1-45 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513 Switch Table 1-21 Catalyst 6513 Switch Features Feature Description Chassis Thirteen horizontal slots. Slots are numbered from (1) top to (13) bottom. Power supplies Supports one or two power supplies. The following power supplies are supported: –WS-CAC-2500W (2500 W AC-input power supply) –WS-CDC-2500W (2500 W DC-input power supply) –WS-CAC-3000W (3000 W AC-input power supply) –WS-CAC-4000W-US (4000 W AC-input power supply) –WS-CAC-4000W-INT (4000 W AC-input power supply) –PWR-4000-DC (4000 W DC-input power supply) –WS-CAC-6000W (6000 W AC-input power supply) –WS-CAC-8700W-E (8700 W AC-input power supply) NoteFor information and specifications for each of the supported power supplies, refer to Appendix A, “Power Supply Specifications,” in the Catalyst 6500 Series Switches Installation Guide. The 8700 W AC-input power supply is limited to 6000 W when it is installed in a Catalyst 6513 switch chassis. Installed power supplies can be of different ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or nonredundant mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. You must install a 2500 W or higher capacity power supply when using the Supervisor Engine 32 or the Supervisor Engine 720 and the high-speed fan tray.
1-46 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513 Switch Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE. –Supervisor Engine 2 is installed in slot 1 and slot 2. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE are installed in slot 7 and slot 8. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE require that you install the high-speed fan tray (WS-C6K-13SLT-FAN2) be installed in the chassis. You must also install a 2500 W or higher capacity power supply in the chassis to power the high-speed fan tray. –Supervisor Engine 720 and Supervisor Engine 720-10GE have built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported by Supervisor Engine 720 and Supervisor Engine 720-10GE and cannot be installed in the same chassis. –Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules ((WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on all redundant supervisor engine models when they are in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Table 1-21 Catalyst 6513 Switch Features (continued) Feature Description
1-47 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513 Switch ModulesChassis supports up to 12 Catalyst 6500 series modules. WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be installed in slot 7 or slot 8. WS-X6748-SFP, WS-X6748-GE-TX, and WS-X6704-10GE modules are not supported in slots 2–8; they are supported in slots 9–13. –Slots 1–8 support a single fabric channel; slots 9–13 support dual fabric channels. Some Catalyst 6500 series modules: –Are not supported –Require that you install a Supervisor Engine 720 –Have chassis slot restrictions –Require a specific software release level NoteCheck your software release notes for specific information on module support and restrictions. Table 1-21 Catalyst 6513 Switch Features (continued) Feature Description
1-48 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513 Switch Table 1-22 Catalyst 6513 Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storage–4° to 149°F (–20° to 65°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 10% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m) Physical Characteristics Dimensions (H x W x D)33.3 x 17.2 x 18.1 in. (84.6 x 43.7 x 46.0 cm). Chassis requires 20 RU. Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Weight Chassis fully configured with 2 supervisor engines, 11 switching modules, and 2 power supplies: 280 lb (127 kg). Airflow WS-C6K-13SLOT-FAN (standard fan tray)—641 CFM WS-C6K-13SLT-FAN2 (optional high-speed fan tray)—1090 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side.
1-49 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513-E Switch Catalyst 6513-E Switch The Catalyst 6513-E switch is an enhanced version of the Catalyst 6513 chassis. Figure 1-15 shows a front view of the chassis. Table 1-23 provides a description of the major switch features. Table 1-24 lists the specifications of the Catalyst 6513-E switch chassis. Figure 1-15 Catalyst 6513-E Switch INPUT OKFA N OKOUTPUT FAIL o INPUT OKFA N OKOUTPUT FA I L o 208620 Power supply 1Power supply 2 (redundant) 8 PORT GIGABIT ETHERNETWS-X64081LINKSTATUS2 3 45 6 7 8LINKLINKLINKLINKLINKLINKLINK 24 PORT 100FXWS-X6224STATUS 24 PORT 100FXWS-X6224STATUS 24 PORT 100FXWS-X6224STATUS 24 PORT 100FXWS-X6224STATUS 1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK 1 2 3 4 5 6 7 8 9 10 11 12 13 WS-SUP32-GE-3BS TAT U S SYSTEM ACTIVE PWR MGMT RESETCATALYST 6500 SUPERVISOR ENGINE 32CONSOLE EJECTDISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PORT 7PORT 8PORT 9 USB 2.0LINK LINK LINK LINK LINK LINK LINK LINK LINKWS-SUP32-GE-3BSTATUS SYSTEM ACTIVE PWR MGMT RESETCATALYST 6500 SUPERVISOR ENGINE 32CONSOLE EJECTDISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PORT 7PORT 8PORT 9 USB 2.0LINK LINK LINK LINK LINK LINK LINK LINK LINK W S-C 6513-E Switching modules Switching modules Fan assembly (accessible from rear of chassis) Supervisor engine Redundant supervisor engine
1-50 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513-E Switch Table 1-23 Catalyst 6513-E Switch Features Feature Description Chassis Thirteen horizontal slots. Slots are numbered from (1) top to (13) bottom. Power supplies Supports one or two power supplies. The following power supplies are supported: –WS-CDC-2500W (2500 W DC-input power supply) –WS-CAC-3000W (3000 W AC-input power supply) –WS-CAC-4000W-US (4000 W AC-input power supply) –WS-CAC-4000W-INT (4000 W AC-input power supply) –PWR-4000-DC (4000 W DC-input power supply) –WS-CAC-6000W (6000 W AC-input power supply) –PWR-6000-DC (6000 W DC-input power supply) –WS-CAC-8700W-E (8700 W AC-input power supply) NoteFor information and specifications for each of the supported power supplies, refer to Appendix A, “Power Supply Specifications,” in the Catalyst 6500 Series Switches Installation Guide. Installed power supplies can be of different ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or nonredundant mode. Supervisor Engine 2T requires a 3000 W or greater power supply to operate. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated.
1-51 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513-E Switch Supervisor enginesSupports Supervisor Engine 32, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T. –Supervisor Engine 32, Supervisor Engine 720, and Supervisor Engine 720-10GE are installed in slot 7 and slot 8. –Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have built-in switching fabric; Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported. –Supervisor Engine 32 does not support the Switch Fabric Modules ((WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on all redundant supervisor engine models when they are in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Table 1-23 Catalyst 6513-E Switch Features (continued) Feature Description
1-52 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513-E Switch ModulesChassis supports up to 12 Catalyst 6500 series modules. Some Catalyst 6500 series modules: –Are not supported –Require that you install a specific supervisor engine –Have chassis slot restrictions –Require a specific software release level NoteCheck your software release notes for specific information on module support and restrictions. Table 1-24 Catalyst 6513-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storage–4° to 149°F (–20° to 65°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 10% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m) Table 1-23 Catalyst 6513-E Switch Features (continued) Feature Description
1-53 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513-E Switch Physical Characteristics Dimensions (H x W x D)33.3 x 17.2 x 18.1 in. (84.6 x 43.7 x 46.0 cm). Chassis requires 20 RU. Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Weight Chassis fully configured with 2 supervisor engines, 11 switching modules, and 2 power supplies: 280 lb (127 kg). Airflow WS-C6513-E-FAN—1755 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. Table 1-24 Catalyst 6513-E Switch Specifications (continued) Item Specification
1-54 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6513-E Switch