Home > NEC > Communications System > NEC Neax 2000 Ivs Wcs System Manual

NEC Neax 2000 Ivs Wcs System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs Wcs System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ND-46248 (E) CHAPTER 3
    Pag e 10 1
    Revision 2.0
    INSTALLATION
    Figure 3-53    Switch Settings on DBM Card
    RUN
    SW1
    WE
    L3
    SW1
    ON
    OFF
    SET THE KNOB TO MATCH THE
    AP NO. (04-15) TO BE SET BY
    CM05SENSE
    :POSITION TO BE SET 1 2 3 4
    RS3
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    MB
    UP
    L2
    L1
    L0
    RS1
    RS0 RS2
    SW0
    MB
    SENSE
    SW0
    ON12345678
    : POSITION TO BE SET.
    J16
    J16
    : POSITION TO BE SET RIGHT : MEMORY BACKUP ON 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 10 2
    Revision 2.0
    INSTALLATION
    STEP 2: Mount the DTI, DCH and DBM card in AP slots on PIM0-PIM7 as follows.
    2000 IVS1000 IVS
    DTI card: AP0-AP6 DTI card: AP0-AP4
    DCH card: AP0-AP8 DCH card: AP0-AP4
    DBM card: AP0-AP8 DBM card: AP0-AP4
    Small Platform System
    DTI card: AP0-AP3
    DCH card: AP0-AP5
    DBM card: AP0-AP5
    After mounting the card, set the SENS switch to match an unequipped AP number in CM05. And set
    the MB switch to down position to put the card in service. For details on mounting locations, refer to
    the Circuit Card Manual. 
    						
    							ND-46248 (E) CHAPTER 3Pag e 10 3
    Revision 2.0
    INSTALLATION
    5.3 Selection of PLO in MP Card
    STEP  1:  On  the  M P (PN-C P00 /C P00-B /CP03)  c ard,  set  t he  sw itch es as  s h ow n  in  Fig ure  3-5 4.
    Figure 3-54    Switch Settings on MP Card (1 of 3)
    RUN
    SW2
    ON
    OFF
    0: ON LINE MODE
    : POSITION TO BE SET
    1 
    2 
    3 
    4
    JP0
    SW3
    CLKIN JP0
    RS
    ON: KF MODE 
    OFF: PF/MF MODE (STANDARD SETTING FOR U.S.A.)
    SW1 
    SW2
    ATTENTIONContents 
    Static Sensitive
    Handling 
    Precautions Required
    PN-CP00
     WHEN USING THE INTERNAL PLO  WHEN USING THE PLO CARD
    SW2-2 SW2-3 SW2-2 SW2-3 OFF OFF : 1.5 MHz CLOCK OFF ONON OFF : 192 kHz CLOCK
    OFF ON : 2 MHz CLOCK ON ON : NOT USED WHEN NOT USING THE INTERNAL PLO 
    AND THE PLO CARD
    SW2-2 SW2-3 OFF OFF
    RIGHT: NORMAL  OPERATION
    : POSITION TO BE SET SW3 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 10 4
    Revision 2.0
    INSTALLATION
    Figure 3-54  Switch Settings on MP Card (2 of 3)
    SW3
    RUN
    SW1
    SW2
    CLKIN
    JP0
    0: ON LINE MODE
    JP0
    :  POSITION TO BE SET
      PN-CP00-B
     WHEN USING THE INTERNAL PLO WHEN USING THE PLO CARD
    SW2-2SW2-3 SW2-2SW2-3
    OFF OFF : 1.5 MHz CLOCK OFF ON
    ON OFF : 192 kHz CLOCK
    OFF ON : 2 MHz CLOCK
    ON ON : NOT USED
    WHEN THE INTERNAL PLO AND THE
    PLO CARD ARE NOT USED
    SW2-2 SW2-3
    OFF OFF
    SW2OFF
    ON 8
     
    7 
    6 
    5 
    4 
    3 
    2 
    1
    : POSITION TO 
      BE SET
    ON: KF MODE
    OFF: PF/MF MODE (STANDARD SETTING
    FOR U.S.A.)
    UP: NORMAL  OPERATION
    SW3ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							ND-46248 (E) CHAPTER 3
    Pag e 10 5
    Revision 2.0
    INSTALLATION
    Figure 3-54  Switch Settings on MP Card (3 of 3)
    STEP 2: Mount the MP card on the MP slot of PIM0.
    SW2SW2
    OFFON
    4 
    3 
    2 
    1 
     
    SW3: POSITION TO 
      BE SET
    :  POSITION TO BE SET
     0: ON LINE MODE
    ON: KF MODE
    OFF:  PF/MF MODE (STANDARD 
    SETTING FOR U.S.A.) 
     WHEN USING THE INTERNAL PLO
    SW2-2 SW2-3
    OFF OFF : 1.5 MHz CLOCK
    ON OFF : 192 kHz CLOCK
    OFF ON : 2 MHz CLOCK
    ON ON : NOT USED
     WHEN USING THE PLO CARD
    SW2-2 SW2-3
    OFF ON
    WHEN NOT USING THE INTERNAL PLO AND THE
    PLO CARD
    SW2-2 SW2-3
    OFF OFF
    ON : USING RS 1 PORT FOR BUILT-IN MODEM
    OFF : USING RS 1 PORT FOR RS-232C
    JP0
    JP1
    VR
    JP0
    UP: NORMAL OPERATION
    JP1
    UP:  USING INTERNAL HOLD TONE
    DOWN:  USING EXTERNAL HOLD TONE SOURCE
    SW3
    VR
    20
    0
     0
      PN-CP03
    VARIABLE RESISTER 
    FOR EXTERNAL HOLD 
    TONE SOURCE
    (0-20KΩ
     - CLOCKWISE)
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 ND-46248 (E) 
    Pag e 10 6
    Revision 2.0
    INSTALLATION5.4 Mounting PLO Card
    STEP  1:  On  the  PLO (PN -CK00)  ca rd,  se t t h e sw it c hes  as  sh ow n  in  Figu re 3 -55 .
    Figure 3-55    Switch Settings on PLO Card
    STEP 2: On the MP card, set the SW2-2 to OFF and SW2-3 to ON. 
    STEP 3: Mount the PLO card in an AP slot on PIM0.
    2000 IVS: AP0-AP8
     Small Platform System: AP0-AP5
     1000 IVS: AP0-AP4
    After mounting the card, set the MB switch to down position to put the card in service.
    MB
    SW
    SYNCPLO0 
    PLO1
    OFF
    ON
    8  
    7  
    6  
    5 
    4 
    3 
    2 
    1
    SW0 MB
    : POSITION TO  
      BE SET
    UP
    ALM
    DRFT
    ATTENTIONContents 
    Static Sensitive
    Handling 
    Precautions Required 
    						
    							ND-46248 (E) CHAPTER 3Pag e 10 7
    Revision 2.0
    INSTALLATION
    5.5 Cable Connection via MDF for DTI
    Co nne ct  the  ca b le  to a  CSU via  t h e MDF as  sh ow n  in  Figu re 3 -56 .
    F igu re  3-57  sh ow s the  L T C  con nec tor  co rr e sp onds  with  the AP  s lot s, a n d DTI  pin  a ss ignment  f o r  ea ch AP
    s lo t, and  F igu re 3 -58  sh ow s an  e x ample  o f t h e ca ble  c onn ect ion wh en the  DTI  ca rd is  mo unt ed in  the AP0
    slot of PIM0 on the NEAX2000 IVS.
    Figure 3-56    Cable Connection via MDF
    CSU
    MDF
    TWISTED-PAIR 
    CABLE
    BWB
    PBX 
    (PIM0 - PIM7)
    MAX. 200 m (655 ft.)
    LTC1/LTC2 CONNECTOR 
    (SEE FIGURES 3-57 AND 3-58.)
    DTI
    Note:The CSU must be installed to interface with the network, and must be installed on the premises 
    where the PBX is. 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 10 8
    Revision 2.0
    INSTALLATION
    Figure 3-57    Location of AP Slots and LTC Connectors for DTI (1 of 3)
    50 25 50 25
    49 24
    LT11/AP149 24
    48 23 48 23
    47 TB 22 TA 47 22
    46 RB 21 RA 46 21
    45 20
    LT10/AP045 20
    AP6 44 19 44 19
    43 TB 18 TA 43 TB 18 TA
    42 RB 17 RA 42 RB 17 RA
    41 16
    LT0941 16
    LT15/AP5 40 15 40 15
    39 14 39 TB 14 TA
    38 13 38 RB 13 RA
    37 12
    LT0837 12
    LT14/AP4 36 11 36 11
    35 10 35 TB 10 TA
    34 09 34 RB 09 RA
    33 08
    LT0733 08
    LT13/AP3 32 07 32 07
    31 06 31 TB 06 TA
    30 05 30 RB 05 RA
    29 04
    LT0629 04
    LT12/AP2 28 03 28 03
    27 02 27 TB 02 TA
    26 01 26 RB 01 RA
    LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
    LT14/AP4
    LT13/AP3
    LT12/AP2
    LT11/AP1
    LT00 LT01 LT02 LT09
    LT04 LT08
    LT07
    LT03 LT06
    LT05 LT10/AP0
    LTC0 LTC2LTC1 PIM
    LTC1 LTC2   NEAX2000 IVS 
    						
    							ND-46248 (E) CHAPTER 3
    Pag e 10 9
    Revision 2.0
    INSTALLATION
    Figure 3-57  Location of AP Slots and LTC Connectors for DTI (2 of 3)
    AP5MP
    LT10/AP4
    LT09/AP3
    LT08/AP2
    LT07/AP1
    LT00 LT01 LT02 LT04
    LT03 LT06/AP0
    LTC0 LTC2LTC1 PIM
    50 25
    49 24
    LT09/AP3 48 23
    47 TB 22 TA
    46 RB 21 RA
    45 20
    LT08/AP2 44 19
    43 TB 18 TA
    42 RB 17 RA
    41 16
    LT07/AP1 40 15
    39 14
    38 13
    37 12
    36 11
    35 TB 10 TA
    34 RB 09 RA
    33 08
    LT06/AP0 32 07
    31 06
    30 05
    29 04
    28 03
    27 TB 02 TA
    26 RB 01 RA
    LTC2
    Note:When mounting the Line/Trunk circuit card with 6 or 8 circuits into the LT08 slot, the LT09 slot
    cannot be used.
      Small Platform System 
    						
    							CHAPTER 3 ND-46248 (E)
    Pag e 11 0
    Revision 2.0
    INSTALLATION
    Figure 3-57  Location of AP Slots and LTC Connectors for DTI (3 of 3)
    MP
    LT08/AP4
    LT07/AP3
    LT06/AP2
    LT05/AP1
    LT00 LT01 LT02
    LT03 LT04/AP0
    LTC0LTC1
    50 25
    49 24
    LT08/AP4 48 23
    47 22
    46 21
    45 20
    44 19
    43 TB 18 TA
    42 RB 17 RA
    41 16
    LT06/LT07/AP3 40 15
    39 TB 14 TA
    38 RB 13 RA
    37 12
    LT06/AP2 36 11
    35 TB 10 TA
    34 RB 09 RA
    33 08
    LT04/LT05/AP1 32 07
    31 TB 06 TA
    30 RB 05 RA
    29 04
    LT04/AP0 28 03
    27 TB 02 TA
    26 RB 01 RA
    LTC1   NEAX1000 IVS
    PIM
    Note: When mounting the Line/Trunk circuit
    card with 6 or 8 circuits into the LT04
    slot or LT06 slot, the LT05 slot or LT07
    slot cannot be used. 
    						
    All NEC manuals Comments (0)