    							2.10 [4] Extension
    PC Programming Manual 341
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext No. / Floating Ext. No. (for Group Fwd (External))
    Specifies the floating extension number of an incoming call distribution group for which CO line calls 
    are forwarded.
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext No. / Floating Ext. No. (for Group Fwd (Internal))
    Specifies the floating extension number of an incoming call distribution group for which intercom calls 
    are forwarded.
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding) 
    						
    							2.10 [4] Extension
    342 PC Programming Manual
    Ext No. / Floating Ext. No. (for Log-in/Log-out)
    Specifies the floating extension number of an incoming call distribution group to log-in to or log-out 
    from.
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out
    Ext No. / Floating Ext. No. (for Hurry-up)
    Specifies the floating extension number of the incoming call distribution group whose longest waiting 
    call will be redirected (Manual Queue Redirection).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Overflow No Answer
    Feature Manual References
    1.9.5 ICD Group Features—Queuing
    Ext No. / Floating Ext. No. (for Two-way Record)
    Specifies the floating extension number of the VM (DPT) group containing the PSs mailbox.
    Default
    Not stored. 
    						
    							2.10 [4] Extension
    PC Programming Manual 343
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.15 [3-7-2] VM(DPT) Group—Unit Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    Ext No. / Floating Ext. No. (for Two-way Transfer)
    Specifies the floating extension number of the VM (DPT) group containing the desired mailbox.
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.15 [3-7-2] VM(DPT) Group—Unit Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    Ext No. / Floating Ext. No. (for Voice Mail Transfer)
    Specifies the floating extension number of the VM (DTMF/DPT) group containing the desired mailbox.
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.15 [3-7-2] VM(DPT) Group—Unit Settings
    2.9.18 [3-8-2] VM(DTMF) Group—Group Settings 
    						
    							2.10 [4] Extension
    344 PC Programming Manual
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    1.19.5 Voice Mail DTMF Integration
    Dial (for One-touch)
    Specifies the number to be dialed. The PBX can have a maximum of 500 One-touch Dialing buttons 
    for PSs.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.12.2 One-touch Dialing
    Optional Parameter (or Ringing Tone Type Number) (for Time Service)
    Specifies the Time Table to be used for changing time modes in the Automatic Switching mode.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.17.4 Time Service
    Optional Parameter (or Ringing Tone Type Number) (for Call Park)
    Specifies the number of the parking zone a call is to be parked in when a Call Park button with 
    Parameter Selection (for Call Park) on this screen set to Specific is pressed. 
    						
    							2.10 [4] Extension
    PC Programming Manual 345
    Default
    0
    Value Range
    0–99
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.3.5 Call Park
    Ext. No. of Mailbox (for Two-way Transfer)
    Specifies the number of the extension whose mailbox will be used to record conversations using One-
    touch Two-way Transfer. (For example, a secretary can record a conversation into the mailbox of a 
    boss.) If the cell is left empty, the extension user must specify the number of an extension each time.
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    2.10.11 [4-2-3] Portable Station—Flexible Button—Flexible Button 
    Data Copy
    The flexible CO button settings of a PS can be copied to different PSs.
    Destination Extension Line
    Select the number and name of the PS that will receive the copied settings. Multiple PSs can be 
    selected. To select all PSs at once, click Select All. 
    						
    							2.10 [4] Extension
    346 PC Programming Manual
    Maintenance Console Location
    2.10.11 [4-2-3] Portable Station—Flexible Button—Flexible Button Data Copy
    Programming Manual References
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Feature Manual References
    None
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    When an SVM card is installed in the PBX, Simplified Voice Message features can be provided for 
    each PS. 
    This screen allows you to specify which card each extension belongs to, and the maximum number 
    of messages that can be stored for each extension. 
    For more information on Simplified Voice Message, see 1.16.5 SVM (Simplified Voice Message) in 
    the Feature Manual.
    Extension Number
    Indicates the extension number (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension No.
    Feature Manual References
    None
    Extension Name
    Indicates the name of the extension (reference only).
    Default
    Not stored.
    Value Range
    Max. 20 characters 
    						
    							2.10 [4] Extension
    PC Programming Manual 347
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    2.10.8 [4-2-1] Portable Station—Extension Settings2.7.12 [1-2] Portable Station—Extension Name
    Feature Manual References
    None
    Simplified Voice Message
    Selects which SVM card to use to store and play back greetings and messages for the extension. 
    Each extension must be assigned to a specific SVM card, and can only use the assigned card. If two 
    SVM cards are installed in the PBX, you should assign a number of extensions to each card, to 
    ensure that the necessary resources, such as message recording space, are available for each 
    extension.
    Default
    Card1
    Value Range
    None, Card1, Card2
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    None
    Feature Manual References
    1.16.5 SVM (Simplified Voice Message)
    Maximum of SVM Log
    Specifies the maximum number of voice messages (not including greeting messages) that can be 
    stored for the extension.
    Default
    10
    Value Range
    1–100
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    348 PC Programming Manual
    Feature Manual References
    1.16.5 SVM (Simplified Voice Message)
    2.10.13 [4-3] DSS Console—Flexible Button
    A DSS Console can be used in conjunction with a PT. A maximum of 4 DSS Consoles can be 
    programmed. The 
    DPT Type—Type (for Hybrid port) of the extension port that DSS Console is 
    connected must be set to DSS in 2.7.4 [1-1] Slot—Extension Port.
    Each flexible DSS button can be customized to access a certain feature. A maximum of 66 flexible 
    DSS buttons can be customized for each DSS Console. Select the desired DSS Console from the 
    DSS Console No. list. 
     
    To copy DSS Console setting values from one location to another, click the Copy To button. 
    For more information on flexible buttons, see 1.6.3 Flexible Buttons in the Feature Manual.
    Pair Extension
    Specifies the extension number of the PT to be used in pair with the DSS Console.
    Default
    None
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.5.7 Extension Port Configuration
    Ty p e
    Specifies the feature to be assigned to the flexible DSS button.
    Default
    Not Stored
    Value Range
    Not Stored, Loop CO, Single CO, Group CO, DSS, One-touch, ICD Group, Message Waiting, FWD/
    DND (Both), FWD/DND (External), FWD/DND (Internal), Group Fwd (Both), Group Fwd (External), 
    Group Fwd (Internal), Account, Conference, Terminate, EFA, Call Park, Call Log, Log-in/Log-out, 
    Hurry-up, Wrap-up, System Alarm, Time Service, Answer, Release, TRS Level Change, Time 
    Service - Automatic/Manual, Two-way Record, Two-way Transfer, LCS, Voice Mail Transfer 
    						
    							2.10 [4] Extension
    PC Programming Manual 349
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.10.14 [4-3] DSS Console—Flexible Button—Flexible button Data Copy
    Feature Manual References
    1.6.3 Flexible Buttons
    Parameter Selection (for Single CO)
    Specifies the CO line to be accessed.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.3.11 CO Line Access
    Parameter Selection (for Group CO)
    Specifies the trunk group to be accessed.
    Default
    1
    Value Range
    1–64
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.1 [3-1-1] Trunk Group—TRG Settings
    Feature Manual References
    1.3.11 CO Line Access 
    						
    							2.10 [4] Extension
    350 PC Programming Manual
    Parameter Selection (for Call Park)
    Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone.
    Default
    Automatic
    Value Range
    Automatic, Specific
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.3.5 Call Park
    Parameter Selection (for Log-in/Log-out)
    Specifies which incoming call distribution groups that the paired extension belongs to are logged in 
    to or logged out from.
    Default
    None
    Value Range
    None: The incoming call distribution group is selected manually. 
    All: All incoming call distribution groups that the paired extension belongs to. 
    Incoming Group: A pre-specified incoming call distribution group
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out
    Parameter Selection (for Time Service)
    Selects which time modes are switched manually.
    Default
    All 
    						