    							2.10 [4] Extension
    PC Programming Manual 311
    Programmed Mailbox No.
    Specifies the mailbox number of the PSs mailbox for Voice Processing Systems (VPS) with DTMF 
    Integration.
    Default
    Not stored.
    Value Range
    Max. 16 digits (consisting of 0–9, *, and #)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.19.5 Voice Mail DTMF Integration
    Transfer Recall Destination
    Specifies the transfer recall destination when an extension user transfers a call with the Call Transfer 
    without Announcement feature and the transferred call is not answered within a certain time period.
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.8 Call Transfer
    Option 2
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored. 
    						
    							2.10 [4] Extension
    312 PC Programming Manual
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Extension PIN
    Specifies the PIN of the PS.
    Default
    Not stored.
    Value Range
    Max. 10 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    PC Programming Manual 313
    Feature Manual References
    1.5.6 Extension PIN (Personal Identification Number)
    WARNING
    There is a risk that fraudulent telephone calls will be made if a third party 
    discovers a personal identification number (PIN) (verification code PIN or 
    extension PIN) of the PBX.
     
    The cost of such calls will be billed to the owner/renter of the PBX. 
    To protect the PBX from this kind of fraudulent use, we strongly recommend:
    a)Keeping PINs secret.
    b)Selecting complex, random PINs that cannot be easily guessed.
    c)Changing PINs frequently.
    ARS Itemized Code
    Specifies the itemized billing code used by the ARS feature for identifying the calls made from the PS 
    for accounting and billing purposes.
    Default
    Not stored.
    Value Range
    Max. 10 digits (consisting of 0–9, *, and #)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.14.6 [8-5] Carrier
    Feature Manual References
    1.1.3 ARS (Automatic Route Selection)
    1.19.1 Verification Code Entry
    C. Waiting for Call from Extension
    Selects the method of receiving call waiting notification from other extensions.
    Default
    BSS
    Value Range
    Off: No notification 
    BSS: Tone from the handset or built-in speaker
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings 
    						
    							2.10 [4] Extension
    314 PC Programming Manual
    Programming Manual References
    None
    Feature Manual References
    1.3.9 Call Waiting Tone
    C. Waiting for Call from CO
    Specifies whether to receive call waiting notification for a call from CO line, a doorphone call or a call 
    via an incoming call distribution group.
    Default
    On
    Value Range
    Off, On
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.9 Call Waiting Tone
    Pickup Dial Set
    Sets or cancels the Hot Line feature. The number specified in Pickup Dial Number on this screen is 
    dialed automatically after going off-hook when the Hot Line feature is active.
    Default
    Off
    Value Range
    Off, On
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Hot Line (Pickup Dial) Start
    Feature Manual References
    1.8.6 Hot Line 
    						
    							2.10 [4] Extension
    PC Programming Manual 315
    Pickup Dial Number
    Specifies the number to be dialed automatically after going off-hook when the Hot Line feature is 
    active.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.8.6 Hot Line
    Option 3
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS.
    Default
    Not stored. 
    						
    							2.10 [4] Extension
    316 PC Programming Manual
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Call Pickup Deny
    Specifies whether calls can be picked up by other extensions.
    Default
    Disable
    Value Range
    Disable: Allows other extension users to pick up calls to your PS 
    Enable: Prevents other extension users from picking up calls to your PS
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.6 Call Pickup
    Executive Override Deny
    Specifies whether calls can be interrupted by other extensions.
    Default
    Disable
    Value Range
    Disable: Allows other extension users to interrupt an existing call 
    Enable: Prevents other extension users from interrupting an existing call
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    PC Programming Manual 317
    Feature Manual References
    1.5.3 Executive Busy Override
    Absent Message
    Specifies the Personal Absent Message which, unlike the System Absent Message, can be 
    customized for each PS.
    Default
    Not stored.
    Value Range
    Max. 16 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.1.1 Absent Message
    Option 4
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS. 
    						
    							2.10 [4] Extension
    318 PC Programming Manual
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Outgoing Preferred Line
    Selects the line to be seized after going off-hook to make a call.
    Default
    ICM
    Value Range
    No Line: No line is seized. 
    Idle: An idle CO line is seized automatically from the programmed trunk groups. 
    ICM: An extension line is seized. 
    F-1–F-12: A CO line programmed for a flexible CO button (F-1–F-12) is seized. A flexible CO button 
    customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Feature Manual References
    1.10.3 Line Preference—Outgoing
    Incoming Preferred Line
    Selects the line on which an incoming call is answered after going off-hook.
    Default
    Ringing Line
    Value Range
    No Line: No line is selected. Select a line by pressing the desired Line Access button to answer a call. 
    Ringing Line: The longest ringing call is selected.  
    						
    							2.10 [4] Extension
    PC Programming Manual 319
    F-1–F-12: The call arriving at a flexible CO button (F-1–F-12) is selected. A flexible CO button 
    customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Feature Manual References
    1.10.2 Line Preference—Incoming
    Call Waiting Tone Type
    Selects the type of Call Waiting tone sent to the busy extension.
    Default
    CW Tone 1
    Value Range
    CW Tone1, CW Tone2
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.9 Call Waiting Tone
    LCS Recording Mode
    Specifies whether to continue or stop recording the message in the PSs mailbox when the PS user 
    answers a call that was being monitored.
    Default
    Stop Record
    Value Range
    Stop Record, Keep Record
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    320 PC Programming Manual
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    Display Language
    Selects the display language of the PS.
    Default
    Language 1
    Value Range
    Language1–Language5
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.4.7 Display Information
    Option 5
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Kx Taw848 PC Cprogramming Manual