Home > NEC > Communications System > NEC Neax 2000 Ivs Wcs System Manual

NEC Neax 2000 Ivs Wcs System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs Wcs System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ND-46248 (E) CHAPTER 3
    Page 61
    Revision 2.0
    INSTALLATION
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION column
    indicate the standard setting of the switch. When the switch is not set as shown by the figure and   , the
    setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the intended switch position.
    Note 2:When the power is on flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Table 3-7  Switch Settings on CSH Card
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    Note 1
    4 ~ FSet the switch to match the AP Number (04 ~ 15) to be set by 
    CM05.
    0 ~ 3 Not used
    MB (Toggle SW)
    Note 2
    UP For make-busy
    For normal operation
    AP No.
    SW No.10 04 05 06 07 08 09 11 12 13 14 15
    456 78 9ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 62
    Revision 2.0
    INSTALLATION
    Table 3-8  Lamp Indications on CSH Card
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while the card is operating normally.
    DOPE7 Green Lights when No.7 circuit D channel link is connected.
    DOPE6 Green Lights when No.6 circuit D channel link is connected.
    DOPE5 Green Lights when No.5 circuit D channel link is connected.
    DOPE4 Green Lights when No.4 circuit D channel link is connected.
    DOPE3 Green Lights when No.3 circuit D channel link is connected.
    DOPE2 Green Lights when No.2 circuit D channel link is connected.
    DOPE1 Green Lights when No.1 circuit D channel link is connected.
    DOPE0 Green Lights when No.0 circuit D channel link is connected. 
    						
    							ND-46248 (E) CHAPTER 3Page 63
    Revision 2.0
    INSTALLATION
    4.6.4 Switch Settings of CSI Card
    On  the  CSI  ca rd, s et  th e  swi tc h es  as s hown  in  Figu re 3 -28  and  Tab le 3 -9 .
    T able  3 -10  s hows  lamp  ind ic ations  on  the CSI  c ard .
    Figure 3-28    Locations of Switches and Lamps on CSI Card
    B03B02 
    B01 
    B00
    OPE 
    LB 
    B13
    B12 
    B11 
    B10 
    DL1 
    DL0 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 64
    Revision 2.0
    INSTALLATION
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION column
    indicate the standard setting of the switch. When the switch is not set as shown by the figure and   , the
    setting of the switch varies with the system concerned.
    Note:Set the groove on the switch knob to the intended switch position.
    Table 3-9  Switch Settings on CSI Card
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    DL0 (Rotary SW)
    Note
    0 ~ FFor normal operation
    1 ~ F Not used
    DL1 (Rotary SW)
    Note
    0 ~ FFor normal operation
    1 ~ F Not used
    0
    0 
    						
    							ND-46248 (E) CHAPTER 3
    Page 65
    Revision 2.0
    INSTALLATION
    Table 3-10  Lamp Indications on CSI Card
    LAMP NAME COLOR FUNCTION
    OPE Green Lights when the corresponding circuit is in use.
    LB Red Lights when a loop-back is in progress.
    B13 Red Not used (Flash [60IPM])
    B12 RedB channel status
    ON  : B2 channel of the No. 1 circuit is in use.
    OFF : B2 channel of the No. 1 circuit is in idle.
    Flash (60 IPM)  : ZT is not connected to the No. 1 circuit.
    ZT is in make-busy status.
    B11 RedB channel status
    ON  : B1 channel of the No. 1 circuit is in use.
    OFF : B1 channel of the No. 1 circuit is in idle.
    Flash (60 IPM) : ZT is not connected to the No. 1 circuit.
    ZT is in make-busy status.
    B10 RedB channel status
    ON  : B0 channel of the No. 1 circuit is in use.
    OFF  : B0 channel of the No. 1 circuit is in idle.
    Flash (60 IPM)  : ZT is not connected to the No. 1 circuit.
    ZT is in make-busy status. 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 66
    Revision 2.0
    INSTALLATION
    B03 Red Not used (Flash [60 IPM])
    B02 RedB channel status
    ON  : B2 channel of the No. 0 circuit is in use.
    OFF  : B2 channel of the No. 0 circuit is in idle.
    Flash (60 IPM)  : ZT is not connected to the No. 0 circuit.
    ZT is in make-busy status.
    B01 RedB channel status
    ON  : B1 channel of the No. 0 circuit is in use.
    OFF  : B1 channel of the No. 0 circuit is in idle.
    Flash (60 IPM)  : ZT is not connected to the No. 0 circuit.
    ZT is in make-busy status.
    B00 RedB channel status
    ON  : B0 channel of the No. 0 circuit is in use.
    OFF  : B0 channel of the No. 0 circuit is in idle.
    Flash (60 IPM)  : ZT is not connected to the No. 0 circuit.
    ZT is in make-busy status.
    Table 3-10  Lamp Indications on CSI Card (Continued)
    LAMP NAME COLOR FUNCTION 
    						
    							ND-46248 (E) CHAPTER 3
    Page 67
    Revision 2.0
    INSTALLATION
    4.7 Mounting FP Card
    Mount one FP (PN-CP01) card in the FP slot of PIM0 in any configuration. When the system is equipped with
    more than two PIMs – depending on the number of additional PIMs used – mount one FP card in the FP slot of
    PIM0 and one FP card in the MP/FP slot of PIM2, PIM4 and PIM6.
    Figure 3-29    MP/FP Card Mounting Slots
    PIM3PIM7
    PIM2PIM6F
    PF
    P
    PIM1PIM5
    PIM0PIM4F
    PM
    PF
    P 
    						
    							CHAPTER 3 ND-46248 (E) 
    Pag e 68
    Revision 2.0
    INSTALLATION4.8 Mounting CSI Card
    Mount the CSI card in the LT slots of PIM0 through PIM7.
    Figure 3-30    Mounting Location of CSI Card (1 of 3)
    Note:  
    The  m aximum  number  o f f o ur P IM s c an be p owe re d  b y P W 91. ( Fig u re 3 -15 ). If  a  CSI  ca rd  i s  r e m ount ed
    in a PIM that is not powered by PW91, an external AC/DC adapter can be used to power the ZT. A max- 
    imum of 16 cards can be used; however, this number cannot be exceeded.)
    BUILT-IN BATTERY
     Mount the CSI card in the LT slots (LT00-LT15) on PIM0-PIM7.
    PIM 
    0 - 7
    P
    W
    R
    LT00LT01LT02LT03LT04LT05LT06LT07LT08LT09LT10/AP0LT11/AP1LT12/AP2LT13/AP3LT14/AP4LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
    AT T E N T I O NContents 
    Static Sensitive
    Handling 
    Precautions Required
       NEAX2000 IVS
    CSI CARD 
    						
    							ND-46248 (E) CHAPTER 3
    Page 69
    Revision 2.0
    INSTALLATION
    Figure 3-30  Mounting Location of CSI Card (2 of 3)
    Note:
    When mounting 8 circuits LT card with cabling in the LT08 slot, the CSI card cannot be mounted in the
    LT09 slot.
    CSI 
    CARD
    BUILT-IN BATTERY
    Mount the CSI card in the LT slots (LT00-LT09).
    PIM
    P
    W
    R
    LT00LT01LT02LT03LT04LT05LT06/AP0LT07/AP1LT08/AP2LT09/AP3LT10/AP4
    AP5MP
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
     Small Platform System 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 70
    Revision 2.0
    INSTALLATION
    Figure 3-30  Mounting Location of CSI Card (3 of 3)
    CSI 
    CARD
    BUILT-IN BATTERY
    Mount the CSI card in the LT slots (LT01-LT08).
    PIM
    P
    W
    R
    LT00LT01LT02LT03LT04/AP0LT05/AP1LT06/AP2LT07/AP3 LT08/AP4MP
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
     NEAX1000 IVS 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs Wcs System Manual