2.8 [2] System PC Programming Manual 101 Value Range External BGM, Internal BGM 1, Internal BGM 2 Maintenance Console Location 2.8.3 [2-2] Operator & BGM Programming Manual References None Feature Manual References 1.2.1 BGM (Background Music) BGM and Music on Hold—Music on Hold Selects the audio source for Music on Hold. Default BGM Value Range To n e , B G M Maintenance Console Location 2.8.3 [2-2] Operator & BGM Programming Manual References None Feature Manual References 1.11.4 Music on Hold BGM and Music on Hold—Sound on Transfer Selects the audio source for Music for Transfer (either the same music source chosen for the Music on Hold, or ringback tone). Default Same as Music on Hold Value Range Same as Music on Hold, Ringback Tone Maintenance Console Location 2.8.3 [2-2] Operator & BGM Programming Manual References None
2.8 [2] System 102 PC Programming Manual Feature Manual References 1.3.8 Call Transfer 2.8.4 [2-3] Timers & Counters Various system timers and counters can be programmed. Dial / IRNA / Recall / Tone Dial—Hot Line (Pickup Dial) Start Specifies the length of time between going off-hook and the start of automatic dialing when the Hot Line feature is set. Default 1 s Value Range 0–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.8.6 Hot Line Dial—Extension First Digit Specifies the length of time after going off-hook within which the first digit of a feature number or destination must be dialed before a reorder tone is heard. Default 10 s Value Range 0–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None
2.8 [2] System PC Programming Manual 103 Feature Manual References 1.1.5 Automatic Extension Release Dial—Extension Inter-digit Specifies the length of time within which subsequent digits must be dialed before the PBX sends a reorder tone. Default 10 s Value Range 0–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.1.5 Automatic Extension Release Dial—Analog CO First Digit Specifies the length of time within which the first digit of a telephone number must be sent to an analog CO line. If no digit is sent before this time expires, the PBX recognizes end of dialing and stops muting the callers voice over the analog CO line. Default 10 s Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References None
2.8 [2] System 104 PC Programming Manual Dial—Analog CO Inter-digit Specifies the length of time within which subsequent digits of a telephone number must be sent to an analog CO line. If no digit is sent before this time expires, the PBX recognizes end of dialing and stops muting the callers voice over the analog CO line. Default 5 s Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References None Dial—Analog CO Call Duration Start Specifies the length of time between the end of dialing and the start of the SMDR timer for outgoing analog CO line calls. Default 0 s Value Range 0–60 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.16.1 SMDR (Station Message Detail Recording) Intercept Routing No Answer (IRNA)—Day, Lunch, Break, Night Specifies the length of time until an unanswered CO line call is redirected to the intercept routing destination in each time mode. Default 40 s
2.8 [2] System PC Programming Manual 105 Value Range 1–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.9.9 Intercept Routing Recall—Hold Recall Specifies the length of time until the holding extension receives a Hold Recall ring or alarm tone when a held call remains unretrieved. Default 60 s Value Range 0 (disable the Hold Recall)–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.3.2 Call Hold Recall—Transfer Recall Specifies the length of time that a transferred call waits to be answered, before being redirected to the Transfer Recall destination assigned to the original transferring extension. Default 60 s Value Range 1–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings
2.8 [2] System 106 PC Programming Manual 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.3.8 Call Transfer Recall—Call Park Recall Specifies the length of time that a parked call waits to be retrieved, before the Transfer Recall destination assigned to the extension that parked the call hears a Call Park Recall ring. Default 60 s Value Range 1–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.3.5 Call Park Recall—Disconnect after Recall Specifies the length of time after an extension with a CO line call on hold receives a Hold Recall tone that the held call is disconnected. Default 30 min Value Range 1–30 min Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.3.2 Call Hold
2.8 [2] System PC Programming Manual 107 Tone Length—Busy Tone / DND Tone Specifies the length of time that a busy/DND tone is heard when a call is made to an extension in busy status or DND mode. A reorder tone will be sent when this timer expires. (For a call through DISA, the call will be disconnected when this timer expires.) Default 10 s Value Range 0 (continuous)–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.4.8 DND (Do Not Disturb) Tone Length—Reorder Tone for PT Handset Specifies the length of time that a reorder tone is heard when using a PT handset. The PT will return to idle status when this timer expires. Default 10 s Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.1.5 Automatic Extension Release Tone Length—Reorder Tone for PT Hands-free Specifies the length of time that a reorder tone is heard from the built-in speaker of a PT in hands- free mode. The PT will return to idle status when this timer expires. This setting is applied to PSs as well as PTs. Default 3 s
2.8 [2] System 108 PC Programming Manual Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.1.5 Automatic Extension Release 1.8.2 Hands-free Operation DISA / Door / Reminder / U. Conf DISA—Delayed Answer Timer Specifies the length of time that the caller hears a ringback tone before hearing an OGM. Default 5 s Value Range 0–30 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA—Mute & OGM Start Timer after Answering Specifies the length of time until the caller hears an OGM after reaching the DISA line. Default 1.8 s Value Range 0.0–12.0 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters
2.8 [2] System PC Programming Manual 109 Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA—No Dial Intercept Timer Specifies the length of time after the OGM finishes playing in which the caller must begin dialing before the call is redirected to the operator. Default 10 s Value Range 0–120 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.8.3 [2-2] Operator & BGM 2.11.4 [5-3-2] Voice Message—DISA Message 2.12.6 [6-6] Tenant—Operator (Extension Number) Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA—2nd Dial Timer for AA Specifies the length of time in which the caller must dial the second digit before the DISA AA Service activates. Default 2 s Value Range 0–5 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access)
2.8 [2] System 110 PC Programming Manual DISA—Intercept Timer—Day, Lunch, Break, Night Specifies the length of time until an unanswered DISA call is intercepted and redirected to the intercept routing destination after the original destination receives the call in each time mode. Default 40 s Value Range 0–60 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.9.1 [3-1-1] Trunk Group—TRG Settings—Intercept—Intercept Destination—Day, Lunch, Break, Night 2.10.1 [4-1-1] Wired Extension—Extension Settings—Option 1—Intercept Destination—Day, Lunch, Break, Night 2.10.8 [4-2-1] Portable Station—Extension Settings—Option 1—Intercept Destination—Day, Lunch, Break, Night 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access) 1.9.9 Intercept Routing DISA—Disconnect Timer after Intercept Specifies the length of time that an intercepted DISA call rings at the intercept routing destination before being disconnected. Default 60 s Value Range 0–60 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access)