2-51 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Supervisor engine support Supported on the following supervisor engines: Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine 720-10GE Software support With Supervisor Engine 2—12.1(19)E1 With Supervisor Engine 32—12.2(18)SXF With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720 (without either the WS-F6K-GE48-AF or the WS-F6K-48-AF daughter cards)—12.2(17a)SX With Supervisor Engine 720 (with either the WS-F6K-GE48-AF or the WS-F6K-48-AF daughter cards)—12.2(17d)SXB With Supervisor Engine720-10GE—12.2(33)SXH Queues per port Tx—1p2q2t (per 8 ports) Rx—1p2t (per 8 ports) Chassis/slot restrictions No chassis or slot restrictions; the module can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis (all variants). Bus connection 32-Gbps shared bus (all variants) Module upgrades available PoE support WS-X6548-GE-TX—Field-upgradeable to Cisco prestandard only by installing the WS-F6K-VPWR-GE= daughter card or both Cisco prestandard and IEEE 802.3af by installing the WS-F6K-GE48-AF= daughter card. NoteRefer to the Cisco Catalyst 6500 Series Power over Ethernet Daughter Cards Field-Upgrade Installation Note for field upgrade procedures. Distributed forwarding supportNot supported. Pluggable transceivers supportNot supported. Table 2-34 WS-X6548-GE-TX Modules Features (continued) Feature Description
2-52 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules TDR support All module variants support TDR. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. Table 2-34 WS-X6548-GE-TX Modules Features (continued) Feature Description
2-53 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-35 WS-X6548-GE-TX and Variants Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight Base module—7.2 lb (3.3 kg) Power and heat numbers WS-X6548-GE-TX (base module) –Module current—2.98 A –Module power—125.16 W –AC-input power—156.45 W –AC heat dissipation—534.28 BTU/hour –DC-input power—168.23 W –DC heat dissipation—574.49 BTU/hour WS-X6548-GE-45AF (base module + PoE daughter card) –Module current—3.16 A –Module power—132.72 W –AC-input power—165.90 W –AC heat dissipation—566.55 BTU/hour –DC-input power—178.39 W –DC heat dissipation—609.19 BTU/hour WS-X6548V-GE-TX (base module + PoE daughter card) –Module current—3.40 A –Module power—142.80 W –AC-input power—178.50 W –AC heat dissipation—609.58 BTU/hour –DC-input power—191.94 W –DC heat dissipation—655.46 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
2-54 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6548-RJ-21 Ethernet Module The WS-X6548-RJ-21 Ethernet module provides 48 10/100-Mbps full- or half-duplex ports. (See Figure 2-16.) Table 2-36 lists the features and description of the module, and Table 2-37 lists the physical and environmental specifications for the module. Figure 2-16 WS-X6548-RJ-21 Ethernet Module Front Panel Table 2-36 WS-X6548-RJ-21 Ethernet Module Features Feature Description Ports per module 48 ports. Ports are numbered (left to right): –First connector, ports 1–12; second connector, ports 13–24; third connector, ports 25–32; fourth connector, 33–48. Bottom row, even numbers 2 through 48. 1 port group Port ranges per port group: 1–48 Port connector type RJ-21 (12 ports per connector) Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable Buffer size 1.116 MB per port QoS Number of egress queues: 4 Number of ingress queues: 2 Number of thresholds per egress queue: 1 Number of thresholds per ingress queue: 0 Maximum frame size Up to 1518 bytes per frame. Module oversubscription rate N/A Supervisor engine support Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine 720-10GE Software support With Supervisor Engine 2—12.1(8a)E With Supervisor Engine 32—12.2(18)SXF With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720—12.2(14)SX With Supervisor Engine 720-10GE—12.2(33)SXH 6367248 PORT 10/100 BASE-T ETHERNETSWITCHING MODULE WS-X6548-RJ21 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748 13-241-1225-3637-48 STATUS
2-55 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Queues per portTx—1p3q1t Rx—1p1q0t Chassis/slot restrictions No chassis or slot restrictions; the module can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis. Bus connection 32-Gbps shared bus Module upgrades available PoE support Not available. Distributed forwarding supportCan be field-upgraded with either the WS-F6K-DFC, WS-F6K-DFC3B, or WS-F6K-DFC3BXL daughter cards. See the Catalyst 6500 Series DFC, DFC3A, DFC3B, and DFC3BXL Installation Note for additional information and field upgrade procedures. See Appendix A for additional information on the DFC daughter cards. Pluggable transceivers supportNot supported. TDR support Not supported. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing1. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. 1. Verify that all LINK LEDs are functioning. Table 2-36 WS-X6548-RJ-21 Ethernet Module Features (continued) Feature Description
2-56 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-37 WS-X6548-RJ-21 Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 7.6 lb (3.45 kg) Power and heat numbers Base module –Module current—2.90 A –Module power—121.80 W –AC-input power—152.25 W –AC heat dissipation—519.93 BTU/hour –DC-input power—163.71 W –DC heat dissipation—559.07 BTU/hour Base module + DFC3A daughter card –Module current—5.47 A –Module power—229.74 W –AC-input power—287.18 W –AC heat dissipation—980.70 BTU/hour –DC-input power—308.79 W –DC heat dissipation—1054.52 BTU/hour Base module + DFC3B daughter card –Module current—4.57 A –Module power—191.94 W –AC-input power—239.93 W –AC heat dissipation—819.34 BTU/hour –DC-input power—257.98 W –DC heat dissipation—881.01 BTU/hour Base module + DFC3BXL daughter card –Module current—4.37 A –Module power—183.54 W –AC-input power—229.43 W –AC heat dissipation—783.49 BTU/hour –DC-input power—246.69 W –DC heat dissipation—842.46 BTU/hour
2-57 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6548-RJ-45 Ethernet Module The WS-X6548-RJ-45 Ethernet module provides 48 10/100-Mbps full- or half-duplex ports. (See Figure 2-17.) Table 2-38 lists the features and descriptions of the module, and Table 2-39 lists the physical and environmental specifications for the module. Figure 2-17 WS-X6548-RJ-45 Switching Module Front Panel Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Table 2-37 WS-X6548-RJ-21 Physical and Environmental Specifications (continued) Item Specification Table 2-38 WS-X6548-RJ-45 Features Feature Description Ports per module 48 ports. Ports are numbered (left to right): –Top row, odd numbered ports 1–47. –Bottom row, even numbered ports 2–48. 1 port group Port ranges per port group: 1–48 Port connector type RJ-45 Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable Buffer size 1.116 MB per port QoS Number of egress queues: 4 Number of ingress queues: 2 Number of thresholds per egress queue: 1 Number of thresholds per ingress queue: 0 Maximum frame size Up to 1518 bytes per frame Module oversubscription rate N/A 6367348 PORT 10/100 BASE-T ETHERNETSWITCHING MODULE WS-X6548 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748 PHONESTATUS 1 211 1213 1435 3637 3847 48 23 2425 26
2-58 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Supervisor engine support Supported on the following supervisor engines: Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine 720-10GE NoteCheck your release notes for specific information on the software release required to support the supervisor engines. Software support With Supervisor Engine 2—12.1(8a)E With Supervisor Engine 32—12.2(18)SXF With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720—12.2(14)SX With Supervisor Engine 720-10GE—12.2(33)SXH Queues per port Tx—1p3q1t Rx—1p1q Chassis/slot restrictions No chassis or slot restrictions; the module can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis. Bus connection One 8-Gbps fabric connection and 32-Gbps shared bus Module upgrades available PoE support Not supported. Distributed forwarding supportCan be field-upgraded with either the WS-F6K-DFC, WS-F6K-DFC3B, or WS-F6K-DFC3BXL daughter cards. See the Catalyst 6500 Series DFC, DFC3A, DFC3B, and DFC3BXL Installation Note for additional information and field upgrade procedures. See Appendix A for additional information on the DFC daughter cards. Pluggable transceivers supportNot supported. Table 2-38 WS-X6548-RJ-45 Features (continued) Feature Description
2-59 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules TDR support Not supported. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing1. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. 1. Verify that all LINK LEDs are functioning. Table 2-39 WS-X6548-RJ-45 Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 7.6 lb (3.45 kg) Table 2-38 WS-X6548-RJ-45 Features (continued) Feature Description
2-60 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Power and heat numbersBase module –Module current—2.90 A –Module power—121.80 W –AC-input power—152.25 W –AC heat dissipation—519.93 BTU/hour –DC-input power—163.71 W –DC heat dissipation—559.07 BTU/hour Base module + DFC3A daughter card –Module current—5.47 A –Module power—229.74 W –AC-input power—287.18 W –AC heat dissipation—980.70 BTU/hour –DC-input power—308.79 W –DC heat dissipation—1054.52 BTU/hour Base module + DFC3B daughter card –Module current—4.57 A –Module power—191.94 W –AC-input power—239.93 W –AC heat dissipation—819.34 BTU/hour –DC-input power—257.98 W –DC heat dissipation—881.01 BTU/hour Base module + DFC3BXL daughter card –Module current—4.37 A –Module power—183.54 W –AC-input power—229.43 W –AC heat dissipation—783.49 BTU/hour –DC-input power—246.69 W –DC heat dissipation—842.46 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Table 2-39 WS-X6548-RJ-45 Physical and Environmental Specifications (continued) Item Specification