GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-9 - Renewal Parts List For BT04 and BT06 9-45 9-9-14 Power Units (cont’d) Table 9-33 Power Units ItemPart NamePart NumberDescriptionQtyFRU 701SSR ASSY 5117726SSR + CONNECTOR PCB 1 1 702FUSE HOLDER ASSY5117727Without fuse 1 1 702- 1FUSE 2315585 F1, 200V, T12V 1 1 -LV -04 UNIT5118824Obsolete. Cannot use this part any longer, and the parts in stock have been purged.-- 703LV UNIT ASSY MAIN PS L75118824-2low voltage regulator + Cable11 704HV UNIT2372387 high voltage regulator (Half height), including materials used when changing Full height HV unit to the Half height. 11 706AC CORD 100V US 2371417power cable of 100V, with clamp 1 1 706- 2AC CORD 100V JPN 2371416For JAPAN, power cable of 100V, with clamp 1 1 706- 3AC CORD 200V EU 2371418power cable of 200V, with clamp 1 1 706- 4AC CORD 200V China CCC2371415-2applied to Chaina CCC specifications11 708MAIN Transformer2373331-2power transformer11 707NF INLET Assy5117723Noise Filter + Inlet PCB11 705-1AC IN-OUT 100V 5117724 1 1 705- 2AC IN-OUT 200V 5117725 1 1 705- 3AC IN-200V OUT-100V 5118052For Korea1 1 711Connector Assy511772811 709CONSOLE FAN ASSY251174933 fans for BT04, BT0611 709CONSOLE FAN ASSY A5122614For upgrade BT04, upgrade BT0611 -AIR FILTER A5112530 UNDER NEST 1 2 -AIR FILTER B5112531UNDER PC BOX 1 2 -AIR FILTER C5115806UNDER RATING PLATE 1 2 -SSR-HLV CABLE5119119CB10711 -SSR-AC PANEL CABLE5119120CB10911 -VOLTAGE SEL CABLE5119121CB10811 -FAN CABLE BRAKET ASSY5117491 1 1 -AC Cord UK & Ireland5151455 1 2 -AC Cord Denmark5151457 1 2
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-46Section 9-9 - Renewal Parts List For BT04 and BT06 -AC Cord India & Africa515145012 -AC Cord Australian515145311 -AC Cord Argentina515145411 -AC Cord Israel 5151451 1 1 -AC Cord Swiss5151448 1 1 Table 9-33 Power Units ItemPart NamePart NumberDescriptionQtyFRU
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-9 - Renewal Parts List For BT04 and BT06 9-47 9-9-15 Options, Peripherals and Cables Figure 9-14 Options, Peripherals and Cables 1 y y y y y y 750 760 761 765 770 771772
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-48Section 9-9 - Renewal Parts List For BT04 and BT06 9-9-15 Options, Peripherals and Cables (cont’d) Figure 9-15 Options, Peripherals and Cables 2
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-9 - Renewal Parts List For BT04 and BT06 9-49 9-9-15 Options, Peripherals and Cables (cont’d) Figure 9-16 Options, Peripherals and Cables 3 Table 9-34 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU -CABLE DUCT ASSY 5117797Obsolete. Cannot use this part any longer, and the parts in stock have been purged. -- 750CABLE DUCT ASSY CSL L7 5117797-2Including: USB LAN CABLE ASSY (CB1.CB2.CB3.CB4.CB6.CB9) DSUB CABLE ASSY (CB10.CB13.CB16.CB17.CB22) DEVIDE CABLE ASSY (CB5.CB15.CB19.CB32) BW CABLE ASSY (CB7.CB18.CB20.CB31) AC CABLE ASSY (CB12.CB28.CB33.CB35) Felite core added for noise reduction 12 45 13 6 1112 25
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-50Section 9-9 - Renewal Parts List For BT04 and BT06 760PCI CABLE 2389075 MDBRG PC2IP2 1 2 761TX CABLE ASSY2305111-3QCON TRAP12 765PW SW ASSY2301858-3Power Switch, SW Bracket CB011 (PC2IP BECOMP MDBRG )12 770FCON Cable Assy5117485 CB36 (FCON DVD ) CB39 (FCON Removable Bay) CB37 (FCON OP Panel) CB38 (FCON OP Panel) 12 771LAMP STAY ASSY5117796Lamp Stay Bracket CB41 (OP Panel Lamp Stay) 12 772FOOT SW Bracket ASSY 5117795FOOT SWITCH BRACKET CB40 (OP Panel Foot SW Connector) 12 -FOOT SWITCH FB200952 Foot Switch (Option) 1 2 -PCG OPTION2326844phono microphone (Option)12 -USB SERIALBRIDGE CBL2304621Ext. Peripheral L712 -RS232C CABLE ASSY STRAIGHT2305549Ext. Peripheral L712 -RS232C CABLE ASSY CROSS2305550-2 Ext. Peripheral L7 1 2 -ECG CBL SHORT2304616 Ext. Patient L7 1 2 -ECG CBL LONG2304615 Ext. Patient L7 1 2 -US CABLE FOR PERIPHERAL DEVICE2324360Ext. Peripheral L712 -Keyboard Knob Repair kit236386112 -Strap with Buckle511585512 -Foot for Printer 2318441 1 2 -USB Conversion Adapter5129258B Type to A Type in Device room 1 2 -PAT, I/OFA200801 1 2 -MON-CABLE-ASSY230417112 44D-Mother2 Cable CSL L75138724For 4D Option11 54D Box cable Assy CSL L75138723For 4D Option 1 1 64D AC cable CSL L7 5147891For 4D Option 1 1 -Cable Bracket For 4D ECG 5145578For 4D Option 1 1 -Cable Bracket For 4D non-ECG5145579For 4D Option11 -4D Motor Controller2372904For 4D Option11 -Cable, Bracket to Probe2384183For 4D Option11 11Wireless Receiver5115162For Voice Scan Option 1 1 Table 9-34 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-9 - Renewal Parts List For BT04 and BT06 9-51 12Wireless Transmitter5116453For Voice Scan Option 1 1 13MIcrophone2383779For Voice Scan Option, Over-the-ear style11 -Rechargable Battery Pack for Transmitter5116454For Voice Scan Option11 -Battery recharger station5116446For Voice Scan Option11 22LOGIQ7 Ghost CD for BEP3, R6.5.0 5182424 Ghost (Base Image) CD for R65x1 1 23LOGIQ7 R6.5.0 Application Software CD Release 5181894Initial Release (M3). Related Ghost CD is 5182424. 11 24LOGIQ7 R6.5.1 Application Software CD5181894-2Apr . 07 Release (M4) - compatible to 5181894Related Ghost CD is 5182424.11 25BW PRINTER SHORT BOX FRU L75194980 For consoles V65x and afterward, Printer Box is “Short” type. Consoles with “Standard” type printer box, if not equipped with BW printer, can be converted to “Short” type using this FRU. 11 -LQ-MD800P5120592DVD Recorder, 120V AC (PAL/NTSC compatible)11 -LQ-MD800E 5120593 DVD Recorder, 220V AC (PAL/NTSC compatible) 1 1 Table 9-34 Options, Peripherals and Cables ItemPart NamePart NumberDescriptionQtyFRU
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-52Section 9-9 - Renewal Parts List For BT04 and BT06 9-9-16 Probes 9-9-16-1 Probes (For the country other than Japan) Table 9-35 Probes (For the country other than Japan) ItemPart NamePart NumberDescriptionQtyFRU 801 3C PROBE (EXP) 2286354 1 802 3.5C PROBE (EXP) 2296158 1 803 5C PROBE (EXP) 2294516 1 804M7CMIH PROBE (EXP)22945141 805E8C PROBE (EXP)22946411 8067L PROBE (EXP)22945211 807 10L PROBE (EXP) 2294523 1 808 M12LMIH PROBE (EXP) 2294511 1 809 3S PROBE (EXP) 2323337 1 81010S PROBE (EXP)22985891 811I12L PROBE (EXP)22648831 812P2D PROBE (EXP)TE100024PPA adapter is separately required.1 813 P6D PROBE (EXP) TQ100002PPA adapter is separately required. 1 814 8C PROBE (EXP) 2348094 1 815 3.5CS PROBE (EXP) 2051858 1 8166T TEE PROBE (EXP)KN1000681 817M3S PROBE (EXP)22956491 8187S PROBE (EXP)23474711 819 BE9C PROBE (EXP) 2389382 1 820 PPA adapter 2331934-2 1 821 T739 PROBE (EXP) 2259246 1 8224D10L (EXP)KTZ1568364D OPTION required.1 8234D3C_L (EXP)KTZ1958934D OPTION required.1 82412L PROBE (EXP)22953771 825 4C PROBE (EXP) 5123455 1
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 9-9 - Renewal Parts List For BT04 and BT06 9-53 9-9-16-2 Probes for Japan Table 9-36 Probes for Japan ItemPart NamePart NumberDescriptionQtyFRU 851 3C PROBE (JPN) 2286353 1 852 3.5C PROBE (JPN) 2348877 1 853 5C PROBE (JPN) 2294515 1 854M7CMIH PROBE (JPN)22945131 855E8C PROBE (JPN)22946401 8567L PROBE (JPN)22945201 857 10L PROBE (JPN) 2294522 1 858 M12LMIH PROBE (JPN) 2294510 1 859 3S PROBE (JPN) 2348878 1 86010S PROBE (JPN)23094781 861I12L PROBE (JPN)22705561 8628C PROBE23480931 863 3.5CS PROBE 2380854 1 864 6T TEE PROBE 2294534 1 865 M3S PROBE 2293726 1 8667S PROBE (JPN)23556981 867BE9C PROBE (JPN)23893811 868T739 PROBE (JPN)22592451 869 PPA ADAPTER 2331934-2 1 870 4D10L (JPN) 51216514D OPTION required. 1 871 4D3C_L (JPN) 51216524D OPTION required. 1 87212L PROBE (JPN)22953751 8734C PROBE (JPN)51319441
![](/img/blank.gif)
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 9-54Section 9-9 - Renewal Parts List For BT04 and BT06 9-9-17 LCD Option Figure 9-17 LCD Option 901 902 903 904 905 906 907 908 909 910 911 912