2.10 [4] Extension PC Programming Manual 291 Maintenance Console Location 2.10.2 [4-1-2] Wired Extension—FWD/DND Programming Manual References None Feature Manual References 1.6.6 FWD (Call Forwarding) FWD No Answer Timer Specifies the length of time that an incoming call rings at the extension before the call is forwarded. Default 15 s Value Range 0–120 s Maintenance Console Location 2.10.2 [4-1-2] Wired Extension—FWD/DND Programming Manual References None Feature Manual References 1.6.6 FWD (Call Forwarding) 2.10.3 [4-1-3] Wired Extension—Speed Dial Personal Speed Dialing allows extension users to dial frequently dialed numbers using two-digit speed dialing numbers (00–09). A maximum of 10 Personal Speed Dialing numbers can be programmed for each extension. Select the desired extension from the Extension Number / Name list. Speed Dialing Name Specifies the name of the Personal Speed Dialing number to call using the Personal Speed Dialing Directory shown on the extensions display. Default Not stored. Value Range Max. 20 characters
2.10 [4] Extension 292 PC Programming Manual Maintenance Console Location 2.10.3 [4-1-3] Wired Extension—Speed Dial Programming Manual References None Feature Manual References 1.16.3 Speed Dialing, Personal Dialing Number Specifies the number to be dialed by the Personal Speed Dialing number. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.3 [4-1-3] Wired Extension—Speed Dial Programming Manual References None Feature Manual References 1.16.3 Speed Dialing, Personal 2.10.4 [4-1-4] Wired Extension—Flexible Button Each flexible CO button can be customized to allow one-touch access to a certain feature. A maximum of 12 flexible CO buttons can be customized for each extension. Select the desired extension from the Extension Number / Name list. To copy the flexible CO button settings of an extension to another extension, click Copy To. For more information on flexible buttons, see 1.6.3 Flexible Buttons in the Feature Manual. Ty p e Specifies the feature to be assigned to the flexible CO button. Default Key Location 1–8: Single CO Key Location 9–12: Not Stored Value Range Not Stored, Loop CO, Single CO, Group CO, DSS, One-touch, ICD Group, Message Waiting, FWD/ DND (Both), FWD/DND (External), FWD/DND (Internal), Group Fwd (Both), Group Fwd (External), Group Fwd (Internal), Account, Conference, Terminate, EFA, Call Park, Call Log, Log-in/Log-out,
2.10 [4] Extension PC Programming Manual 293 Hurry-up, Wrap-up, System Alarm, Time Service, Answer, Release, TRS Level Change, Time Service - Automatic/Manual, Two-way Record, Two-way Transfer, LCS, Voice Mail Transfer Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.10.5 [4-1-4] Wired Extension—Flexible Button—Flexible Button Data Copy Feature Manual References 1.6.3 Flexible Buttons Parameter Selection (for Single CO) Specifies the CO line to be accessed. Default 1 Value Range 1–8 Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.10.5 [4-1-4] Wired Extension—Flexible Button—Flexible Button Data Copy Feature Manual References 1.3.11 CO Line Access Parameter Selection (for Group CO) Specifies the trunk group to be accessed. Default 1 Value Range 1–64 Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.1 [3-1-1] Trunk Group—TRG Settings
2.10 [4] Extension 294 PC Programming Manual Feature Manual References 1.3.11 CO Line Access Parameter Selection (for Call Park) Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone. Default Automatic Value Range Automatic, Specific Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Parameter Selection (for Log-in/Log-out) Specifies which incoming call distribution groups that the extension belongs to are logged in to or logged out from. Default None Value Range None: The incoming call distribution group is selected manually. All: All incoming call distribution groups that the extension belongs to. Incoming Group: A pre-specified incoming call distribution group Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References None Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Parameter Selection (for Time Service) Selects which time modes are switched manually.
2.10 [4] Extension PC Programming Manual 295 Default All Value Range All (Day/Night/Lunch/Break), Day/Night/Break, Day/Night/Lunch, Day/Night Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Parameter Selection (for TRS Level Change) Specifies the TRS level to be used temporarily on a certain extension. Default 1 Value Range 1–7 Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—TRS 2.13 [7] TRS Feature Manual References 1.4.4 Dial Tone Transfer 1.17.5 TRS (Toll Restriction) Parameter Selection (for Time Service - Automatic/Manual) Specifies the Time Table to be used when the Time Service Switching Mode is set to automatic. Default 1 Value Range 1–8
2.10 [4] Extension 296 PC Programming Manual Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Ext No. / Floating Ext. No. (for DSS) Specifies the number of an extension to be accessed. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References None Feature Manual References None Ext No. / Floating Ext. No. (for ICD Group) Specifies the floating extension number of an incoming call distribution group to be accessed. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.1 ICD GROUP FEATURES
2.10 [4] Extension PC Programming Manual 297 Ext No. / Floating Ext. No. (for Message Waiting) Specifies the number of an extension or floating extension number of an incoming call distribution group for which messages are checked. If this cell is left empty, the extension will check its own messages only. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References None Feature Manual References 1.11.3 Message Waiting Ext No. / Floating Ext. No. (for Group FWD (Both)) Specifies the floating extension number of an incoming call distribution group for which both intercom and CO line calls are forwarded. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext No. / Floating Ext. No. (for Group FWD (External)) Specifies the floating extension number of an incoming call distribution group for which CO line calls are forwarded. Default Not stored.
2.10 [4] Extension 298 PC Programming Manual Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext No. / Floating Ext. No. (for Group FWD (Internal)) Specifies the floating extension number of an incoming call distribution group for which intercom calls are forwarded. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext No. / Floating Ext. No. (for Call Log) Specifies the extensions own number or the floating extension number of an incoming call distribution group for which call log information is displayed. If the cell is left empty, the extension will display its own call log information. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button
2.10 [4] Extension PC Programming Manual 299 Programming Manual References None Feature Manual References 1.3.3 Call Log, Incoming Ext No. / Floating Ext. No. (for Log-in/Log-out) Specifies the floating extension number of an incoming call distribution group to log-in to or log-out from. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Ext No. / Floating Ext. No. (for Hurry-up) Specifies the floating extension number of the incoming call distribution group whose longest waiting call will be redirected (Manual Queue Redirection). Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Overflow No Answer Feature Manual References 1.9.5 ICD Group Features—Queuing
2.10 [4] Extension 300 PC Programming Manual Ext No. / Floating Ext. No. (for Two-way Record) Specifies the floating extension number of the VM (DPT) group containing the extensions mailbox. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext No. / Floating Ext. No. (for Two-way Transfer) Specifies the floating extension number of the VM (DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.4 [4-1-4] Wired Extension—Flexible Button Programming Manual References 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext No. / Floating Ext. No. (for Voice Mail Transfer) Specifies the floating extension number of the VM (DTMF/DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 4 digits (consisting of 0–9)