Panasonic Kx Taw848 PC Cprogramming Manual
Have a look at the manual Panasonic Kx Taw848 PC Cprogramming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2.7 [1] Configuration PC Programming Manual 81 Value Range 0 (no limit), 1, 2, 3 Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual References 1.3.1 Caller ID Caller ID—Caller ID (FSK) Carrier Detection Enables the PBX to detect the carrier when receiving Caller ID. To enable this setting, Caller ID— Caller ID Signalling on this screen should be set to FSK. Default Enable Value Range Disable, Enable Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual References 1.3.1 Caller ID Caller ID—Caller ID (FSK) END Detection Selects the method used to detect the end of Caller ID information. Default Length + Timer Value Range Length + Timer, Timer Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None
2.7 [1] Configuration 82 PC Programming Manual Feature Manual References 1.3.1 Caller ID Caller ID—Caller ID (FSK) Header Examination Enables the PBX to check the header of received Caller ID information. To enable this setting, Caller ID—Caller ID Signalling on this screen should be set to FSK. Default Enable Value Range Disable, Enable Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual References 1.3.1 Caller ID Caller ID—Caller ID (FSK) Detection Start Timer Specifies the length of time that the PBX waits before attempting to detect Caller ID information, after receiving a call. To enable this setting, Caller ID—Caller ID Signalling on this screen should be set to FSK. Default 80 ms Value Range None, 80 × n (n=1–15) ms Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual References 1.3.1 Caller ID Caller ID—Caller ID (FSK) Detection Timer Specifies the total time required by the PBX to detect Caller ID information. To enable this setting, Caller ID—Caller ID Signalling on this screen should be set to FSK.
2.7 [1] Configuration PC Programming Manual 83 Default 2000 ms Value Range 80 × n (n=13–50) ms Maintenance Console Location 2.7.7 [1-1] Slot—LCO Card Property Programming Manual References None Feature Manual References 1.3.1 Caller ID 2.7.8 [1-1] Slot—LCO Port Various settings can be programmed for each analog CO line port. To change the status of ports, click Command. Slot Indicates the slot position (reference only). Default Current slot number Value Range Slot number Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None Feature Manual References None Por t Indicates the por t number (reference only). Default Current port number
2.7 [1] Configuration 84 PC Programming Manual Value Range Port number Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None Feature Manual References None Connection Indicates the port status (reference only). This column offers two ways to open the screen to select the port command: Click the desired cell in the column. Select the desired cell in the column, and then click Command. Default Current status Value Range INS: The port is in service. OUS: The port is out of service. Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References 2.7.9 [1-1] Slot—LCO Port—Port Command Feature Manual References None Dialing Mode Selects the type of signal used to dial out to the analog CO line. Default DTMF Value Range DTMF, Pulse Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port
2.7 [1] Configuration PC Programming Manual 85 Programming Manual References None Feature Manual References 1.4.2 Dial Mode Selection CPC Signal Detection Time—Outgoing, Incoming Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming CO line calls before disconnecting the line. When None is selected here, the line will not be disconnected when a CPC signal is not detected. Default 400 ms Value Range None, 6.5 ms, 8 × n (n=1–112) ms Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None Feature Manual References 1.3.17 CPC (Calling Party Control) Signal Detection DTMF Width Selects the length of the DTMF tone sent to the analog CO line. Default 80 ms Value Range 80 ms, 160 ms Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None Feature Manual References None
2.7 [1] Configuration 86 PC Programming Manual Pulse Speed Selects the speed at which pulse dials are sent to the analog CO line. Default Low Value Range Low, High Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None Feature Manual References None Caller ID Detection Enables the PBX to detect a Caller ID signal from the analog CO line. Default Enable Value Range Disable, Enable Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References 2.7.7 [1-1] Slot—LCO Card Property Feature Manual References 1.3.1 Caller ID Pause Time Specifies the length of a pause. Default 1.5 s Value Range 1.5 s, 2.5 s, 3.5 s, 4.5 s
2.7 [1] Configuration PC Programming Manual 87 Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None Feature Manual References 1.8.5 Host PBX Access Code (Access Code to the Telephone Company from a Host PBX) 1.13.4 Pause Inser tion 1.16.2 Special Carrier Access Code Flash Time Specifies the length of a flash signal. Default 608 ms Value Range None, 16 × n (n=1–255) ms Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None Feature Manual References 1.5.1 EFA (External Feature Access) Disconnect Time Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the line. Default 1.5 s Value Range 0.5 s, 1.5 s, 2.0 s, 4.0 s, 12.0 s Maintenance Console Location 2.7.8 [1-1] Slot—LCO Port Programming Manual References None
2.7 [1] Configuration 88 PC Programming Manual Feature Manual References 1.6.2 Flash/Recall/Terminate 2.7.9 [1-1] Slot—LCO Port—Port Command Commands for the LCO ports can be programmed. INS Puts the port in service. Default Not applicable. Value Range Not applicable. Maintenance Console Location 2.7.9 [1-1] Slot—LCO Port—Port Command Programming Manual References 2.7.8 [1-1] Slot—LCO Port Feature Manual References None OUS Takes the port out of service. This enables a temporary non-use of the port, for example, for the purpose of repair. Default Not applicable. Value Range Not applicable. Maintenance Console Location 2.7.9 [1-1] Slot—LCO Port—Port Command Programming Manual References 2.7.8 [1-1] Slot—LCO Port Feature Manual References None
2.7 [1] Configuration PC Programming Manual 89 2.7.10 [1-1] Slot—DPH Card Property The status of the DPH ports can be viewed, and set to INS (in service) or OUS (out of service). Slot Indicates the slot position (reference only). Default Current slot number Value Range Slot number Maintenance Console Location 2.7.10 [1-1] Slot—DPH Card Property Programming Manual References None Feature Manual References None Por t Number Indicates the por t number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.7.10 [1-1] Slot—DPH Card Property Programming Manual References None Feature Manual References None Por t Status Indicates the por t status (reference only). This column offers two ways to open the screen to select the por t command: Click the desired cell in the column.
2.7 [1] Configuration 90 PC Programming Manual Select the desired cell in the column, and then click Command. Default Current status Value Range INS: The port is in service. OUS: The port is out of service. Fault: The port is not communicating with the network. Maintenance Console Location 2.7.10 [1-1] Slot—DPH Card Property Programming Manual References 2.7.11 [1-1] Slot—DPH Port Command Feature Manual References None For Output (EIO)—Device Type Selects the type of connected output device (for output ports only). Default Door Opener Value Range Relay, Ringer, Door Opener Maintenance Console Location 2.7.10 [1-1] Slot—DPH Card Property Programming Manual References 2.11.6 [5-4] External Relay Feature Manual References 1.4.9 Door Open 1.5.8 External Relay For Sensor (EIO)—Input Signal Decision Time Specifies the minimum duration of continuous input from the triggered sensor before the PBX recognizes the input and makes a sensor call. Default 1024 ms