2-31 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-19 WS-X6148E-GE-45AT Ethernet Modules Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.65 x 14.4 x 16 in. (4.2 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 11 lb (5 kg) Power and heat numbers Module current—2.5 A Module power—105.0 W AC-input power—131.25 W AC heat dissipation—448.22 BTU/hour DC-input power—141.13 W DC heat dissipation—481.96 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
2-32 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6148X2-RJ-45 and WS-X6148X2-45AF Ethernet Modules The WS-X6148X2-RJ-45 and the WS-X6148X2-45AF Ethernet modules, listed in Table 2-20, provide 96 10/100-Mbps full- or half-duplex ports. (See Figure 2-9.) The WS-X6148X2-RJ-45 and the WS-X6148X2-RJ-45AF modules are shipped with a 96-port splitter panel (WS-F6K-48X2-SPLTR). (See Figure 2-10.) Figure 2-9 WS-X6148X2-RJ-45 Ethernet Module Front Panel Figure 2-10 WS-F6K-48X2-SPLTR Splitter Panel Table 2-21 lists the features for the modules, and Table 2-22 lists the physical and environmental specifications for the module. NoteWith the IEEE 802.3af PoE daughter card installed, the WS-X6148X2-RJ-45 module can support up to 48 Class 3 (15.4 W) devices per module when operating as a 48-port module or up to 96 Class 2 (7 W) devices per module when operating as a 96-port module. Table 2-20 WS-X6148X2-RJ-45 and the WS-X6148X2-45AF Ethernet Modules Module Description WS-X6148X2-RJ-45 Base module without daughter cards installed. WS-X6148X2-45AF Base module equipped with a factory-installed IEEE 802.3af PoE daughter card (WS-F6K-FE48X2-AF=). 184593 1 2 49 50 CATALYST 184594
2-33 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-21 WS-X6148X2-RJ-45 and WS-X6148X2-45AF Ethernet Modules Features Feature Description Ports per module 48 ports, but scalable to 96 ports with the use of the supplied splitter panel (both modules) Each connector supports two ports. Ports are numbered (left to right): –Top row, odd numbered ports 1/49 through 47/95. –Bottom row, even numbered ports 2/50 through 48/96. Port connector type RJ-45 (both modules) RJ-45 (splitter panel) Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable (both modules) Buffer size 1.116 MB per port (both modules) QoS Number of egress queues: 4 Number of ingress queues: 2 Number of thresholds per egress queue: 1 Number of thresholds per ingress queue: 0 Maximum frame size Up to 9216 bytes per frame (both modules) Module oversubscription rate N/A Supervisor engine support Supported on the following supervisor engines: Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine 720-10GE Software support With Supervisor Engine 2—Not supported with the 12.1E Release With Supervisor Engine 32—12.2(18)SXF3 With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720—12.2(18)SXF3 With Supervisor Engine 720-10GE—12.2(33)SXH Catalyst OS—8.3(3) Queues per port Both modules: Tx—1p3q1t Rx—1p1q0t
2-34 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Chassis/slot restrictions No chassis or slot restrictions; the module can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis. Bus connection Single connection into the 32-Gbps shared bus (both modules) Module upgrades available PoE support WS-X6148X2-RJ-45—Field upgradeable to both Cisco prestandard and IEEE 802.3af with the WS-F6K-FE48X2-AF= PoE daughter card. NoteWith the IEEE 802.3af PoE daughter card installed, the WS-X6148X2-RJ-45 module can support up to 48 Class 3 (15.4 W) devices per module when operating as a 48-port module or up to 96 Class 2 (7 W) devices per module when operating as a 96-port module. See the Cisco Catalyst 6500 Series Power over Ethernet Daughter Cards Field-Upgrade Installation Note for field upgrade procedures. See Appendix A for further information on the PoE daughter cards. Distributed forwarding supportNot supported. Pluggable transceivers supportNot supported. Table 2-21 WS-X6148X2-RJ-45 and WS-X6148X2-45AF Ethernet Modules Features (continued) Feature Description
2-35 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules TDR support Not supported Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. Table 2-21 WS-X6148X2-RJ-45 and WS-X6148X2-45AF Ethernet Modules Features (continued) Feature Description
2-36 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-22 WS-X6148X2-RJ-45 Physical and Environmental Specifications Item Specification Dimensions (H x W x D) Module—1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Splitter panel—3.5 x 19 x 1.25 in. (8.9 x 48.26 x 3.18 cm). Occupies 2 RUs in the rack. Weight WS-X6148X2-RJ-45 (base module)—7.2 lb (3.26 kg) Splitter panel—5.2 lb (2.36 kg) Power and heat numbers WS-X6148X2-RJ-45 (base module) –Module current—2.65 A –Module power—111.30 W –AC-input power—139.13 W –AC heat dissipation—475.11 BTU/hour –DC-input power—149.60 W –DC heat dissipation—510.87 BTU/hour WS-X6148X2-45AF (base module + PoE daughter card) –Module current—3.07 A –Module power—128.94 W –AC-input power—161.18 W –AC heat dissipation—550.41 BTU/hour –DC-input power—173.31 W –DC heat dissipation—591.84 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
2-37 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6196-RJ-21 and WS-X6196-21AF Ethernet Modules The WS-X6196-RJ-21 and the WS-X6196-21AF Ethernet modules, provide 96 10/100-Mbps full- or half-duplex ports. (See Table 2-23.) Figure 2-11 shows the module front panel. Figure 2-11 WS-X6196-RJ-21 Switching Module Front Panel Table 2-24 lists the module features, and Table 2-25 lists the module physical and environmental specifications. NoteWith the PoE daughter card installed, the WS-X6196-RJ-21 module can support 96 Class 2 (7 W) devices or 62 Class 3 (15.4 W) devices per module. Table 2-23 WS-X6196-RJ-21 Modules Module Description WS-X6196-RJ-21 Base module without daughter cards installed. WS-X6196-21AF Base module equipped with a factory-installed IEEE 802.3af PoE daughter card (WS-F6K-GE48-AF). WS-X6196-RJ-21 8X12 PORT10/100 BASE TETHERNET SWITCHING MODULESTATUS 1 49 2 50 3 51 4 52 5 53 6 54 7 55 8 56 9 57 10 58 11 59 12 60 13 61 14 62 15 63 16 64 17 65 18 66 19 67 20 68 21 69 22 70 23 71 24 72 25 73 26 74 27 75 28 76 29 77 30 78 31 79 32 80 33 81 34 82 35 83 36 84 37 85 38 86 39 87 40 88 41 89 42 90 43 91 44 92 45 93 46 94 47 95 48INLINE POWER96 1 6012 4913 7224 6125 8436 7337 9648 85 184595 Table 2-24 WS-X6196-RJ-21 and WS-X6196-21AF Ethernet Modules Features Feature Description Ports per module 96 ports (both modules). Ports are numbered (left to right) –Top row of connectors—First connector, ports 1–12; second connector, ports 13–24; third connector, ports 25–36; fourth connector, ports 37–48. –Bottom row of connectors—First connector, ports 60–49; second connector, ports 72–61; third connector, ports 73–84; fourth connector, ports 85–96. NoteThe bottom row of four RJ-21 connectors are inverted. The highest port number for a bottom row connector appears on the left side of the connector and the connector’s lowest port number appears on the right side. Port connector type RJ-21 (both modules) Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable (both modules) Buffer size 1.116 MB per port (both modules)
2-38 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules QoSNumber of egress queues: 4 Number of ingress queues: 2 Number of thresholds per egress queue: 1 Number of thresholds per ingress queue: 0 Maximum frame size Up to 9216 bytes (both modules) Module oversubscription rate N/A Supervisor engine support Supported on the following supervisor engines: Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine 720-10GE Software support With Supervisor Engine 2—Not supported with Release 12.1E With Supervisor Engine 32—12.2(18)SXF3 With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720—12.2(18)SXF3 With Supervisor Engine 720-10GE—12.2(33)SXH Catalyst OS Release—8.2.1 Queues per port Both modules: Tx—1p3q1t Rx—1p1q0t Chassis/slot restrictions No chassis or slot restrictions; the module can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis. Bus connection 32-Gbps shared bus (both modules) Module upgrades available PoE support WS-X6196-RJ-21—Field upgradeable to both Cisco prestandard and IEEE 802.3af with the WS-F6K-FE48X2-AF= PoE daughter card. NoteWith the PoE daughter card installed, the WS-X6196-RJ-21 module can support 96 Class 2 (7 W) devices or 62 Class 3 (15.4 W) devices per module. WS-X6196-21AF—Shipped with a WS-F6K-FE48X2-AF PoE daughter card installed. See the Cisco Catalyst 6500 Series Power over Ethernet Daughter Cards Field-Upgrade Installation Note for field upgrade procedures. See Appendix A for further information on the PoE daughter cards. Distributed forwarding supportNot supported. Table 2-24 WS-X6196-RJ-21 and WS-X6196-21AF Ethernet Modules Features (continued) Feature Description
2-39 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Pluggable transceivers supportNot supported. TDR support Not supported. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. Table 2-24 WS-X6196-RJ-21 and WS-X6196-21AF Ethernet Modules Features (continued) Feature Description
2-40 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-25 WS-X6196-RJ-21 and WS-X6196-21AF Ethernet Modules Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight WS-X6196-RJ-21—7.8 lb (3.54 kg) WS-X6196-21AF—11.2 lb (5.08 kg) Power and heat numbers WS-X6196-RJ-21 (base module) –Module current—2.74 A –Module power—115.08 W –AC-input power—143.85 W –AC heat dissipation—491.25 BTU/hour –DC-input power—154.68 W –DC heat dissipation—528.22 BTU/hour WS-X6196-21AF (base module + PoE daughter card) –Module current—3.16 A –Module power—132.72 W –AC-input power—165.90 W –AC heat dissipation—566.55 BTU/hour –DC-input power—178.39 W –DC heat dissipation—609.19 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)