2.8 [2] System PC Programming Manual 121 Value Range 1–600 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.10.7 [4-1-6] Wired Extension—Simplified Voice Message 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Feature Manual References 1.16.5 SVM (Simplified Voice Message) SVM—Dial Tone Continuous Time Specifies the length of time that dial tone 3 is heard after all messages stored by the SVM feature for an extension are finished playing. Default 5 s Value Range 1–60 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.10.7 [4-1-6] Wired Extension—Simplified Voice Message 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Feature Manual References 1.16.5 SVM (Simplified Voice Message) 2.8.5 [2-4] Week Table A specific time mode (day, night, lunch, or break) can be selected for operation depending on the time of day. The time mode can be switched either automatically or manually. Select the desired switching mode from the Time Service Switching Mode option. Time Table numbers correspond to tenant numbers (for example, Tenant 1 uses Time Table 1). Select the desired Time Table from the Time Table No. list. When in Automatic Switching mode, the time modes of the tenant are switched as programmed in the corresponding Time Table. Manual switching is possible only from an authorized extension (determined by COS). To adjust the currently displayed Time Table, click and drag the divisions between two time periods.
2.8 [2] System 122 PC Programming Manual To program the time blocks of the currently displayed Time Table, including adding or deleting time blocks, click Time Setting. 2.8.6 [2-4] Week Table—Time Setting The start times of 4 different time blocks can be programmed for each day of the week, for the selected Time Table, as well as the start and end times of up to 3 break periods. 1. Day/Lunch/Night—Day1 Start, Lunch Start, Day2 Start, Night Start— Setting Enables the setting of the start time for each time block. Default Day 1 Start, Night Start: Enable Lunch Start, Day 2 Start: Disable Value Range Disable, Enable Maintenance Console Location 2.8.6 [2-4] Week Table—Time Setting Programming Manual References None Feature Manual References 1.17.2 Tenant Service 1.17.4 Time Service 1. Day/Lunch/Night—Day1 Start, Lunch Start, Day2 Start, Night Start—Hour, Minute Specifies the start time for each time block. Times can only be set when 1. Day/Lunch/Night—Day1 Start, Lunch Start, Day2 Start, Night Start—Setting is set to Enable. Default Day1: 9:00 Lunch: 12:00 Day2: 13:00 Night: 17:00 Value Range 00:00–23:59 Maintenance Console Location 2.8.6 [2-4] Week Table—Time Setting
2.8 [2] System PC Programming Manual 123 Programming Manual References None Feature Manual References 1.17.2 Tenant Service 1.17.4 Time Service 2. Break—Break 1–3 Start—Setting Enables the setting of the start time for each break period. Default Disable Value Range Disable, Enable Maintenance Console Location 2.8.6 [2-4] Week Table—Time Setting Programming Manual References None Feature Manual References 1.17.2 Tenant Service 1.17.4 Time Service 2. Break—Break 1–3 Start—Hour, Minute Specifies the start time for each break period. Times can only be set when 2. Break—Break 1–3 Start—Setting is set to Enable. Default 00:00 Value Range 00:00–23:59 Maintenance Console Location 2.8.6 [2-4] Week Table—Time Setting Programming Manual References None Feature Manual References 1.17.2 Tenant Service 1.17.4 Time Service
2.8 [2] System 124 PC Programming Manual 2. Break—Break 1–3 End—Hour, Minute Specifies the end time for each break period. Times can only be set when 2. Break—Break 1–3 Start—Setting is set to Enable. Default 00:00 Value Range 00:00–23:59 Maintenance Console Location 2.8.6 [2-4] Week Table—Time Setting Programming Manual References None Feature Manual References 1.17.2 Tenant Service 1.17.4 Time Service 2.8.7 [2-5] Holiday Table A specific time mode (day, night, lunch, or break) can be selected for operation during holidays. Select the desired time mode from the Holiday Mode list. The start and end dates of a maximum of 24 different holidays can be programmed. Holiday Table—Setting Enables the setting of the holiday. Default Disable Value Range Disable, Enable Maintenance Console Location 2.8.7 [2-5] Holiday Table Programming Manual References None Feature Manual References 1.17.4 Time Service
2.8 [2] System PC Programming Manual 125 Holiday Table—Start Date—Month Specifies the month of the holiday start date. Default 1 Value Range 1–12 Maintenance Console Location 2.8.7 [2-5] Holiday Table Programming Manual References None Feature Manual References 1.17.4 Time Service Holiday Table—Start Date—Day Specifies the day of the holiday start date. Default 1 Value Range 1–31 Maintenance Console Location 2.8.7 [2-5] Holiday Table Programming Manual References None Feature Manual References 1.17.4 Time Service Holiday Table—End Date—Month Specifies the month of the holiday end date. Default 1 Value Range 1–12
2.8 [2] System 126 PC Programming Manual Maintenance Console Location 2.8.7 [2-5] Holiday Table Programming Manual References None Feature Manual References 1.17.4 Time Service Holiday Table—End Date—Day Specifies the day of the holiday end date. Default 1 Value Range 1–31 Maintenance Console Location 2.8.7 [2-5] Holiday Table Programming Manual References None Feature Manual References 1.17.4 Time Service 2.8.8 [2-6-1] Numbering Plan—Main Details of the extension numbering schemes and feature access numbers can be programmed here. For more information on flexible numbering, see 1.6.4 Flexible Numbering/Fixed Numbering in the Feature Manual. Extension The leading numbers and the number of additional digits of the extension numbers for a maximum of 64 different extension numbering schemes can be programmed. Leading Number Specifies the leading number of extension numbers and floating extension numbers. Default Extension Numbering Scheme 01: 1 Extension Numbering Scheme 02: 2 Extension Numbering Scheme 03: 3 Extension Numbering Scheme 04: 4
2.8 [2] System PC Programming Manual 127 Extension Numbering Scheme 21: 5 Extension Numbering Scheme 22: 6 Extension Numbering Scheme 05–20, 23–64: Not stored. Value Range Max. 2 digits (consisting of 0–9) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings 2.9.15 [3-7-2] VM(DPT) Group—Unit Settings 2.9.18 [3-8-2] VM(DTMF) Group—Group Settings 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings 2.11.4 [5-3-2] Voice Message—DISA Message 2.16.1 [10-1] Main Feature Manual References 1.6.4 Flexible Numbering/Fixed Numbering No. of Additional Digits Specifies the number of additional digits following the leading number. Default XX Value Range None: 0 digit X: 1 digit XX: 2 digits Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.6.4 Flexible Numbering/Fixed Numbering Features Feature numbers to access various PBX features can be programmed. The following features are available while hearing a dial tone.
2.8 [2] System 128 PC Programming Manual Operator Call Specifies the feature number used to call the operator. Default 0 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.8.3 [2-2] Operator & BGM 2.12.6 [6-6] Tenant Feature Manual References 1.12.3 Operator Features Idle Line Access (Local Access) Specifies the feature number used to make a CO line call by Idle Line Access (selects an idle CO line automatically). Default 9 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.2 [3-1-2] Trunk Group—Local Access Priority Feature Manual References 1.3.11 CO Line Access Trunk Group Access Specifies the feature number used to make a CO line call using an idle CO line from a certain trunk group. Default 8
2.8 [2] System PC Programming Manual 129 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.11 CO Line Access Redial Specifies the feature number used to redial the last number dialed. Default # Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.15.1 Redial, Last Number System Speed Dialing / Personal Speed Dialing Specifies the feature number used to make a call using a System/Personal Speed Dialing number. Default ** Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.10.3 [4-1-3] Wired Extension—Speed Dial 2.12.1 [6-1] System Speed Dial
2.8 [2] System 130 PC Programming Manual Feature Manual References 1.16.3 Speed Dialing, Personal 1.16.4 Speed Dialing, System Personal Speed Dialing - Programming Specifies the feature number used to program Personal Speed Dialing numbers at an extension. Default *30 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.16.3 Speed Dialing, Personal Doorphone Call Specifies the feature number used to make a call to a doorphone. Default *31 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.11.1 [5-1] Doorphone Feature Manual References 1.4.10 Doorphone Call Group Paging Specifies the feature number used to page a certain paging group. Default *33