    							2.9 [3] Group
    PC Programming Manual 211
    Programming Manual References
    2.10.2 [4-1-2] Wired Extension—FWD/DND
    2.10.9 [4-2-2] Portable Station—FWD / DND
    Feature Manual References
    1.4.8 DND (Do Not Disturb)
    1.9.2 ICD Group Features—Group Call Distribution
    Tenant Number
    Specifies the tenant to which the incoming call distribution group belongs, to determine the Time 
    Table and the audio source for the group. (The tenant number corresponds to the Time Table 
    number.)
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    2.8.3 [2-2] Operator & BGM
    2.8.5 [2-4] Week Table
    2.12.6 [6-6] Tenant—Music On Hold
    Feature Manual References
    1.11.4 Music on Hold
    1.17.2 Tenant Service
    COS
    Specifies the COS of the incoming call distribution group. Depending on the COS, calls from certain 
    extensions are restricted as determined by the Internal Call Block feature. Also, when calls are 
    forwarded or overflowed to a CO line, the TRS assigned for the COS of the incoming call distribution 
    group applies.
    Default
    1
    Value Range
    1–64
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings 
    						
    							2.9 [3] Group
    212 PC Programming Manual
    Programming Manual References
    2.8.11 [2-7-1] Class of Service—COS Settings
    2.8.12 [2-7-2] Class of Service—External Call Block
    2.8.13 [2-7-3] Class of Service—Internal Call Block
    Feature Manual References
    1.3.16 COS (Class of Service)
    1.9.12 Internal Call Block
    1.17.5 TRS (Toll Restriction)
    Overflow Queuing Busy
    Floating Extension Number
    Specifies the floating extension number of the incoming call distribution group.
    Default
    Groups 001-064: 601–664 
    Groups 065-128: Not stored
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Group Name
    Specifies the name of the incoming call distribution group.
    Default
    ICD Group 001–ICD Group 128
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None 
    						
    							2.9 [3] Group
    PC Programming Manual 213
    Feature Manual References
    None
    Queuing Busy—Destination-Day, Lunch, Break, Night
    Specifies the overflow destination of calls that cannot be queued in each time mode.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, [ ] [Secret], and P [Pause])
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.9.4 ICD Group Features—Overflow
    Queuing Busy—Queue Call Capacity
    Specifies the number of calls that can wait in a queue.
    Default
    30
    Value Range
    None, 1–30
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.5 ICD Group Features—Queuing
    Overflow No Answer
    Floating Extension Number
    Specifies the floating extension number of the incoming call distribution group. 
    						
    							2.9 [3] Group
    214 PC Programming Manual
    Default
    Groups 001-064: 601–664 
    Groups 065-128: Not stored
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Group Name
    Specifies the name of the incoming call distribution group.
    Default
    ICD Group 001–ICD Group 128
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Time out & Manual Queue Redirection—Destination-Day, Lunch, Break, 
    Night
    Specifies the overflow destination of queued calls when they are not answered or are redirected by 
    Manual Queue Redirection in each time mode.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, [ ] [Secret], and P [Pause]) 
    						
    							2.9 [3] Group
    PC Programming Manual 215
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.9.4 ICD Group Features—Overflow
    1.9.5 ICD Group Features—Queuing
    Time out & Manual Queue Redirection—Overflow Time
    Specifies the length of time calls wait in a queue before they are redirected to the overflow destination.
    Default
    None
    Value Range
    None, 10 × n (n=1–125) s
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.4 ICD Group Features—Overflow
    1.9.5 ICD Group Features—Queuing
    Hurry-up Level
    Specifies the number of calls to hold in the queue before prompting Manual Queue Redirection by 
    flashing the Hurry-up button.
    Default
    None
    Value Range
    None, 1–30
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    2.10.4 [4-1-4] Wired Extension—Flexible Button
    2.10.10 [4-2-3] Portable Station—Flexible Button 
    						
    							2.9 [3] Group
    216 PC Programming Manual
    Feature Manual References
    1.9.5 ICD Group Features—Queuing
    Queuing Time Table
    Floating Extension Number
    Specifies the floating extension number of the incoming call distribution group.
    Default
    Groups 001-064: 601–664 
    Groups 065-128: Not stored
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Group Name
    Specifies the name of the incoming call distribution group.
    Default
    ICD Group 001–ICD Group 128
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Queuing Time Table—Day, Lunch, Break, Night
    Specifies the Queuing Time Table to be used in each time mode. 
    						
    							2.9 [3] Group
    PC Programming Manual 217
    Default
    None
    Value Range
    None, Table 1–Table 64
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.9.5 ICD Group Features—Queuing
    Queuing Time Table When Extension Ringing
    Enables the PBX to play messages/BGM to the caller according to the Queuing Time Table, when the 
    call arrives at an extension without being queued or after being queued.
    Default
    Enable
    Value Range
    Disable (Ringback Tone), Enable
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.5 ICD Group Features—Queuing
    Miscellaneous
    Floating Extension Number
    Specifies the floating extension number of the incoming call distribution group.
    Default
    Groups 001-064: 601–664 
    Groups 065-128: Not stored
    Value Range
    Max. 4 digits (consisting of 0–9) 
    						
    							2.9 [3] Group
    218 PC Programming Manual
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Group Name
    Specifies the name of the incoming call distribution group.
    Default
    ICD Group 001–ICD Group 128
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Extension No Answer Redirection Time
    Specifies the length of time that a call queues at an extension before it is redirected to the next 
    member extension of the incoming call distribution group, in UCD or Priority Hunting distribution 
    method.
    Default
    None
    Value Range
    None, 10 × n (n=1–15) s
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.2 ICD Group Features—Group Call Distribution 
    						
    							2.9 [3] Group
    PC Programming Manual 219
    1.9.5 ICD Group Features—Queuing
    No. of Unanswered Calls for Automatic Log-out
    Specifies the number of consecutive unanswered calls before a member extension is automatically 
    logged out from the incoming call distribution group.
    Default
    None
    Value Range
    None, 1–15
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out
    Maximum No. of Busy Extensions
    Specifies the number of extensions that can accept calls simultaneously in the incoming call 
    distribution group.
    Default
    Max.
    Value Range
    Max: Call arrives at an idle extension. 
    1–32 : Call will not arrive at an idle extension when the number of busy extensions exceeds the 
    assigned number.
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.2 ICD Group Features—Group Call Distribution
    Last Extension Log-out
    Specifies whether the last extension logged-in to the incoming call distribution group is allowed to log 
    out. 
    						
    							2.9 [3] Group
    220 PC Programming Manual
    Default
    Enable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out
    VIP Call Mode
    Enables VIP Call mode, to prioritize calls received from multiple incoming call distribution groups.
    Default
    Disable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.6 ICD Group Features—VIP Call
    Programmed Mailbox No.
    Specifies the mailbox number of the incoming call distribution groups mailbox for Voice Processing 
    Systems (VPS) with DTMF Integration.
    Default
    Not stored.
    Value Range
    Max. 16 digits (consisting of 0–9, *, and #)
    Maintenance Console Location
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Kx Taw848 PC Cprogramming Manual