NEAX2000 IVS2 ISDN System ManualPage 40 ND-70919 (E), Issue 1.0 CHAPTER 2 INSTALLATION Required Equipment ISDN Terminal Required Equipment Ta b l e 2 - 3 shows the equipment required to provide ISDN Terminal interface to the system, in addition to the required equipment for ISDN-PRI or ISDN-BRI. Event Based CCIS Required Equipment Ta b l e 2 - 4 shows the required equipment to provide Event Based CCIS to the system, in addition to the required equipment for ISDN-PRI or ISDN-BRI. Table 2-3 ISDN Terminal Required Equipment EQUIPMENT DESCRIPTION QUANTITY REMARKS PN-SC03 (ICH)ISDN Channel Handler Card 1-12 4 ILC/card PN-2ILCA (ILC)ISDN Line Circuit Card 1-48 2 terminal/card Table 2-4 Event Based CCIS Required Equipment EQUIPMENT DESCRIPTION QUANTITY REMARKS PN-SC00 (CCH)Common Channel Handler Card1-8 1 DTI/card
CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 41 INSTALLATION PROCEDURE FOR ISDN-PRI Install the equipment for ISDN-PRI according to the procedure shown in Figure 2-2. NOTE:For Call Recording of ISDN call, install the equipment for SMDR or CIS. For details, refer to the Installation Procedure Manual. Figure 2-2 Installation Procedure for ISDN-PRI END START Mounting DTI and DCH Card/PRT Card Mounting CONN Card NOTE:This procedure is required when using CONN card to connect a coaxial cable for DTI. Selection of PLO in MP Card DTI/PRT Cable Connection via MDF Cable Connection via CONN CardSee Page 42. See Page 43. NOTE See CHAPTER 4. See Page 44. See Page 47. NOTE
NEAX2000 IVS2 ISDN System ManualPage 42 ND-70919 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI Mounting DTI and DCH Card/PRT Card (1) Before mounting the 24DTI (PN-24DTA-C)/PRT (PN-24PRTA)/30DTI (PN-30DTC-A) card and DCH (PN-SC01) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the 24DTI/30DTI/PRT card and the DCH card in the following AP slots on PIM0-PIM7: PIM 0-7: AP00-AP11 The AP11 slot on PIM0 is available only when the FP card is not mounted in the FP11 slot on PIM0. If you use the PRT card, the DCH card is not required because the PRT has a built-in DCH. NOTE:The DTI/PRT card (DTI/PRT0, DTI/PRT1) which sends a clock signal to PLO of the MP card must be mounted in the AP slots on PIM0. After mounting the card, set the MB switch to DOWN position to put the card in service. AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 43 Mounting CONN Card When using the CONN (PZ-M542/PZ-M557) card to connect a coaxial cable for DTI, do the following installation: (1) Confirm the correct switch settings of the CONN card. See CHAPTER 4. (2) Connect the CONN card to LTC connector on BWB in the PIM which accommodates DTI cards. For details, refer to the Installation Procedure Manual.
NEAX2000 IVS2 ISDN System ManualPage 44 ND-70919 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI DTI/PRT Cable Connection via MDF When you use a twisted-pair cable, connect the cable to a NT1 equipment via the MDF as shown in Figure 2-3. Location of AP Slots and LTC Connectors for DTI/PRT (Figure 2-4) Example of MDF Cross Connection for DTI/PRT(Figure 2-5) Figure 2-3 DTI/PRT Cable Connection via MDF NT1 MDF LT C 0 / LT C 1 / LT C 2 / LT C 3 TWISTED-PAIR CABLE DTI/PRT BWBPBX (SHIELD TYPE) MAX. 200 m (655 ft.) ......... 24-DTI MAX. 400 m (1310 ft.) ........ 30-DTI CONNECTOR
CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 45 Figure 2-4 Location of AP Slots and LTC Connectors for DTI/PRT LTC0 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25RA TA RA TA RA TA MJ RB TB RB TB RB TB MNRA TA RA TA RA TA RB TB RB TB RB TBRA TA RA TA RA TA RB TB RB TB RB TBRA TA RA TA RA TA RB TB RB TB RB TB 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 AP00 SLOT AP01 SLOT AP02 SLOT LTC1 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 AP03 SLOT AP04 SLOT AP05 SLOT LTC2 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 AP08 SLOT AP07 SLOT AP06 SLOT AP11 SLOT AP10 SLOT AP09 SLOT LTC3 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 L T 0 0 / A P 0 0L T 0 1 / A P 0 1L T 0 2 / A P 0 2L T 0 3 / A P 0 3L T 0 4 / A P 0 4L T 0 5 / A P 0 5L T 0 6 / A P 0 6L T 0 7 / A P 0 7L T 0 8 / A P 0 8L T 0 9 / A P 0 9L T 1 0 / A P 1 0L T 1 1 / A P 1 1
NEAX2000 IVS2 ISDN System ManualPage 46 ND-70919 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI Figure 2-5 Example of MDF Cross Connection for DTI/PRT PIM 0 JP MDF DTI/PRT AP05 RA RB TA TB17 42 18 4317 42 18 43RA RB TA TBTO NT1 LTC1 RECEIVE TRANSFER 17 18 19 20RA TA42 43 44 45RB TB LTC1 (J)42 43 44 45RB TB17 18 19 20RA TA LTC1 (P)
CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 47 Cable Connection via CONN Card When you use a coaxial cable, connect the cable to a NT1 equipment via the CONN (PZ-M542/ PZ-M557) card as shown in Figure 2-6. Figure 2-7 shows an example of the cable connection when the DTI/PRT card is mounted on the AP05 slot of PIM0. Figure 2-6 Cable Connection via the CONN Card NT1 LTC0/LTC1/LTC2/LTC3 CONNECTORCOAXIAL CABLE DTI/PRT BWBPBX MAX. 6 dB loss at 1024 kHz CONN
NEAX2000 IVS2 ISDN System ManualPage 48 ND-70919 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN-PRI Figure 2-7 Example of Coaxial Cable Connection COAXIAL CONNECTOR LTC1 CONNECTOR 17 18 19 20RA TA42 43 44 45RB TB LTC1 (J)42 43 44 45RB TB17 18 19 20RA TA LTC1 (P) PIM 0 JPCONN DTI/PRT AP05 RA RB TA TB17 42 18 4317 42 18 43TO NT1 LTC1 RECEIVE RCV SEND TRS 1 1 2 2
CHAPTER 2 INSTALLATION Installation Procedure for ISDN-BRI NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 49 INSTALLATION PROCEDURE FOR ISDN-BRI Install the equipment for ISDN-BRI according to the procedure shown in Figure 2-8. NOTE:For Call Recording of ISDN call, install the equipment for SMDR or CIS. For details, refer to the Installation Procedure Manual. Figure 2-8 Installation Procedure for ISDN-BRI END START Mounting BRT Card Selection of PLO in MP CardSee Page 50. See CHAPTER 4. BRT Cable Connection via MDFSee Page 51.