NEAX2000 IVS2 ISDN System ManualPage 150 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-BRTA (BRT) NOTE 3:Set the SW0-2 and SW0-3 as follows: NOTE 4:When the system is a clock source office, set the SW0-2 and SW0-3 on all the BRT cards mounted in PIM0 to OFF. NOTE 5:Mount the BRT card which receives a source clock signals into PIM0. CONDITIONSBRT0 BRT1 BRT2 ---- BRT11 REMARKS SW 0-2SW 0-3SW 0-2SW 0-3SW 0-2SW 0-3----SW 0-2SW 0-3 When one BRT is provided.ON ON MP card will receive the clock signal from BRT0 at its PLO0 input. When more than one BRT is provided.ON ON ON OFF OFF ON ---- OFF ONMP card will receive the clock signal from BRT0 at its PLO0 input, under nor- mal conditions. If a clock failure occurs with BRT0, MP card switches to the PLO1 input which gets clock from BRT1.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-2BRTC (BRT) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 151 PN-2BRTC (BRT) Locations of Lamps, Switches, and Connectors SENSE RUN MB B21 B11 D1 ALM1 B20 B10 D0 ALM0 SW0 SW11 SW10
NEAX2000 IVS2 ISDN System ManualPage 152 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2BRTC (BRT) Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally B21 Red No.1 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B11 Red B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D1 Green D channel status ON: Busy OFF: Idle ALM1 Red Transmission line fault status ON: Line fault OFF: Normal operation B20 Red No.0 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B10 Red B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D0 Green D channel status ON: Busy OFF: Idle ALM0 Red Transmission line fault status ON: Line fault OFF: Normal operation
CHAPTER 4 CIRCUIT CARD INFORMATION PN-2BRTC (BRT) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 153 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation SW0, SW10 (DIP SW) 1For terminating the transmitting side of channels B1 and B2 with 100 ohms OFFTo remove the terminating resistor on the transmitting side of channels B1 and B2 2For terminating the receiving side of channels B1 and B2 with 100 ohms OFFTo remove the terminating resistor on the receiving side of channels B1 and B2 (Continued) F 4AP No.SW11-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW11-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN 1 2ON ON ON
NEAX2000 IVS2 ISDN System ManualPage 154 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2BRTC (BRT) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. SW11 (DIP SW) 1For normal operation OFF Not used 2 NOTE 3 NOTE 4ONOutput clock signals according to the switch setting of SW11-3 OFF Do not output clock signals. 3 NOTE 3 NOTE 4ON Output clock signals to PLO0 of MP OFF Output clock signals to PLO1 of MP 4ON AP No. 04-15 OFF AP No. 20-31 (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 4ON ON
CHAPTER 4 CIRCUIT CARD INFORMATION PN-2BRTC (BRT) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 155 NOTE 3:The system can supply clock signals from two clock supply routes. In normal condition, the system synchronizes to the clock signals supplied on the PLO0 of MP card via the Back Wiring Board, and if the clock signals fail, the clock supply route takes over to PLO1 automatically. Set SW11-2 and SW11-3 as follows: NOTE 4:When the system is a clock source office, set the SW11-2 and SW11-3 on all the BRT cards mounted in PIM0 to OFF. NOTE 5:Mount the BRT card which receives a source clock signals into PIM0. CONDITIONSBRT0 BRT1 BRT2 ---- BRT11 REMARKS SW 11-2SW 11-3SW 11-2SW 11-3SW 11-2SW 11-3----SW 11-2SW 11-3 When one BRT is provided.ON ON MP card will receive the clock signal from No.0 circuit of BRT0 at its PLO0 input. If a clock failure occurs with No. 0 circuit, MP card switches to No. 1 circuit of BRT0. When more than one BRT is provided.ON ON ON OFF OFF ON ---- OFF ONMP card will receive the clock signal from BRT0 at its PLO0 input, under normal condi- tions. If a clock failure occurs with both No. 0 and No. 1 circuits of BRT0, MP card switches to the PLO1 input which gets clock from BRT1.
NEAX2000 IVS2 ISDN System ManualPage 156 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) PN-24DTA-C (DTI) Locations of Lamps, Switches, and Connectors SENSE RUN MB CRC PCM FRM RMT AIS BL SW1 SW0 JRR1 AISS MAS JPR0 JPS
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 157 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors PCM Red Remains lit when detecting PCM signal loss FRM Red Remains lit when detecting Frame Alignment signal loss RMT Red Remains lit when receiving Frame Alignment signal loss alarm from a distant office AIS Red Remains lit when a pattern of consecutive “1” is received. The distant office transmits this signal for a loop-back test. BL Red B channel status ON : More than 10 channels are busy. OFF : All channels are idle. Flash (60 IPM) : Only one channel is busy. Flash (120 IPM) : 2 through 10 channels are busy.
NEAX2000 IVS2 ISDN System ManualPage 158 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3 Not used 4-F Set the switch to match the AP Number (04-31) to be set by CM05. MB (Toggle SW) NOTE 2 UP For make-busy For normal operation (Continued) F 4 AP No.SW1-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW1-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 159 SW0 (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO0 input on MP card. OFFSource clock signal from network is not sent to the PLO0 input on MP card. 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO1 input on MP card. OFFSource clock signal from network is not sent to the PLO1 input on MP card. 3ONRemote loop-back For normal operation 4ONLocal loop-back (AIS send) For normal operation 5Set equalizer according to the cable length between the PBX and the MDF. OFF 6 OFF 7 OFF 8 Not used (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK OFF ON 5 6 7 8 1 2 3 4 OFF OFF ON OFF 80-120 m (262.5-394 ft.) SW0-5 SW0-6 SW0-7CABLE LENGTH ON ON0-40 m (0-131.2 ft.) 40-80 m (131.2-262.5 ft.) 120-160 m (394-525 ft.) 160-200 m (525-656 ft.) Signal is not sent ON ON ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF