    							 NEAX2000 IVS2 ISDN System ManualPage 140  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    LIST OF REQUIRED CIRCUIT CARDS
    Table 4-1 shows the required circuit cards that are explained in this section.
    * MB = Make Busy
    Table 4-1  List of Required Circuit Card
    NAME
    (FUNCTIONAL
    NAME)
    LAMP
    X: PROVIDED
    –: NOT 
    PROVIDEDSWITCH
    X: PROVIDED
    –: NOT 
    PROVIDEDEXTRACTION/
    INSERTION WITH 
    POWER ON
    X: ALLOWED
    : ALLOWED 
    AFTER MB*
    –: NOT ALLOWEDREFERENCE
    PAGE
    PN-CP14 (MP) X X –Page 141
    PN-BRTA (BRT) X XPage 146
    PN-2BRTC (BRT) X XPage 151
    PN-24DTA-C 
    (DTI)XXPage 156
    PN-30DTC-A 
    (DTI)XXPage 162
    PN-24PRTA 
    (PRT)XXPage 168
    PN-SC00 (CCH) X XPage 174
    PN-SC01 (DCH) X XPage 177
    PN-SC03 (ICH) X XPage 180
    PZ-M542 (CONN) – X XPage 182
    PZ-M557 (CONN) – X XPage 184
    PN-2ILCA (ILC) X X XPage 186 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-CP14 (MP)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 141
    PN-CP14 (MP)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    CLK Green Remains lit while receiving clock signals to the PLO
    SW3
    RUN
    SW1
    SW2
    CLK
    VR
    DK JACK CONNSW4
    JP0JP1
    RS1
    RS0
    CONN: To CONNR connector on PZ-M537 (EXPMEM) 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 142  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-CP14 (MP)
    Switch Settings
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:Only when executing MP Program Download using the Software Activation Tool in
    MATWorX Studio, set the SW3 to 5-8.
    CAUTION
    When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
    card into/from its mounting slot.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW3 (Rotary SW)
    NOTE 1
    0-FOn Line
    (Call processing is in progress)
    2 Off Line (Call processing is stopped)
    I/O port: As per CM40 YY=08
    3 Off Line (Call processing is stopped)
    I/O port: 9600 bps (Fixed)
    5
    NOTE 2Off Line (Call processing is stopped)
    I/O port: 9600 bps
    6
    NOTE 2Off Line (Call processing is stopped)
    I/O port: 19200 bps
    7
    NOTE 2Off Line (Call processing is stopped)
    I/O port: 38400 bps
    8
    NOTE 2Off Line (Call processing is stopped)
    I/O port: 57600 bps
    B For clearing the office data
    C For setting the resident system 
    program
    1, 4, 9
    A, D-FNot used
    (Continued)
    0
    0 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-CP14 (MP)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 143
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW1 (Push SW)For initializing CPU
    SW2
    (Piano Key SW)1ON A-law (Australia)
    OFF µ-law (North America)
    2, 3Selection of PLO0 input
    (Phase Locked Oscillator)
     For clock receiver office:
     For clock source office:
    SW2-2
    SW2-3
    OFF OFF
    4ONWhen using RS1 port for built-in 
    MODEM
    OFF When using RS1 port for RS-232C
    (Continued)
    4 
    3 
    2 
    1 OFF
    ONSW2-2 SW2-3 FUNCTION
    OFF OFF 1.5 MHz clock
    (For PN-24DTA-C/PN-24PRTA)
    ON OFF 192 kHz clock
    (For PN-BRTA)
    OFF ON 2 MHz clock
    (For PN-30DTC-A/PN-2BRTC)
    ON ON Not used 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 144  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-CP14 (MP)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW4 (DIP SW)1
    Not used
    2 Not used
    3, 4Selection of PLO1 input
    (Phase Locked Oscillator)
     For clock receiver office:
     For clock source office:
    SW4-3
    SW4-4
    OFF OFF
    VR (Rotary SW)
    Variable Resistor for External Hold 
    Tone Source
    (0-20 Kohms: Clockwise)
    DK (Connector)
    02 Ground detection
    01 Ground sending
    (Continued)
    1
    23
    4ON
    OFF
    OFF
    SW4-3 SW4-4 FUNCTION
    OFF OFF 1.5 MHz clock
    (For PN-24DTA-C/PN-24PRTA)
    ON OFF 192 kHz clock
    (For PN-BRTA)
    OFF ON 2 MHz clock
    (For PN-30DTC-A/PN-2BRTC)
    ON ON Not used
    20
    0
    01 02 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-CP14 (MP)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 145
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    JP0 (Jumper Pin)UPNot used
    (Memory backup OFF)
    For normal operation
    (Memory backup ON)
    JP1 (Jumper Pin)
    For using internal tone source
    DOWNFor using external tone source
    FrontDOWN
    Fr o n t
    UP 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 146  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-BRTA (BRT)
    PN-BRTA (BRT)
    Locations of Lamps, Switches, and Connectors
    SENSE
    RUN
    MB
    SW1
    SW0B1
    B2
    D
    ALM 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-BRTA (BRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 147
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally
    B1 Green B1 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    B2 Green B2 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    D Green D channel status
    ON: Busy
    OFF: Idle
    ALM Red Transmission line fault status
    ON: Line fault
    OFF: Normal operation 
    						
    							 NEAX2000 IVS2 ISDN System ManualPage 148  ND-70919 (E), Issue 1.0
    CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-BRTA (BRT)
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-15) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    SW0 (DIP SW)
    1For normal operation 
    OFF Not used
    2
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO of MP according to 
    the switch setting of SW0-3.
    OFFSource clock signal from network is 
    not sent to the PLO of MP card.
    3
    NOTE 3
    NOTE 4ONClock signal is sent to the PLO0 of 
    MP.
    OFFClock signal is sent to the PLO1 of 
    MP.
    4For normal operation
    OFF Not used
    (Continued)
    AP No.04 05 06 07 08 09 10 11 12 13 14 15
    SW No.456789ABCDEF
    ON
    DOWN
    1
    23
    4ON
    ON
    ON 
    						
    							CHAPTER 4  CIRCUIT CARD INFORMATION
    PN-BRTA (BRT)
    NEAX2000 IVS2 ISDN System Manual    
    ND-70919 (E), Issue 1.0   Page 149
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card. SW1 (DIP SW)
    1For terminating the transmitting side 
    of channels B1 and B2 with 100 
    ohms
    OFFTo remove the terminating resistor 
    on the transmitting side of channels 
    B1 and B2
    2For terminating the receiving side of 
    channels B1 and B2 with 100 ohms
    OFFTo remove the terminating resistor 
    on the receiving side of channels B1 
    and B2
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    2ONON
    ON 
    						