NEAX2000 IVS2 ISDN System ManualPage 180 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC03 (ICH) PN-SC03 (ICH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally DOPE7 Green Remains lit when No. 7 circuit D channel link is connected DOPE6 Green Remains lit when No. 6 circuit D channel link is connected DOPE5 Green Remains lit when No. 5 circuit D channel link is connected DOPE4 Green Remains lit when No. 4 circuit D channel link is connected DOPE3 Green Remains lit when No. 3 circuit D channel link is connected DOPE2 Green Remains lit when No. 2 circuit D channel link is connected DOPE1 Green Remains lit when No. 1 circuit D channel link is connected DOPE0 Green Remains lit when No. 0 circuit D channel link is connected SENSE RUN MB DOPE7 DOPE6 DOPE5 DOPE4 DOPE3 DOPE2 DOPE1 DOPE0
CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC03 (ICH) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 181 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-15) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation F 4AP No.04 05 06 07 08 09 10 11 12 13 14 15 SW No.456789ABCDEF ON DOWN
NEAX2000 IVS2 ISDN System ManualPage 182 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M542 (CONN) PZ-M542 (CONN) Locations of Lamps, Switches, and Connectors Lamp Indications This card has no lamps. JP2 RCV21 FOR No.2 CIRCUIT LT CJP1LTTO LTC CONNECTOR ON BWB IN PIM TO CHAMP CONNECTOR (MDF) JP0 TRS21 TRS01 FOR No.0 CIRCUIT COAXIAL CONNECTORRCV01 RCV11 FOR No.1 CIRCUITTRS11
CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M542 (CONN) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 183 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0For coaxial connectors (No. 0 circuit) LEFTFor champ connector (LT connector) (No. 0 circuit) JP1 For coaxial connectors (No. 1 circuit) LEFTFor champ connector (LT connector) (No. 1 circuit) JP2 For coaxial connectors (No. 2 circuit) LEFTFor champ connector (LT connector) (No. 2 circuit) RIGHT RIGHT RIGHT
NEAX2000 IVS2 ISDN System ManualPage 184 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M557 (CONN) PZ-M557 (CONN) Locations of Lamps, Switches, and Connectors Lamp Indications This card has no lamps. JP2 RCV20 FOR No.2 CIRCUIT LT CJP1LTTO LTC CONNECTOR ON BWB IN PIM TO CHAMP CONNECTOR (MDF) JP0 TRS20 TRS00 FOR No.0 CIRCUIT COAXIAL CONNECTORRCV00RCV10 FOR No.1 CIRCUIT TRS10
CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M557 (CONN) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 185 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0For coaxial connectors (No. 0 circuit) LEFTFor champ connector (LT connector) (No. 0 circuit) JP1 For coaxial connectors (No. 1 circuit) LEFTFor champ connector (LT connector) (No. 1 circuit) JP2 For coaxial connectors (No. 2 circuit) LEFTFor champ connector (LT connector) (No. 2 circuit) RIGHT RIGHT RIGHT
NEAX2000 IVS2 ISDN System ManualPage 186 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2ILCA (ILC) PN-2ILCA (ILC) Locations of Lamps, Switches, and Connectors PA L 1AC T1 LPB1 B21 B11 PA L 0 AC T0 LPB0 B20 B10 SW1 SW0
CHAPTER 4 CIRCUIT CARD INFORMATION PN-2ILCA (ILC) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 187 Lamp Indications LAMP NAMECOLOR FUNCTION ACT1 Green No. 1 CircuitON: Normally operating OFF: Not operating PAL1 Red ON: Line is short-circuiting. OFF: Normally operating LPB1 Red OFF: Not used B21 Green ON: B2 channel is in use. OFF: B2 channel is idle. B11 Green ON: B1 channel is in use. OFF: B1 channel is idle. ACT0 Green No. 0 CircuitON: Normally operating OFF: Not operating PAL0 Red ON: Line is short-circuiting. OFF: Normally operating LPB0 Red OFF: Not used B20 Green ON: B2 channel is in use. OFF: B2 channel is idle. B10 Green ON: B1 channel is in use. OFF: B1 channel is idle.
NEAX2000 IVS2 ISDN System ManualPage 188 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2ILCA (ILC) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Piano Key SW)1 Always set to OFF. 2 Always set to OFF. 3 Always set to OFF. 4 Always set to OFF. SW0 (Piano Key SW) 1No. 0 Circuit (Receiving)Terminating register is provided. OFFTerminating register is not provided. 2No. 0 Circuit (Sending)Terminating register is provided. OFFTerminating register is not provided. 3No. 1 Circuit (Receiving)Terminating register is provided. OFFTerminating register is not provided. 4No. 1 Circuit (Sending)Terminating register is provided. OFFTerminating register is not provided. 4 3 2 1 OFF ON OFF OFF OFF OFF 4 3 2 1 OFF ON ON ON ON ON
NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 189 CHAPTER 5 OPERATION TEST This chapter explains the operation test to be performed after completion of the ISDN installation. For fault diagnosis by MAT or CAT, refer to the Maintenance Manual.