    							ND-46248 (E) CHAPTER 2Page 3
    Revision 2.0
    CHAPTER 2 SYSTEM DESCRIPTION
    1. GENERAL 
    This chapter explains the system configuration, additional hardware and system specifications pertaining to the 
    WCS. 
    2. SYSTEM CONFIGURATION
    2.1 System Outline
    The wireless communication system (WCS) is interfaced with a Personal Station (PS) via a Zone Transceiver 
    (ZT). 
    When installing the WCS, there are three types of systems: 
    1. Integrated Type The NEAX2000 IVS/1000 IVS provides both PBX and WCS functions.
    2. Adjunct Type [1] The WCS is an adjunct system to the existing PBX linked by LC-COT connection.
    3.   Ad jun ct  Type  [2]
    The WCS is an adjunct system to the existing PBX linked by CCIS.
    F igu re  2-1  shows  the sy ste m  di agr am of  the  W CS.
    Figure 2-1    System Diagram of WCS Integrated Type (1 of 2)
    CSICOT
    LC
    DATCSH
    ZT
    SLT
    PSTN
    PS
    PS
    PS WCS
    (1) Integrated Type
    PS : Personal Station 
    ZT : Zone Transceiver
    CSI : ZT Interface 
    CSH : ZT Handler 
    DAT : Digital Announcement Trunk
    : Virtual LC-COT Connection
    LC : Line Circuit
    DLC: : Digital Line Circuit
    COT : Central Office Trunk
    LC
    COT*
    *
    DtermDLC 
    						
    							CHAPTER 2 ND-46248 (E)
    Pag e 4
    Revision 2.0
    SYSTEM DESCRIPTION
    Figure 2-1  System Diagram of WCS (2 of 2)
    CSICOT
    DATCSH ZT
    PS
    PS
    PSWCS
    LC
    PBX
    CSIDTI
    DATCSH ZT
    PS
    PS
    PSWCS
    PS : Personal Station
    ZT : Zone Transceiver
    CSI : ZT Interface
    CSH : ZT Handler
    DAT : Digital Announcement Trunk
    * : Virtual LC-COT Connection
    LC
    COT*
    (2) Adjunct Type [1]
    (3) Adjunct Type [2]
    DTI
    PBX
    CCIS 
    						
    							ND-46248 (E) CHAPTER 2Page 5
    Revision 2.0
    SYSTEM DESCRIPTION
    2.2 CSH
    E xampl es of  mod ule  con fig ur ations  a re s hown  in  F igu re 2 -2.
    Figure 2-2    Module Configurations (1 of 4)
    Note:
    For WCS application, ICSVS PIMN-UB is required for each PIM.
    RACK PARTS
    PWRM
    BASE
    FRONT
    17/
    9.8/24.89
    31/78.74
    PIM0
    (1)  1-PIM Configuration
    Unit : inches/centimeters
    43.18 
    						
    							CHAPTER 2 ND-46248 (E)
    Pag e 6
    Revision 2.0
    SYSTEM DESCRIPTION
    Figure 2-2  Module Configurations (2 of 4)
    PIM7
    PIM6
    PIM4 PIM3
    PIM2
    PIM1
    PIM0
    FRONTRACK PARTS
    BASE PWRM
    (2)  Multiple PIM Configuration for NEAX2000 IVS
    Dummy PIM/
    BATTM/MDFM
    34/
    9.8/24.89
    Unit : inches/centimeters
    PIM5
    77.2/196.09 86.36 
    						
    							ND-46248 (E) CHAPTER 2
    Page 7
    Revision 2.0
    SYSTEM DESCRIPTION
    Figure 2-2  Module Configurations (3 of 4)
    RACK PARTS
    PWRM
    BASE
    FRONT
    17/ 9.8/24.89
    29.3/74.42 PIM0
    (4)  Maximum Configuration for Small Platform System
    Unit : inches/centimeters
    BASE
    17/43.18 7.2/18.29
    15.5/39.37 PIM0
    (3)  Minimum Configuration for Small Platform System
    FRONT
    43.18 
    						
    							CHAPTER 2 ND-46248 (E)
    Pag e 8
    Revision 2.0
    SYSTEM DESCRIPTION
    Figure 2-2  Module Configurations (4 of 4)
    Unit : inches/centimeters
    13.8/35.05 8.521.59
    13.8/35.05 PIM0
    (5)  PIM Configuration for NEAX1000 IVS
    FRONT 
    						
    							ND-46248 (E) CHAPTER 2Page 9
    Revision 2.0
    SYSTEM DESCRIPTION
    2.3 Outline of Circuit Cards
    T able  2 -1  sh ows  the  fun ction al o utli n e of  c ir c uit  c ards  u sed  fo r  W CS.
    Ta b le  2 -1    Fun ction al O utline  of  Cir cuit Card
    CARD NAME FUNCTIONAL
    NAME FUNCTIONAL OUTLINE
    PN-SC03 CSHZT Handler card. 
    This card controls 4 CSI cards and is equipped with 8 circuits of D channel  
    signalling interface.
    PN-2CSIA CSI ZT Interface card. 
    This card is used to interface with ZT, based on ISDN S-interface. 
    Max. 2 ZTs can be connected with 1 CSI card.
    PZ-PW91 PW91 -48 V power supply card for ZT. 
    A PW91 card provides -48V DC power for a maximum of 24 ZTs. 
    Max. 4 cards per PWRM.
    PZ-PW86 PW86 Main Power Supply card. 
    This card provides power to all circuit cards mounted in the PIM. 
    1 card per PIM.
    PZ-PW00 PW00 Power Supply card for ZT. 
    This card provides -48 V DC power for a maximum of 2 ZTs and is mounted  
    in the LT/AP slot of PIM. Max 3 cards per system.
    PN-2DATA DAT 2-line Digital Announcement Trunk card. 
    This card is used for Announcement Service on the WCS. 
    Recording time: Max. 60 seconds.
    PN-4COTB COT 4-line Central Office Trunk card. 
    This card is used for Adjunct Type 1 (LC-COT connection). 
    A 4 COT card is required per 4 PSs.
    PN-24DTA DTI 24 Channel Digital Trunk Interface card. 
    This card accommodates 24 channel PCM digital line and is used for CCIS  
    connection of Adjunct Type 2.
    PN-30DTC DTI 30 Channel Digital Trunk Interface card. 
    This card accommodates 30 channel digital PCM line and is used for CCIS  
    connection of Adjunct Type 2, or for Multi-Site Roaming connection be- 
    tween the PBXs.
    PN-SC00 CCH Common Channel Handler card. 
    This card controls common signalling channels of No.7 CCIS and is used for  
    CCIS connection of Adjunct Type 2.
    PN-SC01 DCH D-Channel Handler card.
    This card transmits/receives control signals for Multi-Site Roaming connec-
    tion between the PBXs. 
    						
    							CHAPTER 2 ND-46248 (E)
    Pag e 10
    Revision 2.0
    SYSTEM DESCRIPTION
    Note:
    When the PWRU-A is equipped with the PZ-PW112 for NEAX1000 IVS, follow the following accommo-
    dation limitations.
    Max. five 8DLC cards
    or
    Max. four 8DLC cards and two 4DIT cards. PN-AP00-A DBMData Base Module card for Multi-Site Roaming.
    This card stores data related to Multi-Site Roaming.
    1 card per system is required on each PBX in the network which provides 
    Multi-Site Roaming.
    PWRU-A
    Note
    –48V/50W
    DC/DC PWRPower Supply Unit for ZT. (for NEAX1000 IVS only)
    This unit provides –48V DC power for a maximum of 6 ZTs, and is mounted 
    in the vacant space at the lower left side of a Main Power Supply card. 1 unit 
    per PIM is available.
    Table 2-1  Functional Outline of Circuit Card
    CARD NAMEFUNCTIONAL
    NAMEFUNCTIONAL OUTLINE 
    						
    							ND-46248 (E) CHAPTER 2
    Page 11
    Revision 2.0
    SYSTEM DESCRIPTION
    3. SYSTEM SPECIFICATIONS
    3.1 System Specifications
    Table 2-2  System Specifications
    DESCRIPTION SPECIFICATIONS REMARKS
    Wireless ProtocolBased on second generation wireless telephone 
    system standard RCR-STD-28 FCC Sub part D, 
    UTAM complied
    Distance between PBX and 
    ZT
    Note:At Nominal Voltage of -48V.
    Interface with a PBXAnalog station line interface For Adjunct Type [1]
    TI or EI interface with CCIS For Adjunct Type [2]
    WIRE DIAMETER 26 AWG 24 AWG 22 AWG
    POWER SUPPLY WCS LOCAL WCS LOCAL WCS LOCAL
    DISTANCE1500 ft.
    (457 m)2000 ft.
    (609 m)2000 ft.
    (609 m)3000 ft.
    (914 m)3000 ft.
    (914 m)3300 ft.
    (1000 m) 
    						
    							CHAPTER 2 ND-46248 (E)
    Page 12 Addendum-001
    Revision 2.1 MARCH, 1999
    SYSTEM DESCRIPTION
    3.2 System Capacity
    Note 1:
    When Multi-Site Roaming is provided, “Number of PS” and “Number of simultaneous connections for
    PS” equal the sum of the Number of the Home PS and the Visitor PS.
    Note 2:The capacity of the PSs can be expanded to the number in parentheses. For details, refer to next section.
    Table 2-3  NEAX2000 IVS WCS System Capacity
    DESCRIPTIONCAPACITY
    REMARKS
    Integrated TypeAdjunct Type
    Ty p e 1
    (LC-COT)Ty p e 2
    (CCIS)
    Number of PS Note 1168
    (250) 
    Note 2248162
    (232) Note 2
    Number of simultaneous 
    connections for PS  
    Note 1
    152
    (159) 
    Note 2
    219
    (234) 
    Note 2
    146
    (153) 
    Note 2
    Number of B channels per 
    ZT (Simultaneous 
    connections per ZT)33 3
    Number of ZT 96 96 80
    Number of ZT per CSI 2 2 2
    Number of Calling Areas 32 32 32
    Number of ZT per Calling 
    Area96 96 80
    Number of CSI 48 48 40Max. 12 per PIM
    (No local power 
    supplied)
    Number of CSH 12 12 10 
    						