    							 NEAX2000 IVS2 ISDN System ManualPage 130  ND-70919 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Event Based CCIS Programming
    • To connect the ISDN line for the voice channel after the called party answers, do the
    following programming.
    By the following programming, the ISDN line for the voice channel is not connected, until the
    called par ty answers, or when the called par ty does not answers the call.
    NOTE:This feature is available only for the connection between the NEAX2000 IVS
    2/7400ICS
    M100MX’s. The same programming must be set on the opposite office.
    DESCRIPTION DATA
    Specify the ISDN answer signal sending 
    timing as “when the called party answers”.•
    (1)
    (2)YYY=153
    00-63: Trunk Route No. of Mate-Side
    Trunk for voice channels
    0: Send when the called party answers
    Specify the kind of the Information Transfer 
    Capability of voice channel trunk route as 
    “Speech”.
    (1)
    (2)YYY=154
    00-63: Trunk Route No. of Mate-Side
    Trunk for voice channels
    6: Speech
    CM35
    END
    START 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Event Based CCIS Programming
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 131
    Incoming Termination for Event Based CCIS Calls
    DESCRIPTION DATA
    Assign the Number Conversion Block No.•
    (1)
    (2)YY=00
    X-XXXX: DID No.
    000-999: Number Conversion Block 
    No. 0-999
    Conver t received digits to Mate-Side 
    trunks.
    
    
    
    (1)
    (2)YY=01 Day Mode
    YY=02 Night Mode
    YY=03 Mode A
    YY=04 Mode B
    000-999: Number Conversion Block 
    No. assigned by CM76 Y=00
    BBBBB000-BBBBB255: Mate-Side
     Trunk No. of 
    Virtual TrunkSTART
    CM76
    END 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 132  ND-70919 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Event Based CCIS Programming
    Access Code/Terminating Number Assignment 
    for Outgoing Event Based Calls
    DESCRIPTION DATA
    Allocate memory to store the terminating 
    numbers to the opposite office. (1)
    (2)66
    XXX YYY
    XXX: 000-299: First Memory Slot No.
    YYY: 001-016: Number of Memory Slot 
    allocated
    Assign terminating numbers of the 
    opposite office (access code for ISDN line 
    + ISDN subscriber number) to the Memory 
    Slot number allocated by CM71.
    (1)
    (2)Y=0
    000-299: Memory Slot No. 
    Stored No.: XX + , + ZZZ...
    XX : Access Code for ISDN
    ZZZ...: ISDN Subscriber No. of Oppo-
    site Office (Max. 26 digits)START
    CM71
    END
    CM72 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Event Based CCIS Programming
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 133
    Release Timer for Virtual Tie Lines 
    (Home-Side and Mate-Side Trunks)
    DESCRIPTION DATA
    Specify the release timer for voice 
    channels of virtual tie line. If there are no 
    calls for predetermined time, the voice 
    channels used for Event Based CCIS is 
    released.
    (1)
    (2)Y=0
    87: Virtual Tie Line Release Timer
        for Voice Channels
    02: 2.4-4.8 sec. (2.4 sec. increments)
    30: 69.6-72.0 sec.
    32: 24 sec. (24 sec. increments)
    70: 936 sec.
    72: 1 min. (1 min. increments)
    99: 28 min.
    NONE : 3 min.
    (Error span: 2.4 sec.)
    Specify the release timer for CCH channel 
    of virtual tie line. If all the voice channels 
    are released and there are no calls for 
    predetermined time, the CCH channel 
    used for Event Based CCIS is released.
    (1)
    (2)Y=0
    89: Virtual Tie Line Release Timer
    for Common Signaling Channel
    02: 2.4-4.8 sec. (2.4 sec. increments)
    30: 69.6-72.0 sec.
    32: 24 sec. (24 sec. increments)
    70: 936 sec.
    72: 1 min. (1 min. increments)
    99: 28 min.
    NONE : 3 min.
    (Error span: 2.4 sec.)START
    CM41
    END
    ~ ~
    ~ ~
    ~ ~
    ~
    ~
    ~ ~
    ~ ~ 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 134  ND-70919 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Event Based CCIS Programming
    CCH Data Assignment 
    DESCRIPTION DATA
    Assign an AP number to the CCH card 
    (PN-SC00).
    The AP number must match the SENSE 
    switch setting on the CCH card.
    (1)
    (2)Y=0
    04-15, 20-31: AP No.
    11: CCH Card
    Assign a CCH channel number to each 
    CCH card.
    (1)
    (2)YY=07
    0-7: CCH channel No.
    04-15, 20-31: AP No. of CCH Card
    Assign the trunk number used as the 
    common signaling channel.
    (1)
    (2)YY=00
    0-7: CCH channel No.
    000-255: Trunk No. assigned by CM07
    Assign an Originating Point Code (OPC) of 
    own office and Destination Point Code 
    (DPC) of opposite office, to each CCH 
    channel.
    NOTE:The OPC is used to designate an 
    originating office in the No. 7 CCIS 
    network. A single OPC of own 
    office should be assigned to all 
    CCH channels provided in the 
    same system.
    (1)
    (2)
    
    (1)
    (2)YY=01
    0-7: CCH channel No.
    00001-16367: OPC
    YY=02
    0-7: CCH channel No.
    00001-16367: DPC
    Assign ACM signal waiting timer.
    (1)
    (2)YY=10
    0-7: CCH channel No.
    14: 28 sec.
    Assign CCH channel to which a signaling 
    message is transferred according to the 
    Destination Point Code (DPC) received.(1)
    (2)00001-16367: DPC
    0-7: CCH channel No.
    CM06 START
    CM05
    CMA8
    END
    CMA7
    INITIAL
    INITIAL 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Event Based CCIS Programming
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 135
    Tandem Connection Programming
     When providing Tandem Connection (ISDN to CCIS/CCIS to ISDN), do the following
    programming:
    DESCRIPTION DATA
     Specify the combination of trunk routes 
    allowing the tandem connection.
    NOTE:The Home-Side Virtual Tie line 
    routes must be included for all 
    Tandem combinations.
    (1)
    (2)Y=0
    XX ZZ
    XX: 00-63: Incoming Trunk Route
    ZZ: 00-63: Outgoing Trunk Route
    0 : Allowed
    1: Restricted
    Tandem connection by station or 
    attendant.(1)
    (2)028
    0 : Available
    1 : Not availableSTART
    CM36
    END
    CM08 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 136  ND-70919 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Event Based CCIS Programming
    Closed Numbering Plan Programming
    DESCRIPTION DATA
    Assign LCR Group number to Area Code 
    Development Pattern.
    (1)
    (2)YYYY=A000
    0-3: LCR Group No.
    4000-4007: Area Code Development 
    Pattern No.
    Assign Area Code Development Pattern 
    number.
    (1)
    (2)YYYY=4000-4007
    X...XXX: Area Code (Max. 8 digits)
    0000-0255: Route Pattern No.
    Assign Route Pattern.
    (1)
    (2)YYYY=0000-0255
    1-4: 1st-4th Order
    XXX ZZ
    XXX: 000-255: LCR/TR Pattern No.
    ZZ :
     00-63: Trunk Route No.
     
    Assign maximum number of sending 
    digits.
    (1)
    (2)Y=0-7 Area Code Development Pattern 
    No. 0-7
    X...XX: Area Code (Max. 8 digits)
    01-79: Max number of sending digits
    START
    CM8A
    END
    CM85 
    						
    							NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 137
    CHAPTER 4
    CIRCUIT CARD 
    INFORMATION
    This chapter explains the mounting location, the meaning of lamp
    indications, and the method of switch settings of each circuit card for
    the ISDN system. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 138  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    How to Read This Chapter
    HOW TO READ THIS CHAPTER
    This chapter explains each circuit card used in this system. Explanations are given in
    alphabetical order of the circuit card names within each circuit card category (Control,
    Application Processor, and Line/Trunk).
    (1) Locations of Lamps, Switches, and Connectors
    The locations of lamps, switches, and connectors of each circuit card are shown by a face 
    layout.
    (2) Lamp Indications
    The name, color, and functions of each indicator lamp equipped on each circuit card are 
    described in a table.
    (3) Switch Settings
    The name, settings, and functions of each switch equipped on each circuit card are 
    described in a table.
    Each switch setting table has a CHECK column. Make necessary entries in the CHECK column
    during and/or after the system installation and maintenance, and use each table as a reference
    for subsequent system maintenance and operations. 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    Mounting Location of Circuit Card
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 139
    MOUNTING LOCATION OF CIRCUIT CARD
    This section explains the conditions for mounting circuit cards for the ISDN system. Figure 4-1
    shows circuit card mounting slots allocated in the PIM.
    Figure 4-1  Mounting Location of Circuit Card
    *1: PN-CP14 (MP) card on the MP12 slot on PIM0.
    *2: The following application processor cards can be mounted in the AP00-AP11 slots on
    PIM0-7.
    PN-BRTA (BRT)
    PN-2BRTC (BRT)
    PN-24DTA-C (DTI)
    PN-30DTC-A (DTI)
    PN-24PRTA (PRT)
    PN-SC00 (CCH)
    PN-SC01 (DCH)
    PN-SC03 (ICH)
    *3: PN-ILCA (ILC) card on the LT00-LT07 slots on PIM0-7.
    *4: PZ-M542/PZ-M557 (CONN) card on the LTC0-LTC3 connectors on the PIM which
    accommodates 30 DTI card.
    LT09/AP09LT08/AP08LT07/AP07
    LTC1LTC0LTC2
    BWB
    PIM
    0~7
    FRONTAC/DC
    PWR
    LT10/AP10LT00/AP00LT01/AP01LT02/AP02LT03/AP03LT04/AP04LT05/AP05LT06/AP06LT11/AP11/FP11MP12/FP12
    LTC3
    DC/DC
    PWR
    PFTVM
    *2*1
     *3
    *4 
    						
    All NEC manuals Comments (0)