Home > Panasonic > System > Panasonic Digital Imaging System For Copier Dp 6000 Operating Instructions

Panasonic Digital Imaging System For Copier Dp 6000 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Digital Imaging System For Copier Dp 6000 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							8-7  Emptying the Punch Scrap Container209
    Daily Care
    8
    Empty all the scraps.
    Insert the Punch Scrap
    Container and push it into
    the machine.
    Close the Front Door of the
    Finisher.
    You must dispose of all the scraps in
    the container even if you have just
    pulled the container out a little.  This
    is because the machine will sense
    that the container has been pulled
    out.  If you do not dispose of the
    scraps, the container may be full
    before the next punch scrap
    container disposal message is
    displayed thus causing the machine
    to fail. 
    						
    							8-8  Checking the Billing Meter210
    Daily Care
    8
    Checking the Billing Meter
    You can check the meter on the Settings/Meter Check screen.
    Current Count .......Shows the number of copies made up till the present
    time.
    Procedure
    Press Settings/Meter Check.
    Select Meter Check.
    The following types of copies are not
    counted:
    ¥Blank sheets inserted by the
    machine.
    (A blank sheet is automatically
    inserted if the total number of
    sheets of the documents is an odd
    number for 2 Sided.)
    ¥First and last blank pages when
    making copies by using Book
    Duplex feature.
    ¥Separators for transparencies
    when the Transparency
    Separators feature is used.
    ¥Jammed papers or partially done
    copies as a result of machine fault.
    ¥Paper which is fed for fuser
    cleaning
    On a model with the printer function
    installed, the number of copies
    printed by using this function can be
    displayed. To use this function,
    contact your local authorized
    Panasonic service representative.
    9-3:  Confirming the Account Data
    for information on how to confirm the
    account data of each user when the
    Auditron feature is used.
    The screen on the right is displayed
    when the Auditron feature is
    enabled.  See 
    Chapter 9 Using the
    Auditron Feature
     for details. 
    						
    							8-8  Checking the Billing Meter211
    Daily Care
    8
    Check the reading.
    Select Close until the default screen is shown.
    The Settings/Meter Check screen clears and the default screen re-appears. 
    						
    							8-9  Making Clean Copies212
    Daily Care
    8
    Making Clean Copies
    Regular cleaning of the internal parts of the machine helps in producing
    clean copies every time.  This machine is equipped with a feature that
    allows plain paper to be fed for automatically removing dirt, which easily
    accumulates on the fuser unit and other internal parts.
    Procedure
    If paper other than plain paper are loaded in the trays,
    temporarily remove them.  Confirm that plain paper is loaded in
    any of the trays other than Tray 5 (Bypass).
     Press Settings/Meter Check.
    Select Fuser Cleaning.
    The paper which is fed for fuser
    cleaning depends on the sizes of
    paper loaded in the trays.  Paper will
    be automatically fed based on the
    following priority:
    (1) One sheet of A3
    (2) Two sheets of A4
    (3) Two sheets of paper in portrait
    orientation with greatest length.
    The paper used for fuser cleaning
    will not be recorded by the billing
    meter.
    If your copy volume is large, it is
    possible to set fuser cleaning to
    activate automatically.  Contact your
    local authorized Panasonic service
    representative. 
    						
    							8-9  Making Clean Copies213
    Daily Care
    8
    Select Start.
    If fuser unit is not warmed up, wait a while for cleaning to begin.
    The following screen is displayed while the fuser cleaning is in progress.
    No copy job can be done during this time.
    After the end of fuser cleaning, the Fuser Cleaning screen re-appears.
     Select Close until the default screen is shown.
    The Settings/Meter Check screen clears and the default screen re-appears. 
    						
    							This page is intentionally left blank. 
    						
    							9-1 Auditron ...................................................................... 216
    9-2 Displaying the Auditron Administration Mode Screen . 218
    9-3 Confirming the Account Data ...................................... 220
    9-4 Editing the Account Data ............................................ 223
    9-5 Deleting the Account Data .......................................... 227
    9-6 Enabling/Disabling Auditron ........................................ 229
    9-7 Defining Automatic Display of the Password Entry
    Screen ........................................................................ 231
    9-8 Changing the Auditron Access Number ...................... 233
    9
    Using the Auditron Feature 
    						
    							9-1  Auditron216
    Using the Auditron Feature
    9
    Auditron
    When the Auditron mode is enabled, the copy volume of each account user
    can be calculated.  This is done by assigning a Password to each account
    user.
    The relationship between the Password Entry screen and a normal
    screen is as shown below.
    Using the Auditron Mode
    In the Auditron Administration Mode, select On for Auditron Mode on the
    Auditron Setup screen and register a Password for every account by using
    the Create/Modify Accounts screen.
    9-4: Editing the Account Data
    9-6: Enabling/Disabling Auditron 
    						
    							9-1  Auditron217
    Using the Auditron Feature
    9
    The following operations can be done in the Auditron Administration mode.
    Item Description
    Reviewing the Account Data The password, copy limit and current copy volume
    settings can be reviewed for every account.
    ¥ 9-3: Confirming the Account Data
    Creating/Modifying Account Data The password and copy limit of each account
    can be created/modified.
    Up to 300 accounts can be registered.
    ¥ 9-4: Editing the Account Data
    Deleting the Account Data The copy volume, copy limit and password
    settings of each account can be deleted for all
    accounts and set to zero.  You can also choose
    to delete only the copy volume and copy limit.
    ¥ 9-5: Deleting the Account Data
    Enabling the Auditron Feature You can choose to enable/disable the Auditron
    Mode.  Select On for Auditron Mode on the
    Auditron Setup screen to enable it.  When power
    is switched on after exiting from the Settings/Meter
    Check screen, the Password Entry screen will be
    displayed.
    ¥ 9-6: Enabling/Disabling Auditron
    Defining the Automatic Display You can define the timeout period to automatically
    of Password Entry Screen display the Password Entry screen after a copy
    job is completed.
    ¥ 9-7: Defining Automatic Display of the Password
        Entry Screen
    Changing the Access Number You can change the Access Number of the
    Auditron Administrator using 4 to 12 digits.
      ¥ 9-8: Changing the Auditron Access Number
    2-sided copy volume and print
    volume can be calculated. To use
    this feature, contact your local
    authorized Panasonic service
    representative.
    Copy limit refers to the setting of the
    maximum number of copies which
    can be made. 
    						
    							9-2  Displaying the Auditron Administration Mode Screen218
    Using the Auditron Feature
    9
    Displaying the Auditron Administration Mode Screen
    This section explains the procedures for displaying the Auditron
    Administration Mode screen.
    Procedure
    Press Settings/Meter Check.
    Select Auditron Admin. Mode.
    Enter the Access Number of the Auditron Administrator and
    select Confirm.
    Each input digit is represented by an asterisk.
    The Auditron Administration Mode screen is displayed.
    Displaying the Auditron
    Administration Mode Screen
    If you made a mistake while entering
    the Access Number, press the Clear
    C button to clear and re-enter.
    The factory default is Ò11111Ó.
    9-8:  Changing the Auditron Access
    Number
     for information on how to
    change the Access Number of the
    Auditron Administrator.
    The screen on the right has the
    Auditron mode enabled. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Digital Imaging System For Copier Dp 6000 Operating Instructions