NEAX2000 IVS2 ISDN System ManualPage 170 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24PRTA (PRT) MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW0 (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO0 input on MP card. OFFSource clock signal from network is not sent to the PLO0 input on MP card. 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO1 input on MP card. OFFSource clock signal from network is not sent to the PLO1 input on MP card. 3ONRemote loop-back For normal operation 4ONLocal loop-back (AIS send) For normal operation 5Set equalizer according to the cable length between the PBX and the MDF. OFF 6 OFF 7 OFF 8 Not used (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK ON DOWN OFF ON 5 6 7 8 1 2 3 4 OFF OFF ON OFF 80-120 m (262.5-394 ft.) SW0-5 SW0-6 SW0-7CABLE LENGTH ON ON0-40 m (0-131.2 ft.) 40-80 m (131.2-262.5 ft.) 120-160 m (394-525 ft.) 160-200 m (525-656 ft.) Signal is not sent ON ON ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24PRTA (PRT) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 171 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Piano Key SW) NOTE 41 Not used 2 Not used 3 Not used 4ON AP No. 04-15 OFF AP No. 20-31 SW2 (DIP SW) 1 Always set to OFF. 2[Nor th America only for AT&T] ONDeletion of Area Code on International Outgoing call OFFNo deletion of Area Code on International Outgoing call [Australia/Other countries] Always set to OFF. 3 Always set to OFF. 4 Always set to OFF. 5 Always set to OFF. 6 Always set to OFF. 7 Always set to OFF. 8 Always set to OFF. (Continued) 4 3 2 1 OFF ON OFF OFF OFF 1 23 45 67 8OFF OFF OFF OFF OFF OFF OFF OFF OFF
NEAX2000 IVS2 ISDN System ManualPage 172 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24PRTA (PRT) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. JPR0 (Jumper Pin) UPNeutral grounding on the receiving line is provided. Neutral grounding on the receiving line is not provided. JPR1 (Jumper Pin) Line impedance: 100 ohms Left Line impedance: 110 ohms JPS (Jumper Pin) UPNeutral grounding on the transmitting line is provided. Neutral grounding on the transmitting line is not provided. MAS (Jumper Pin) UP Clock Source Clock Receiver AISS (Jumper Pin) AIS signal is sent out when make- busy or power on. DOWNAIS signal is not sent out when make-busy or power on. (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK DOWN Right DOWN DOWN UP
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24PRTA (PRT) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 173 NOTE 3:Set SW0-1 and SW0-2 as follows: NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the PRT cards mounted in PIM0 to OFF. NOTE 5:Mount the PRT card which receives a source clock signal into PIM 0. CONDITIONSPRT0 PRT1 PRT2 PRT3 PRT4 REMARKS SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2 When one PRT is provided.ONOFF––––––––MP card will receive the clock signal from PRT0 at its PLO0 input. When more than one PRT is provided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFMP card will receive the clock signal from PRT0 at its PLO0 input, under normal conditions. If a clock failure occurs with PRT0, MP card automatically switches to the PLO1 input which gets clock from PRT1.
NEAX2000 IVS2 ISDN System ManualPage 174 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC00 (CCH) PN-SC00 (CCH) Locations of Lamps, Switches and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LC Green Remains lit when communications are normally ongoing with the common signalling channel data links connected LPB Green Remains lit when a loop-back test is in progress RS SENSE RUN MB SW0 LC LPB SW1 TO M O D E M ( FOR ANALOG INTERFACE)
CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC00 (CCH) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 175 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation SW0 (Piano Key SW)1ON Loop-back test For normal operation 2ON Analog interface OFF Digital interface 3ONRS-232C RTS signal (to MODEM) ON NOTE 3 OFFRS-232C RTS signal (to MODEM) OFF 4ON AP No. 04-15 OFF AP No. 20-31 (Continued) F 4AP No.SW0-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW0-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN 4 3 2 1 OFF ON OFF
NEAX2000 IVS2 ISDN System ManualPage 176 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC00 (CCH) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. NOTE 3:This setting is available when SW0-2 is set to ON (Analog Interface). NOTE 4:The following two kind of rate adaptation methods are available in 48 Kbps data transmission. The rate adaptation method must be set to match the rate adaptation of master office. SW1(DIP SW) 1ON Common channel signalling data transmission speed (For Digital Interface) Common channel signalling data transmission speed (For Analog Interface) Set switches (SW1-1 - SW1-5) to OFF. OFF 2ON OFF 3ON OFF 4ON OFF 5ON OFF 6ON A-law OFFµ-law 7 Always set to OFF. 8 Always set to OFF. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON TRANSMISSION SPEEDSW 1-1SW 1-2SW 1-3SW 1-4SW 1-5 48 Kbps NOTE 4ON ON OFF OFF ON 48 Kbps NOTE 4ON ON ON OFF ON 56 Kbps ON ON OFF ON ON 64 Kbps ON ON ON ON ON OFF OFF 11 48 Kbps Data SW1-3: OFF 11 48 Kbps SW1-3: ON Data
CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC01 (DCH) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 177 PN-SC01 (DCH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LC Green Remains lit when communications are normally ongoing with the D channel data links connected LPB Green Not used SENSE RUN MB SW0 LC LPB SW1
NEAX2000 IVS2 ISDN System ManualPage 178 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC01 (DCH) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation SW0 (Piano Key SW)1 Always set to OFF. 2 Always set to OFF. 3 Always set to OFF. 4ON AP No. 04-15 OFF AP No. 20-31 (Continued) F 4 AP No.SW0-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW0-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN 4 3 2 1 OFF ON OFF OFF OFF
CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC01 (DCH) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 179 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. SW1 (DIP SW) 1 Always set to OFF. 2 Always set to OFF. 3 Always set to OFF. 4 Always set to OFF. 5 Always set to OFF. 6 Always set to OFF. 7 Always set to OFF. 8 Always set to OFF. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON OFF OFF OFF OFF OFF OFF OFF OFF