    							 NEAX2000 IVS2 ISDN System ManualPage 150  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-BRTA (BRT)
    NOTE 3:Set the SW0-2 and SW0-3 as follows:
    NOTE 4:When the system is a clock source office, set the SW0-2 and SW0-3 on all the BRT
    cards mounted in PIM0 to OFF.
    NOTE 5:Mount the BRT card which receives a source clock signals into PIM0. CONDITIONSBRT0 BRT1 BRT2 ---- BRT11
    REMARKS
    SW
    0-2SW
    0-3SW
    0-2SW
    0-3SW
    0-2SW
    0-3----SW
    0-2SW
    0-3
    When one 
    BRT is 
    provided.ON ON
    MP card will receive the 
    clock signal from BRT0 at 
    its PLO0 input.
    When more 
    than one BRT 
    is provided.ON ON ON OFF OFF ON ---- OFF ONMP card will receive the 
    clock signal from BRT0 at 
    its PLO0 input, under nor-
    mal conditions.
    If a clock failure occurs with 
    BRT0, MP card switches to 
    the PLO1 input which gets 
    clock from BRT1. 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-2BRTC (BRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 151
    PN-2BRTC (BRT)
    Locations of Lamps, Switches, and Connectors
    SENSE
    RUN
    MB
    B21 
    B11 
    D1 
    ALM1 
    B20 
    B10 
    D0 
    ALM0
    SW0 SW11
    SW10 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 152  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-2BRTC (BRT)
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    B21 Red No.1 Circuit B2 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    B11 Red B1 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    D1 Green D channel status
    ON: Busy
    OFF: Idle
    ALM1 Red Transmission line fault status
    ON: Line fault
    OFF: Normal operation
    B20 Red No.0 Circuit B2 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    B10 Red B1 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    D0 Green D channel status
    ON: Busy
    OFF: Idle
    ALM0 Red Transmission line fault status
    ON: Line fault
    OFF: Normal operation 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-2BRTC (BRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 153
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    SW0, SW10
    (DIP SW)
    1For terminating the transmitting side 
    of channels B1 and B2 with 100 
    ohms
    OFFTo remove the terminating resistor 
    on the transmitting side of channels 
    B1 and B2
    2For terminating the receiving side of 
    channels B1 and B2 with 100 ohms
    OFFTo remove the terminating resistor 
    on the receiving side of channels B1 
    and B2
    (Continued)
    F
    4AP No.SW11-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW11-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN
    1
    2ON
    ON
    ON 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 154  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-2BRTC (BRT)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card. SW11 (DIP SW)
    1For normal operation
    OFF Not used
    2
    NOTE 3
    NOTE 4ONOutput clock signals according to
    the switch setting of SW11-3
    OFF Do not output clock signals.
    3
    NOTE 3
    NOTE 4ON Output clock signals to PLO0 of MP
    OFF Output clock signals to PLO1 of MP
    4ON AP No. 04-15
    OFF AP No. 20-31
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    4ON
    ON 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-2BRTC (BRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 155
    NOTE 3:The system can supply clock signals from two clock supply routes.
    In normal condition, the system synchronizes to the clock signals supplied on the PLO0
    of MP card via the Back Wiring Board, and if the clock signals fail, the clock supply
    route takes over to PLO1 automatically. Set SW11-2 and SW11-3 as follows:
    NOTE 4:When the system is a clock source office, set the SW11-2 and SW11-3 on all the BRT
    cards mounted in PIM0 to OFF.
    NOTE 5:Mount the BRT card which receives a source clock signals into PIM0. CONDITIONSBRT0 BRT1 BRT2 ---- BRT11
    REMARKS
    SW
    11-2SW
    11-3SW
    11-2SW
    11-3SW
    11-2SW
    11-3----SW
    11-2SW
    11-3
    When one BRT 
    is provided.ON ON
    MP card will receive the clock 
    signal from No.0 circuit of 
    BRT0 at its PLO0 input.
    If a clock failure occurs with 
    No. 0 circuit, MP card 
    switches to No. 1 circuit of 
    BRT0.
    When more 
    than one BRT 
    is provided.ON ON ON OFF OFF ON ---- OFF ONMP card will receive the clock 
    signal from BRT0 at its PLO0 
    input, under normal condi-
    tions.
    If a clock failure occurs with 
    both No. 0 and No. 1 circuits 
    of BRT0, MP card switches to 
    the PLO1 input which gets 
    clock from BRT1. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 156  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    PN-24DTA-C (DTI)
    Locations of Lamps, Switches, and Connectors
    SENSE
    RUN
    MB
     
     
    CRC 
    PCM 
    FRM 
    RMT 
    AIS 
    BL 
       
     
     
     
     
     
      SW1
    SW0
    JRR1
    AISS MAS
    JPR0
    JPS 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 157
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) 
    errors
    PCM Red Remains lit when detecting PCM signal loss
    FRM Red Remains lit when detecting Frame Alignment signal loss
    RMT Red Remains lit when receiving Frame Alignment signal loss alarm 
    from a distant office
    AIS Red Remains lit when a pattern of consecutive “1” is received. The 
    distant office transmits this signal for a loop-back test.
    BL Red B channel status
    ON : More than 10 channels are busy.
    OFF : All channels are idle.
    Flash (60 IPM) : Only one channel is busy.
    Flash (120 IPM) : 2 through 10 channels are busy. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 158  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    (Continued)
    F
    4
    AP No.SW1-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 159
    SW0
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO0 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO0 input on MP 
    card. 
    2 
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO1 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO1 input on MP 
    card. 
    3ONRemote loop-back
    For normal operation
    4ONLocal loop-back (AIS send)
    For normal operation
    5Set equalizer according to the cable 
    length between the PBX and the 
    MDF. OFF
    6
    OFF
    7
    OFF
    8 Not used
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    OFF
    ON
    5 6 7 8
    1 2
    3 4
    OFF
    OFF
    ON
    OFF
    80-120 m (262.5-394 ft.)
    SW0-5 SW0-6 SW0-7CABLE LENGTH
    ON ON0-40 m (0-131.2 ft.)
    40-80 m (131.2-262.5 ft.)
    120-160 m (394-525 ft.)
    160-200 m (525-656 ft.)
    Signal is not sent ON ON ON
    ON ON OFF
    OFF ON OFF
    ON OFF ON
    OFF OFF OFF
    ON
    ON
    OFF 
    						
    All NEC manuals Comments (0)