    							2-121
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      40-Gigabit Ethernet Modules
    Module front panel LEDsSTATUS
    Indicates the status of the module.
    Green—All diagnostics pass; the module is operational.
    Orange—The module is booting or running diagnostics; an 
    overtemperature condition has occurred.
    Red—A fault has been detected in the module.
    Off—The module is not powered up.
    ID
    Blinking blue—The module is being identified for attention. The 
    LED is turned on by a CLI command to aid servicing personnel in 
    identifying the module.
    SLOT 1, 2, 3, 4
    Indicates the operational status of the CFP slot.
    Green—Slot is occupied and operational.
    Alternate flashing green and yellow—Slot is identified for 
    customer attention. The alternate color flashing operates in 
    conjunction with the flashing blue ID LED.
    Off—Slot is empty.
    LINK
    Indicates the link status of each port. When operating with 40-Gigabit 
    CFP transceiver modules, the first LINK LED under each CFP slot 
    indicates the status of the 40-Gigabit port. When operating with 
    10-Gigabit SFP+ transceivers, the four grouped LEDs associated with 
    each optical bay indicate the port status of the four SFP+ transceivers 
    in the FourX converter.
    Green—The port is active (the link is connected and operational).
    Yellow—The port is disabled.
    Alternate flashing green and yellow—Port is identified for 
    customer attention. The alternate color flashing operates in 
    conjunction with the flashing blue ID LED.
    Off—The port is not active or the link is not connected.
    Table 2-65 WS-X6904-40G Ethernet Module Physical and Environmental 
    Specifications 
    Item Specification
    Dimensions 1.73 x 14.4 x 16 in. (4.4 x 35.6 x 40.6 cm). Occupies one slot in the 
    chassis.
    Weight 12  lb (5.4  kg) Excludes CFP optical modules. Each CFP optical module 
    weighs 0.25 lb (0.11 kg)
    Table 2-64 WS-X6904-40G Ethernet Module Features (continued)
    Feature Description 
    						
    							2-122
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      40-Gigabit Ethernet Modules
    For more information about the WS-X6904-40G Ethernet module, see these publications:
    40 Gigabit Ethernet on Cisco Catalyst 6500 Series Switches: How It Works
    NoteSome features described in the whitepaper will be supported in future releases.
    Cisco Catalyst 6900 Series 40 Gigabit Ethernet Interface Module for Cisco Catalyst 6500 Series 
    Switches Data Sheet Power and heat numbers
    WS-X6904-40G-2T (base module + the DFC4-E daughter 
    card)—16.67 A
     –Module power—700.14 W
     –AC-input power—875.18 W
     –AC heat dissipation—2988.72 BTU/hour
     –DC-input power—941.05 W
     –DC heat dissipation—3213.68 BTU/hour
    WS-X6908-10G-2TXL (base module + the DFC4-EXL daughter 
    card)—17.03 A
     –Module power—715.26 W
     –AC-input power—894.08 W
     –AC heat dissipation—3053.27 BTU/hour
     –DC-input power—961.37 W
     –DC heat dissipation—3283.08 BTU/hour
    Environment
    Operating temperature
    Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    Humidity (RH) ambient 
    (noncondensing)10 to 90%
    Operating altitude
    Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 
    3000 m)
    Table 2-65 WS-X6904-40G Ethernet Module Physical and Environmental 
    Specifications (continued)
    Item Specification 
    						
    							CH A P T E R
    3-1
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    3
    Installing Ethernet Switching Modules
    Revised: April 2012
    This chapter describes how to safely install, remove, and verify the operation of the Ethernet switching 
    modules in the Catalyst 6500 series switches, and it contains these sections:
    Safety, page 3-1
    Installing an Ethernet Switching Module, page 3-2
    Removing an Ethernet Switching Module, page 3-10
    Installing Pluggable Transceivers, page 3-11
    Attaching the Network Interface Cables, page 3-12
    Verifying the Installation, page 3-15
    What To Do After Installing Modules and Verifying Connectivity, page 3-17
    Safety
    Safety warnings appear throughout this publication in procedures that may harm you if performed 
    incorrectly. A warning symbol precedes each warning statement. The warnings below are general 
    warnings that are applicable to the entire publication.
    WarningClass 1 laser product. Statement 1008
    WarningOnly trained and qualified personnel should be allowed to install, replace, or service this equipment. 
    Statement 1030
    WarningBefore opening the unit, disconnect the telephone-network cables to avoid contact with 
    telephone-network voltages. Statement 1041  
    						
    							3-2
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 3      Installing Ethernet Switching Modules
      Installing an Ethernet Switching Module
    WarningDuring this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly 
    touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 93
    WarningInvisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into 
    beams or view directly with optical instruments. Statement 1051
    WarningDuring this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly 
    touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94
    Installing an Ethernet Switching Module
    This section describes how to safely install and verify the operation of the Ethernet switching modules.
    Required Tools
    These tools are required to install switching modules in the chassis:
    Small flat-blade screwdriver
    No. 2 Phillips screwdriver
    Antistatic mat or foam pad to support an unpackaged module 
    Your own ESD-prevention equipment or the disposable grounding wrist strap included with the 
    module
    Chassis Slot Filler Restrictions for WS-X68xx and WS-X69xx Modules
    If you are installing one or more of the WS-X68xx or WS-X69xx modules in your chassis, the slots 
    directly adjacent to these modules (above and below or to the left and to the right) must contain either 
    another module or switching-module filler plates (Cisco part numbers WS-X6K-SLOT-CVR-E or 
    SLOTBLANK-09). If either adjacent slot is unused and currently has a blank slot cover (Cisco part 
    number WS-X6K-SLOT-CVR) installed, you must remove the blank slot cover and replace it with a 
    switching-module filler plate for NEBS compliance.  
    						
    							3-3
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 3      Installing Ethernet Switching Modules
      Installing an Ethernet Switching Module
    Installing an Ethernet Switching Module
    CautionTo prevent ESD damage, handle modules by the carrier edges only.
    To install an Ethernet switching module in the chassis, follow these steps:
    Step 1Attach an ESD grounding strap to your wrist and to ground. 
    NoteIf you are unsure about the correct way to attach an ESD grounding strap, see the “Attaching 
    Your ESD Grounding Strap” section on page C-1 for instructions.
    Step 2Choose a slot for the module. 
    NoteRefer to your software release notes or to Chapter 2 for any information on slot or chassis 
    restrictions for the module that you are installing.
    Step 3If you are installing either a WS-X68xx or WS-X69xx module, verify that the two slots adjacent to the 
    slot where you are installing the module have either a module installed in them or a switching-module 
    filler plate installed (Cisco part numbers SLOTBLANK-09 or WS-X6K-SLOT-CVR-E) if either slot is 
    unused. If either slot has a blank slot cover (Cisco part number WS-X6K-SLOT-CVR), you need to 
    remove the blank slot cover and replace it with a switching-module filler plate for NEBS compliance. 
    Step 4Verify that there is enough clearance to accommodate any interface equipment, such as pluggable 
    transceivers, that you will install directly to the module ports. If possible, install modules between empty 
    slots that contain only module filler plates.
    Step 5Verify that you have adequate cable guides installed on the chassis to accept the additional network 
    interface cables for the new module.
    Step 6Verify that the captive installation screws are tightened on all modules installed in the chassis. 
    NoteThis action assures that the EMI gaskets on all of the modules are fully compressed in order to 
    maximize the opening space for the new or replacement module. If the captive installation 
    screws are loose, the EMI gaskets on the installed modules will push adjacent modules toward 
    the open slot, reducing the opening size and making it difficult to install the module.
    Step 7Remove the module filler plate covering the selected slot by removing the two Phillips pan-head screws 
    from the filler plate. 
    NoteIf you must remove an existing module, refer to “Removing an Ethernet Switching Module” 
    section on page 3-10.
    Step 8Remove the new module from its shipping packaging and from the antistatic shipping bag.
    CautionTo prevent ESD damage, handle modules by the carrier edges only.
    Step 9Fully open both ejector levers on the new module. (See Figure 3-1.) 
    						
    							3-4
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 3      Installing Ethernet Switching Modules
      Installing an Ethernet Switching Module
    Step 10Depending on the orientation of the slots in the chassis (horizontal or vertical), perform one of the 
    following two sets of steps:
    Chassis with horizontal slots
    a.Position the new module in the slot. (See Figure 3-1.) Make sure that you align the sides of the 
    module carrier with the slot guides on each side of the chassis slot. 
    b.Carefully slide the module into the slot until the EMI gasket along the top edge of the module makes 
    contact with the module or cover plate in the slot above it and the module ejector levers have both 
    closed to approximately 45 degrees with respect to the module faceplate. (See Figure 3-2.)
    Figure 3-1 Positioning the Module in a Horizontal Slot Chassis
    58569INPUT
    OKFA N
    OKOUTPUT
    FA I L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I L
    o
    1
    2
    3
    FA N
    STATUS
    4
    5
    6
    S
    U
    P
    E
    R
    V
    IS
    O
    R
    2 W
    S
    -X
    6
    K
    -S
    U
    P
    2
    -2G
    ES
    T
    A
    T
    U
    SS
    Y
    S
    T
    E
    MC
    O
    N
    S
    O
    L
    EP
    W
    R
     
    M
    G
    M
    TR
    E
    S
    E
    TC
    O
    N
    S
    O
    L
    EC
    O
    N
    S
    O
    L
    E
    P
    O
    R
    T
    M
    O
    D
    EP
    C
    M
    C
    I
    AE
    J
    E
    C
    TP
    O
    R
    T
     1P
    O
    R
    T
     2S
    w
    it
    c
    h
     
     
     
     L
    o
    a
    d
     
     
     
    1
    0
    0
    %
    1
    %
    24 PORT 100FX
    WS-X6224S
    E
    L
    E
    C
    T
    N
    E
    X
    T
    EMI gasket
    EMI gasket Insert module 
    between slot guides
    Ejector lever fully 
    extended
    S
    T
    A
    T
    U
    S
    A
    C
    T
    IV
    E
    4
    3
    5
    5 4
    6
    6
    SWITCH FABRIC MDL
    W
    S-C6500-SFM
    STATUS
    ACTIVE
    S
    U
    P
    E
    R
    V
    IS
    O
    R
    2 W
    S
    -X
    6
    K
    -S
    U
    P
    2
    -2
    G
    ES
    T
    A
    T
    U
    SS
    Y
    S
    T
    E
    MC
    O
    N
    S
    O
    L
    EP
    W
    R
     
    M
    G
    M
    TR
    E
    S
    E
    TC
    O
    N
    S
    O
    L
    EC
    O
    N
    S
    O
    L
    E
    P
    O
    R
    T
    M
    O
    D
    EP
    C
    M
    C
    I
    AE
    J
    E
    C
    TP
    O
    R
    T
     
    1P
    O
    R
    T
     
    2S
    w
    i
    tc
    h
     
      
     
    L
    o
    a
    d
      
     
    1
    0
    0
    %
    1
    % 
    						
    							3-5
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 3      Installing Ethernet Switching Modules
      Installing an Ethernet Switching Module
    c.Using the thumb and forefinger of each hand, grasp the two ejector levers and gently press down to 
    create a small 0.040 inch (1 mm) gap between the module’s EMI gasket and the module or cover 
    plate above it. (See Figure 3-2.)
    NoteDo not press down too forcefully on the levers because they will bend and get damaged.
    Figure 3-2 Clearing the EMI Gasket in a Horizontal Slot Chassis
    d.
    While gently pressing down, simultaneously close the left and right ejector levers to fully seat the 
    module in the backplane connector. The ejector levers are fully closed when they are flush with the 
    module faceplate. (See Figure 3-3.)
    NoteFailure to fully seat the module in the backplane connector can result in error messages.
    e.Tighten the two captive installation screws on the module.
    NoteMake sure the ejector levers are fully closed before tightening the captive installation 
    screws.
    1
    2
    3
    FA N
    STATUS
    4
    5
    6
    S
    U
    P
    E
    R
    VIS
    O
    R
    2 W
    S
    -X
    6
    K
    -S
    U
    P
    2-2
    G
    ESTATUSSYSTEMCONSOLEPW
    R MGMTRESETCONSOLECONSOLE
    PORT
    MODEPCMCIA EJECTPORT 1PORT 2Switch    Load   
    100%
    1%
    LINK
    LINK
    S
    U
    P
    E
    RV
    IS
    O
    R
    2 W
    S
    -X
    6
    K
    -S
    U
    P
    2-2G
    ESTATUSSYSTEMCONSOLEPWR MGMTRESETCONSOLECONSOLE
    PORT
    MODEPCMCIA EJECTPORT 1PORT 2Switch    Load   
    100%
    1%
    LINK
    LINK
    1 mm 
    24 PORT 100FX
    WS-X6224STATUS
    ACTIVESELECT
    NEXT
    4
    3
    5
    5 4
    6
    6
    SWITCH FABIRD MDL
    WS-C6500-SFM
    S
    T
    A
    TU
    S
    A
    C
    T
    IV
    EGap between the module
    EMI gasket and the 
    module above it
    Press downPress down
    58570 
    						
    							3-6
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 3      Installing Ethernet Switching Modules
      Installing an Ethernet Switching Module
    f.Verify that the module STATUS LED is lit. 
    g.Periodically check the STATUS LED:
    If the STATUS LED changes from orange to green, the module has successfully completed the 
    boot process and is now online. 
    If the STATUS LED remains orange or turns red, the module has not successfully completed the 
    boot process and may have encountered an error. For more information about the orange or red 
    STATUS LED states, see the LED table for your specific module in Chapter 2.
    NoteYou should install switching-module filler plates (Cisco part number 800-00292-01) in any 
    empty slots to maintain consistent airflow through the switch chassis.
    Figure 3-3 Closing the Ejector Levers in a Horizontal Slot Chassis
    Chassis with vertical slots
    a.Position the module in the slot. (See Figure 3-4.) Make sure that you align the sides of the 
    switching-module carrier with the slot guides on the top and bottom of the chassis slot.
    b.Carefully slide the module into the slot until the EMI gasket along the right edge of the module 
    makes contact with the module or cover plate in the slot adjacent to it and the module ejector levers 
    have both closed to approximately 45  degrees with respect to the module faceplate. (See Figure 3-5.)
    1
    2
    3
    FA N
    STATUS
    4
    5
    6
    S
    U
    P
    E
    R
    V
    IS
    O
    R
    2 W
    S
    -X
    6K
    -S
    U
    P
    2-2
    G
    ESTATUSSYSTEMCONSOLEPW
    R MGMTRESETCONSOLECONSOLE
    PORT
    MODEPCMCIA EJECTPORT 1PORT 2Switch    Load   
    100%
    1%
    LINK
    LINK
    S
    U
    P
    E
    R
    V
    IS
    O
    R
    2 W
    S
    -X
    6
    K
    -S
    U
    P
    2
    -2
    G
    ESTATUSSYSTEMCONSOLEPWR MGMTRESETCONSOLECONSOLE
    PORT
    MODEPCMCIA EJECTPORT 1PORT 2Switch    Load   
    100%
    1%
    LINK
    LINK
    SWITCH FABRIC MDL
    WS-C6500-SFMSTATUS
    ACTIVESELECT
    NEXT
    58571
    Ejector levers flush
    with module faceplate 
    						
    							3-7
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 3      Installing Ethernet Switching Modules
      Installing an Ethernet Switching Module
    Figure 3-4 Positioning the Module in a Vertical Slot Chassis
    INPUT
    OKFA N
    OKOUTPUT
    FAILo
    INPUT
    OKFA N
    OKOUTPUT
    FAILo
    FA N
    STATUS
    Ejector lever fully 
    extended
    SUPERVISOR2 WS-X6K-SUP2-2GES
    T
    A
    T
    U
    SS
    Y
    S
    T
    E
    MC
    O
    N
    S
    O
    L
    EP
    W
    R
     
    M
    G
    M
    TR
    E
    S
    E
    TC
    O
    N
    S
    O
    L
    EC
    O
    N
    S
    O
    L
    E
    P
    O
    R
    T
    M
    O
    D
    E
    P
    C
    M
    C
    I
    AE
    J
    E
    C
    T
    P
    O
    R
    T
     
    1
    P
    O
    R
    T
     
    2
    S
    w
    i
    t
    c
    h
     
     
     
     
    L
    o
    a
    d
     
     
     
    1
    0
    0
    %
    1
    %
    SU
    P
    E
    RV
    ISO
    R
    2 W
    S
    -X6
    K
    -S
    U
    P
    2
    -2G
    ESTATUSSYSTEMCONSOLEPWR MGMTRESETC
    O
    N
    S
    O
    L
    EC
    O
    N
    S
    O
    L
    E
    P
    O
    R
    T
    M
    O
    D
    E
    P
    C
    M
    C
    IA
    E
    J
    E
    C
    T
    P
    O
    R
    T
     1
    P
    O
    R
    T
     2
    S
    w
    itc
    h
        L
    o
    a
    d
       
    1
    0
    0
    %
    1
    %
    SWITCH FABRIC MDLWS-C6500-SFM
    STATUS
    ACTIVE
    436
    S
    E
    L
    E
    C
    T
    N
    E
    X
    T
    24 PORT 100FXWS-X6224
    S
    T
    A
    T
    U
    S
    AC
    T
    IV
    E
    EMI
    gasketEMI
    gasket
    63585
    Insert module 
    between slot guides 
    						
    							3-8
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 3      Installing Ethernet Switching Modules
      Installing an Ethernet Switching Module
    Figure 3-5 Clearing the EMI Gasket in a Vertical Slot Chassis
    c.
    Using the thumb and forefinger of each hand, grasp the two ejector levers and exert a slight pressure 
    to the left, deflecting the module approximately 0.040 inches (1 mm) creating a small gap between 
    the module’s EMI gasket and the module or cover plate adjacent to it. (See Figure 3-5.)
    NoteDo not exert too much pressure on the ejector levers because they will bend and get 
    damaged.
    d.While gently pressing down on the ejector levers, simultaneously close both levers to fully seat the 
    module in the backplane connector. The ejector levers are fully closed when they are flush with the 
    module faceplate. (See Figure 3-6.)
    INPUT
    OKFA N
    OKOUTPUT
    FAILo
    INPUT
    OKFA N
    OKOUTPUT
    FAILo
    FA N
    STATUS
    SELECT
    NEXT
    24 PORT 100FXWS-X6224
    ST
    ATUS
    ACTIVE
    SUPERVISOR2 WS-X6K-SUP2-2GES
    T
    A
    T
    U
    SS
    Y
    S
    T
    E
    MC
    O
    N
    S
    O
    L
    EP
    W
    R
     
    M
    G
    M
    TR
    E
    S
    E
    TC
    O
    N
    S
    O
    L
    EC
    O
    N
    S
    O
    L
    E
    P
    O
    R
    T
    M
    O
    D
    E
    P
    C
    M
    C
    I
    AE
    J
    E
    C
    T
    P
    O
    R
    T
     
    1
    P
    O
    R
    T
     
    2
    S
    w
    i
    t
    c
    h
     
     
     
     
    L
    o
    a
    d
     
     
     
    1
    0
    0
    %
    1
    %
    S
    U
    P
    E
    R
    V
    IS
    O
    R
    2 W
    S
    -X
    6
    K
    -S
    UP
    2
    -2G
    ESTATUSSYSTEMCONSOLEPWR MGMTRESETC
    O
    N
    S
    O
    L
    EC
    O
    N
    S
    O
    L
    E
    P
    O
    R
    T
    M
    O
    D
    E
    P
    C
    M
    C
    I
    A
    E
    J
    E
    C
    T
    P
    O
    R
    T
     1
    P
    O
    R
    T
     2
    S
    w
    itc
    h
      
      L
    o
    a
    d
       
    1
    0
    0
    %
    1
    %
    63586
    Gap between the module
    EMI gasket and the 
    module above it
    SWITCH FABIRD MDL WS-C6500-SFM
    STATUS
    ACTIVE
    1 mm 
    Press left
    Press left 
    						
    All Cisco manuals Comments (0)