    							ND-46248 (E) CHAPTER 3
    Page 81
    Revision 2.0
    INSTALLATION
    CAUTION
    Battery Replacement Table and Battery Warnings
    The label which shows battery replacement table and battery warnings is attached to the reverse side of Front
    Cover for PIM, BATTM and PWRM.
    During the battery installation process, the warning statements must be observed. When replacing batteries,
    the battery replacement table should be observed in order to increase battery life and insure a safe operation.
    25 ~ 30°C
    2.0 ~ 2.5 (77 ~ 86°F)
    LABEL PIM/BATTM/PWRM
    FRONT COVER
    BATTERY REPLACEMENT TABLE
    INSTALLATION DATE: , .
    AMBIENT 
    TEMPERATURELESS THAN
    25°C (77°F)
    REPLACEMENT
    INTERVAL2.5 ~ 3.0 1.5 ~ 2.0CAUTIONTO PREVENT INJURY AND SKIN BURN,
    PAY ATTENTION TO THE FOLLOWING.
    o DO NOT STRIKE A MATCH OR CAUSE A SPARK IN
    VICINITY OF BATTERY.
    o PLACE THE EQUIPMENT WELL VENTILATED 
    AREA.
    o DO NOT SHORT.
    o REPLACE BATTERY ONLY AFTER BATTERY 
    GASES HAVE BEEN DISPERSED.
    o ELECTROLYTE LEAKAGE OR OTHER HAZARDS
    MAY RESULT IF THE BATTERY IS NOT REPLACED
    IN ACCORDANCE WITH THE SPECIFIED INTER-
    VALS.
    (86 ~ 104°F) 30 ~ 40°C
    YEARS YEARS YEARS 
    						
    							CHAPTER 3 ND-46248 (E) 
    Pag e 82
    Revision 2.0
    INSTALLATION4.11.1 Internal Battery Connection
    STEP  1:  Mount  th e t wo b atte ries  (1 2V  DC, 3. 0–3 .4 A H f o r  PW 86  c ard ) in to  e a ch  P IM  as s h ow n in  F ig u re  3-
    3 5.
    Figure 3-35    Internal Battery Mounting (1 of 2)
    Note:
    The two 2/12V batteries do not backup power feeding 2Ts, which can be backed up by adding 48V bat- 
    tery. See Section 4.11.2.
    FRONT
    W 67 mm
    DIMENSION OF BATTERY
    BATTERY UNIT 
    (2 
    × 12VDC, 3.0 to 3.4AH)
    (2.6 inch) L 134mm(5.3 inch)
    H 60 mm
    (2.4 inch)
    BASE 
    PWRM 
    PIM
    FG
     N
    EU T
    R AL  
    L
    IN
    E
    Blue
    Red
    Black 
    						
    							ND-46248 (E) CHAPTER 3Page 83
    Revision 2.0
    INSTALLATION
    Figure 3-35  Internal Battery Mounting (2 of 2)
    Note:
    The two (2) 12V batteries do not backup power feeding ZTs, which can be backed up by adding 48V 
    b atter y.  See  Se ction 4 .11.2 .
    FRONT
    W 34 mm DIMENSION OF BATTERY
    BATTERY UNIT 
    (2 
    × 12V DC, 2.6AH)
    (1.3 inch) L 178 mm(7.1 inch)
    H 60 mm
    (2.4 inch) PIM
    Blue
    Red
    Pin # 4
    Pin # 1
    
      NEAX1000 IVS
    Recommended Battery 
    GS type PX12026
    Black 
    						
    							CHAPTER 3 ND-46248 (E) 
    Pag e 84
    Revision 2.0
    INSTALLATION
    STEP 2:  Plug  the b atte ry ca ble  c onn ec tor  in to the  B ATT1  con nec tor  o n the  P W 86 ca rd as  sh ow n in  Fig ure  3-
    3 6.
    STEP  3:  Secu re  the  batt e rie s  and b atte ry c ab le u sing  t ie w raps  as  sh ow n  in  Figu re 3 -36 .
    Figure 3-36    Internal Battery Connection
    PLUG IN TO BATT 1 
    CONNECTOR ON PZ-PW86
    FRONT
    TIE WRAP
    PIM
    BATTERY CABLE 
    						
    							ND-46248 (E) CHAPTER 3Page 85
    Revision 2.0
    INSTALLATION
    STEP 4: When the system is a multiple PIM configuration, plug the PWR CA-A into the BATT2 connector on the  PW 86  ca rd  as s how n in  Fig ure  3-37.
    Figure 3-37    Internal Battery Connection for a Multiple PIM Configuration
    PWR CA-A
    BATT2 
    BATT1
    PW86
    –+–+
    PIM3
    BATT2 
    BATT1
    PW86
    –+–+
    PIM2
    BATT2 
    BATT1
    PW86
    –+–+
    PIM1
    BATT2 
    BATT1
    PW86
    –+–+
    PIM0
    BATTERY CABLE
    BATT2 
    BATT1
    PW86
    –+–+
    PIM7
    BATT2 
    BATT1
    PW86
    –+–+
    PIM6
    BATT2 
    BATT1
    PW86
    –+–+
    PIM5
    BATT2 
    BATT1
    PW86
    –+–+
    PIM4
    BATTERY CABLE
    PWR CA-A
    PWR CA-A PWR CA-A
    Blue
    Red 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 86
    Revision 2.0
    INSTALLATION
    Figure 3-38    PWR CA-A
    550 mm (21.7 inch)
    PWR CA-A 
    						
    							ND-46248 (E) CHAPTER 3
    Addendum-001 Page 87
    MARCH, 1999 Revision 2.1
    INSTALLATION
    4.11.2 Battery Connection in PWRM
    When the system is equipped with one or two PW91 card, the battery for PW91 card can be mounted into the
    Power Module (PWRM). When the system is equipped with more than two PW91 card, refer to Section 4.11.3.
    Note:A 48V battery (4x12 VDC) is required to back up PW91 for ZT power feeding.
    STEP 1: Connect the battery cables to the batteries as shown in Figure 3-39.
    Figure 3-39    Battery Connection into PWRM
    Recommended Battery
    Yuasa NP7-12
    Specifications
    UL Listed
    12VDC, 7AH
    Terminal : Fasten Tab type
    Dimensions : 151 mm L x 65 mm W x 94 mm H
    (59.4 in. L x 25.6 in. W x 37 in. H)
    Into PWRM BATTERY CABLE
    BATTERY UNIT
    (4 X 12VDC, 7AH)
    RED BLUE 
    						
    							CHAPTER 3 ND-46248 (E) 
    Pag e 88
    Revision 2.0
    INSTALLATION
    STEP 2:  Secu re  t he B atte ry Br ac k et   a nd   t o  th e  PW RM as  sh ow n  in  Figu re  3-40 .
    STEP  3:  Mount  t he  batte ry u nit  ( 4 x12 VDC,  7A H  per un it)  i n to  the  P W RM as  sh ow n  in  Figu re  3-40 .
    STEP  4:  Secu re  t he B atte ry Br ac k et  to  the  PW RM as  sh ow n  in  Figu re 3 -40 .
    Figure 3-40    Battery Mounting into PWRM
    12
    3
    BATTERY BRACKET 1BATTERY UNIT (4x12 VDC, 7AH)
    BATTERY BRACKET 3
    BATTERY BRACKET
    2
    BATTERY BRACKET3
    PWRM 
    						
    							ND-46248 (E) CHAPTER 3Page 89
    Revision 2.0
    INSTALLATION
    STEP  5:  Plug  the b atte ry ca ble  c onn ec tor  in to the  B ATT2  con nec tor  o n the  P W 91 ca rd as  sh ow n in  Fig ure  3-
    4 1.
    STEP  6:  Co nne ct  the PW91  ca rd s  to  each  o ther  us ing  the  P W R CA -A as  sh ow n  in  Figu re 3 -41 .
    Figure 3-41    Battery Connection in PWRM
    PWRM
    PW91
    BATT2 
    BATT1PW91
    BATT2 
    BATT1
    PWR CA-A BATTERY UNIT (48VDC, 7AH)
    BATTERY CABLE 
    						
    							CHAPTER 3 ND-46248 (E) 
    Pag e 90
    Revision 2.0
    INSTALLATION4.11.3 Battery Connection in BATTM
    1. For PW86 card (-24 V DC) 
    STEP 1: Connect the battery cables to the batteries, and mount the battery units (2 ×12 V DC, 24AH per unit)
    i n to t he Ba tt e ry  M odule  ( B ATTM)  as sh ow n  in  Figur es  3-42 and  3-4 3.
    Figure 3-42    Battery Mounting into BATTM for PW86 Card
    Recommended Batteries
    GS Portalac PE12V 24ABI 
    Yuasa NP24-12B
    Specifications UL Listed 
    12V DC, 24AH
    Terminal:  bolt/nut type with hole for 5mm bolt 
    Dimensions:175 mm L  ×
     166 mm W  ×
     125 mm H
    (6.89 in L  ×
     6.54 in W  ×
     4.92 in H)
    A: 12 mm
    5.5 mm
    B: 2 mm
    (.216 in) (.472 in)
    (.079 in) Pin # 4
    BATTERY CABLE
    BATTM
    BATTERY UNIT (2x12 V DC, 24AH)
    BATTERY UNIT (2x12 V DC, 24AH)
    FRONT
    TO PW86 CARD IN PIM0/PIM4Blue
    Red
    Black
    Pin # 1 
    						