    							2.8 [2] System
    PC Programming Manual 111
    DISA—CO-to-CO Call Prolong Counter
    Specifies the number of times that the caller can prolong a CO-to-CO line call on a DISA line. 
    (Selecting 0 enables the caller to prolong the CO-to-CO line call without restriction.)
    Default
    10
    Value Range
    0–15
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.11.4 [5-3-2] Voice Message—DISA Message
    Feature Manual References
    1.4.6 DISA (Direct Inward System Access)
    DISA—CO-to-CO Call Prolong Time
    Specifies the length of time that a CO-to-CO line call on a DISA line is prolonged each time that the 
    caller prolongs the call. (Selecting 0 prevents the caller from prolonging the CO-to-CO line call.)
    Default
    3 min
    Value Range
    0–7 min
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.11.4 [5-3-2] Voice Message—DISA Message
    Feature Manual References
    1.4.6 DISA (Direct Inward System Access)
    DISA—Progress Tone Continuation Time before Recording Message
    Specifies the length of time that a progress tone is sent to the manager extension before recording 
    an OGM.
    Default
    5 s 
    						
    							2.8 [2] System
    112 PC Programming Manual
    Value Range
    0–7 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.11.4 [5-3-2] Voice Message—DISA Message
    Feature Manual References
    1.12.1 OGM (Outgoing Message)
    DISA—Reorder Tone Duration
    Specifies the length of time that a reorder tone is sent to the caller before the call is disconnected.
    Default
    10 s
    Value Range
    1–15 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.11.4 [5-3-2] Voice Message—DISA Message
    Feature Manual References
    1.4.6 DISA (Direct Inward System Access)
    Doorphone—Call Ring Duration
    Specifies the length of time that a call from a doorphone rings until the call is cancelled when there 
    is no answer.
    Default
    30 s
    Value Range
    10 × n (n=1–15) s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.11.1 [5-1] Doorphone 
    						
    							2.8 [2] System
    PC Programming Manual 113
    Feature Manual References
    1.4.10 Doorphone Call
    Doorphone—Call Duration
    Specifies the length of time until an answered doorphone call is disconnected.
    Default
    60 s
    Value Range
    10 × n (n=0–30) s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.11.1 [5-1] Doorphone
    Feature Manual References
    1.4.10 Doorphone Call
    Doorphone—Open Duration
    Specifies the length of time that a door stays unlocked after being opened from an extension.
    Default
    5 s
    Value Range
    2–7 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.11.1 [5-1] Doorphone
    Feature Manual References
    1.4.9 Door Open
    Timed Reminder—Repeat Counter
    Specifies the number of times that an alarm is repeated.
    Default
    3 
    						
    							2.8 [2] System
    114 PC Programming Manual
    Value Range
    1–15
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.17.3 Timed Reminder
    Timed Reminder—Interval Time
    Specifies the length of time between the repeated alarms.
    Default
    30 s
    Value Range
    10 × n (n=1–120) s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.17.3 Timed Reminder
    Timed Reminder—Alarm Ringing Duration
    Specifies the length of time that an alarm rings.
    Default
    30 s
    Value Range
    10 × n (n=1–30) s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None 
    						
    							2.8 [2] System
    PC Programming Manual 115
    Feature Manual References
    1.17.3 Timed Reminder
    Unattended Conference—Recall Start Timer
    Specifies the length of time until the conference originator receives an Unattended Conference Recall 
    tone.
    Default
    10 min
    Value Range
    0–60 min
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.3.13 Conference
    Unattended Conference—Warning Tone Start Timer
    Specifies the length of time until the parties involved in an Unattended Conference receive a warning 
    tone after the conference originator receives the Unattended Conference Recall tone but does not 
    return to the conference.
    Default
    30 s
    Value Range
    0–240 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.3.13 Conference 
    						
    							2.8 [2] System
    116 PC Programming Manual
    Unattended Conference—Disconnect Timer
    Specifies the length of time until an Unattended Conference is disconnected after the parties involved 
    in the conference receive a warning tone but the conference originator does not return to the 
    conference.
    Default
    15 s
    Value Range
    0–240 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.3.13 Conference
    Miscellaneous
    Caller ID—Waiting to receive
    Specifies the length of time that the PBX waits to receive Caller ID from an analog CO line. If the 
    Caller ID is received through an analog CO line card on which no Caller ID card is mounted or through 
    a port to which Caller ID Detection is disabled, this timer is not applicable.
    Default
    5 s
    Value Range
    0–15 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    2.12.1 [6-1] System Speed Dial
    2.12.2 [6-2] Caller ID Modification
    Feature Manual References
    1.3.1 Caller ID 
    						
    							2.8 [2] System
    PC Programming Manual 117
    Caller ID—Visual Caller ID Display
    Specifies the length of time that a Caller ID number, with the Call Waiting tone offered by an analog 
    line from the telephone company, is shown on the display. The Caller ID number flashes on the display 
    for five seconds, followed by a 10-second pause, then flashes again for five seconds.
    Default
    30 s
    Value Range
    0–250 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.3.1 Caller ID
    1.3.9 Call Waiting Tone
    Extension PIN—Lock Counter
    Specifies the number of successive incorrect PIN entries allowed before the extension PIN is locked. 
    A locked extension PIN can not be used until reset from the extension assigned as manager. 
    (Specifying None disables this counter.)
    Default
    None
    Value Range
    None, 1–15
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.5.6 Extension PIN (Personal Identification Number)
    1.19.1 Verification Code Entry
    1.20.1 Walking COS
    External Sensor—Ring Duration
    Specifies the length of time that the PBX waits for the called party to answer before cancelling a 
    sensor call. 
    						
    							2.8 [2] System
    118 PC Programming Manual
    Default
    30 s
    Value Range
    10 × n (n=1–15) s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.5.9 External Sensor
    PT Display—PT Last Display Duration in Idle Mode
    Specifies the length of time that the current information remains on the display after the extension 
    returns to idle status.
    Default
    5 s
    Value Range
    1–15 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    None
    Voice Mail (Caller from VM to CO)—On-hook Wait Time
    Specifies the length of time from when the VPS seizes a CO line (for example, to transfer a call) until 
    the VPS goes on hook. If the time specified here is too short, the VPS will be unable to dial the 
    number and make a connection.
    Default
    10 s
    Value Range
    1–30 s 
    						
    							2.8 [2] System
    PC Programming Manual 119
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.19.3 Voice Mail (VM) Group
    During Conversation—DTMF Signal Length
    Specifies the length of time that a DTMF signal is sent when a number is dialed from a PT or PS 
    during a conversation.
    Default
    160 ms
    Value Range
    80 ms, 160 ms, 240 ms, 320 ms
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    None
    During Conversation—DTMF Inter-digit Pause
    Specifies the length of time between DTMF signals when numbers are dialed in succession from a 
    PT or PS during a conversation.
    Default
    112 ms
    Value Range
    64 + 16 × n (n=0–15) ms
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    None 
    						
    							2.8 [2] System
    120 PC Programming Manual
    During Conversation—Pause Signal Time
    Specifies the length of the pause inserted when the PAUSE button is pressed during a conversation.
    Default
    1.5 s
    Value Range
    1.5 s, 2.5 s, 3.5 s, 4.5 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    1.13.4 Pause Insertion
    System Wireless—PS Out of Range Timer *) If 0 is set, timer is controlled 
    by cell station.
    When the destination of an incoming call is a PS, specifies the length of time the PBX searches for 
    the PS before setting its status to Out of Range.
     
    If 0 is assigned, the timer is controlled by the cell station.
    Default
    0 s
    Value Range
    0 s, 4 s, 8 s
    Maintenance Console Location
    2.8.4 [2-3] Timers & Counters
    Programming Manual References
    None
    Feature Manual References
    None
    SVM—Recording Time
    Specifies the maximum length of a message recorded by the SVM feature.
    Default
    120 s 
    						