    							 NEAX2000 IVS2 ISDN System ManualPage 60  ND-70919 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN Terminal
    Figure 2-15  Example of MDF Cross Connection for ILC
    1
    2
    3
    4
    5
    6
    7 8
    Pin No.
    LT 0 0PIM0
    ILC J PLT C 0
    RA0
    TB1 RB1
    TB0
    RB0
    TA 0
    RA1
    TA 11
    29 28
    27
    26
    2
    3
    41
    29 28
    27
    26
    2
    3
    4
    MDF
    RA
    RB
    TA
    TB RECEIVE
    SEND3
    6
    4
    5TO ISDN
    TERMINAL
    1RA26RBLT C  ( J )
    2TA27TB
    328
    429
    26 RB 1 RA
    27 TB 2 TA
    28 3
    29 4
    Pin No. PBX Direction of Signal Terminal
    1
    2
    3RA←TA
    4TA→RA
    5TB→RB
    6RB←TB
    7
    8Not Used
    Not Used
    Modular Connector
    LT C  ( P ) 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure for Event Based CCIS
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 61
    INSTALLATION PROCEDURE FOR EVENT BASED CCIS
    Install the equipment for Event Based CCIS according to the procedure shown in Figure 2-16.
    NOTE:For Call Recording of ISDN call, install the equipment for SMDR/CIS. For details, refer
    to the Installation Procedure Manual.
    Figure 2-16  Installation Procedure for Event Based CCIS
    END START
    Mounting 
    PRT Card or BRT Card
    DTI/PRT/BRT Card Cable 
    Connection via MDF
    Selection of PLO in
    MP Card DTI and DCH Card/
    Mounting CCH CardDTI/DCH/PRT See Page 42.
    BRT See Page 50.
    See CHAPTER 4.
    See Page 62.
    or via CONN CardDTI/PRT SeePage 44.
    CONN SeePage 47.
    BRT See Page 51. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 62  ND-70919 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure for Event Based CCIS
    Mounting CCH Card
    (1) Before mounting the CCH (PN-SC00) card, set the MB switch to UP 
    position, and set the other switches to appropriate position.
    See CHAPTER 4.
    (2) Mount the CCH card in the following AP slots:
    PIM0-7: AP00-AP11
    The AP11 slot on PIM0 is available only when the FP card is not mounted in the FP11 slot 
    on PIM0.
    (3) After mounting the card, set the MB switch to DOWN position to put the card in service.
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 63
    CHAPTER 3
    SYSTEM DATA 
    PROGRAMMING
    This chapter explains the programming procedure to provide the ISDN
    feature to the PBX. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 64  ND-70919 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    How to Read This Chapter
    HOW TO READ THIS CHAPTER
    In the programming procedure, the meaning of (1), (2), and markings are as follows:
    (1) : 1st Data
    (2) : 2nd Data
    : Initial Data
    With the system data clear command (CM00, CM01), the data with this marking is
    automatically assigned for each command.
    : System Initialization
    A reset of the MP card is required after data setting.
    Press SW1 switch on the MP card.
    : DTI Initialization
    A reset of the DTI/PRT card is required after data setting.
    Set the Make Busy switch to UP and then Down.
    : DCH Initialization
    A reset of the DCH card is required after data setting.
    Set the Make Busy switch to UP and then Down.
    INITIAL
    DTI INITIAL
    DCH INITIAL 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    ISDN-PRI Programming
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 65
    ISDN-PRI PROGRAMMING
    Digital Trunk Data Assignment
    DESCRIPTION DATA
    Assign an AP number to the DTI/PRT 
    card. 
    The AP number must match the SENSE 
    switch setting on the DTI/PRT card.
    (1)
    (2)Y=0
    04-15, 20-31: AP No.
    09: DTI card
    12: PRT card
    Specify the AP highway channel for 24DTI/
    PRT card.
    (1)
    (2)Y=1
    04-15, 20-31: AP No.
    0 : Expanded Highway channel 
    (128 time slots)
    1 : Basic Highway channel 
    (128 time slots)
    Assign trunk numbers to each channel 
    number on the DTI/PRT card.
    The system allocates time slots to 
    consecutive channels from lowest to 
    highest channel number assigned. To 
    minimize the number of time slots 
    allocated, assign trunk numbers to the 
    consecutive channels on each card.
    Never skip channels in CM07.
    (1)
    (2)YY=01
    XX ZZ 
    XX: 04-15, 20-31: AP No. assigned by 
    CM05
    ZZ: 00-23: Channel No. of 24DTI/PRT
    01-15, 17-31: Channel No. of 
    30DTI
    D000-D255: Trunk No.
    Any trunk No. already assigned by 
    CM10 cannot be used.
    Allow second Dial Tone when dialing 
    access code assigned by CM20 for ISDN 
    B channel route.
    (1)
    (2)Y=2
    04
    0 : For ISDN trunk route, 2
    nd Dial Tone 
    is provided.
    1: No 2
    nd Dial Tone
    CM07 START
    CM05
    A
    CM48
    INITIAL
    INITIAL
    INITIAL 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 66  ND-70919 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    ISDN-PRI Programming
    DESCRIPTION DATA
    Assign the necessary functions to the DTI/
    PRT card. CMAA YY=00/01/02 assign-
    ment is required only for 24DTI/PRT.
    After entering the data, set the MB switch 
    on the DTI/PRT card to UP, and then to 
    DOWN, for DTI/PRT initialization.
    NOTE:The following table shows the 
    relationship between CMAA 
    YY=01 and YY=02.
    (1)
    (2)
    
    (1)
    (2)
    
    (1)
    (2)
    
    (1)
    (2)YY=00 Data Mode
    04-15, 20-31: AP No. assigned by 
    CM05
    0: Based on AT&T Spec.
    YY=01 Frame Configuration
    04-15, 20-31: AP No. assigned by 
    CM05
    0 : 12-Multi Frame
    1 : 24-Multi Frame
    YY=02 Zero Code Suppression
    04-15, 20-31: AP No. assigned by 
    CM05
    0 : Available
    1 : Not available
    YY=03
    04-15, 20-31: AP No. assigned by 
    CM05
    7 : Associated Channel 
    Interoffice Signaling
    Assign a trunk route number to each ISDN 
    trunk used for voice channel and also to 
    signaling channel. The DTI route must be 
    separated from any analog trunk route.
    (1)
    (2)YY=00
    000-255: Trunk No. assigned by CM07 
    YY=01
    00-63: Trunk Route No.
    Assign the trunk route data to each ISDN 
    incoming trunk used for Voice channel 
    only. 
    
    
    
    (1)
    (2)YY=02 Day Mode
    YY=03 Night Mode
    YY=40 Mode A
    YY=41 Mode B
    000-255: Trunk No. assigned by CM07 
    YY=01
    02: Trunk Line Appearance
    03: Trunk Line Appearance + TAS
    04: Direct-In Termination
    09: Automated Attendant
    14: Termination to Attendant console
    16: Remote Access to System (DISA)
    18: ISDN Indial
    CMAA
    A
    CM30
    B
    DTI INITIAL
     [ ]: Indicates 2nd data
    CMAA YY=01 
    (FRAME CON-
    FIGURATION)CMAA YY=02 
    (ZERO CODE 
    SUPPRES-
    SION)SIGNALING
    24-Multi Frame 
    [1]
    B8ZS
    12-Multi Frame 
    [0]Not available [1] Transparent
    Available [0] B7 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    ISDN-PRI Programming
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 67
    DESCRIPTION DATA
    Assign Circuit Identification Code (CIC) 
    number to each ISDN trunk used for voice 
    channel only.
    NOTE:CIC No. must not be assigned to 
    the trunk No. of D channel: TS16 
    (30DTI) or TS23 (24DTI/PRT).
    (1)
    (2)YY=07
    000-255: Trunk No. assigned by CM07 
    YY=01
    000-029: CIC No.
    EXAMPLE OF 30DTI
    B channel trunk No.: D100-D114, D116-
    D130
    D channel trunk No.: D115
    (1) 100-114, 116-130
    (2) 000-014, 015-029
    EXAMPLE OF 24DTI/PRT
    B channel trunk No.: D100-D122
    D channel trunk No.: D123
    (1) 100-122
    (2) 000-022
    Assign trunk route data to the route 
    number assigned by CM30 YY=00.
    (1)
    (2)
    (1)
    (2)YY=00 Kind of Trunk Route
    00-63: B channel Trunk Route No.
    00: ISDN Trunk
    00-63: D channel Trunk Route No.
    15 : Not used
    
    (1)
    (2)YY=02 Call Direction
    00-63: B channel Trunk Route No.
    3 : Bothway Trunk  
    NOTE 1
    
    (1)
    (2)
    (1)
    (2)YY=04 Answer Signal from distant 
    office
    00-63: B channel Trunk Route No.
    2: Answer signal arrives (ISDN Trunk) 
    00-63: D channel Trunk Route No.
    7 : Not used 
    CM30
    B
    CM35
    C 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 68  ND-70919 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    ISDN-PRI Programming
    DESCRIPTION DATA
    
    (1)
    (2)YY=05 
    Release Signal from distant office
    00-63: B channel/D channel Trunk 
    Route No.
    1 : Release signal arrives 
    NOTE 2
    
    (1)
    (2)
    (1)
    (2)YY=09 Incoming Connection Signaling
    00-63: B channel Trunk Route No.
    08: ISDN
    00-63: D channel Trunk Route No.
    15 : Not used
    
    (1)
    (2)YY=11 Toll Restriction
    00-63: B channel Trunk Route No.
    0 : Provided  
    NOTE 1
    3 : Not provided
    
    (1)
    (2)YY=12 
    Number of digits to be received on DID
    00-63: B channel Trunk Route No.
    0 : 1 digit
    1 : 2 digits
    2 : 3 digits
    3 : 4 digits
    NOTE:If CM35 YYY=143 is set to “1” 
    for Event Based CCIS, the 
    number of digits received on 
    DID must be assigned.
    
    (1)
    (2)YY=14 SMDR for outgoing call
    00-63: B channel Trunk Route No. 
    0 : Not provided
    1 : Provided  
    NOTE 1
    
    (1)
    (2)YY=15 Kind of Call Termination Indica-
    tor Key/Lamp on ATT
    00-63: B channel Trunk Route No.
    00-07: C.O. Incoming 0-7  
    NOTE 1
    CM35
    C
    D 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    ISDN-PRI Programming
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 69
    DESCRIPTION DATA
    NOTE 1:This data should be assigned to 
    the B channel trunk route.  For 
    D channel trunk route, no data 
    setting is required.
    NOTE 2:This data should be assigned to 
    both B channel trunk route and 
    D channel trunk route.
    (1)
    (2)YY=16 
    Hooking Signal Sending to outside
    00-63: B channel Trunk Route No.
    0: Not sending  
    NOTE 1
    
    (1)
    (2)YY=18 Digit conversion on DID call
    00-63: B channel Trunk Route No.
    0 : Provided
    1 : Not provided
    
    (1)
    (2)YY=19 
    00-63: B channel Trunk Route No. 
    0-3 : Programmable PAD 
    (See CM42)
    4-7 : Fixed PAD   
    NOTE 1
    NOTE:For details of PAD data, refer to 
    Command Manual.
    
    (1)
    (2)YY=28 Outgoing Trunk Queuing
    00-63: B channel Trunk Route No.
    0: Restricted  
    NOTE 1
    
    (1)
    (2)YY=39 Trunk release by detection of 
    reversal of tip and ring
    00-63: B channel Trunk Route No.
    1 : To release  
    NOTE 1
    
    (1)
    (2)YY=89 CRC error check
    00-63: B channel Trunk Route No.
    0: Provided  
    NOTE 1
    
    (1)
    (2)YY=90 Assignment of DTI route for 
    ISDN
    00-63: B channel/D channel Trunk 
    Route No.
    3: ISDN-Primary Rate Interface
    NOTE 2
    CM35
    D
    E 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Isdn System Manual