    							2.7 [1] Configuration
    PC Programming Manual 81
    Value Range
    0 (no limit), 1, 2, 3
    Maintenance Console Location
    2.7.7 [1-1] Slot—LCO Card Property
    Programming Manual References
    None
    Feature Manual References
    1.3.1 Caller ID
    Caller ID—Caller ID (FSK) Carrier Detection
    Enables the PBX to detect the carrier when receiving Caller ID. To enable this setting, Caller ID—
    Caller ID Signalling on this screen should be set to FSK.
    Default
    Enable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.7.7 [1-1] Slot—LCO Card Property
    Programming Manual References
    None
    Feature Manual References
    1.3.1 Caller ID
    Caller ID—Caller ID (FSK) END Detection
    Selects the method used to detect the end of Caller ID information.
    Default
    Length + Timer
    Value Range
    Length + Timer, Timer
    Maintenance Console Location
    2.7.7 [1-1] Slot—LCO Card Property
    Programming Manual References
    None 
    						
    							2.7 [1] Configuration
    82 PC Programming Manual
    Feature Manual References
    1.3.1 Caller ID
    Caller ID—Caller ID (FSK) Header Examination
    Enables the PBX to check the header of received Caller ID information. To enable this setting, Caller 
    ID—Caller ID Signalling on this screen should be set to FSK.
    Default
    Enable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.7.7 [1-1] Slot—LCO Card Property
    Programming Manual References
    None
    Feature Manual References
    1.3.1 Caller ID
    Caller ID—Caller ID (FSK) Detection Start Timer
    Specifies the length of time that the PBX waits before attempting to detect Caller ID information, after 
    receiving a call. To enable this setting, 
    Caller ID—Caller ID Signalling on this screen should be set 
    to FSK.
    Default
    80 ms
    Value Range
    None, 80 × n (n=1–15) ms
    Maintenance Console Location
    2.7.7 [1-1] Slot—LCO Card Property
    Programming Manual References
    None
    Feature Manual References
    1.3.1 Caller ID
    Caller ID—Caller ID (FSK) Detection Timer
    Specifies the total time required by the PBX to detect Caller ID information. To enable this setting, 
    Caller ID—Caller ID Signalling on this screen should be set to FSK. 
    						
    							2.7 [1] Configuration
    PC Programming Manual 83
    Default
    2000 ms
    Value Range
    80 × n (n=13–50) ms
    Maintenance Console Location
    2.7.7 [1-1] Slot—LCO Card Property
    Programming Manual References
    None
    Feature Manual References
    1.3.1 Caller ID
    2.7.8 [1-1] Slot—LCO Port
    Various settings can be programmed for each analog CO line port. 
    To change the status of ports, click Command.
    Slot
    Indicates the slot position (reference only).
    Default
    Current slot number
    Value Range
    Slot number
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the por t number (reference only).
    Default
    Current port number 
    						
    							2.7 [1] Configuration
    84 PC Programming Manual
    Value Range
    Port number
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None
    Feature Manual References
    None
    Connection
    Indicates the port status (reference only). 
    This column offers two ways to open the screen to select the port command:
     Click the desired cell in the column.
     Select the desired cell in the column, and then click Command.
    Default
    Current status
    Value Range
    INS: The port is in service.
    OUS: The port is out of service.
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    2.7.9 [1-1] Slot—LCO Port—Port Command
    Feature Manual References
    None
    Dialing Mode
    Selects the type of signal used to dial out to the analog CO line.
    Default
    DTMF
    Value Range
    DTMF, Pulse
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port 
    						
    							2.7 [1] Configuration
    PC Programming Manual 85
    Programming Manual References
    None
    Feature Manual References
    1.4.2 Dial Mode Selection
    CPC Signal Detection Time—Outgoing, Incoming
    Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming CO 
    line calls before disconnecting the line. When None is selected here, the line will not be disconnected 
    when a CPC signal is not detected.
    Default
    400 ms
    Value Range
    None, 6.5 ms, 8 × n (n=1–112) ms
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None
    Feature Manual References
    1.3.17 CPC (Calling Party Control) Signal Detection
    DTMF Width
    Selects the length of the DTMF tone sent to the analog CO line.
    Default
    80 ms
    Value Range
    80 ms, 160 ms
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None
    Feature Manual References
    None 
    						
    							2.7 [1] Configuration
    86 PC Programming Manual
    Pulse Speed
    Selects the speed at which pulse dials are sent to the analog CO line.
    Default
    Low
    Value Range
    Low, High
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None
    Feature Manual References
    None
    Caller ID Detection
    Enables the PBX to detect a Caller ID signal from the analog CO line.
    Default
    Enable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    2.7.7 [1-1] Slot—LCO Card Property
    Feature Manual References
    1.3.1 Caller ID
    Pause Time
    Specifies the length of a pause.
    Default
    1.5 s
    Value Range
    1.5 s, 2.5 s, 3.5 s, 4.5 s 
    						
    							2.7 [1] Configuration
    PC Programming Manual 87
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None
    Feature Manual References
    1.8.5 Host PBX Access Code (Access Code to the Telephone Company from a Host PBX)
    1.13.4 Pause Inser tion
    1.16.2 Special Carrier Access Code
    Flash Time
    Specifies the length of a flash signal.
    Default
    608 ms
    Value Range
    None, 16 × n (n=1–255) ms
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None
    Feature Manual References
    1.5.1 EFA (External Feature Access)
    Disconnect Time
    Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the 
    line.
    Default
    1.5 s
    Value Range
    0.5 s, 1.5 s, 2.0 s, 4.0 s, 12.0 s
    Maintenance Console Location
    2.7.8 [1-1] Slot—LCO Port
    Programming Manual References
    None 
    						
    							2.7 [1] Configuration
    88 PC Programming Manual
    Feature Manual References
    1.6.2 Flash/Recall/Terminate
    2.7.9 [1-1] Slot—LCO Port—Port Command
    Commands for the LCO ports can be programmed.
    INS
    Puts the port in service.
    Default
    Not applicable.
    Value Range
    Not applicable.
    Maintenance Console Location
    2.7.9 [1-1] Slot—LCO Port—Port Command
    Programming Manual References
    2.7.8 [1-1] Slot—LCO Port
    Feature Manual References
    None
    OUS
    Takes the port out of service. This enables a temporary non-use of the port, for example, for the 
    purpose of repair.
    Default
    Not applicable.
    Value Range
    Not applicable.
    Maintenance Console Location
    2.7.9 [1-1] Slot—LCO Port—Port Command
    Programming Manual References
    2.7.8 [1-1] Slot—LCO Port
    Feature Manual References
    None 
    						
    							2.7 [1] Configuration
    PC Programming Manual 89
    2.7.10 [1-1] Slot—DPH Card Property
    The status of the DPH ports can be viewed, and set to INS (in service) or OUS (out of service).
    Slot
    Indicates the slot position (reference only).
    Default
    Current slot number
    Value Range
    Slot number
    Maintenance Console Location
    2.7.10 [1-1] Slot—DPH Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    Por t Number
    Indicates the por t number (reference only).
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.7.10 [1-1] Slot—DPH Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    Por t Status
    Indicates the por t status (reference only). 
    This column offers two ways to open the screen to select the por t command:
     Click the desired cell in the column. 
    						
    							2.7 [1] Configuration
    90 PC Programming Manual
     Select the desired cell in the column, and then click Command.
    Default
    Current status
    Value Range
    INS: The port is in service.
    OUS: The port is out of service.
    Fault: The port is not communicating with the network.
    Maintenance Console Location
    2.7.10 [1-1] Slot—DPH Card Property
    Programming Manual References
    2.7.11 [1-1] Slot—DPH Port Command
    Feature Manual References
    None
    For Output (EIO)—Device Type
    Selects the type of connected output device (for output ports only).
    Default
    Door Opener
    Value Range
    Relay, Ringer, Door Opener
    Maintenance Console Location
    2.7.10 [1-1] Slot—DPH Card Property
    Programming Manual References
    2.11.6 [5-4] External Relay
    Feature Manual References
    1.4.9 Door Open
    1.5.8 External Relay
    For Sensor (EIO)—Input Signal Decision Time
    Specifies the minimum duration of continuous input from the triggered sensor before the PBX 
    recognizes the input and makes a sensor call.