    							 NEAX2000 IVS2 ISDN System ManualPage 40  ND-70919 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Required Equipment
    ISDN Terminal Required Equipment
    Ta b l e  2 - 3 shows the equipment required to provide ISDN Terminal interface to the system, in
    addition to the required equipment for ISDN-PRI or ISDN-BRI.
    Event Based CCIS Required Equipment
    Ta b l e  2 - 4 shows the required equipment to provide Event Based CCIS to the system, in addition
    to the required equipment for ISDN-PRI or ISDN-BRI.
    Table 2-3  ISDN Terminal Required Equipment
    EQUIPMENT DESCRIPTION QUANTITY REMARKS
    PN-SC03 
    (ICH)ISDN Channel Handler Card 1-12 4 ILC/card
    PN-2ILCA 
    (ILC)ISDN Line Circuit Card 1-48 2 terminal/card
    Table 2-4  Event Based CCIS Required Equipment
    EQUIPMENT DESCRIPTION QUANTITY REMARKS
    PN-SC00 
    (CCH)Common Channel Handler 
    Card1-8 1 DTI/card 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 41
    INSTALLATION PROCEDURE FOR ISDN-PRI
    Install the equipment for ISDN-PRI according to the procedure shown in Figure 2-2.
    NOTE:For Call Recording of ISDN call, install the equipment for SMDR or CIS. For details, refer
    to the Installation Procedure Manual.
    Figure 2-2  Installation Procedure for ISDN-PRI
    END START
    Mounting DTI and
    DCH Card/PRT Card
    Mounting CONN Card
    NOTE:This procedure is required when using CONN card to connect a coaxial cable for
    DTI.
    Selection of PLO in
    MP Card
    DTI/PRT Cable
    Connection via MDF
    Cable Connection
    via CONN CardSee Page 42.
    See Page 43.
      NOTE
    See CHAPTER 4.
    See Page 44.
    See Page 47.
      NOTE 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 42  ND-70919 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    Mounting DTI and DCH Card/PRT Card
    (1) Before mounting the 24DTI (PN-24DTA-C)/PRT (PN-24PRTA)/30DTI 
    (PN-30DTC-A) card and DCH (PN-SC01) card, set the MB switch to UP 
    position, and set the other switches to appropriate position.
    See CHAPTER 4.
    (2) Mount the 24DTI/30DTI/PRT card and the DCH card in the following AP 
    slots on PIM0-PIM7:
    PIM 0-7: AP00-AP11
    The AP11 slot on PIM0 is available only when the FP card is not mounted in the FP11 slot 
    on PIM0.
    If you use the PRT card, the DCH card is not required because the PRT has a built-in DCH.
    NOTE:The DTI/PRT card (DTI/PRT0, DTI/PRT1) which sends a clock signal to PLO of the MP
    card must be mounted in the AP slots on PIM0.
    After mounting the card, set the MB switch to DOWN position to put the card in service.
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 43
    Mounting CONN Card
    When using the CONN (PZ-M542/PZ-M557) card to connect a coaxial cable for DTI, do the
    following installation:
    (1) Confirm the correct switch settings of the CONN card. See CHAPTER 4.
    (2) Connect the CONN card to LTC connector on BWB in the PIM which accommodates DTI 
    cards. For details, refer to the Installation Procedure Manual. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 44  ND-70919 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    DTI/PRT Cable Connection via MDF
    When you use a twisted-pair cable, connect the cable to a NT1 equipment via the MDF as shown
    in Figure 2-3.
     Location of AP Slots and LTC Connectors for DTI/PRT (Figure 2-4)
     Example of MDF Cross Connection for DTI/PRT(Figure 2-5)
    Figure 2-3  DTI/PRT Cable Connection via MDF
    NT1 MDF
    LT C 0 / LT C 1 / LT C 2 / LT C 3  TWISTED-PAIR
    CABLE DTI/PRT BWBPBX
    (SHIELD TYPE)
    MAX. 200 m (655 ft.)  ......... 24-DTI
    MAX. 400 m (1310 ft.) ........ 30-DTI CONNECTOR 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 45
    Figure 2-4  Location of AP Slots and LTC Connectors for DTI/PRT
    LTC0
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    MJ RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    MNRA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TBRA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TBRA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP00 
    SLOT
    AP01 
    SLOT
    AP02 
    SLOT
    LTC1
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP03 
    SLOT
    AP04 
    SLOT
    AP05 
    SLOT
    LTC2
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP08 
    SLOT
    AP07 
    SLOT
    AP06 
    SLOT
    AP11 
    SLOT
    AP10 
    SLOT
    AP09 
    SLOT
    LTC3
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
                         
    L
    T
    0
    0
    /
    A
    P
    0
    0L
    T
    0
    1
    /
    A
    P
    0
    1L
    T
    0
    2
    /
    A
    P
    0
    2L
    T
    0
    3
    /
    A
    P
    0
    3L
    T
    0
    4
    /
    A
    P
    0
    4L
    T
    0
    5
    /
    A
    P
    0
    5L
    T
    0
    6
    /
    A
    P
    0
    6L
    T
    0
    7
    /
    A
    P
    0
    7L
    T
    0
    8
    /
    A
    P
    0
    8L
    T
    0
    9
    /
    A
    P
    0
    9L
    T
    1
    0
    /
    A
    P
    1
    0L
    T
    1
    1
    /
    A
    P
    1
    1 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 46  ND-70919 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    Figure 2-5  Example of MDF Cross Connection for DTI/PRT
    PIM 0
    JP MDF DTI/PRT
    AP05
    RA
    RB
    TA
    TB17
    42
    18
    4317
    42
    18
    43RA
    RB
    TA
    TBTO NT1 LTC1
    RECEIVE
    TRANSFER
    17 
    18 
    19 
    20RA 
    TA42 
    43 
    44 
    45RB 
    TB LTC1 (J)42 
    43 
    44 
    45RB 
    TB17 
    18 
    19 
    20RA 
    TA LTC1 (P) 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 47
    Cable Connection via CONN Card
    When you use a coaxial cable, connect the cable to a NT1 equipment via the CONN (PZ-M542/
    PZ-M557) card as shown in Figure 2-6. 
    Figure 2-7 shows an example of the cable connection when the DTI/PRT card is mounted on the
    AP05 slot of PIM0.
    Figure 2-6  Cable Connection via the CONN Card
    NT1
    LTC0/LTC1/LTC2/LTC3 CONNECTORCOAXIAL CABLE DTI/PRT BWBPBX
    MAX. 6 dB loss at 1024 kHz
    CONN 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 48  ND-70919 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-PRI
    Figure 2-7  Example of Coaxial Cable Connection
    COAXIAL CONNECTOR LTC1 CONNECTOR
    17 
    18 
    19 
    20RA 
    TA42 
    43 
    44 
    45RB 
    TB LTC1 (J)42 
    43 
    44 
    45RB 
    TB17 
    18 
    19 
    20RA 
    TA LTC1 (P)
    PIM 0
    JPCONN
    DTI/PRT
    AP05
    RA
    RB
    TA
    TB17
    42
    18
    4317
    42
    18
    43TO NT1
    LTC1
    RECEIVE
    RCV
    SEND TRS
    1
    1
    2
    2 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure for ISDN-BRI
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 49
    INSTALLATION PROCEDURE FOR ISDN-BRI
    Install the equipment for ISDN-BRI according to the procedure shown in Figure 2-8.
    NOTE:For Call Recording of ISDN call, install the equipment for SMDR or CIS. For details, refer
    to the Installation Procedure Manual.
    Figure 2-8  Installation Procedure for ISDN-BRI
    END START
    Mounting BRT Card
    Selection of PLO in
    MP CardSee Page 50.
    See CHAPTER 4.
    BRT Cable Connection
    via MDFSee Page 51. 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Isdn System Manual