2.8 [2] System PC Programming Manual 191 Additional Local Trunk Access Code to Extension Caller ID Enables the PBX to automatically add a CO Line Access number to the received telephone number when sending the Caller ID number of an incoming CO line call to an SLT. Default Enable Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID Send Caller ID Date & Time to Extension Enables the PBX to send the date and time of an incoming call when sending Caller ID information to an SLT. Default Enable Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID Send Caller ID Name to Extension Enables the PBX to send the callers name when sending Caller ID information to an SLT. Default Enable
2.8 [2] System 192 PC Programming Manual Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID Send Caller ID Long Distance to Extension Enables the PBX to send a call qualifier (Long Distance) (if received from the CO line) when sending Caller ID information to an SLT. Default Enable Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID 2.8.19 [2-11-1] Audio Gain—Paging/MOH Gain levels for the External Pager/External BGM ports can be programmed. Paging—EPG (External Pager) Specifies the paging volume for the External Pager. Default -2 dB Value Range -15–15 dB
2.8 [2] System PC Programming Manual 193 Maintenance Console Location 2.8.19 [2-11-1] Audio Gain—Paging/MOH Programming Manual References 2.9.6 [3-4] Paging Group Feature Manual References 1.13.1 Paging MOH—(Music On Hold) Specifies the music volume for the External BGM. Default 9 dB Value Range -11–11 dB Maintenance Console Location 2.8.19 [2-11-1] Audio Gain—Paging/MOH Programming Manual References 2.8.3 [2-2] Operator & BGM Feature Manual References 1.2.1 BGM (Background Music) 1.11.4 Music on Hold
2.9 [3] Group 194 PC Programming Manual 2.9 [3] Group 2.9.1 [3-1-1] Trunk Group—TRG Settings CO lines can be organized into trunk groups. The settings of each trunk group determine the settings of the CO lines within that group. A maximum of 64 trunk groups can be programmed. For more information on trunk groups, see 1.7.1 GROUP FEATURES in the Feature Manual. Main Group Name Specifies the name of the trunk group for programming reference. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References None COS Specifies the COS of the trunk group. If you wish to prevent such calls from being made, ensure that the COS specified here has a TRS level of 7 assigned for all relevant time modes in 2.8.11 [2-7-1] Class of Service—COS Settings. Default 7 Value Range 1–64 Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings
2.9 [3] Group PC Programming Manual 195 2.15.1 [9-1] CO Line Settings Feature Manual References None Line Hunting Order Specifies the CO line hunting sequence for the trunk group. The hunting sequence can be programmed to start from the lowest or highest numbered CO lines, or to rotate uniformly among all CO lines. Default High -> Low Value Range High -> Low, Low -> High, Rotation Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.11 CO Line Access CO-CO Duration Time Specifies the length of time that a CO-to-CO line call line call can be maintained before being disconnected. Default 10 min Value Range None, 1–60 min Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.12 CO Line Call Limitation
2.9 [3] Group 196 PC Programming Manual Extension-CO Duration Time Specifies the length of time that an extension-to-CO line call can be maintained before being disconnected. Default 10 min Value Range None, 1–60 min Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings 2.8.17 [2-9] System Options 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.12 CO Line Call Limitation Caller-ID Modification Table Specifies the table to be used for modifying caller information (telephone number). Default 1 Value Range 1–4 Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.12.2 [6-2] Caller ID Modification 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.1 Caller ID Tone Detection Group Name Specifies the name of the trunk group for programming reference.
2.9 [3] Group PC Programming Manual 197 Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References None DISA Tone Detection—Silence Enables the disconnection of a DISA-originated CO-to-CO line call line call by silence detection. Default Disable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.11.3 [5-3-1] Voice Message—DISA System 2.15.1 [9-1] CO Line Settings Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA Tone Detection—Continuous Enables the disconnection of a DISA-originated CO-to-CO line call line call by continuous signal detection. Default Enable Value Range Disable, Enable
2.9 [3] Group 198 PC Programming Manual Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.11.3 [5-3-1] Voice Message—DISA System 2.15.1 [9-1] CO Line Settings Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA Tone Detection—Cyclic Enables the disconnection of a DISA-originated CO-to-CO line call line call by cyclic signal detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.11.3 [5-3-1] Voice Message—DISA System 2.15.1 [9-1] CO Line Settings Feature Manual References 1.4.6 DISA (Direct Inward System Access) Simplified Voice Message Tone Detection—Silence Enables the disconnection of an SVM-originated CO-to-CO line call by silence detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None
2.9 [3] Group PC Programming Manual 199 Feature Manual References 1.16.5 SVM (Simplified Voice Message) Simplified Voice Message Tone Detection—Continuous Enables the disconnection of an SVM-originated CO-to-CO line call by continuous signal detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Simplified Voice Message Tone Detection—Cyclic Enables the disconnection of an SVM-originated CO-to-CO line call by cyclic signal detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Intercept Group Name Specifies the name of the trunk group for programming reference.
2.9 [3] Group 200 PC Programming Manual Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References None Intercept Destination—Day, Lunch, Break, Night Specifies the intercept routing destination of unanswered calls (whose original destination is the floating extension number of a PS Ring Group, VM Group, External Pager [TAFAS], or DISA) in each time mode. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, [ ] [Secret], and P [Pause]) Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.8.5 [2-4] Week Table 2.15.1 [9-1] CO Line Settings Feature Manual References 1.9.9 Intercept Routing Host PBX Access Code Group Name Specifies the name of the trunk group for programming reference. Default Not stored.