2.10 [4] Extension PC Programming Manual 261 Pickup Dial Number Specifies the number to be dialed automatically after going off-hook when the Hot Line feature is active. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.8.6 Hot Line Data Mode Sets or cancels the protection against tones or interruptions from other extensions during communication. Default Off Value Range Off, On Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.4.1 Data Line Security Option 3 Slot Indicates the slot position of each extension card (reference only). Default Current slot number
2.10 [4] Extension 262 PC Programming Manual Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the port number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply. 2.Set the status of the extension port to OUS, then INS. When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the port is in use, the new extension number will not come into effect. Note that extensions that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Starting at 101 (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent extensions by adding one to the previous extension number.)
2.10 [4] Extension PC Programming Manual 263 Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the name of the extension. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Call Pickup Deny Specifies whether calls can be picked up by other extensions. Default Disable Value Range Disable: Allows other extension users to pick up calls to your extension Enable: Prevents other extension users from picking up calls to your extension Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None
2.10 [4] Extension 264 PC Programming Manual Feature Manual References 1.3.6 Call Pickup Executive Override Deny Specifies whether calls can be interrupted by other extensions. Default Disable Value Range Disable: Allows other extension users to interrupt an existing call Enable: Prevents other extension users from interrupting an existing call Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.5.3 Executive Busy Override Absent Message Specifies the Personal Absent Message which, unlike the System Absent Message, can be customized for each extension. Default Not stored. Value Range Max. 16 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.1.1 Absent Message Option 4 Slot Indicates the slot position of each extension card (reference only).
2.10 [4] Extension PC Programming Manual 265 Default Current slot number Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the por t number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply. 2.Set the status of the extension port to OUS, then INS. When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the por t is in use, the new extension number will not come into effect. Note that extensions that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits.
2.10 [4] Extension 266 PC Programming Manual Default Starting at 101 (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent extensions by adding one to the previous extension number.) Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the name of the extension. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Outgoing Preferred Line Selects the line to be seized after going off-hook to make a call. Default ICM Value Range No Line: No line is seized. Idle: An idle CO line is seized automatically from the programmed trunk groups. ICM: An extension line is seized.
2.10 [4] Extension PC Programming Manual 267 F-1–F-12: A CO line programmed for a flexible CO button (F-1–F-12) is seized. A flexible CO button customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected. Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.10.4 [4-1-4] Wired Extension—Flexible Button Feature Manual References 1.10.3 Line Preference—Outgoing Incoming Preferred Line Selects the line on which an incoming call is answered after going off-hook. Default Ringing Line Value Range No Line: No line is selected. Select a line by pressing the desired Line Access button to answer a call. Ringing Line: The longest ringing call is selected. F-1–F-12: The call arriving at a flexible CO button (F-1–F-12) is selected. A flexible CO button customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected. Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.10.4 [4-1-4] Wired Extension—Flexible Button Feature Manual References 1.10.2 Line Preference—Incoming Intercom Call by Voice Selects the method of receiving intercom calls. When Deny Voice Call is selected, the extension will always ring when receiving calls, regardless of how the caller wants to make the call. Default Tone Call Value Range Tone Call, Voice Call, Deny Voice Call Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings
2.10 [4] Extension 268 PC Programming Manual Programming Manual References None Feature Manual References 1.9.11 Intercom Call Call Waiting Tone Type Selects the type of Call Waiting tone sent to the busy extension. Default CW Tone 1 Value Range CW Tone 1, CW Tone 2 Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.3.9 Call Waiting Tone LCS Recording Mode Specifies whether to continue or stop recording the message in the extensions mailbox when the extension user answers a call that was being monitored. Default Stop Record Value Range Stop Record, Keep Record Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration LCS Answer Mode Specifies whether the extensions mailbox is monitored in Hands-free or Private mode.
2.10 [4] Extension PC Programming Manual 269 Default Hands free Value Range Hands free: Monitor through the built-in speaker Private: Monitor through the handset or the built-in speaker after hearing a warning tone Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.8.2 Hands-free Operation 1.19.4 Voice Mail DPT (Digital) Integration Display Language Selects the display language of the extension telephone. Default Language 1 Value Range Language1–Language5 Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.4.7 Display Information Option 5 Slot Indicates the slot position of each extension card (reference only). Default Current slot number Value Range Slot number
2.10 [4] Extension 270 PC Programming Manual Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the port number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply. 2.Set the status of the extension port to OUS, then INS. When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the port is in use, the new extension number will not come into effect. Note that extensions that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Starting at 101 (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent extensions by adding one to the previous extension number.) Value Range Max. 4 digits (consisting of 0–9)