Home > NEC > Communications System > NEC Neax 2000 Ivs2 Isdn System Manual

NEC Neax 2000 Ivs2 Isdn System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Isdn System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 NEAX2000 IVS2 ISDN System ManualPage 170  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24PRTA (PRT)
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO0 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO0 input on MP 
    card. 
    2 
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO1 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO1 input on MP 
    card. 
    3ONRemote loop-back
    For normal operation
    4ONLocal loop-back (AIS send)
    For normal operation
    5Set equalizer according to the cable 
    length between the PBX and the 
    MDF. OFF
    6
    OFF
    7
    OFF
    8 Not used
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    ON
    DOWN
    OFF
    ON
    5 6 7 8
    1 2 3 4
    OFF
    OFF
    ON
    OFF
    80-120 m (262.5-394 ft.)
    SW0-5 SW0-6 SW0-7CABLE LENGTH
    ON ON0-40 m (0-131.2  ft.)
    40-80 m (131.2-262.5 ft.)
    120-160 m (394-525 ft.)
    160-200 m (525-656 ft.)
    Signal is not sent ON ON ON
    ON ON OFF
    OFF ON OFF
    ON OFF ON
    OFF OFF OFF
    ON
    ON
    OFF 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24PRTA (PRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 171
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW1
    (Piano Key SW)
    NOTE 41 Not used
    2 Not used
    3 Not used
    4ON AP No. 04-15
    OFF AP No. 20-31
    SW2 (DIP SW) 1
    Always set to OFF.
    2[Nor th America only for AT&T]
    ONDeletion of Area Code on 
    International Outgoing call
    OFFNo deletion of Area Code on 
    International Outgoing call
    [Australia/Other countries]
    Always set to OFF.
    3 Always set to OFF.
    4 Always set to OFF.
    5 Always set to OFF.
    6 Always set to OFF.
    7 Always set to OFF.
    8 Always set to OFF.
    (Continued)
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    1
    23
    45
    67
    8OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 172  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24PRTA (PRT)
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card. JPR0 (Jumper Pin)
    UPNeutral grounding on the receiving 
    line is provided.
    Neutral grounding on the receiving 
    line is not provided.
    JPR1 (Jumper Pin)
    Line impedance: 100 ohms
    Left Line impedance: 110 ohms
    JPS (Jumper Pin)
    UPNeutral grounding on the 
    transmitting line is provided.
    Neutral grounding on the 
    transmitting line is not provided.
    MAS (Jumper Pin)
    UP Clock Source
    Clock Receiver
    AISS (Jumper Pin)
    AIS signal is sent out when make-
    busy or power on.
    DOWNAIS signal is not sent out when 
    make-busy or power on.
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    DOWN
    Right
    DOWN
    DOWN
    UP 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24PRTA (PRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 173
    NOTE 3:Set SW0-1 and SW0-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the PRT cards
    mounted in PIM0 to OFF.
    NOTE 5:Mount the PRT card which receives a source clock signal into PIM 0.
    CONDITIONSPRT0 PRT1 PRT2 PRT3 PRT4
    REMARKS
    SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2
    When one PRT 
    is provided.ONOFF––––––––MP card will receive the 
    clock signal from PRT0 
    at its PLO0 input.
    When more 
    than one PRT 
    is provided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFMP card will receive the 
    clock signal from PRT0 
    at its PLO0 input, under 
    normal conditions.
    If a clock failure occurs 
    with PRT0, MP card 
    automatically switches 
    to the PLO1 input 
    which gets clock from 
    PRT1. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 174  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-SC00 (CCH)
    PN-SC00 (CCH)
    Locations of Lamps, Switches and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    LC Green Remains lit when communications are normally ongoing with the 
    common signalling channel data links connected
    LPB Green Remains lit when a loop-back test is in progress
    RS
    SENSE
    RUN
    MB
    SW0
    LC
    LPB SW1
    TO  M O D E M  
    ( FOR ANALOG INTERFACE) 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-SC00 (CCH)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 175
    Switch Settings
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)1ON Loop-back test
    For normal operation
    2ON Analog interface
    OFF Digital interface
    3ONRS-232C RTS signal (to MODEM) 
    ON  NOTE 3
    OFFRS-232C RTS signal (to MODEM) 
    OFF
    4ON AP No. 04-15
    OFF AP No. 20-31
    (Continued)
    F
    4AP No.SW0-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW0-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 176  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-SC00 (CCH)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    NOTE 3:This setting is available when SW0-2 is set to ON (Analog Interface).
    NOTE 4:The following two kind of rate adaptation methods are available in 48 Kbps data
    transmission. The rate adaptation method must be set to match the rate adaptation of
    master office. SW1(DIP SW)
    1ON Common channel signalling data 
    transmission speed (For Digital 
    Interface)
     Common channel signalling data 
    transmission speed (For Analog 
    Interface)
    Set switches (SW1-1 - SW1-5) to 
    OFF. OFF
    2ON
    OFF
    3ON
    OFF
    4ON
    OFF
    5ON
    OFF
    6ON A-law
    OFFµ-law
    7 Always set to OFF.
    8 Always set to OFF.
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ON
    TRANSMISSION
    SPEEDSW
    1-1SW
    1-2SW 
    1-3SW 
    1-4SW 
    1-5
    48 Kbps 
    NOTE 4ON ON OFF OFF ON
    48 Kbps 
    NOTE 4ON ON ON OFF ON
    56 Kbps ON ON OFF ON ON
    64 Kbps ON ON ON ON ON
    OFF
    OFF
    11
    48 Kbps
    Data   SW1-3: OFF
    11
    48 Kbps
      SW1-3: ON
    Data 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-SC01 (DCH)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 177
    PN-SC01 (DCH)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    LC Green Remains lit when communications are normally ongoing with the 
    D channel data links connected
    LPB Green Not used
    SENSE
    RUN
    MB
    SW0
    LC 
    LPB SW1 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 178  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-SC01 (DCH)
    Switch Settings
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)1 Always set to OFF.
    2 Always set to OFF.
    3 Always set to OFF.
    4ON AP No. 04-15
    OFF AP No. 20-31
    (Continued)
    F
    4
    AP No.SW0-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW0-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-SC01 (DCH)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 179
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card. SW1 (DIP SW)
    1 Always set to OFF.
    2 Always set to OFF.
    3 Always set to OFF.
    4 Always set to OFF.
    5 Always set to OFF.
    6 Always set to OFF.
    7 Always set to OFF.
    8 Always set to OFF.
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ON
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Isdn System Manual