2.16 [10] Maintenance PC Programming Manual 431 Remote—Password Lock Counter for Remote Programming Specifies the number of successive incorrect password entries allowed before remote access is locked. Default None Value Range None, 1–15 Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming Remote—Remote Maintenance Dial Number (Own Telephone number for reference) Specifies the telephone number of the PBX used to access the PBX from a remote location for maintenance purposes. This number can be specified by Quick Setup. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.14.2 Quick Setup Password Passwords authorize the user to program the extension and the PBX by a PT or a personal computer.
2.16 [10] Maintenance 432 PC Programming Manual System Password - PT Programming—Prog ** : User Level Specifies the user level system password to authorize the PT user to access only the permitted system programming. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.15 PT Programming System Password - PT Programming—Prog *# : Administrator Level Specifies the administrator level system password to authorize the PT user to access all system programming. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.15 PT Programming Manager Password - PT Programming—Prog *1 Specifies the manager password to authorize the PT user to access manager programming. Default 1234
2.16 [10] Maintenance PC Programming Manual 433 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.11.1 Manager Features System Password - PC Programming—User Level Specifies the system password used to access KX-TAW848 Maintenance Console at User Level. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming System Password - PC Programming—Administrator Level Specifies the system password used to access KX-TAW848 Maintenance Console at Administrator Level. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None
2.16 [10] Maintenance 434 PC Programming Manual Feature Manual References 1.13.5 PC Programming System Password - PC Programming—Installer Level Specifies the system password used to access KX-TAW848 Maintenance Console at Installer Level. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming 2.16.2 [10-2] PT Programming Access The programming items accessible at User and Administrator level can be specified. 100 programming item numbers are displayed at a time. To display other sets of numbers, click the applicable tab. Program Number Indicates the programming item number (reference only). Default Current programming item number Value Range 000–999 Maintenance Console Location 2.16.2 [10-2] PT Programming Access Programming Manual References None Feature Manual References 1.13.15 PT Programming
2.16 [10] Maintenance PC Programming Manual 435 PROG** Selects whether User Level PT users can access each system programming item. Default 000–009, 020–099: Enable 010–019, 100–999: Disable Value Range Disable, Enable Maintenance Console Location 2.16.2 [10-2] PT Programming Access Programming Manual References None Feature Manual References 1.13.15 PT Programming
3.1 Feature Programming References 438 PC Programming Manual 3.1 Feature Programming References A Absent Message 2.8.8 [2-6-1] Numbering Plan—Main—Features—Absent Message Set / Cancel 2.10.1 [4-1-1] Wired Extension—Extension Settings—Option 3—Absent Message 2.10.8 [4-2-1] Portable Station—Extension Settings—Option 3—Absent Message 2.12.5 [6-5] Absent Message Feature Manual Reference 1.1.1 Absent Message Account Code Entry 2.8.8 [2-6-1] Numbering Plan—Main—Features—Account Code Entry 2.8.11 [2-7-1] Class of Service—COS Settings—CO & SMDR—Account Code Mode Feature Manual Reference 1.1.2 Account Code Entry ARS (Automatic Route Selection) 2.4.3 Tool—Import – ARS - Leading Digit – ARS - Except Code – ARS - Routing Plan 2.4.4 Tool—Export 2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Extension Inter-digit 2.8.17 [2-9] System Options—Option 3—Dial Tone—Dial Tone for ARS 2.10.1 [4-1-1] Wired Extension—Extension Settings—Option 2—ARS Itemized Code 2.10.8 [4-2-1] Portable Station—Extension Settings—Option 2—ARS Itemized Code 2.12.3 [6-3] Verification Code—Itemized Billing Code for ARS 2.14 [8] ARS 2.16.1 [10-1] Main—SMDR—Options—ARS Dial Feature Manual Reference 1.1.3 ARS (Automatic Route Selection) Automatic Callback Busy (Camp-on) 2.8.8 [2-6-1] Numbering Plan—Main—Features—Automatic Callback Busy Cancel 2.8.10 [2-6-3] Numbering Plan—B/NA DND Call Feature—Automatic Callback Busy Feature Manual Reference 1.1.4 Automatic Callback Busy (Camp-on) Automatic Extension Release 2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone – Dial—Extension First Digit – Dial—Extension Inter-digit
3.1 Feature Programming References PC Programming Manual 439 – Tone Length—Reorder Tone for PT Handset – Tone Length—Reorder Tone for PT Hands-free Feature Manual Reference 1.1.5 Automatic Extension Release Automatic Fax Transfer 2.11.4 [5-3-2] Voice Message—DISA Message—Fax Extension Feature Manual Reference 1.1.6 Automatic Fax Transfer Automatic Time Adjustment 2.8.1 [2-1] Date & Time/Daylight Saving 2.8.17 [2-9] System Options—Option 2—Automatic Time Adjustment—by Caller ID (FSK) Feature Manual Reference 1.1.7 Automatic Time Adjustment B BGM (Background Music) 2.8.3 [2-2] Operator & BGM—BGM and Music on Hold—Music Source of BGM 2.8.8 [2-6-1] Numbering Plan—Main—Features – External BGM On / Off – BGM Set / Cancel 2.8.19 [2-11-1] Audio Gain—Paging/MOH—MOH—(Music On Hold) 2.11.2 [5-2] External Pager Feature Manual Reference 1.2.1 BGM (Background Music) C Caller ID 2.8.4 [2-3] Timers & Counters—Miscellaneous – Caller ID—Waiting to receive – Caller ID—Visual Caller ID Display 2.8.18 [2-10] Extension CID Settings 2.9.1 [3-1-1] Trunk Group—TRG Settings—Main—Caller-ID Modification Table 2.10.1 [4-1-1] Wired Extension—Extension Settings—Option 7 – Extension Caller ID Sending – Incoming Call Wait Timer for Extension Caller ID 2.12.1 [6-1] System Speed Dial 2.12.2 [6-2] Caller ID Modification Feature Manual Reference 1.3.1 Caller ID
3.1 Feature Programming References 440 PC Programming Manual Call Hold 2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone – Recall—Hold Recall – Recall—Disconnect after Recall 2.8.8 [2-6-1] Numbering Plan—Main—Features – Call Hold / Call Hold Retrieve – Call Hold Retrieve : Specified with a Holding Extension Number – Hold Retrieve : Specified with a Held CO Line Number 2.8.17 [2-9] System Options – Option 1—PT Operation—Automatic Hold by ICM / CO / ICD Group key – Option 1—PT Operation— Hold Key Mode – Option 4—SLT—SLT Hold Mode Feature Manual Reference 1.3.2 Call Hold Call Log, Incoming 2.10.1 [4-1-1] Wired Extension—Extension Settings – Option 5—Incoming Call Display – Option 6—Incoming Call Log Memory 2.10.4 [4-1-4] Wired Extension—Flexible Button—Ty p e 2.10.8 [4-2-1] Portable Station—Extension Settings – Option 5—Incoming Call Display – Option 6—Incoming Call Log Memory 2.10.13 [4-3] DSS Console—Flexible Button—Ty p e Feature Manual Reference 1.3.3 Call Log, Incoming Call Monitor 2.8.10 [2-6-3] Numbering Plan—B/NA DND Call Feature—Call Monitor 2.8.11 [2-7-1] Class of Service—COS Settings—CO & SMDR—Call Monitor 2.10.1 [4-1-1] Wired Extension—Extension Settings – Option 2—Data Mode – Option 3—Executive Override Deny 2.10.8 [4-2-1] Portable Station—Extension Settings—Option 3—Executive Override Deny Feature Manual Reference 1.3.4 Call Monitor Call Park 2.8.4 [2-3] Timers & Counters – Recall—Call Park Recall – Recall—Disconnect after Recall 2.8.8 [2-6-1] Numbering Plan—Main—Features—Call Park / Call Park Retrieve 2.10.4 [4-1-4] Wired Extension—Flexible Button – Ty p e – Parameter Selection (for Call Park)