2.10 [4] Extension PC Programming Manual 351 Value Range All (Day/Night/Lunch/Break), Day/Night/Break, Day/Night/Lunch, Day/Night Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Parameter Selection (for TRS Level Change) Specifies the TRS level to be used temporarily on a certain extension. Default 1 Value Range 1–7 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—TRS 2.13 [7] TRS Feature Manual References 1.4.4 Dial Tone Transfer 1.17.5 TRS (Toll Restriction) Parameter Selection (for Time Service - Automatic/Manual) Specifies the Time Table to be used when the Time Service Switching Mode is set to automatic. Default 1 Value Range 1–8 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button
2.10 [4] Extension 352 PC Programming Manual Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Ext. No. / Floating Ext No. (for DSS) Specifies the number of an extension to be accessed. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References None Ext. No. / Floating Ext No. (for ICD Group) Specifies the floating extension number of an incoming call distribution group to be accessed. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.1 ICD GROUP FEATURES
2.10 [4] Extension PC Programming Manual 353 Ext. No. / Floating Ext No. (for Message Waiting) Specifies the number of an extension or floating extension number of an incoming call distribution group for which messages are checked. If this cell is left empty, the paired extension will check its own messages only. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.11.3 Message Waiting Ext. No. / Floating Ext No. (for Group Fwd (Both)) Specifies the floating extension number of an incoming call distribution group for which both intercom and CO line calls are forwarded. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext No. (for Group Fwd (External)) Specifies the floating extension number of an incoming call distribution group for which CO line calls are forwarded. Default Not stored.
2.10 [4] Extension 354 PC Programming Manual Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext No. (for Group Fwd (Internal)) Specifies the floating extension number of an incoming call distribution group for which intercom calls are forwarded. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext No. (for Call Log) Specifies the paired extensions number or the floating extension number of an incoming call distribution group for which call log information is displayed. If the cell is left empty, the paired extension will display its own call log information. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button
2.10 [4] Extension PC Programming Manual 355 Programming Manual References None Feature Manual References 1.3.3 Call Log, Incoming Ext. No. / Floating Ext No. (for Log-in/Log-out) Specifies the floating extension number of an incoming call distribution group to log-in to or log-out from. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Ext. No. / Floating Ext No. (for Hurry-up) Specifies the floating extension number of the incoming call distribution group whose longest waiting call will be redirected (Manual Queue Redirection). Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Overflow No Answer Feature Manual References 1.9.5 ICD Group Features—Queuing
2.10 [4] Extension 356 PC Programming Manual Ext. No. / Floating Ext No. (for Two-way Record) Specifies the floating extension number of the VM (DPT) group containing the paired extensions mailbox. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext. No. / Floating Ext No. (for Two-way Transfer) Specifies the floating extension number of the VM (DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings 2.9.18 [3-8-2] VM(DTMF) Group—Group Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext. No. / Floating Ext No. (for Voice Mail Transfer) Specifies the floating extension number of the VM (DTMF/DPT) group containing the desired mailbox. Default Not stored.
2.10 [4] Extension PC Programming Manual 357 Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings 2.9.18 [3-8-2] VM(DTMF) Group—Group Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration 1.19.5 Voice Mail DTMF Integration Dial (for One-touch) Specifies the number to be dialed. The PBX can have a maximum of 2000 One-touch Dialing buttons for extensions and DSS Consoles. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.12.2 One-touch Dialing Optional Parameter (Ringing Tone Type Number) (for Time Service) Specifies the Time Table to be used for changing time modes in the Automatic Switching mode. Default 1 Value Range 1–8 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button
2.10 [4] Extension 358 PC Programming Manual Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Optional Parameter (Ringing Tone Type Number) (for Call Park) Specifies the number of the parking zone a call is to be parked in when a Call Park button with Parameter Selection (for Call Park) on this screen set to Specific is pressed. Default 0 Value Range 0–99 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Ext. No. of Mailbox (for Two-way Transfer) Specifies the number of the extension whose mailbox will be used to record conversations using One- touch Two-way Transfer. (For example, a secretary can record a conversation into the mailbox of a boss.) If the cell is left empty, the extension user must specify the number of an extension each time. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration
2.10 [4] Extension PC Programming Manual 359 2.10.14 [4-3] DSS Console—Flexible Button—Flexible button Data Copy The flexible DSS button settings of a DSS Console can be copied to different DSS Consoles. Select the DSS Console that has the setting to copy to other DSS Consoles from the DSS Console No./ Pair Extension list, then click Copy To. Destination DSS Console Select the number of the DSS Console and paired extension. Multiple DSS Consoles can be selected. To select all DSS Consoles at once, click Select All. Maintenance Console Location 2.10.14 [4-3] DSS Console—Flexible Button—Flexible button Data Copy Programming Manual References 2.10.13 [4-3] DSS Console—Flexible Button Feature Manual References None
2.11 [5] Optional Device 360 PC Programming Manual 2.11 [5] Optional Device 2.11.1 [5-1] Doorphone The settings to establish doorphone calls can be programmed. To assign destinations for doorphone calls easily, click Extension Number of Destination Setting (see 2.1.6 Extension Number Setting). Physical—Slot Indicates the slot to which the doorphone is connected (reference only). Default Current slot number Value Range Slot number Maintenance Console Location 2.11.1 [5-1] Doorphone Programming Manual References None Feature Manual References 1.4.10 Doorphone Call Physical—Port Indicates the port number to which the doorphone is connected (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.11.1 [5-1] Doorphone Programming Manual References None Feature Manual References 1.4.10 Doorphone Call