2-121 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 40-Gigabit Ethernet Modules Module front panel LEDsSTATUS Indicates the status of the module. Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics; an overtemperature condition has occurred. Red—A fault has been detected in the module. Off—The module is not powered up. ID Blinking blue—The module is being identified for attention. The LED is turned on by a CLI command to aid servicing personnel in identifying the module. SLOT 1, 2, 3, 4 Indicates the operational status of the CFP slot. Green—Slot is occupied and operational. Alternate flashing green and yellow—Slot is identified for customer attention. The alternate color flashing operates in conjunction with the flashing blue ID LED. Off—Slot is empty. LINK Indicates the link status of each port. When operating with 40-Gigabit CFP transceiver modules, the first LINK LED under each CFP slot indicates the status of the 40-Gigabit port. When operating with 10-Gigabit SFP+ transceivers, the four grouped LEDs associated with each optical bay indicate the port status of the four SFP+ transceivers in the FourX converter. Green—The port is active (the link is connected and operational). Yellow—The port is disabled. Alternate flashing green and yellow—Port is identified for customer attention. The alternate color flashing operates in conjunction with the flashing blue ID LED. Off—The port is not active or the link is not connected. Table 2-65 WS-X6904-40G Ethernet Module Physical and Environmental Specifications Item Specification Dimensions 1.73 x 14.4 x 16 in. (4.4 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 12 lb (5.4 kg) Excludes CFP optical modules. Each CFP optical module weighs 0.25 lb (0.11 kg) Table 2-64 WS-X6904-40G Ethernet Module Features (continued) Feature Description
2-122 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 40-Gigabit Ethernet Modules For more information about the WS-X6904-40G Ethernet module, see these publications: 40 Gigabit Ethernet on Cisco Catalyst 6500 Series Switches: How It Works NoteSome features described in the whitepaper will be supported in future releases. Cisco Catalyst 6900 Series 40 Gigabit Ethernet Interface Module for Cisco Catalyst 6500 Series Switches Data Sheet Power and heat numbers WS-X6904-40G-2T (base module + the DFC4-E daughter card)—16.67 A –Module power—700.14 W –AC-input power—875.18 W –AC heat dissipation—2988.72 BTU/hour –DC-input power—941.05 W –DC heat dissipation—3213.68 BTU/hour WS-X6908-10G-2TXL (base module + the DFC4-EXL daughter card)—17.03 A –Module power—715.26 W –AC-input power—894.08 W –AC heat dissipation—3053.27 BTU/hour –DC-input power—961.37 W –DC heat dissipation—3283.08 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Table 2-65 WS-X6904-40G Ethernet Module Physical and Environmental Specifications (continued) Item Specification
CH A P T E R 3-1 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 3 Installing Ethernet Switching Modules Revised: April 2012 This chapter describes how to safely install, remove, and verify the operation of the Ethernet switching modules in the Catalyst 6500 series switches, and it contains these sections: Safety, page 3-1 Installing an Ethernet Switching Module, page 3-2 Removing an Ethernet Switching Module, page 3-10 Installing Pluggable Transceivers, page 3-11 Attaching the Network Interface Cables, page 3-12 Verifying the Installation, page 3-15 What To Do After Installing Modules and Verifying Connectivity, page 3-17 Safety Safety warnings appear throughout this publication in procedures that may harm you if performed incorrectly. A warning symbol precedes each warning statement. The warnings below are general warnings that are applicable to the entire publication. WarningClass 1 laser product. Statement 1008 WarningOnly trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 WarningBefore opening the unit, disconnect the telephone-network cables to avoid contact with telephone-network voltages. Statement 1041
3-2 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 3 Installing Ethernet Switching Modules Installing an Ethernet Switching Module WarningDuring this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 93 WarningInvisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Statement 1051 WarningDuring this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 Installing an Ethernet Switching Module This section describes how to safely install and verify the operation of the Ethernet switching modules. Required Tools These tools are required to install switching modules in the chassis: Small flat-blade screwdriver No. 2 Phillips screwdriver Antistatic mat or foam pad to support an unpackaged module Your own ESD-prevention equipment or the disposable grounding wrist strap included with the module Chassis Slot Filler Restrictions for WS-X68xx and WS-X69xx Modules If you are installing one or more of the WS-X68xx or WS-X69xx modules in your chassis, the slots directly adjacent to these modules (above and below or to the left and to the right) must contain either another module or switching-module filler plates (Cisco part numbers WS-X6K-SLOT-CVR-E or SLOTBLANK-09). If either adjacent slot is unused and currently has a blank slot cover (Cisco part number WS-X6K-SLOT-CVR) installed, you must remove the blank slot cover and replace it with a switching-module filler plate for NEBS compliance.
3-3 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 3 Installing Ethernet Switching Modules Installing an Ethernet Switching Module Installing an Ethernet Switching Module CautionTo prevent ESD damage, handle modules by the carrier edges only. To install an Ethernet switching module in the chassis, follow these steps: Step 1Attach an ESD grounding strap to your wrist and to ground. NoteIf you are unsure about the correct way to attach an ESD grounding strap, see the “Attaching Your ESD Grounding Strap” section on page C-1 for instructions. Step 2Choose a slot for the module. NoteRefer to your software release notes or to Chapter 2 for any information on slot or chassis restrictions for the module that you are installing. Step 3If you are installing either a WS-X68xx or WS-X69xx module, verify that the two slots adjacent to the slot where you are installing the module have either a module installed in them or a switching-module filler plate installed (Cisco part numbers SLOTBLANK-09 or WS-X6K-SLOT-CVR-E) if either slot is unused. If either slot has a blank slot cover (Cisco part number WS-X6K-SLOT-CVR), you need to remove the blank slot cover and replace it with a switching-module filler plate for NEBS compliance. Step 4Verify that there is enough clearance to accommodate any interface equipment, such as pluggable transceivers, that you will install directly to the module ports. If possible, install modules between empty slots that contain only module filler plates. Step 5Verify that you have adequate cable guides installed on the chassis to accept the additional network interface cables for the new module. Step 6Verify that the captive installation screws are tightened on all modules installed in the chassis. NoteThis action assures that the EMI gaskets on all of the modules are fully compressed in order to maximize the opening space for the new or replacement module. If the captive installation screws are loose, the EMI gaskets on the installed modules will push adjacent modules toward the open slot, reducing the opening size and making it difficult to install the module. Step 7Remove the module filler plate covering the selected slot by removing the two Phillips pan-head screws from the filler plate. NoteIf you must remove an existing module, refer to “Removing an Ethernet Switching Module” section on page 3-10. Step 8Remove the new module from its shipping packaging and from the antistatic shipping bag. CautionTo prevent ESD damage, handle modules by the carrier edges only. Step 9Fully open both ejector levers on the new module. (See Figure 3-1.)
3-4 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 3 Installing Ethernet Switching Modules Installing an Ethernet Switching Module Step 10Depending on the orientation of the slots in the chassis (horizontal or vertical), perform one of the following two sets of steps: Chassis with horizontal slots a.Position the new module in the slot. (See Figure 3-1.) Make sure that you align the sides of the module carrier with the slot guides on each side of the chassis slot. b.Carefully slide the module into the slot until the EMI gasket along the top edge of the module makes contact with the module or cover plate in the slot above it and the module ejector levers have both closed to approximately 45 degrees with respect to the module faceplate. (See Figure 3-2.) Figure 3-1 Positioning the Module in a Horizontal Slot Chassis 58569INPUT OKFA N OKOUTPUT FA I L o INPUT OKFA N OKOUTPUT FA I L o 1 2 3 FA N STATUS 4 5 6 S U P E R V IS O R 2 W S -X 6 K -S U P 2 -2G ES T A T U SS Y S T E MC O N S O L EP W R M G M TR E S E TC O N S O L EC O N S O L E P O R T M O D EP C M C I AE J E C TP O R T 1P O R T 2S w it c h L o a d 1 0 0 % 1 % 24 PORT 100FX WS-X6224S E L E C T N E X T EMI gasket EMI gasket Insert module between slot guides Ejector lever fully extended S T A T U S A C T IV E 4 3 5 5 4 6 6 SWITCH FABRIC MDL W S-C6500-SFM STATUS ACTIVE S U P E R V IS O R 2 W S -X 6 K -S U P 2 -2 G ES T A T U SS Y S T E MC O N S O L EP W R M G M TR E S E TC O N S O L EC O N S O L E P O R T M O D EP C M C I AE J E C TP O R T 1P O R T 2S w i tc h L o a d 1 0 0 % 1 %
3-5 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 3 Installing Ethernet Switching Modules Installing an Ethernet Switching Module c.Using the thumb and forefinger of each hand, grasp the two ejector levers and gently press down to create a small 0.040 inch (1 mm) gap between the module’s EMI gasket and the module or cover plate above it. (See Figure 3-2.) NoteDo not press down too forcefully on the levers because they will bend and get damaged. Figure 3-2 Clearing the EMI Gasket in a Horizontal Slot Chassis d. While gently pressing down, simultaneously close the left and right ejector levers to fully seat the module in the backplane connector. The ejector levers are fully closed when they are flush with the module faceplate. (See Figure 3-3.) NoteFailure to fully seat the module in the backplane connector can result in error messages. e.Tighten the two captive installation screws on the module. NoteMake sure the ejector levers are fully closed before tightening the captive installation screws. 1 2 3 FA N STATUS 4 5 6 S U P E R VIS O R 2 W S -X 6 K -S U P 2-2 G ESTATUSSYSTEMCONSOLEPW R MGMTRESETCONSOLECONSOLE PORT MODEPCMCIA EJECTPORT 1PORT 2Switch Load 100% 1% LINK LINK S U P E RV IS O R 2 W S -X 6 K -S U P 2-2G ESTATUSSYSTEMCONSOLEPWR MGMTRESETCONSOLECONSOLE PORT MODEPCMCIA EJECTPORT 1PORT 2Switch Load 100% 1% LINK LINK 1 mm 24 PORT 100FX WS-X6224STATUS ACTIVESELECT NEXT 4 3 5 5 4 6 6 SWITCH FABIRD MDL WS-C6500-SFM S T A TU S A C T IV EGap between the module EMI gasket and the module above it Press downPress down 58570
3-6 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 3 Installing Ethernet Switching Modules Installing an Ethernet Switching Module f.Verify that the module STATUS LED is lit. g.Periodically check the STATUS LED: If the STATUS LED changes from orange to green, the module has successfully completed the boot process and is now online. If the STATUS LED remains orange or turns red, the module has not successfully completed the boot process and may have encountered an error. For more information about the orange or red STATUS LED states, see the LED table for your specific module in Chapter 2. NoteYou should install switching-module filler plates (Cisco part number 800-00292-01) in any empty slots to maintain consistent airflow through the switch chassis. Figure 3-3 Closing the Ejector Levers in a Horizontal Slot Chassis Chassis with vertical slots a.Position the module in the slot. (See Figure 3-4.) Make sure that you align the sides of the switching-module carrier with the slot guides on the top and bottom of the chassis slot. b.Carefully slide the module into the slot until the EMI gasket along the right edge of the module makes contact with the module or cover plate in the slot adjacent to it and the module ejector levers have both closed to approximately 45 degrees with respect to the module faceplate. (See Figure 3-5.) 1 2 3 FA N STATUS 4 5 6 S U P E R V IS O R 2 W S -X 6K -S U P 2-2 G ESTATUSSYSTEMCONSOLEPW R MGMTRESETCONSOLECONSOLE PORT MODEPCMCIA EJECTPORT 1PORT 2Switch Load 100% 1% LINK LINK S U P E R V IS O R 2 W S -X 6 K -S U P 2 -2 G ESTATUSSYSTEMCONSOLEPWR MGMTRESETCONSOLECONSOLE PORT MODEPCMCIA EJECTPORT 1PORT 2Switch Load 100% 1% LINK LINK SWITCH FABRIC MDL WS-C6500-SFMSTATUS ACTIVESELECT NEXT 58571 Ejector levers flush with module faceplate
3-7 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 3 Installing Ethernet Switching Modules Installing an Ethernet Switching Module Figure 3-4 Positioning the Module in a Vertical Slot Chassis INPUT OKFA N OKOUTPUT FAILo INPUT OKFA N OKOUTPUT FAILo FA N STATUS Ejector lever fully extended SUPERVISOR2 WS-X6K-SUP2-2GES T A T U SS Y S T E MC O N S O L EP W R M G M TR E S E TC O N S O L EC O N S O L E P O R T M O D E P C M C I AE J E C T P O R T 1 P O R T 2 S w i t c h L o a d 1 0 0 % 1 % SU P E RV ISO R 2 W S -X6 K -S U P 2 -2G ESTATUSSYSTEMCONSOLEPWR MGMTRESETC O N S O L EC O N S O L E P O R T M O D E P C M C IA E J E C T P O R T 1 P O R T 2 S w itc h L o a d 1 0 0 % 1 % SWITCH FABRIC MDLWS-C6500-SFM STATUS ACTIVE 436 S E L E C T N E X T 24 PORT 100FXWS-X6224 S T A T U S AC T IV E EMI gasketEMI gasket 63585 Insert module between slot guides
3-8 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 3 Installing Ethernet Switching Modules Installing an Ethernet Switching Module Figure 3-5 Clearing the EMI Gasket in a Vertical Slot Chassis c. Using the thumb and forefinger of each hand, grasp the two ejector levers and exert a slight pressure to the left, deflecting the module approximately 0.040 inches (1 mm) creating a small gap between the module’s EMI gasket and the module or cover plate adjacent to it. (See Figure 3-5.) NoteDo not exert too much pressure on the ejector levers because they will bend and get damaged. d.While gently pressing down on the ejector levers, simultaneously close both levers to fully seat the module in the backplane connector. The ejector levers are fully closed when they are flush with the module faceplate. (See Figure 3-6.) INPUT OKFA N OKOUTPUT FAILo INPUT OKFA N OKOUTPUT FAILo FA N STATUS SELECT NEXT 24 PORT 100FXWS-X6224 ST ATUS ACTIVE SUPERVISOR2 WS-X6K-SUP2-2GES T A T U SS Y S T E MC O N S O L EP W R M G M TR E S E TC O N S O L EC O N S O L E P O R T M O D E P C M C I AE J E C T P O R T 1 P O R T 2 S w i t c h L o a d 1 0 0 % 1 % S U P E R V IS O R 2 W S -X 6 K -S UP 2 -2G ESTATUSSYSTEMCONSOLEPWR MGMTRESETC O N S O L EC O N S O L E P O R T M O D E P C M C I A E J E C T P O R T 1 P O R T 2 S w itc h L o a d 1 0 0 % 1 % 63586 Gap between the module EMI gasket and the module above it SWITCH FABIRD MDL WS-C6500-SFM STATUS ACTIVE 1 mm Press left Press left