    							 NEAX2000 IVS2 ISDN System ManualPage 190  ND-70919 (E), Issue 1.0
    CHAPTER 5  OPERATION TEST
    Interoffice Transmission Line Test
    INTEROFFICE TRANSMISSION LINE TEST
    To confirm inter-office synchronization and speech quality using “In-Service” transmission lines,
    do the following procedure:
    STEP 1: Connect the transmission line to the MDF or CONN card.
    STEP 2: Make busy the channels except the channel tested by CME5.
    STEP 3: Confirm indication lamps on the DTI/PRT/BRT card, as per the following table.
      Alarm Indications on 24DTI  (Ta b l e  5 - 1)
      Alarm Indications on 30DTI  (Ta b l e  5 - 2)
      Alarm Indications on 24PRT  (Table 5-3)
     Alarm Indications on BRT  (Ta b l e  5 - 4)
    STEP 4: Originate an outgoing call via trunk.
    STEP 5: After an outgoing connection via trunks has been established, confirm inter-office
    synchronization as follows:
      On the DTMF telephone set, keep pressing any dial button.
      Check to see if there are noise or abnormal tones.
      Do the above test again in the opposite direction.
    STEP 6: Repeat the test for all channels. When completed, make idle all channels by CME5. 
    						
    							CHAPTER 5  OPERATION TEST
    Interoffice Transmission Line Test
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 191
    Table 5-1  Alarm Indications on 24DTI
    LEDLED INDICATION FAULT
    NORMAL FAULT CAUSE ACTION
    RU N F la s h
    (120 IPM)On or Off Abnormal 
    operation of DTI 
    cardConfirm the programming data: 
    CM05, CM07 YY=01.
    Check to see if the SENS 
    switch is set as per the AP 
    number (04-15, 20-31) 
    assigned by CM05.
    Reset the MB switch 
    (Down→Up→Down)
    If the fault cannot be cleared, 
    replace the card.
    CRC Off On Bit Error Rate 
    exceeds the 
    predetermined 
    valueCheck the receive line and 
    external equipment.
    Replace the remote DTI card.
    PCM Off On No PCM signals 
    arrive from the 
    distant officeCheck to see if the DTI cable is 
    correctly connected.
    Plug and unplug the DTI card.
    Repeat this two or three times.
    FRM Off On Frame Alignment 
    signals from the 
    distant office can-
    not be receivedCheck the receive line and 
    external equipment.
    Replace the remote DTI card.
    RMT Off On Frame Alignment 
    signals cannot be 
    sent to the 
    remote PBXCheck the transmission line 
    and external equipment.
    Replace the DTI card.
    AIS Off On Remote PBX is in 
    the loop-back testCheck the switch settings of 
    the remote DTI card.1
    2
    3
    4
    1
    2
    1
    2
    1
    2
    1
    2
    1 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 192  ND-70919 (E), Issue 1.0
    CHAPTER 5  OPERATION TEST
    Interoffice Transmission Line Test
    Table 5-2  Alarm Indications on 30DTI
    LEDLED INDICATION FAULT
    NORMAL FAULT CAUSE ACTION
    RU N F la s h
    (120 IPM)On or Off Abnormal 
    operation of DTI 
    cardConfirm the programming data: 
    CM05, CM07 YY=01.
    Check to see if the SENS 
    switch is set as per the AP 
    number (04-15, 20-31) 
    assigned by CM05.
    Reset the MB switch 
    (Down→Up→Down)
    If the fault cannot be cleared, 
    replace the card.
    PCM Off On No PCM signals 
    arrive from the 
    distant officeCheck to see if the DTI cable is 
    correctly connected.
    Plug and unplug the DTI card.
    Repeat this two or three times.
    FRM Off On Frame Alignment 
    signals from the 
    distant office can-
    not be receivedCheck the receive line and 
    external equipment.
    Replace the remote DTI card.
    MFRM Off On Multi Frame 
    Alignment signals 
    from the distant 
    office cannot be 
    receivedCheck the receive line and 
    external equipment.
    Replace the remote DTI card.
    RMT Off On Frame Alignment 
    signals cannot be 
    sent to the 
    remote PBXCheck the transmission line 
    and external equipment.
    Replace the DTI card.
    MRMT Off On Frame Alignment 
    signals from the 
    distant office can-
    not be receivedConfirm the switch setting on 
    the DTI card indicating an 
    alarm.
    Replace the DTI card not indi-
    cating an alarm, with a spare.
    AIS Off On Remote PBX is in 
    the loop-back testCheck the switch settings of 
    the remote DTI card.1
    2
    3
    4
    1
    2
    1
    2
    1
    2
    1
    2
    1
    2
    1 
    						
    							CHAPTER 5  OPERATION TEST
    Interoffice Transmission Line Test
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 193
    Table 5-3  Alarm Indications on 24PRT
    LEDLED INDICATION FAULT
    NORMAL FAULT CAUSE ACTION
    RU N F la s h
    (120 IPM)On or Off Abnormal  opera-
    tion of PRT cardConfirm the programming data: 
    CM05, CM07 YY=01.
    Check to see if the SENS 
    switch is set as per the AP 
    number (04-15, 20-31) 
    assigned by CM05.
    Reset the MB switch 
    (Down→Up→Down)
    If the fault cannot be cleared, 
    replace the card.
    LC On Off ISDN primary 
    rate D-channel 
    data link connec-
    tion failureCheck the status of the local-office 
    side line or the public network side 
    line.
    CRC Off On Bit Error Rate 
    exceeds the pre-
    determined valueCheck the receive line and 
    external equipment.
    Replace the remote PRT card.
    PCM Off On No PCM signals 
    arrive from the 
    distant officeCheck to see if the PRT cable 
    is correctly connected.
    Plug and unplug the PRT card.
    Repeat this two or three times.
    FRM Off On Frame Alignment 
    signals from the 
    distant office can-
    not be receivedCheck the receive line and 
    external equipment.
    Replace the remote PRT card.
    RMT Off On Frame Alignment 
    signals cannot be 
    sent to the 
    remote PBXCheck the transmission line 
    and external equipment.
    Replace the PRT card.
    AIS Off On Remote PBX is in 
    the loop-back testCheck the switch settings of 
    the remote PRT card.1
    2
    3
    4
    1
    2
    1
    2
    1
    2
    1
    2
    1 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 194  ND-70919 (E), Issue 1.0
    CHAPTER 5  OPERATION TEST
    Interoffice Transmission Line Test
    Table 5-4  Alarm Indications on BRT
    LEDLED INDICATION FAULT
    NORMAL FAULT CAUSE ACTION
    BRT
    RU N F la s h
    (120 IPM)On or Off Abnormal 
    operation of BRT 
    cardConfirm the programming data: 
    CM05, CM07 YY=02.
    Check to see if the SENS 
    switch is set as per the AP 
    number (04-15) assigned by 
    CM05.
    Reset the MB switch 
    (Down→Up→Down)
    If the fault cannot be cleared, 
    replace the card.
    ALM Off On Transmission line 
    faultConfirm circuit line status.
    Confirm PSTN line status.
    2BRT
    RU N F la s h
    (120 IPM)On or Off Abnormal 
    operation of BRT 
    cardConfirm the programming data: 
    CM05.
    Check to see if the SENSE 
    switch is set as per the AP 
    number (04-15, 20-31) 
    assigned by CM05, CM07 
    YY=02.
    Reset the MB switch 
    (Down→Up→Down)
    If the fault cannot be cleared, 
    replace the card.
    ALM0 Off On No. 0 circuit 
    transmission line 
    faultConfirm No. 0 circuit line 
    status.
    Confirm PSTN line status.
    ALM1 Off On No. 1 circuit 
    transmission line 
    faultConfirm No. 1 circuit line 
    status.
    Confirm PSTN line status.
    1
    2
    3
    4
    1
    2
    1
    2
    3
    4
    1
    2
    1
    2 
    						
    							CHAPTER 5  OPERATION TEST
    PLO Operation Test
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 195
    PLO OPERATION TEST
    To confirm the PLO operation do the following tests:
     Clock Signal Generation Test
     Clock Signal Synchronization Test To be tested when the PBX is a clock receiver office.
     Interoffice Synchronization Test
     Source Office Mode Test To be tested when the PBX is a clock source office.
    Clock Signal Generation Test
    This test checks to see if the PLO keeps generating clock signals at the frequency of the previous
    source clock, when the source clock signal from network have stopped. Do the following
    procedure using “In Service” transmission lines.
    STEP 1: On all the DTI/PRT/BRT cards mounted in PIM0, set the switches as follows to stop
    the external clock signal input:
     30DTI card: SW-1 and SW-2 to OFF
      PRT/24DTI card: SW0-1 and SW0-2 to OFF
      BRT card: SW0-2 and SW0-3 to OFF
      2BRT card: SW11-2 and SW11-3 to OFF
    –  The CLK lamp on the MP card goes out.
    STEP 2: Originate an outgoing call via trunks.
    STEP 3: After an outgoing connection via trunks has been established, confirm interoffice
    synchronization and speech quality as follows:
      On the DTMF telephone set, keep pressing any dial button.
      Check to see if noise periodically occurs on the DTMF signals coming from the
    calling station in the opposite office.
      Do the above test again in the opposite direction.
    STEP 4: On all the DTI/PRT/BRT cards mounted in PIM0, restore the switches as the state
    before testing to input the external clock signals.
    – The CLK lamp on the MP card lights.
    NOTE:If noise periodically occurs, replace the MP card after checking the switch settings on
    the MP card, and do the above test again. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 196  ND-70919 (E), Issue 1.0
    CHAPTER 5  OPERATION TEST
    PLO Operation Test
    Clock Signal Synchronization Test
    This test checks to see if the PLO keeps synchronizing with the external clock signals, when the
    external clock signals from network has input again after it has stopped once. Do the following
    procedure using “In Service” transmission lines.
    (1) When providing one clock supply route 
    STEP 1: On the DTI0/PRT0/BRT0 card extracting clock signals, set the switches as follows to
    stop the external clock signal input:
      30DTI0 card: SW-1 and SW-2 to OFF
      PRT0/24DTI0 card: SW0-1 and SW0-2 to OFF
      BRT0 card: SW0-2 and SW0-3 to OFF
      2BRT0 card: SW11-2 and SW11-3 to OFF
    – The CLK lamp on the MP card goes out.
    STEP 2: Originate an outgoing call via trunk.
    STEP 3: After an outgoing connection via trunk has been established, confirm interoffice
    synchronization and speech quality as follows:
      On the DTMF telephone set, keep pressing any dial button.
      Check to see if noise periodically occurs on the DTMF signals coming from the
    calling station in the opposite office.
      Do the above test again in the opposite direction.
    STEP 4: On the DTI0/PRT0/BRT0 card, restore the switches as the state before testing to input
    the external clock signals:
      30DTI0 card: SW-1 to ON, SW-2 to OFF
      PRT0/24DTI0 card: SW0-1 to ON, SW0-2 to OFF
      BRT0 card: SW0-2 to ON, SW0-3 to ON
      2BRT0 card: SW11-2 to ON, SW11-3 to ON
    – The CLK lamp on the MP card lights.
    STEP 5: Originate an outgoing call via trunks. 
    						
    							CHAPTER 5  OPERATION TEST
    PLO Operation Test
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 197
    STEP 6: After an outgoing connection via trunks has been established, confirm interoffice
    synchronization and speech quality with the procedure shown in STEP 3.
    NOTE:If noise periodically occurs, replace the MP card after checking the switch settings on
    the MP card, and do the above test again.
    (2) When providing two clock supply routes
    STEP 1: On the DTI/PRT/BRT cards extracting clock signals, set the switches as follows to
    change the clock supply route from 0 to 1:
      30DTI0 card: SW-1 to OFF, SW-2 to OFF
      30DTI1 card: SW-1 to OFF, SW-2 to ON
      PRT0/24DTI0 card: SW0-1 to OFF, SW0-2 to OFF
      PRT1/24DTI1 card: SW0-1 to OFF, SW0-2 to ON
      BRT0 card: SW0-2 to OFF, SW0-3 to OFF
      BRT1 card: SW0-2 to ON, SW0-3 to OFF
      2BRT0 card: SW11-2 to OFF, SW11-3 to OFF
      2BRT1 card: SW11-2 to ON, SW11-3 to OFF
    STEP 2: Originate an outgoing call via trunks.
    STEP 3: After an outgoing connection via trunks has been established, confirm interoffice
    synchronization and speech quality as follows:
      On the DTMF telephone set, keep pressing any dial button.
      Check to see if noise periodically occurs on the DTMF signals coming from the
    calling station in the opposite office.
      Do the above test again in the opposite direction.
    STEP 4: On the DTI/PRT/BRT cards, set the switches as follows to stop the external clock
    signal input:
      30DTI0/1 card: SW-1 and SW-2 to OFF
      PRT0/1, 24DTI0/1 card: SW0-1 and SW0-2 to OFF
      BRT0/1 card: SW0-2 and SW0-3 to OFF
      2BRT0/1 card: SW11-2 and SW11-3 to OFF
    – The CLK lamp on the MP card goes out.
    STEP 5: Repeat STEP 2 and STEP 3 of this procedure. 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 198  ND-70919 (E), Issue 1.0
    CHAPTER 5  OPERATION TEST
    PLO Operation Test
    STEP 6: On the DTI0/1, PRT0/1, BRT0/1 cards, set the switches as shown in STEP 1 to input
    clock signals from the clock supply Route 1.
    STEP 7: Repeat STEP 2 and STEP 3 of this procedure.
    STEP 8: On the DTI/PRT/BRT cards, set the switches as follows to change the clock supply
    route from 1 to 0:
      30DTI0 card: SW-1 to ON, SW-2 to OFF
      30DTI1 card: SW-1 to OFF, SW-2 to ON
      PRT0/24DTI0 card: SW0-1 to ON SW0-2 to OFF
      PRT1/24DTI1 card: SW0-1 to OFF, SW0-2 to ON
      BRT0 card: SW0-2 to ON, SW0-3 to ON
      BRT1 card: SW0-2 to ON, SW0-3 to OFF
      2BRT0 card: SW11-2 to ON, SW0-3 to ON
      2BRT1 card: SW11-2 to ON, SW0-3 to OFF
    – The CLK lamp on the MP card lights.
    STEP 9: Repeat STEP 2 and STEP 3 of this procedure.
    NOTE:If noise periodically occurs, replace the MP card after checking the switch settings on
    the MP card, and do the above test again.
    Interoffice Synchronization Test
    This test checks to see if noise occurs while calling with the opposite office, by difference of the
    clock signal frequency between the offices. Do the following procedure using “In Service” trans-
    mission lines.
    STEP 1: Originate an outgoing call via trunks.
    STEP 2: Check the speech quality (if noise, distortion or click occurs during a few minutes) with
    the opposite office mutually.
    STEP 3: On the DTMF telephone set, keep pressing any dial button, and check to see if noise
    periodically occurs on the DTMF signals coming from the calling station in the opposite
    office. 
    						
    							CHAPTER 5  OPERATION TEST
    PLO Operation Test
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 199
    STEP 4: Do the above test again in the opposite direction.
    NOTE:If noise periodically occurs, replace the MP card after checking the switch settings on
    the MP card, and do the above test again.
    Source Office Mode Test
    When the PBX is operated as a clock source office, do the following procedure using “In Service”
    transmission lines.
    STEP  1: Confirm that the following switches on all the DTI/PRT/BRT cards mounted in PIM0 are
    set to OFF:
     30DTI card: SW-1 and SW-2 to OFF
      PRT/24DTI card: SW0-1 and SW0-2 to OFF
      BRT card: SW0-2 and SW0-3 to OFF
      2BRT card: SW11-2 and SW11-3 to OFF
    STEP 2: Confirm the following switches on the MP card are set to OFF:
      SW2-2 and SW2-3 to OFF
      SW4-2 and SW4-3 to OFF
    STEP 3: Confirm indication lamps on the MP card.
    NOTE:When the CLK lamp lights on the MP card, the clock signal is not generated from the
    MP card. Check the switch settings on the DTI, PRT, BRT and MP card. For details of
    the lamp indications, refer to CHAPTER 4.
    STEP 4: Originate an outgoing call via trunks.
    STEP 5: After an outgoing connection via trunk has been established, confirm interoffice
    synchronization and speech quality as follows:
      On the DTMF telephone set, keep pressing any dial button.
      Check to see if noise periodically occurs on the DTMF signals coming from the
    calling station in the opposite office.
      Do the above test again in the opposite direction.
    NOTE:If noise periodically occurs, replace the MP card after checking the switch settings on
    the DTI/PRT/BRT and MP card, and do the above test again. 
    						