    							2.10 [4] Extension
    PC Programming Manual 261
    Pickup Dial Number
    Specifies the number to be dialed automatically after going off-hook when the Hot Line feature is 
    active.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.8.6 Hot Line
    Data Mode
    Sets or cancels the protection against tones or interruptions from other extensions during 
    communication.
    Default
    Off
    Value Range
    Off, On
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.4.1 Data Line Security
    Option 3
    Slot
    Indicates the slot position of each extension card (reference only).
    Default
    Current slot number 
    						
    							2.10 [4] Extension
    262 PC Programming Manual
    Value Range
    Slot number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the port number (reference only).
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.4 [1-1] Slot—Extension Port
    Feature Manual References
    None
    Extension Number
    Specifies the extension number of the extension.
    To change the extension number of a wired extension, follow the steps below:
    1.Type the new extension number, then click Apply.
    2.Set the status of the extension port to OUS, then INS.
    When changing the extension number, make sure that the extension port is not in use. If the extension 
    number is changed while the port is in use, the new extension number will not come into effect.
    Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
    numbers of 2–4 digits.
    Default
    Starting at 101 
    (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent 
    extensions by adding one to the previous extension number.) 
    						
    							2.10 [4] Extension
    PC Programming Manual 263
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.5 [1-1] Slot—Extension Port—Port Command
    Feature Manual References
    None
    Extension Name
    Specifies the name of the extension.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Call Pickup Deny
    Specifies whether calls can be picked up by other extensions.
    Default
    Disable
    Value Range
    Disable: Allows other extension users to pick up calls to your extension 
    Enable: Prevents other extension users from picking up calls to your extension
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    264 PC Programming Manual
    Feature Manual References
    1.3.6 Call Pickup
    Executive Override Deny
    Specifies whether calls can be interrupted by other extensions.
    Default
    Disable
    Value Range
    Disable: Allows other extension users to interrupt an existing call 
    Enable: Prevents other extension users from interrupting an existing call
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.5.3 Executive Busy Override
    Absent Message
    Specifies the Personal Absent Message which, unlike the System Absent Message, can be 
    customized for each extension.
    Default
    Not stored.
    Value Range
    Max. 16 characters
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.1.1 Absent Message
    Option 4
    Slot
    Indicates the slot position of each extension card (reference only). 
    						
    							2.10 [4] Extension
    PC Programming Manual 265
    Default
    Current slot number
    Value Range
    Slot number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the por t number (reference only).
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.4 [1-1] Slot—Extension Port
    Feature Manual References
    None
    Extension Number
    Specifies the extension number of the extension.
    To change the extension number of a wired extension, follow the steps below:
    1.Type the new extension number, then click Apply.
    2.Set the status of the extension port to OUS, then INS.
    When changing the extension number, make sure that the extension port is not in use. If the extension 
    number is changed while the por t is in use, the new extension number will not come into effect.
    Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
    numbers of 2–4 digits. 
    						
    							2.10 [4] Extension
    266 PC Programming Manual
    Default
    Starting at 101 
    (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent 
    extensions by adding one to the previous extension number.)
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.5 [1-1] Slot—Extension Port—Port Command
    Feature Manual References
    None
    Extension Name
    Specifies the name of the extension.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Outgoing Preferred Line
    Selects the line to be seized after going off-hook to make a call.
    Default
    ICM
    Value Range
    No Line: No line is seized. 
    Idle: An idle CO line is seized automatically from the programmed trunk groups. 
    ICM: An extension line is seized.  
    						
    							2.10 [4] Extension
    PC Programming Manual 267
    F-1–F-12: A CO line programmed for a flexible CO button (F-1–F-12) is seized. A flexible CO button 
    customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.10.4 [4-1-4] Wired Extension—Flexible Button
    Feature Manual References
    1.10.3 Line Preference—Outgoing
    Incoming Preferred Line
    Selects the line on which an incoming call is answered after going off-hook.
    Default
    Ringing Line
    Value Range
    No Line: No line is selected. Select a line by pressing the desired Line Access button to answer a call. 
    Ringing Line: The longest ringing call is selected. 
    F-1–F-12: The call arriving at a flexible CO button (F-1–F-12) is selected. A flexible CO button 
    customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.10.4 [4-1-4] Wired Extension—Flexible Button
    Feature Manual References
    1.10.2 Line Preference—Incoming
    Intercom Call by Voice
    Selects the method of receiving intercom calls. When Deny Voice Call is selected, the extension will 
    always ring when receiving calls, regardless of how the caller wants to make the call.
    Default
    Tone Call
    Value Range
    Tone Call, Voice Call, Deny Voice Call
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings 
    						
    							2.10 [4] Extension
    268 PC Programming Manual
    Programming Manual References
    None
    Feature Manual References
    1.9.11 Intercom Call
    Call Waiting Tone Type
    Selects the type of Call Waiting tone sent to the busy extension.
    Default
    CW Tone 1
    Value Range
    CW Tone 1, CW Tone 2
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.9 Call Waiting Tone
    LCS Recording Mode
    Specifies whether to continue or stop recording the message in the extensions mailbox when the 
    extension user answers a call that was being monitored.
    Default
    Stop Record
    Value Range
    Stop Record, Keep Record
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    LCS Answer Mode
    Specifies whether the extensions mailbox is monitored in Hands-free or Private mode. 
    						
    							2.10 [4] Extension
    PC Programming Manual 269
    Default
    Hands free
    Value Range
    Hands free: Monitor through the built-in speaker 
    Private: Monitor through the handset or the built-in speaker after hearing a warning tone
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.8.2 Hands-free Operation
    1.19.4 Voice Mail DPT (Digital) Integration
    Display Language
    Selects the display language of the extension telephone.
    Default
    Language 1
    Value Range
    Language1–Language5
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.4.7 Display Information
    Option 5
    Slot
    Indicates the slot position of each extension card (reference only).
    Default
    Current slot number
    Value Range
    Slot number 
    						
    							2.10 [4] Extension
    270 PC Programming Manual
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the port number (reference only).
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.4 [1-1] Slot—Extension Port
    Feature Manual References
    None
    Extension Number
    Specifies the extension number of the extension.
    To change the extension number of a wired extension, follow the steps below:
    1.Type the new extension number, then click Apply.
    2.Set the status of the extension port to OUS, then INS.
    When changing the extension number, make sure that the extension port is not in use. If the extension 
    number is changed while the port is in use, the new extension number will not come into effect.
    Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
    numbers of 2–4 digits.
    Default
    Starting at 101 
    (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent 
    extensions by adding one to the previous extension number.)
    Value Range
    Max. 4 digits (consisting of 0–9) 
    						