    							 NEAX2000 IVS2 ISDN System ManualPage 160  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    (Continued)
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW1
    (Piano Key SW)
    NOTE 41 Not used
    2 Not used
    3 Not used
    4ON AP No. 04-15
    OFF AP No. 20-31
    JPR0 (Jumper Pin)
    UPNeutral grounding on the receiving 
    line is provided.
    Neutral grounding on the receiving 
    line is not provided.
    JPR1 (Jumper Pin)
    Line impedance: 100 ohms
    LeftLine impedance: 110 ohms
    JPS (Jumper Pin)
    UPNeutral grounding on the 
    transmitting line is provided.
    Neutral grounding on the 
    transmitting line is not provided.
    MAS (Jumper Pin)
    UPClock Source
    Clock Receiver
    AISS (Jumper Pin)
    AIS signal is sent out when make-
    busy or power on.
    DOWNAIS signal is not sent out when 
    make-busy or power on.
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    DOWN
    Right
    DOWN
    DOWN
    UP 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 161
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    NOTE 3:Set SW0-1 and SW0-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards
    mounted in PIM0 to OFF.
    NOTE 5:Mount the DTI card which receives a source clock signal into PIM0.
    CONDITIONSDTI0 DTI1 DTI2 DTI3 DTI4
    REMARKS
    SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2
    When one DTI is 
    provided.ONOFF––––––––MP card will receive the 
    clock signal from DTI0 at its 
    PLO0 input.
    When more than 
    one DTI is 
    provided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFMP card will receive the 
    clock signal from DTI0 at its 
    PLO0 input, under normal 
    conditions.
    If a clock failure occurs with 
    DTI0, MP card automatically 
    switches to the PLO1 input 
    which gets clock from DTI1. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 162  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    PN-30DTC-A (DTI)
    Locations of Lamps, Switches, and Connectors
    SENSE
    RUN
    MB
    SW
    PCM 
    FRM 
    MFRM 
    RMT 
    MRMT 
    AIS 
    BL  
     
     
     
     
    JP JPSJPR 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 163
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM when this card is normally operating
    PCM Red Remains lit when detecting PCM signal loss
    FRM Red Remains lit when detecting Frame Alignment signal loss
    MFRM Red Remains lit when detecting Multi-Frame Alignment signal loss on 
    time slot 16
    RMT Red Remains lit when receiving the alarm from a distant office 
    because Frame Alignment signal loss has been detected at the 
    distant office
    MRMT Red Remains lit when receiving the alarm from a distant office 
    because Multi-Frame Alignment signal loss has been detected at 
    the distant office
    AIS Red Remains lit when indicating that the pattern of consecutive “1” is 
    being received. The distant office transmits this signal for a loop-
    back test distant.
    BL Red B channel status
    ON  : More than 10 channels are busy.
    OFF : All channels are idle.
    Flash (60 IPM) : Only one channel is busy.
    Flash (120 IPM) : 2 to 10 channels are busy. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 164  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    Switch Settings
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS 
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2
    UP
    For make-busy
    For normal operation
    (Continued)
    F
    4
    AP No.SW-8: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW-8: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 165
    SW
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO0 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO0 input on MP 
    card 
    2
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO1 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO1 input on MP 
    card. 
    3ON Remote loop-back
    For normal operation
    4ON
    Local loop-back (AIS send)
    For normal operation
    5ONTransmission line cable: 
    Coaxial cable (75 ohms)
    Transmission line cable: 
    Twisted-pair cable (120 ohms)
    6
    Always set to OFF
    7
    8ON AP No. 04-15
    OFF AP No. 20-31
    (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    OFF
    ON
    5 6 7 8
    1 2 3
    4
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 166  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card. JPS
    (Jumper Pin)
    Balanced transmission
    (For twisted-pair cable)
    DOWNTA is grounded on the transmission 
    line (For coaxial cable)
    JPR
    (Jumper Pin)
    Balanced transmission
    (For twisted-pair cable)
    DOWNRA is grounded on the transmission
    line (For coaxial cable)
    JP
    (Jumper Pin)
    RIGHTLine impedance: 75 ohms
    (For coaxial cable)
    Line impedance: 120 ohms 
    (For twisted-pair cable)
    (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    UP
    UP
    LEFT 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 167
    NOTE 3:Set the SW-1 and SW-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW-1 and SW-2 on all the DTI cards
    mounted in PIM0 to OFF.
    NOTE 5:Mount the DTI card which receives a source clock signal into PIM0. CONDITIONSDTI0 DTI1 DTI2 DTI3
    REMARKS
    SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2
    When one DTI is 
    provided.ON OFF – – – – – –MP card will receive the clock 
    signal from DTI0 at its PLO0 
    input.
    When more than 
    one DTI is 
    provided.ON OFF OFF ON OFF OFF OFF OFFMP card will receive the clock 
    signal from DTI0 at its PLO0 
    input, under normal condi-
    tions.
    If a clock failure occurs with 
    DTI0, MP card automatically 
    switches to the PLO1 input 
    which gets from DTI1. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 168  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24PRTA (PRT)
    PN-24PRTA (PRT)
    Locations of Lamps, Switches, and Connectors
    SENSE
    RUN
    MB
    SW2
    LC 
    LPB 
    CRC 
    PCM 
    FRM 
    RMT 
    AIS 
    BL 
       
     
     
     
     
     
      SW1
    SW0
    JRR1
    AISS MAS
    JPR0
    JPS 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24PRTA (PRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 169
    Lamp Indications
    Switch Settings
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    LC Green Remains lit when communications are normally ongoing with the 
    D channel data links connected
    LPB – Not used
    CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) 
    errors
    PCM Red Remains lit when detecting PCM signal loss
    FRM Red Remains lit when detecting Frame Alignment signal loss
    RMT Red Remains lit when receiving Frame Alignment signal loss alarm 
    from a distant office
    AIS Red Remains lit when a pattern of consecutive “1” is received. 
    The distant office transmits this signal for a loop-back test.
    BL Red B channel status
    ON : More than 10 channels are busy.
    OFF : All channels are idle.
    Flash (60 IPM) : Only one channel is busy.
    Flash (120 IPM) : 2 through 10 channels are busy.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    (Continued)
    F
    4
    AP No.SW1-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF 
    						