GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-10 - Renewal Parts List for BT03 or lower 9-85 764- 2PC CABLE2 ASSY2358656 for OC 235xxxx/238xxxx (Ver2/Ver3) CB012 (J10 MDCON Int-housing lock in BECOMP J006) 575mm CB012 (J10 MDCON PC2IO D-Sub J2) 600mm CB014 (J11 MDCON BECOMP Audio mini Jack1 ) 540mm CB015 (RS232 BECOMP Modem RS232 ) 1000mm CB016 (Ethernet BECOMP REAN J10) 400mm USB CB018 (USB#2 BECOMP REAN USB Hub) 1000mm DVI-D CB019A (VGA BECOMP DGVIC J3) 450mm UPS CB020 (RS232 BECOMP UPS RS232) 500mm SCSI CB035 (J1 PC2IO REAN J9) 520mm Modem CB040(J14 REAN Modem Line) 950mm CB044 (J12 MDCON REST J10) 270mm CB047A (J8 MDCON Int-housing lock J042) 1100mm/100mm 12 764-3PC CABLE ASSY 2298147for OC 22xxxxx/230xxxx (Ver1) CB012 (J10 MDCON Int-housing lock in BECOMP J006) 575mm CB012 (J10 MDCON PC2IO D-Sub J2) 710mm CB014 (J11 MDCON BECOMP Audio mini Jack1 ) 640mm CB015 (RS232 BECOMP Modem RS232 ) 1000mm CB016 (Ethernet BECOMP REAN J10) 340mm USB CB018 (USB#2 BECOMP REAN USB Hub) 820mm DVI-D CB019A (VGA BECOMP DGVIC J3) 410mm UPS CB020 (RS232 BECOMP UPS RS232) 500mm SCSI CB035 (J1 PC2IO REAN J9) 570mm Modem CB040(J14 REAN Modem Line) 890mm CB044 (J12 MDCON REST J10) 270mm CB047A (J8 MDCON Int-housing lock J042) 1100mm/100mm 12 Table 9-50 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-86Section 9-10 - Renewal Parts List for BT03 or lower 765- 1POWER CABLE ASSY 2383142for OC 238xxxx (Ver3) CB201 (P2 HV Mother P15, P16, P17) 850mm/ 690mm/630mm CB202 (P1 HV MDCON J18) w/Ferrite Core 480mm CB205-1 (+6V/0V LV Mother P3, P4 ) w/Ferrite Core 850mm/850mm CB205-2 (+6V/0V LV Mother P5, P6 ) w/Ferrite Core 810mm/810mm CB206 (-6V/0V LV Mother P7 ) 700mm CB207 (+5V/0V LV Mother P8 ) 700mm CB208-1A (+3.3V/0V LV Mother P10 ) 680mm CB208-2A (+3.3V/0V LV Mother P11 ) 680mm CB209 (+12V/0V LV Mother P13 ) 700mm CB210 (-12V/0V LV Mother P12 ) 700mm CB230-1 (Int-housing lock in KBD Mother P1, P2 ) 520mm/540mm CB231 (Cooling FAN Mother P14 ) 800mm 12 765- 2POWER CABLE ASSY 2359541for OC 235xxxx/238xxxx (Ver2/Ver3) CB201 (P2 HV Mother P15, P16, P17) 950mm/ 790mm/720mm CB202 (P1 HV MDCON J18) 750mm CB205-1 (+6V/0V LV Mother P3, P4 ) 810mm/ 810mm CB205-2 (+6V/0V LV Mother P5, P6 ) 810mm/ 810mm CB206 (-6V/0V LV Mother P7 ) 700mm CB207 (+5V/0V LV Mother P8 ) 700mm CB208-1A (+3.3V/0V LV Mother P10 ) 680mm CB208-2A (+3.3V/0V LV Mother P11 ) 680mm CB209 (+12V/0V LV Mother P13 ) 700mm CB210 (-12V/0V LV Mother P12 ) 700mm CB230-1 (KBD1 Int-housing lock in KBD Mother P1, P2 ) 1920mm/1920mm CB231 (Cooling FAN Mother P14 ) 850mm 12 Table 9-50 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-10 - Renewal Parts List for BT03 or lower 9-87 765- 3POWER CABLE ASSY2298148 for OC 22xxxxx/230xxxx (Ver1) CB201 (P2 HV Mother P15, P16, P17) 950mm/ 790mm/720mm - non core CB202 (P1 HV MDCON J18) 750mm CB205-1 (+6V/0V LV Mother P3, P4 ) 810mm/ 810mm CB205-2 (+6V/0V LV Mother P5, P6 ) 810mm/ 810mm CB206 (-6V/0V LV Mother P7 ) 700mm CB207 (+5V/0V LV Mother P8 ) 700mm CB208-1 (+3.3V/0V LV Mother P10 ) 680mm Contact CB208-2 (+3.3V/0V LV Mother P11 ) 680mm Contact CB209 (+12V/0V LV Mother P13 ) 700mm CB210 (-12V/0V LV Mother P12 ) 700mm CB230-1 (Int-housing lock in KBD Mother P1, P2 ) 1920mm/1920mm CB231 (Cooling FAN Mother P14 ) 850mm 12 766-1BAY CABLE32361023-2CB302A (P401 ATX PS 5 inch Bay J403/J404 ) 800mm/220mm12 766-2BAY2 CABLE2401408CB022A (P001 BECOMP MOD J002) 1500mm12 767-1OP2 CABLE2 ASSY 2383141for OC 238xxxx (Ver3) CB027B (CN31 OP PNL Int-housing lock under KBD P017 ) 1090mm CB029B (CN18 LCD Int-housing lock under KBD D-Sub P021) 950mm CB230-2 (CN21 OP PNL Int-housing lock under KBD Power Cable KBD1) 1000mm USB CB025A (CN18 OP PNL Int-housing lock in KB support Assy P011) CB026B (P014 Int-housing lock in KB support assy Int-housing lock under KB TRAY P016+P046) CB308B (CN23 OP PNL Int-housing lock under KB TRAY P416) 690mm GND CB312 (T210 OP PNL Main Frame T211) 700mm CB309B (CN22 OP PNL Int-housing lock KB TRAY P407B) 690mm 12 767- 2OP2 CABLE2 ASSY 2359767for OC 235xxxx/238xxxx (Ver2/Ver3) CB027B (CN31 OP PNL Int-housing lock under KBD P017 ) 1130mm CB029B (CN18 LCD Int-housing lock under KBD P021) 900mm CB230-2 (CN21 OP PNL Int-housing lock under KBD Power Cable KBD1) 1000mm GND CB312 (T210 OP PNL Main Frame T211) 700mm 12 Table 9-50 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-88Section 9-10 - Renewal Parts List for BT03 or lower 767- 3OP CABLE2 ASSY 2302191for OC 22xxxxx/230xxxx (Ver1) USB CB025B (CN18 OP PNL Int-housing lock under KBD P011) 1000mm CB027B (CN31 OP PNL Int-housing lock under KBD P017 ) 1000mm CB029B (CN18 LCD Int-housing lock under KBD P021) 900mm CB230-2 (CN21 OP PNL Int-housing lock under KBD Power Cable KBD1) 1000mm GND CB312 (T210 OP PNL Main Frame T211) 700mm 12 768OP CABLE3 ASSY2304610-2 CB026C (P016+P046 Int-housing lock under KB TRAY Front PNL CN44) 130mm CB026C (P016+P046 Int-housing lock under KB TRAY Front PNL CN42) 130mm CB031B (Int-housing lock under Monitor P030 Front PNL CN41) 620mm 12 769PC2IO/IPCABLE ASSY2304611for OC 22xxxxx/230xxxx (Ver1) CB301 (PC2IO PC2IP ) 400mm12 770SYS AC CABLE ASSY2304612CB307A (J408 Int-housing lock under KBD Rear J409) 1200mm12 771- 1PWR AC CABLE ASSY 2383138for OC 238xxxx (Ver3) CB203 (TB3 SSR HV AC in ) 1050mm CB212 ( TB3 SSR LV AC in) 1700mm CB225 (TB2 SSR ATX AC in) 970mm 12 771- 2PWR AC CABLE ASSY 2304613for OC 22xxxxx/230xxxx/235xxxx/238xxxx (Ver1/ Ver2/Ver3) CB203 (TB3 SSR HV AC in ) 1050mm CB212 ( TB3 SSR LV AC in) 1700mm CB225 (TB2 SSR ATX AC in) 970mm CB305 (TB3 SSR Modem AC in) 1150mm 12 772PC BOX INTERNALCABLE ASSY 2304797 for OC 235xxxx/238xxxx (Ver2/Ver3) CB101 (J005 BECOMP Mother P-Seq-Jumper Int-housing lock in PC P006) 500mm CB102 (J105/J045 BECOMP Mother (Reset/HDD) Int-housing lock as PC BOX J076) 500mm12 -USB CABLE2358659-2CB025AA (USB1 BECOMP OP PNL CN18 ) 2600mm12 -USB DEV CABLE FOR PERIPHERAL DEVICE2388600-2 DVD unit - PC Box CB100 (USB4 BECOMP DVD Drive 5 inch bay USB ) 1250mm 12 778ECG INT CABLE ASSY2360884-2CB030A (Patient I/O DGVIC J8 ) 850mm12 779PCI CABLE 2389075 CB011 (PC2IP BECOMP MDBRG) 1 2 751FOOT SWITCHFB200952 Foot Switch (Option) 1 2 756PCG OPTION2326844 phono microphone (Option) 1 2 773USB SERIALBRIDGE CBL2304621Ext. Peripheral L712 774RS232C CABLE ASSY STRAIGHT2305549Ext. Peripheral L712 Table 9-50 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-10 - Renewal Parts List for BT03 or lower 9-89 775RS232C CABLE ASSY CROSS2305550-2Ext. Peripheral L712 776ECG CBL SHORT2304616 Ext. Patient L7 1 2 777ECG CBL LONG2304615 Ext. Patient L7 1 2 -US CABLE FOR PERIPHERAL DEVICE 2324360 Ext. Peripheral L7 1 2 -Keyboard Knob Repair kit236386112 -Strap with Buckle511585512 -Foot for peripheral231844112 -MON-CABLE-ASSY2304171 1 2 -Loopback Connector2116343 Loopback Connector for Diagnostics (46-330081P3) 1 2 Table 9-50 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-90Section 9-10 - Renewal Parts List for BT03 or lower 9-10-12 Probes 9-10-12-1 Probes for Country other than JAPAN Table 9-51 Probes for Country other than JAPAN ItemPart NamePart NumberDescriptionQtyFRU 801 3C PROBE (EXP) 2286354 1 802 3.5C PROBE (EXP) 2050357 1 803 5C PROBE (EXP) 2294516 1 804M7CMIH PROBE (EXP)22945141 805E8C PROBE (EXP)22946411 8067L PROBE (EXP)22945211 807 10L PROBE (EXP) 2294523 1 808 M12LMIH PROBE (EXP) 2294511 1 809 3S PROBE (EXP) 2323337 1 81010S PROBE (EXP)22985891 811I12L PROBE (EXP)22648831 812P2D PROBE (EXP)TE100024PPA adapter is separately required.1 813 P6D PROBE (EXP) TQ100002PPA adapter is separately required. 1 814 8C PROBE (EXP) 2348094 1 815 3.5CS PROBE (EXP) 2051858 1 8166T TEE PROBE (EXP)KN1000921 817M3S PROBE (EXP)23780991 818PPA ADAPTER2331934-21
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-10 - Renewal Parts List for BT03 or lower 9-91 9-10-12-2 Probes for Japan Table 9-52 Probes for Japan ItemPart NamePart NumberDescriptionQtyFRU 851 3C PROBE (JPN) 2286353 1 852 3.5C PROBE (JPN) 2348877 1 853 5C PROBE (JPN) 2294515 1 854M7CMIH PROBE (JPN)22945131 855E8C PROBE (JPN)22946401 8567L PROBE (JPN)22945201 857 10L PROBE (JPN) 2294522 1 858 M12LMIH PROBE (JPN) 2294510 1 859 3S PROBE (JPN) 2348878 1 86010S PROBE (JPN)23094781 861I12L PROBE (JPN)22705561 8628C PROBE23480931 863 3.5CS PROBE 2380854 1 864 6T TEE PROBE 5131947 1 865 M3S PROBE 2293726 1 866PPA ADAPTER2331934-21
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-92Section 9-10 - Renewal Parts List for BT03 or lower This page was intentionally left blank.
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 10-1 - Overview 10-1 Chapter 10 Periodic Maintenance Section 10-1 Overview 10-1-1 Purpose of Chapter 10 This chapter describes Periodic Maintenance (PM) on the scanner and its peripherals. These PM procedures are intended to maintain the quality of the ultrasound systems performance. Read this chapter completely and familiarize yourself with the procedures before starting a PM. CONTENTS IN CHAPTER 10 Table 10-1 Contents in Chapter 10 SectionDescriptionPage Number 10-1 Overview 10-1 10-2 Why do Periodic Maintenance 10-2 10-3 Periodic Maintenance Schedule 10-2 10-4Tools Required10-4 10-5System Periodic Maintenance10-7 10-6Using a Phantom10-11 10-7 Electrical Safety Tests 10-12 10-1 When Theres Too Much Leakage Current... 10-31 PM Inspection Certificate 10-29 CAUTIONPractice good ESD prevention. Wear an anti–static strap when handling electronic parts and even when disconnecting/connecting cables. DANGERTHERE ARE SEVERAL PLACES ON THE BACKPLANE, THE AC DISTRIBUTION, AND DC DISTRIBUTION THAT ARE DANGEROUS. BE SURE TO DISCONNECT THE SYSTEM POWER PLUG AND OPEN THE MAIN CIRCUIT BREAKER BEFORE YOU REMOVE ANY PARTS. BE CAUTIOUS WHENEVER POWER IS STILL ON AND COVERS ARE REMOVED. CAUTIONDo not pull out or insert circuit boards while power is ON. CAUTIONDo not operate this unit unless all board covers and frame panels are securely in place. System performance and cooling require this. CAUTION
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 10-2Section 10-2 - Why do Periodic Maintenance Section 10-2 Why do Periodic Maintenance 10-2-1 Keeping Records It is good business practice that ultrasound facilities maintain records of periodic and corrective maintenance. The Ultrasound Periodic Maintenance Inspection Certificate provides the customer with documentation that the ultrasound scanner is maintained on a periodic basis. A copy of the Ultrasound Periodic Maintenance Inspection Certificate should be kept in the same room or near the scanner. 10-2-2 Quality Assurance In order to gain accreditation from organizations such as the American College of Radiology (USA), it is the customer’s responsibility to have a quality assurance program in place for each scanner. The program must be directed by a medical physicists, the supervising radiologist/physician or appropriate designee. Routine quality control testing must occur regularly. The same tests are performed during each period so that changes can be monitored over time and effective corrective action can be taken. Testing results, corrective action and the effects of corrective action must be documented and maintained on the site. Your GE service representative can help you with establishing, performing and maintaining records for a quality assurance program. Section 10-3 Periodic Maintenance Schedule 10-3-1 How often should PMs be performed? The Periodic Maintenance Schedule specifies how often your LOGIQ™ 7 should be serviced and what items need attention. It is important you have your LOGIQ™ 7 serviced as scheduled in order to retain its high level of safety, dependability and performance. Your GE Service Representative knows your LOGIQ™ 7 best and can provide competent, efficient service. Please contact us for further information and to schedule GE Medical Systems Ultrasound to perform this service for you. The services and intervals shown in the maintenance schedule assumes that you use your LOGIQ™ 7 for an average patient load (10-12 per day) and not used as a primary “mobile unit”.