Home > NEC > Communications System > NEC Neax 2000 Ivs Wcs System Manual

NEC Neax 2000 Ivs Wcs System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs Wcs System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ND-46248 (E) CHAPTER 4
    Pag e 12 9
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Specify the Application of answer signal from 
    the distant office for outgoing connection to 
    the trunk route.
    (1)
    (2)YY=04
    Trunk Route No. (00-63)
    1 : Battery Reversal
    7 : Answer signal does not arrive from 
    C.O. Line (Answer timing shall be set by 
    CM41Y=0 Function No. 03)
    Specify the Application of release signal from 
    the distant office for an outgoing connection 
    of an incoming connection to the trunk route.
    (1)
    (2)YY=05
    Trunk Route No. (00-63)
    0 : Release signal does not arrive
    1 : Release signal arrives
    Note:In case of Adjunct Type1 (LC-
    COT), using a line card over
    the Main PBX is recommend-
    ed to provide the release sig-
    nal (i.e., momentarily, an open
    circuit).
    Assign the Sending of the dial pulse on an out-
    going call to the trunk route.
    (1)
    (2)YY=08
    Trunk Route No. (00-63)
    3 : Dial pulses are sent out
    Assign the Incoming Connection Signaling to 
    the trunk route.
    (1)
    (2)YY=09
    Trunk Route No. (00-63)
    15 : Ring Down (Loop Start C.O.)
    Assign the Sending of Hook Flash to outside 
    to the trunk route.
    (1)
    (2)YY=16
    Trunk Route No. (00-63)
    1 : Sending
    Assign the Sender Start Condition to the trunk 
    route.
    (1)
    (2)YY=20
    Trunk Route No. (00-63)
    15 : Timing Start
    CM35
    B
    A
    
    
    
    
    
     
    						
    							CHAPTER 4 ND-46248 (E)
    Pag e 13 0
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Specify the Sender Prepause Timing to the 
    trunk route.
    (1)
    (2)YY=21
    Trunk Route No. (00-63)
    00: 0 sec. 08: 6.0 sec.
    01: 0.5 sec. 09: 7.0 sec.
    02: 1.0 sec. 10: 8.0 sec.
    03: 1.5 sec. 11: 9.0 sec.
    04: 2.0 sec. 12: 10.0 sec.
    05: 2.5 sec. 13: 11.0 sec.
    06: 4.0 sec. 14: 12.0 sec.
    07: 5.0 sec. 15 : 3.0 sec.
    Note:To reduce the connecting time,
    shorten the prepause timing
    (i.e., second data=03 (1.5
    sec.))
    Specify the DP Inter-Digital Pause to the trunk 
    route.
    (1)
    (2)YY=23
    Trunk Route No. (00-63)
    0: 300 ms. 4: 700 ms.
    1: 400 ms. 5: 900 ms.
    2: 500 ms. 6: 1100 ms.
    3: 600 ms. 7 :  800 ms.
    Specify the DTMF-Inter-Digital Pause to the 
    trunk route.
    (1)
    (2)YY=24
    Trunk Route No. (00-63)
    0:  32 ms. 4: 160 ms.
    1: 64 ms. 5: 192 ms.
    2: 80 ms. 6: 240 ms.
    3: 96 ms. 7 :  128 ms.
    Note:To reduce the connecting time,
    it is recommended to shorten
    the DTMF inter-digital Pause
    timing (YY=24), i.e., second
    data=2 (80ms). YY=26, i.e.,
    second data= 0 (64ms)
    Assign the DP Make Ratio to the trunk route.
    (1)
    (2)YY=25
    Trunk Route No. (00-63)
    0 : 39% Make Ratio
    1 : 33% Make Ratio
    C
    CM35
    B
    
    
    
     
    						
    							ND-46248 (E) CHAPTER 4
    Pag e 13 1
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Assign the DTMF Signal Width to the trunk 
    route.
    (1)
    (2)YY=26
    Trunk Route No. (00-63)
    0 : 64 ms.
    1 : 128 ms.
    Note:To reduce the connecting time,
    it is recommended to shorten
    the DTMF inter-digital Pause
    timing (YY=24), i.e., second
    data=2 (80ms). YY=26, i.e.,
    second data=0 (64ms)
    Assign the Trunk Release by detection of re-
    versal of tip and ring to the trunk route.
    (1)
    (2)YY=39
    Trunk Route No. (00-63)
    0 : Not to be released
    1 : To be released
    CAUTION:Check the timing on Main PBX before making any change on timing function (after
    PBX).
    Specify the DP Sender Release Timing to the 
    trunk route.
    (1)
    (2)YY=45
    Trunk Route No. (00-63)
    0: 2 sec.
    1: 4 sec.
    2: 6 sec.
    3: 8 sec.
    4: 12 sec.
    5: 14 sec.
    6: 16 sec.
    7: 10 sec.
    Specify the DTMF Sender Release Timing to 
    the trunk route.
    (1)
    (2)YY=46
    Trunk Route No. (00-63)
    0: 2 sec.
    1: 4 sec.
    2: 6 sec.
    3: 8 sec.
    4: 12 sec.
    5: 14 sec.
    6: 16 sec.
    7: 10 sec.
    Specify the designated seizure of trunks on 
    each station basis.
    (1)
    (2)YY=98
    Trunk Route No. (00-63)
    0: Allowed
    CM35
    C
    D
    
    
    
     
    						
    							CHAPTER 4 ND-46248 (E)
    Pag e 13 2
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Specify the CDT card Terminating Impedance.
    (1)
    (2)YY= 100
    Trunk Route No. (00-63)
    0 : 600 
    Ω/complex BNW for Integrated 
    Type and Adjunct Type(2)
    2 : 600 
    Ω/600 
    Ω for Adjunct Type(1) 
    (LC-COT)
    Assign the trunk to be seized on each PS sta-
    tion basis.
    (1)
    (2)YY=16
    X-XXXX: PS Station No.
    D000-D255: Trunk No.
    Automatic Pause Entry Table
    Designate digits requiring automatic pause.
    (1)
    (2)Y=0
    Block Number (00-04)
    Dialed digits before automatic pause 
    (Exclusive of Access Code)
    X: 0-9, A (*), B (#)
    Provide automatic pause.
    (1)
    (2)Y=1
    00
    3 (To be provided)
    Timing automatic pause.
    (1)
    (2)Y=2
    00
    2 (1.5 sec.)
    CM88
    END
    CM12
    CM35
    D
     
    						
    							ND-46248 (E) CHAPTER 4
    Pag e 13 3
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    3.6 Service Feature Data Assignment
    3.6.1 Announcement Service
    Refer to Appendix A for the operating procedure.
    To provide the Announcement Service:
    DESCRIPTION DATA
    Assign a Digital Announcement Trunk Circuit 
    No. to the required LEN.
    Note:The Digital Announcement Trunk
    Circuit No. must be assigned to
    the first LEN (Level 0) and/or the
    third LEN (Level 2) of each LT
    slot.(1)
    (2)LEN (0000-0511)
    EB000-EB127: Digital Announcement 
    Trunk Circuit No.
    For PIM 0/1: EB000-EB031
    For PIM 2/3: EB032-EB063
    For PIM 4/5: EB064-EB095
    For PIM 6/7: EB096-EB127
    Assign a tenant No. to a PS station. (1)
    (2)YY=04
    X-XXXX: PS Station No.
    00 : Tenant 00
    1 : Tenant 01
    63: Tenant 63
    Specify whether PS Out of Cell/PS Power Off 
    are separated from No-Answer.
    Specify types of No-Answer Timer.
    Note:This data is effective only when
    CM08-086 is set to 0.(1)
    (2)
    (1)
    (2)086
    0: Separated
    1 : Not Separated (Handled as No-An-
    swer)
    085
    0 : No-Answer timer (CM41·Y=0-86)
    1 : No-Answer timer (CM41·Y=0-01)
    Specify the message reply timer for the An-
    nouncement Service when a PS does not an-
    swer.
    (1)
    (2)Y=0
    01
    01-30: 4-120 sec. in 4 sec. increments 
    Note:This data is effective only when
    CM08-085 and 086 are set to 1.If no data is set, the default setting is 32-36 
    seconds.
    Specify the message reply timer for the An-
    nouncement Service when a PS does not an-
    swer.
    (1)
    (2)Y=0
    86
    01-99: 4-396 sec. in 4 sec. increments
    Note:This data is effective only when
    CM08-085 and 086 are set to 0.If no data is set, the default setting is 36-40
    seconds
    START
    CM10
    CM12
    CM41
    CM08
    A
    INITIAL
    
    ~
    
     
    						
    							CHAPTER 4 ND-46248 (E)
    Pag e 13 4
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Specify the message reply timer for the An-
    nouncement Service when a PS is out of cell/PS 
    power is off.
    Note:This data is effective only when
    CM08-086 is set to 0.
    (1)
    (2)Y=0
    85
    01-99: 4-396 sec. in 4 sec. increments
    If no data is set, the default setting is 8-12 sec-
    onds.
    Specify the duration of message for the An-
    nouncement Service when a PS does not an-
    swer.
    (1)
    (2)Y=0
    75
    01-99: 4-396 sec. in 4 sec. increments
    If no data is set, the default setting is 116-120 
    seconds.
    Specify the duration of message for the An-
    nouncement Service when a PS is out of cell/PS 
    power is off.
    (1)
    (2)Y=0
    84
    01-99: 4-396 sec. in 4 sec. increments
    Note:This data is effective only when
    CM08-086 is set to 0.If no data is set, the default setting is 116-120 
    seconds.
    Provide the Announcement Service.
    (1)
    (2)Y=5
    00: PS No-Answer
    02: PS Out of Cell/PS Power Off
    0500: To be provided
    1500: Not to be provided
    NONE
     : Not to be provided
    Assign the function for each Digital Announce-
    ment Trunk.
    (1)
    (2)YY=00
    000-127: Digital Announcement Trunk 
    assigned by CM10 
    (EB000-EB127)
    1300-1363: PS No Answer Message Group 
    No. 00-63
    1500-1563: PS Power Off/Out of Cell 
    Message Group No. 00-63
    NONE : None
    Assign the message group for each tenant when 
    a PS does not answer.
    (1)
    (2)YY=10
    00-63: Tenant No.
    00-63: Message Group No.
    NONE : None
    Assign the message group for each tenant when 
    a PS is out off cell/PS power is off.
    (1)
    (2)YY=12
    00-63: Tenant No.
    00-63: Message Group No.
    NONE : None
    CM41
    CM48
    A
    END
    CM49
    
    
    
     
    						
    							ND-46248 (E) CHAPTER 4
    Pag e 13 5
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    To record/replay/delete a message from a station:
    There are two methods to record/replay/delete a message from a PS or a station, as mentioned below.
    1. To record/replay/delete a message from a station or a PS by dialling an access code assigned by CM20, do
    the following programming.
    This method is available for only the Integrated Type.
    DESCRIPTION DATA
    Assign the Class of Service for the 
    Announcement Service to a certain PS/station.
    
    (1)
    (2)CM12 YY=02
    (Service Restriction Class A)
    CM15 YY=33 
    (Digital Announcement Trunk Access: 
    Record/Replay/Delete)
    Service Restriction Class A (00-15)
    0/1 
    u: Restricted/Allowed
    Assign the access codes to record, replay, and 
    delete the message.
    (1)
    (2)Y=0-3 (Numbering Plan Group 0-3)
    X-XXX: Access Code
    A00: Record
    A01: Replay
    A02: Delete
    Refer to Appendix A for the operating procedure.
    CM12
    END
    START
    CM15
    CM20 
    						
    							CHAPTER 4 ND-46248 (E)
    Page 136 Addendum-001
    Revision 2.1 MARCH, 1999
    SYSTEM DATA PROGRAMMING
    2. To record/replay/delete a message from a PS by dialing “1”, “2”, “3”, do the following programming.
    This method is available for both the Integrated Type and the Adjunct Type.
    DESCRIPTION DATA
    Assign the Class of Service for the Announce-
    ment Service to a certain PS/station.
    Note:By this method, while a PS
    specified to “Allowed” to record/
    replay/delete a message by CM15
    YYY=110, the PS cannot
    originate a call. Specify to
    “Restricted” by CM15 YYY=110
    again after a message is
    completed to record/replay/
    delete.
    
    (1)
    (2)CM12 YY=02
    (Service Restriction Class A)
    CM15 YYY=110 
    (Digital Announcement Trunk Access: 
    Record/Replay/Delete)
    Service Restriction Class A (00-15)
    0/1 : Allowed/Restricted
    Refer to Appendix A for the operating procedure.
    CM12
    END START
    CM15
     
    						
    							ND-46248 (E) CHAPTER 4
    Addendum-001 Page 137
    MARCH, 1999 Revision 2.1
    SYSTEM DATA PROGRAMMING
    3.6.2 Call Forwarding-Not Available
    DESCRIPTION DATA
    Assign the destination VMS station for Call 
    Forwarding-Not Available.•
    (1)
    (2)YY=20
    00-63: Tenant No. of Virtual PS
    X-XXXX: VMS Station No.
    Assign the access code to set/cancel Call For-
    warding when the incoming call is not avail-
    able, and set the access code to replay the 
    message.
    Provide the PSII station(s) with Message 
    Waiting Service.
    Note:This assignment is only necessary
    if data 0 (Main Station and Sub
    Station are controlled) is selected
    in CM15 YYY=129 for Service
    Restriction Class A of Main sta-
    tion.
    (1)
    (2)
    
    (1)
    (2)Y=0-3 (Numbering Plan Group 0-3)
    X-XXX: Access Code
    A89: Call Forwarding-Not Available Set
    A90: Call Forwarding-Not Available 
    Cancel
    A91: Call Forwarding-Not Available 
    Replay
    YY=03
    X-XXXX: Virtual PS No.
    0: To be provided
    Specify whether confirmation of message 
    existence by Special Dial Tone is available or 
    not.
    If the second data is set to 0, the Special Dial 
    Tone is sent when a message exists.
    (1)
    (2)Y=2
    12 (Confirmation by Dial Tone)
    0:Available
    1 : Not available
    Specify that PS Out of Cell/PS Power Off is 
    separated from No-Answer.
    Set the Class of Service for the Call Forward-
    ing-Not Available to each PS station.(1)
    (2)
    
    
    (1)
    (2)086 : PS Out of Cell/PS Power Off
    0 : Separated
    CM12 YY=02 (Service Restriction Class 
    A)
    CM15 YYY=115 (Call Forwarding-Not 
    Av a i l a b l e )
    Service Restriction Class A for the Virtual 
    PS Station (00-15)
    0 : Restricted
    1 : Allowed
    CM12
    END START
    CM15
    CM20
    CM48
    CM51
    CM13
    CM08 
    						
    							CHAPTER 4 ND-46248 (E)
    Pag e 13 8
    Revision 2.0
    SYSTEM DATA PROGRAMMING
    3.6.3 Calling Name Display-PS
    Refer to the following manuals for the name display feature programming.
    Feature Programming Manual; Alphanumeric Display, Caller ID Class
    CCIS System Manual; Calling Name Display-CCIS
    PMS System Manual; Guest Name Display
    DESCRIPTION DATA
    Specify the terminal kind of the PS as “Dterm 
    PS II”.
    (1)
    (2)YY=15
    X-XXXX: PS Station No. (Assigned by 
    CM1C)
    00: D
    term PS II
    Specify the kind of the ZT as “D
    term PSII
    type ZT”.
    (1)
    (2)YY=19
    X-XXXX: ZT No.
    00: D
    term PS II Type ZT
    Assign a Service Restriction Class to each sta-
    tion.
    Note 1
    
    (1)
    (2)YY=02
    X-XXXX: PS Station No. (Assigned by 
    CMIC)
    XX XX
    00-15  : Service Restriction 
    Class A
    Provide Calling Name Display to PS
    (1)
    (2)YYY=123
    00-15 : Service Restriction Class A as-
    signed by CM 12 YY=02
    0 : Available
    1   : Not Available
    Note 1:The previous PS Dterm does not
    provide the Calling Name Dis-
    play feature; therefore, this data
    shuld be set to “1” Not Avail-
    able. Set data to “0” Available if
    providing service for the D
    term
    PS II.
    START
    CM1D
    CMAD
    END
    CM12
    CM15 
    						
    All NEC manuals Comments (0)