    							ND-46248 (E) CHAPTER 3
    Page 71
    Revision 2.0
    INSTALLATION
    4.9 Mounting CSH Card
    STEP 1: Mount the CSH card in the AP slots of PIM0 through PIM7.
    STEP 2: After mounting the card, set the SENSE switch to match an unequipped AP number in CM05. Set the
    MB switch to the down position to place the card in service. 
    Figure 3-31    Mounting Location of CSH Card (1 of 3)
    Note:
    (1) When the system is equipped with only PIM0:
    The CSH card can be mounted in the AP0 through AP5, and AP8 slots.
    (2) When the system is equipped with more than one PIM:
    The CSH card can be mounted in the AP0 through AP5 slots of PIM0.
    The CSH card can be mounted in the AP0 through AP6 slots of PIM2, 4 and 6.
    The CSH card can be mounted in the AP0 through AP7 slots of PIM1, 3, 5 and 7.
    CSH 
    CARD
    BUILT-IN BATTERY
    Mount the CSH card in the AP slots (AP0-AP8). Note
    Set the SENSE switch on the CSH card to match an unassigned slot number in CM05 as shown
    below.
    SLOT NUMBER
    SWITCH SETTING VALUE
    04
    4
    05
    5
    06
    6
    07
    7
    08
    8
    09
    9
    10
    A
    11
    B
    12
    C
    13
    D
    14
    E
    15
    F PIM
    0 - 7
    P
    W
    R
    LT00LT01LT02LT03LT04LT05LT06LT07LT08 LT09LT10/AP0LT11/AP1LT12/AP2LT13/AP3LT14/AP4LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
      NEAX2000 IVS 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 72
    Revision 2.0
    INSTALLATION
    Figure 3-31  Mounting Location of CSH Card (2 of 3)
    CSH 
    CARD
    BUILT-IN BATTERY
    Mount the CSH card in the AP slots (AP0-AP5).
    Set the SENSE switch on the CSH card to match an unassigned AP number in CM05 as shown
    below.
    SLOT NUMBER
    SWITCH SETTING VALUE
    04
    4
    05
    5
    06
    6
    07
    7
    08
    8
    09
    9
    10
    A
    11
    B
    12
    C
    13
    D
    14
    E
    15
    F PIM
    P
    W
    R
    LT00LT01LT02LT03LT04LT05LT06/AP0LT07/AP1LT08/AP2LT09/AP3LT10/AP4
    AP5MP
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
     Small Platform System 
    						
    							ND-46248 (E) CHAPTER 3
    Page 73
    Revision 2.0
    INSTALLATION
    Figure 3-31  Mounting Location of CSH Card (3 of 3)
    CSH 
    CARD
    BUILT-IN BATTERY
    Mount the CSH card in the AP slots (AP0-AP4).
    Set the SENSE switch on the CSH card to match an unassigned AP number in CM05 as shown
    below.
    SLOT NUMBER
    SWITCH SETTING VALUE
    04
    4
    05
    5
    06
    6
    07
    7
    08
    8
    09
    9
    10
    A
    11
    B
    12
    C
    13
    D
    14
    E
    15
    F PIM
    P
    W
    R
    LT00LT01LT02LT03LT04/AP0LT05/AP1LT06/AP2LT07/AP3 LT08/AP4MP
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
     NEAX1000 IVS 
    						
    							CHAPTER 3 ND-46248 (E) 
    Pag e 74
    Revision 2.0
    INSTALLATION4.10 Connection of ZT
    Conne ct  the  ca b le  to a  ZT v ia  the MDF as  s h own  in  Fi gure  3 -32 .
    F igu re 3 -33  sh ow s LTC  conn ec tor c orres spon ds wi th the  LT  slo ts, a nd  CSI pin  a ssig nm ent  for e ach LT s lot,  a nd
    F igu re  3-34  sh ow s an  ex am ple  of  the  c able  c o nne ction w hen  th e  C SI  card  is  moun ted  in  the  LT00  s lot  of  PIM0.
    Figure 3-32    Cable Connection via MDF for ZT
    Modular 
    MDF
    LTC0/LTC1/LTC2 CONNECTOR TWISTED-PAIR 
    CABLE
    CSI
    BWB
    PBX
    (PIM0, 2, 4, 6)Connector
    To ZT
    (SEE Figure 3-33 
    AND Figure 3-34) 
    						
    							ND-46248 (E) CHAPTER 3
    Page 75
    Revision 2.0
    INSTALLATION
    Figure 3-33    Location of LT Slots and LTC Connectors for ZT (1 of 3)
    LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
    LT14/AP4
    LT13/AP3
    LT12/AP2
    LT11/AP1
    LT00 LT01 LT02 LT09
    LT04 LT08
    LT07
    LT03 LT06
    LT05 LT10/AP0
    LTC0 LTC2LTC1 PIM
    0, 2, 4, 6P
    W
    R
    LTC0 LTC1 LTC2
    50 MN* 25 MJ* 50 25 50 25
    49B5324A53
    LT0549 BB3 24 AB3
    LT1149 24
    48 B52 23 A52 48 BB2 23 AB2 48 23
    47 B51 22 A51 47 BB1 22 AB1 47 22
    46 B50 21 A50 46 BB0 21 AB0 46 21
    45B4320A43
    LT0445 BA3 20 AA3
    LT1045 20
    44 B42 19 A42 44 BA2 19 AA2 44 19
    43 B41 18 A41 43 BA1 18 AA1 43 18
    42 B40 17 A40 42 BA0 17 AA0 42 17
    41B3316A33
    LT0341 B93 16 A93
    LT0941BF316AF3
    LT15 40 B32 15 A32 40 B92 15 A92 40 BF2 15 AF2
    39 B31 14 A31 39 B91 14 A91 39 BF1 14 AF1
    38 B30 13 A30 38 B90 13 A90 38 BF0 13 AF0
    37B2312A23
    LT0237 B83 12 A83
    LT0837BE312AE3
    LT14 36 B22 11 A22 36 B82 11 A82 36 BE2 11 AE2
    35 B21 10 A21 35 B81 10 A81 35 BE1 10 AE1
    34 B20 09 A20 34 B80 09 A80 34 BE0 09 AE0
    33B1308A13
    LT0133 B73 08 A73
    LT0733BD308AD3
    LT13 32 B12 07 A12 32 B72 07 A72 32 BD2 07 AD2
    31 B11 06 A11 31 B71 06 A71 31 BD1 06 AD1
    30 B10 05 A10 30 B70 05 A70 30 BD0 05 AD0
    29B0304A03
    LT0029 B63 04 A63
    LT0629BC304AC3
    LT12 28 B02 03 A02 28 B62 03 A62 28 BC2 03 AC2
    27 B01 02 A01 27 B61 02 A61 27 BC1 02 AC1
    26 B00 01 A00 26 B60 01 A60 26 BC0 01 AC0
    LTC0 LTC1 LTC2   NEAX2000 IVS 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 76
    Revision 2.0
    INSTALLATION
    Figure 3-33  Location of LT Slots and LTC Connectors for ZT (2 of 3)
    50 MN* 25 MJ* 50 25 50 25
    49 24
    LT0249 24
    LT0549 B93 24 A93
    LT09 48 23 48 23 48 B92 23 A92
    47 22 47 22 47 B91 22 A91
    46 21 46 21 46 B90 21 A90
    45 B23 20 A23 45 B53 20 A53 45 B83 20 A83
    LT08 44 B22 19 A22 44 B52 19 A52 44 B82 19 A82
    43 B21 18 A21 43 B51 18 A51 43 B81 18 A81
    42 B20 17 A20 42 B50 17 A50 42 B80 17 A80
    41 16
    LT0141 16
    LT0441 16
    LT07 40 15 40 15 40 15
    39 14 39 14 39 14
    38 13 38 13 38 13
    37 B13 12 A13 37 B43 12 A43 37 B73 12 A73
    36 B12 11 A12 36 B42 11 A42 36 B72 11 A72
    35 B11 10 A11 35 B41 10 A41 35 B71 10 A71
    34 B10 09 A10 34 B40 09 A40 34 B70 09 A70
    33 08
    LT0033 08
    LT0333 08
    LT06 32 07 32 07 32 07
    31 06 31 06 31 06
    30 05 30 05 30 05
    29 B03 04 A03 29 B33 04 A33 29 B63 04 A63
    28 B02 03 A02 28 B32 03 A32 28 B62 03 A62
    27 B01 02 A01 27 B31 02 A31 27 B61 02 A61
    26 B00 01 A00 26 B30 01 A30 26 B60 01 A60
    AP5MP
    LT10/AP4
    LT09/AP3
    LT08/AP2
    LT07/AP1
    LT00 LT01 LT02 LT04
    LT03 LT06/AP0
    LTC0 LTC2LTC1 PIM
    LTC0 LTC1 LTC2   Small Platform System
    Note:When mounting the Line/Trunk circuit card with 6 or 8 circuits into the LT08 slot, the LT09 slot
    cannot be used. 
    						
    							ND-46248 (E) CHAPTER 3
    Page 77
    Revision 2.0
    INSTALLATION
    Figure 3-33  Location of LT Slots and LTC Connectors for ZT (3 of 3)
    MP
    LT08/AP4
    LT07/AP3
    LT06/AP2
    LT05/AP1
    LT00 LT01 LT02
    LT03 LT04/AP0
    LTC0LTC1P
    W
    R
    LTC0 LTC1 LTC2
    50 MN 25 MJ 50 * 25 *
    49 24
    LT0349 24
    LT08 48 23 48 23
    47 22 47 22
    46 21 46 21
    45 B33 20 A33 45 B83 20 A83
    44 B32 19 A32 44 B82 19 A82
    43 B31 18 A31 43 B81 18 A81
    42 B30 17 A30 42 B80 17 A80
    41 16
    LT0241 B73 16 A73
    LT06/LT07 40 15 40 B72 15 A72
    39 14 39 B71 14 A71
    38 13 38 B70 13 A70
    37 B23 12 A23 37 B63 12 A63
    LT06 36 B22 11 A22 36 B62 11 A62
    35 B21 10 A21 35 B61 10 A61
    34 B20 09 A20 34 B60 09 A60
    33 08
    LT0133 B53 08 A53
    LT04/LT05 32 07 32 B52 07 A52
    31 06 31 B51 06 A51
    30 05 30 B50 05 A50
    29 B13 04 A13 29 B43 04 A43
    LT04 28 B12 03 A12 28 B42 03 A42
    27 B11 02 A11 27 B41 02 A41
    26 B10 01 A10 26 B40 01 A40
    LTC0 LTC1   NEAX1000 IVS
    * When AD8 is mounted in LT00, pins 25 and 50 of LTC1 bring out the AD8 internal modem leads. 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 78
    Revision 2.0
    INSTALLATION
    Figure 3-34    Example of Cable Connection via MDF for ZT (1 of 2) CAUTION:
     Incorrect wiring may cause severe damage to the equipment.
    PBX
    (PIM0, 2, 4, 6)
    BWB
    CSI
    TWISTED-PAIR
    CABLEMDF
    LTC0/LTC1/LTC2 CONNECTORMoldular
    Connector
    To ZT
    26 RB0 1 RA0
    27 TB0 2 TA0
    28 RB1 3 RA1
    29 TB1 4 TA1
    30 RB2 5 RA2
    31 TB2 6 TA2
    32 RB3 7 RA3
    33 TB3 8 TA3
    34 9
    35 10
    36 11
    37 12
    38 13
    39 14
    40 15
    41 16
    42 17
    43 18
    44 19
    45 20
    46 21
    47 22
    48 23
    49 24
    50 25ZT No. 0
    ZT No. 1
    ZT No. 2
    ZT No. 3
    Modular Jack
    (RJ-45)
    Modular plugTA
    RA TB
    RB
    ZT
    Note:Confirm that all feed polarity TA/TB and
    RA/RB is normal before connecting ZT to
    RJ-45 Modular jack.
    TA / T B m i n us
    RA/RB plus
    MDF
    TB
    RB
    RA
    TA 
    						
    							ND-46248 (E) CHAPTER 3
    Page 79
    Revision 2.0
    INSTALLATION
    Figure 3-34  Example of Cable Connection via MDF for ZT (2 of 2)
    12
    3
    4
    5
    6
    7 8
    Modular
    Connector
    (8)(1)
    Note:RJ-45 Modular Jack is highly recommended.
    Keep all wiring straight to the jack and perform all reverses at the cross connect for future chang-
    es.
    Assuming the PN-2CSI-A is in slot LTC0, please make the following connections.
    LTC0 RJ-45
    White-Blue Yellow
    Blue-White Black
    White-Orange Green
    Orange-White Red
    TERMINAL
    NUMBERCOLORTERMINAL 
    NUMBERFUNCTION POLARITY
    CSI
    TERMINAL TERMINAL 
    EQUIPMENTCSI SIGNAL FEED
    1 blue a Not used Not used
    2 orange b Not used Not used
    3 black c Transmission Reception + - RA
    4 red d Reception Transmission + - TA
    5 green e Reception Transmission - + TB
    6 yellow f Transmission Reception - + RB
    7 brown g Not used Not used
    8 slate h Not used Not used 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 80
    Revision 2.0
    INSTALLATION
    4.11 Connection of Battery
    CAUTION
    If battery terminals (+, –) contact with the module while connecting the battery cable to the PW86/PW91 card, the
    PW86/PW91 card or the BWB may be shorted. Therefore, the installer must perform work in accordance with the
    following steps when mounting or removing the batteries.
    (1) When mounting batteries:
    (a) Connect the battery cable to the batteries.
    (b) Mount the batteries into the appointed position of the PIM or the BATTM.
    (c) Connect the battery cable to the PW86/PW91 card.
    (2) When removing batteries:
    (a) Disconnect the battery cable from the PW86/PW91 card.
    (b) Remove the batteries from the PIM or the BATTM. 
    						