2.8 [2] System PC Programming Manual 111 DISA—CO-to-CO Call Prolong Counter Specifies the number of times that the caller can prolong a CO-to-CO line call on a DISA line. (Selecting 0 enables the caller to prolong the CO-to-CO line call without restriction.) Default 10 Value Range 0–15 Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA—CO-to-CO Call Prolong Time Specifies the length of time that a CO-to-CO line call on a DISA line is prolonged each time that the caller prolongs the call. (Selecting 0 prevents the caller from prolonging the CO-to-CO line call.) Default 3 min Value Range 0–7 min Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA—Progress Tone Continuation Time before Recording Message Specifies the length of time that a progress tone is sent to the manager extension before recording an OGM. Default 5 s
2.8 [2] System 112 PC Programming Manual Value Range 0–7 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.12.1 OGM (Outgoing Message) DISA—Reorder Tone Duration Specifies the length of time that a reorder tone is sent to the caller before the call is disconnected. Default 10 s Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.4 [5-3-2] Voice Message—DISA Message Feature Manual References 1.4.6 DISA (Direct Inward System Access) Doorphone—Call Ring Duration Specifies the length of time that a call from a doorphone rings until the call is cancelled when there is no answer. Default 30 s Value Range 10 × n (n=1–15) s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.1 [5-1] Doorphone
2.8 [2] System PC Programming Manual 113 Feature Manual References 1.4.10 Doorphone Call Doorphone—Call Duration Specifies the length of time until an answered doorphone call is disconnected. Default 60 s Value Range 10 × n (n=0–30) s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.1 [5-1] Doorphone Feature Manual References 1.4.10 Doorphone Call Doorphone—Open Duration Specifies the length of time that a door stays unlocked after being opened from an extension. Default 5 s Value Range 2–7 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.11.1 [5-1] Doorphone Feature Manual References 1.4.9 Door Open Timed Reminder—Repeat Counter Specifies the number of times that an alarm is repeated. Default 3
2.8 [2] System 114 PC Programming Manual Value Range 1–15 Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.17.3 Timed Reminder Timed Reminder—Interval Time Specifies the length of time between the repeated alarms. Default 30 s Value Range 10 × n (n=1–120) s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.17.3 Timed Reminder Timed Reminder—Alarm Ringing Duration Specifies the length of time that an alarm rings. Default 30 s Value Range 10 × n (n=1–30) s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None
2.8 [2] System PC Programming Manual 115 Feature Manual References 1.17.3 Timed Reminder Unattended Conference—Recall Start Timer Specifies the length of time until the conference originator receives an Unattended Conference Recall tone. Default 10 min Value Range 0–60 min Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.3.13 Conference Unattended Conference—Warning Tone Start Timer Specifies the length of time until the parties involved in an Unattended Conference receive a warning tone after the conference originator receives the Unattended Conference Recall tone but does not return to the conference. Default 30 s Value Range 0–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.3.13 Conference
2.8 [2] System 116 PC Programming Manual Unattended Conference—Disconnect Timer Specifies the length of time until an Unattended Conference is disconnected after the parties involved in the conference receive a warning tone but the conference originator does not return to the conference. Default 15 s Value Range 0–240 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.3.13 Conference Miscellaneous Caller ID—Waiting to receive Specifies the length of time that the PBX waits to receive Caller ID from an analog CO line. If the Caller ID is received through an analog CO line card on which no Caller ID card is mounted or through a port to which Caller ID Detection is disabled, this timer is not applicable. Default 5 s Value Range 0–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References 2.12.1 [6-1] System Speed Dial 2.12.2 [6-2] Caller ID Modification Feature Manual References 1.3.1 Caller ID
2.8 [2] System PC Programming Manual 117 Caller ID—Visual Caller ID Display Specifies the length of time that a Caller ID number, with the Call Waiting tone offered by an analog line from the telephone company, is shown on the display. The Caller ID number flashes on the display for five seconds, followed by a 10-second pause, then flashes again for five seconds. Default 30 s Value Range 0–250 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.3.1 Caller ID 1.3.9 Call Waiting Tone Extension PIN—Lock Counter Specifies the number of successive incorrect PIN entries allowed before the extension PIN is locked. A locked extension PIN can not be used until reset from the extension assigned as manager. (Specifying None disables this counter.) Default None Value Range None, 1–15 Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.5.6 Extension PIN (Personal Identification Number) 1.19.1 Verification Code Entry 1.20.1 Walking COS External Sensor—Ring Duration Specifies the length of time that the PBX waits for the called party to answer before cancelling a sensor call.
2.8 [2] System 118 PC Programming Manual Default 30 s Value Range 10 × n (n=1–15) s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.5.9 External Sensor PT Display—PT Last Display Duration in Idle Mode Specifies the length of time that the current information remains on the display after the extension returns to idle status. Default 5 s Value Range 1–15 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References None Voice Mail (Caller from VM to CO)—On-hook Wait Time Specifies the length of time from when the VPS seizes a CO line (for example, to transfer a call) until the VPS goes on hook. If the time specified here is too short, the VPS will be unable to dial the number and make a connection. Default 10 s Value Range 1–30 s
2.8 [2] System PC Programming Manual 119 Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.19.3 Voice Mail (VM) Group During Conversation—DTMF Signal Length Specifies the length of time that a DTMF signal is sent when a number is dialed from a PT or PS during a conversation. Default 160 ms Value Range 80 ms, 160 ms, 240 ms, 320 ms Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References None During Conversation—DTMF Inter-digit Pause Specifies the length of time between DTMF signals when numbers are dialed in succession from a PT or PS during a conversation. Default 112 ms Value Range 64 + 16 × n (n=0–15) ms Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References None
2.8 [2] System 120 PC Programming Manual During Conversation—Pause Signal Time Specifies the length of the pause inserted when the PAUSE button is pressed during a conversation. Default 1.5 s Value Range 1.5 s, 2.5 s, 3.5 s, 4.5 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References 1.13.4 Pause Insertion System Wireless—PS Out of Range Timer *) If 0 is set, timer is controlled by cell station. When the destination of an incoming call is a PS, specifies the length of time the PBX searches for the PS before setting its status to Out of Range. If 0 is assigned, the timer is controlled by the cell station. Default 0 s Value Range 0 s, 4 s, 8 s Maintenance Console Location 2.8.4 [2-3] Timers & Counters Programming Manual References None Feature Manual References None SVM—Recording Time Specifies the maximum length of a message recorded by the SVM feature. Default 120 s