    3.6.4 Group Call-Automatic Conference (6/10 Party) Data Assignment
    To provide the Group Call-Automatic Conferrence (6/10 Party):
    DESCRIPTION DATA
    Assign a Conference Trunk Card Number to 
    the required LEN.(1)
    (2)LEN (0000-0511)
    ED00-ED03: Conference Trunk Card No.
    Assign the stations which belongs to each pag-
    ing group, and their number within the group. 
    A maximum of 9 stations can be paged simul-
    taneously except the conference leader.
    Note 1:Single line telephones, Multline
    Terminals and PS can be as-
    signed as the station within the
    group.
    A virtual-line cannot be as-
    signed.
    Note 2:A station can belong to multiple
    groups.
    (1)
    (2)YY=00-07: Simultaneous Paging Group 0-
    7
    00-15: Serial No. within the Group
    X-XXXX: Station No.
    Assign a Service Restriction Class to each sta-
    tion.
    (1)
    (2)YY=02
    X-XXXX: Station No.
    XX
     XX
    00-15 : Service Restriction 
    Class A
    Allow the Service Restriction Class A to page 
    the group.
    (1)
    (2)YYY=119
    00-15: Service Restriction Class A assigned 
    by CM12 YY=02
    0: Allowed
    Assign the access code of paging groups for 
    Group Call-Automatic Conference (6/10 Par-
    ty).
    Note:Even if an extension does not be-
    long to the conference group, the
    extension can page the confer-
    ence group, and can re-partici-
    pate in the conference if there is
    an idle circuit on the Conference
    Tr u n k .
    (1)
    (2)Y=0-3 (Tenant Group No.)
    X-XX: Access Code
    B00: Simultaneous Paging Group 0
    B07: Simultaneous Paging Group 7
    B10: Re-participation Group 0
    B17: Re-participation Group 7
    START
    CM56
    CM12
    CM20
    CM15
    A
    CM10
    INITIAL
    ~ ~
    ~ ~ 
    						
    							CHAPTER 4 ND-46248 (E)
    Pag e 14 0
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Assign a Group Call-Automatic Conference 
    (6/10 Party) key of each paging group to the 
    Multiline Terminal, if required.
    Note:Even if an extension does not be-
    long to the conference group, the
    extension can page the confer-
    ence group, and can re-partici-
    pate in the conference if there is
    an idle circuit on the Conference
    Tr u n k .
    (1)
    (2)Y=00
    X-XXXX: Primary Extension No. +  
    +key No.
    F0B00: Simultaneous Paging Group 0
    F0B07: Simultaneous Paging Group 7
    F0B10: Re-participation Group 0
    F0B17: Re-participation Group 7
    Specify the duration of simultaneous paging.
    (1)
    (2)Y=0
    95
    01-99: 4-396 sec. in 4 sec. increments
    If no data is set, the default setting is 32-36 
    seconds.
    CM41
    A
    END
    CM90,
    ~ ~
    ~ ~ 
    						
    							ND-46248 (E) CHAPTER 4
    Pag e 14 1
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    3.6.5 Group Call-2 Way Calling
    To provide the Group Call-2 Way Calling:
    DESCRIPTION DATA
    Assign the stations which belongs to each pag-
    ing group, and their number within the group. 
    A maximum of 9 stations can be paged simul-
    taneously except the conference leader.
    Note 1:Single line telephones, Multline
    Terminals and PS can be as-
    signed as the station within the
    group.
    A virtual-line cannot be as-
    signed.
    Note 2:A station can belong to multiple
    groups.
    (1)
    (2)YY=00-07: Simultaneous Paging Group 0-
    7
    00-15: Serial No. within the Group
    X-XXXX: Station No.
    Assign a Service Restriction Class to each sta-
    tion.
    (1)
    (2)YY=02
    X-XXXX: Station No.
    XX
     XX
    00-15 : Service Restriction 
    Class A
    Allow the Service Restriction Class A to page 
    the group.
    (1)
    (2)YYY=119
    00-15: Service Restriction Class A assigned 
    by CM12 YY=02
    0: Allowed
    Assign the access code of paging groups for 
    Group Call-2 Way Calling.
    Note:Even if an extension does not be-
    long to the conference group, the
    extension can page the confer-
    ence group.
    (1)
    (2)Y=0-3 (Tenant Group No.)
    X-XX: Access Code
    B20: Simultaneous Paging Group 0
    B27: Simultaneous Paging Group 7
    Assign a Group Call-2 Way Calling key of 
    each paging group to the Multiline Terminal, 
    if required.
    Note:Even if an extension does not be-
    long to the conference group, the
    extension can page the confer-
    ence group.
    (1)
    (2)Y=00
    X-XXXX: Primary Extension No. +  
    + key No.
    F0B20: Simultaneous Paging Group 0
    F0B27: Simultaneous Paging Group 7
    START
    CM56
    CM12
    CM20
    CM15
    END
    CM90
    ~ ~
    ,
    ~ ~ 
    						
    							CHAPTER 4 ND-46248 (E)
    Pag e 14 2
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    3.6.6 Multi-Line Operation-PS
    DESCRIPTION DATA
    Assign a PS station number to the virtual PS 
    number.(1)
    (2)Virtual PS No. (0001-0255)
    X-XXXX: Primary PS Station No. 
    Note
    X-XXXX: Sub-line PS Station No. Note
    Assign the sub-line PS number to each prima-
    ry PS station.
    (1)
    (2)YY=01
    X-XXXX: Primary PS Station No. 
    Note
    X-XXXX: Sub-line PS Station No. Note
    Assign PS-ID of the sub-line PS as “NONE”.
    (1)
    (2)YY=21
    X-XXXX: Sub-line PS Station No. 
    Note
    NONE
    Specify the terminal kind of the PS as “D
    term 
    PS II”.
    This data must be set to both the primary PS 
    station number and the sub-line PS station 
    number.
    (1)
    (2)YY=15
    X-XXXX: Primary PS Station No., Note
    Sub-line PS Station No. Note
    00: Dterm PS II
    Provide the Multi-Line function to the virtual 
    PS No. for the sub-line PS.
    (1)
    (2)YY=05
    X-XXXX: Virtual PS No.
    0: Provided (Sub-line station)
    Assign the virtual line/trunk data for the sub 
    line PS as same as the primary PS, by the de-
    scribed in the Section 3.4 and 3.5.Refer to the Section 3.4 and 3.5.
    Note:PS Station number is assigned by
    CM 1C.
    START
    CM1C
    CM1D
    END
    CM12
    CM10
    CM12
    CM13
    CM30
    CM35
    CM5A 
    						
    							ND-46248 (E) CHAPTER 4
    Pag e 14 3
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    To assign the PS station to the line key on the Dterm, assign the following data.
    DESCRIPTION DATA
    Assign a virtual PS station number to the key 
    number of the Dterm.
    A virtual PS number of PS sub-line can be as-
    signed to the key on the D
    term.
    (1)
    (2)YY=00
    Primary Extension No. +   + Key No.
    X-XXXX: Virtual PS Station No.
    CM90
    END START, 
    						
    							CHAPTER 4 ND-46248 (E)
    Page 143-1 Addendum-001
    Revision 2.1 MARCH, 1999
    SYSTEM DATA PROGRAMMING
    3.6.7 Number Sharing
    DESCRIPTION DATA
    Specify the combination of the main station 
    and the sub station, also the contrary 
    combination, as follows.
    1st data: Main station (D
    term My Line)
    2nd data: Sub station (PS)
    1st data: Sub station (PS)
    2nd data: Main station (D
    term My Line)
    Note:As the main station number, Dterm
    My Line number must be
    assigned.
    As the sub station number,
    following number must be
    assigned.
    • Integrated type/Adjunct type
    (CCIS):
    Virtual PS number assigned
    by CM10.
    •Adjunct type (LC-COT):
    PS station number assigned
    by CM30 YY=04.
    (1)
    (2)YY=16 (Assignment of the main station 
    and the sub station)
    X-XXXX: Main station (D
    term My Line)
    No./sub station (PS) No.
    X-XXXX: Sub station (PS) No./main
    station (D
    term My Line) No.
    Assign the Class of Service to required sta-
    tions.
    Note:For the Trunk Restriction Class
    (CM12 YY=01) and the Tenant
    Number (CM12 YY=04), the
    same data must be assigned to the
    sub station and the main station.
    (1)
    (2)YY=02 
    X-XXXX (Station No.)
    XX
    XX
    To the sub station (PS), specify the number 
    which is informed to calling/called party, 
    SMDR and MCI as the main station number.
    (1)
    (2)YYY=127
    Service Restriction Class A of sub station 
    (00-15)
    0: Main station number is informed
    Provide the capability of setting/cancelling the 
    Number Sharing from the sub station.
    (1)
    (2)YYY=128
    Service Restriction Class A of sub station 
    (00-15)
    0: To provide
    START
    CM12
    A
    CM15
    Service Restriction Class A
    (00-15) 
    						
    							ND-46248 (E) CHAPTER 4
    Addendum-001 Page 143-2
    MARCH, 1999 Revision 2.1
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Specify whether the sub station is controlled 
    the same as the main station, by a Message 
    Waiting lamp control signal sent from the 
    MC1.
    Note:This assignment is effective only
    when the system is an Integrated
    type.
    (1)
    (2)YYY=129
    Service Restriction Class A of Main station 
    (00-15)
    0: Main station and sub station are con-
    trolled.
    1 : Only main station is controlled.
    Provide the PS11 station(s) with Message 
    Waiting Service.
    Note:This assignment is only necessary
    if Data 0 (Main station and Sub
    station are controlled) is selected
    in CM15 YYY=129 for Service
    Restriction Class A of Main
    station.
    (1)
    (2)YY=03 
    X-XXXX: Virtual PS No.
    0: To be provided
    Provide the Number Sharing set/cancel key to 
    the main station (D
    term).
    (1)
    (2)YY=00
    My Line No. + + Key No.
    F0A94: Number Sharing Set/Cancel
    Assign the Access Code for setting or cancel-
    ling Number Sharing from the sub station 
    (PS).
    (1)
    (2)Y=0-3 (Tenant Group Number)
    X-XXX: Access Code
    A92: Set Number Sharing from the sub sta-
    tion
    A93: Cancel Number Sharing from the sub 
    station
    CM15
    A
    CM13
    END
    CM90
    CM20
    , 
    						
    							CHAPTER 4 ND-46248 (E)
    Page 144 Addendum-001
    Revision 2.1 MARCH, 1999
    SYSTEM DATA PROGRAMMING
    3.6.8 Voice Mail Indication
    DESCRIPTION DATA
    Provide PS stations with Message Waiting 
    service.
    The first data should be the virtual PS number.•
    (1)
    (2)YY=03
    X-XXXX: Virtual PS No.
    0: To be providedCM13
    END START 
    						
    							ND-46248 (E) CHAPTER 4
    Pag e 14 5
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    3.7 Multi-Site Roaming Data Assignment
    According to the following procedure, assign the system data for Roaming service.
    Confirming Network Numbering Plan
    Confirm whether the network adopts Open Numbering System or Closed Numbering System for the net-
    work numbering plan.
    Note:The System data stored in the memory of the DBM (AP00) card can be saved, loaded and verified from
    the MAT.
    To save; Memory Area No.: A, Memory Address: 00900-10870
    To load or verify; File Extension: DMA
    PREPARATION
    Confirming Network Numbering Plan
    (Open Numbering System/Closed Numbering System)
    START
    Numbering Plan Data Assignment
    (Open Numbering System/Closed Numbering System)
    Q931a Digital Trunk Assignment
    (for Home PBX and Visitor PBX)
    Roaming PS Data Assignment
    (for Home PBX and Visitor PBX)
    Home PS Data Assignment
    (for Home PBX)
    Visitor PS Data Assignment
    (for Visitor PBX)
    ENDSee this section.
    See Section 3.7.1.
    See Section 3.7.2.
    See Section 3.7.2 ~3.7.3.
    See Section 3.7.3.
    See Section 3.7.4. 
    						
    							CHAPTER 4 ND-46248 (E)
    Pag e 14 6
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    3.7.1 Network Numbering Plan Assignment
    DESCRIPTION DATA
    Assign an access code for LCR Group 0-3.
    For Closed Numbering System, assign the sec-
    ond data to A29 (LCR Group 3).
    (1)
    (2)Y=0-3 (Numbering Group 0-3)
    X-XXXX: Access Code
    A26: LCR Group 0
    A27: LCR Group 1
    A28: LCR Group 2
    A29: LCR Group 3
    Specify the number of digits and the first digit 
    for station number.
    (1)
    (2)Y=0-3 (Numbering Group 0-3)
    X: First Digit of Station No.
    801: 1 digit
    802: 2 digits
    803: 3 digits
    804: 4 digits
    Assign an Area Code Development Pattern 
    No. to each LCR Group. 
    For Closed Numbering System, assign the first 
    data to 3.
    (1)
    (2)YYY=A00
    0-3: LCR Group 0-3 
    0-7: Area Code Development Pattern 
    No. 0-7 
    Assign a Route Pattern No. to each area code 
    for the Area Code Development Pattern No. 
    assigned by CM8A YYY=A00.
    (1)
    (2)YYY=400-407 (Area Code Development 
    Pattern No. 0-7) 
    XX...XX (Area Code, Max. 8 digits) 
    000-063 (Route Pattern No. 00-63) 
    Assign an area code including LCR access 
    code assigned by CM20-A29.
    (1)
    (2)YYY=400-407 (Area Code Development 
    Pattern No. 0-7) 
    X-XXXXX (Area Code, 1-5 digits) 
    800 (Intra-Office Termination)
    801 (1-digit intra-office station) 
    802 (2-digit intra-office station) 
    803 (3-digit intra-office station)
    804 (4-digit intra-office station) 
    805 (5-digit intra-office station)
    START
    CM20
    CM8A
    A 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs Wcs System Manual