
    Interfacing Solutions, N-DISxxx
    The Device Interfacing Solution, N-DISxxx prov ides means for transferring physiological, 
    waveform and event data from various bedside patient care devices to the Datex-Ohmeda 
    monitoring system. The real-time and trended data can be displayed on the monitor screen 
    and used for record keeping purposes. The interfacing module reads the data coming from the 
    external device, converts it to a suitabl e format and sends it to the monitor. 
    See the following table of DIS modules and devi ces that you can interface with the Device 
    Interfacing Solution.
    Table 4 DIS modules and interfaced devices 
    For specific information on parameters tran sferred from the interfaced device to the 
    Datex-Ohmeda monitor and the applicable softwa re versions of the device refer to the 
    Installation guide accompanying each DIS module. 
    Device Monitors
    N-DISOXIM3 Oximetrix 31
    1 Trademark of Hospira Inc. (previously  trademark of Abbott Laboratories)
    N-DISQVUE
    QVue /Q2
    1 
    N-DISVIGIL Baxter-Vigilance
    2 
    2 Trademark of Edwards Lifesciences Corporation
    Device Blood gas analyzers
    N-DISOPT Osmetech Opti CCA1
    1 Trademark of Osmetech plc 
    						