2-41 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6348-RJ21V Ethernet Module The WS-X6348-RJ21V Ethernet module provides 48 10/100-Mbps full- or half-duplex ports. (See (Figure 2-12.) Table 2-26 lists the features and description for the module, and Table 2-27 lists the physical and environmental specifications for the module. Figure 2-12 WS-X6348-RJ21V Switching Module Front Panel Table 2-26 WS-X6348-RJ21V Features Feature Description Ports per module 48 ports. Ports are numbered (left to right): –First connector, ports 1 to 12; second connector, ports 13–24; third connector, ports 25–32; fourth connector, 33–48. 4 port groups Port ranges per port group: 1–12, 13–24, 25–36, 37–48 Port connector type RJ-21 (12 ports per connector) Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable Buffer size 128 KB QoS Number of egress queues: 2 Number of ingress queues: 1 Number of thresholds per egress queue: 2 Number of thresholds per ingress queue: 4 Maximum frame size Up to 8092 bytes per frame Module oversubscription rate N/A Supervisor engine support Supported on the following supervisor engines: Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine720-10GE Software support With Supervisor Engine 2—12.1(8a)EX With Supervisor Engine 32—12.2(18)SXF With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720—12.2(14)SX With Supervisor Engine720-10GE—12.2(33)SXH 6814948 PORT 10/100 BASE-T ETHERNETSWITCHING MODULEPHONE WS-X6348-RJ21 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748 13-241-1225-3637-48 STATUS
2-42 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Queues per portTx—2q2t Rx—1q4t Chassis/slot restrictions No chassis or slot restrictions; the module can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis. Bus connection 32-Gbps shared bus Module upgrades available PoE support Cisco prestandard only. The WS-F6K-VPWR= PoE daughter card is factory installed on the module. No PoE field upgrades are available. Distributed forwarding supportNot supported. Pluggable transceivers supportNot supported. TDR support Not supported. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. Table 2-26 WS-X6348-RJ21V Features (continued) Feature Description
2-43 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6348-RJ45 and WS-X6348-RJ45V Ethernet Modules The WS-X6348-RJ45 and the WS-X6348-RJ45V Ethernet modules, provide 48 10/100-Mbps full- or half-duplex ports. (See Table 2-28.) Figure 2-13 shows the module front panel. Figure 2-13 WS-X6348-RJ45 and WS-X6348-RJ45V Ethernet Modules Front Panel Table 2-29 lists the module features, and Table 2-30 lists the module physical and environmental specifications. Table 2-27 WS-X6348-RJ21V Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 9.1 lb (4.13 kg) Power and heat numbers Module current—2.81 A Module power—118.02 W AC-input power—147.53 W AC heat dissipation—503.80 BTU/hour DC-input power—158.63 W DC heat dissipation—541.72 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Table 2-28 WS-X6348-RJ45 Modules Module Description WS-X6348-RJ45 Base module without daughter cards installed. WS-X6348-RJ45V Base module equipped with a factory-installed Cisco prestandard PoE daughter card (WS-F6K-VPWR-GE). 3949648 PORT 10/100 BASE-T STATUS ETHERNET SWITCHING MODULE WS-X6348-RJ-45 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748 1 2 12 14 24 26 36 38 48 PHONE
2-44 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-29 WS-X6348-RJ45 and WS-X6348-RJ45V Ethernet Modules Features Feature Description Ports per module 48 ports (both modules). Ports are numbered (left to right): –Top row, odd numbered ports 1 through 47. –Bottom row, even numbered ports 2 through 48. 4 port groups Port ranges per port group: 1–12, 13–24, 25–36, 37–48 Port connector type RJ-45 (both modules) Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable (both modules) Buffer size 128 KB per port (both modules) QoS Number of egress queues: 2 Number of ingress queues: 1 Number of thresholds per egress queue: 2 Number of thresholds per ingress queue: 4 Maximum frame size Up to 8092 bytes per frame (both modules) Module oversubscription rate N/A Supervisor engine support Supported on the following supervisor engines: Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine720-10GE Software support With Supervisor Engine 2—12.1(2)E With Supervisor Engine 32—12.2(18)SXF With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720—12.2(14)SX With Supervisor Engine720-10GE—12.2(33)SXH Queues per port Both modules: Tx—2q2t Rx—1q4t Chassis/slot restrictions No chassis or slot restrictions; the modules can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis.
2-45 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Bus connection 32-Gbps shared bus (both modules) Module upgrades available PoE support WS-X6348-RJ45—Field upgradeable to Cisco prestandard with the WS-F6K-VPWR= PoE daughter card. WS-X6348-RJ-45V—Comes equipped with the WS-F6K-VPWR daughter card. See the Cisco Catalyst 6500 Series Power over Ethernet Daughter Cards Field-Upgrade Installation Note for field upgrade procedures. See Appendix A for further information on the PoE daughter cards. Distributed forwarding supportNot supported. Pluggable transceivers supportNot supported. TDR support Not supported. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. Table 2-29 WS-X6348-RJ45 and WS-X6348-RJ45V Ethernet Modules Features (continued) Feature Description
2-46 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-30 WS-X6348-RJ45 and WS-X6348-RJ45V Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight WS-X6348-RJ45—7.2 lb (3.26 kg) WS-X6348-RJ45V—8.8 lb (3.99 kg) Power and heat numbers WS-X6348-RJ45 –Module current—2.39 A –Module power—100.38 W –AC-input power—125.48 W –AC heat dissipation—428.50 BTU/hour –DC-input power—134.92 W –DC heat dissipation—460.75 BTU/hour WS-X6348-RJ45V (base module + PoE daughter card) –Module current—2.81 A –Module power—118.02 W –AC-input power—147.53 W –AC heat dissipation—503.80 BTU/hour –DC-input power—158.63 W –DC heat dissipation—541.72 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
2-47 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6516-GE-TX Ethernet Module The WS-X6516-GE-TX Ethernet module provides 16 10/100/1000-Mbps full- or half-duplex ports. (See (Figure 2-14).) Table 2-31 lists the features and description for the module, and Table 2-32 lists the physical and environmental specifications for the module. Figure 2-14 WS-X6516-GE-TX Ethernet Module Front Panel Table 2-31 WS-X6516-GE-TX Ethernet Module Features Feature Description Ports per module 16 ports. Ports are numbered from 1 (left) to 16 (right). 2 port groups Port ranges per port group: 1–8, 9–16 Port connector type RJ-45 Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable Buffer size 512 KB per port QoS Number of egress queues: 3 Number of ingress queues: 2 Number of thresholds per egress queue: 2 Number of thresholds per ingress queue: 4 Maximum frame size Up to 9216 bytes per frame Module oversubscription rate N/A Supervisor engine support Supported on the following supervisor engines: Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine 720-10GE Software support With Supervisor Engine 2—12.1(8a)EX With Supervisor Engine 32—12.2(18)SXF With Supervisor Engine 32 PISA—12.2(18)ZY With Supervisor Engine 720—12.2(14)SX With Supervisor Engine720-10GE—12.2(33)SXH Queues per port Tx—1p2q2t Rx—1p1q4t 63187 WS-X6516-GE-T X 16 PORT 1000 BASE-T GE12345678910111213141516 LINK STATUS LINKLINKLINKLINKLINKLINKLINKLINKLINKLINKLINKLINKLINKLINKLINK
2-48 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Chassis/slot restrictions No chassis or slot restrictions; the module can occupy any slot in any Catalyst 6500 or Catalyst 6500-E chassis. Bus connection 32-Gbps shared bus Module upgrades available PoE support Not supported. Distributed forwarding supportNot supported. Pluggable transceivers supportNot supported. TDR support Not supported. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics. An overtemperature condition has occurred. (A minor temperature threshold has been exceeded during environmental monitoring.) Red—The module is resetting. The switch has just been powered on or the module has been hot inserted during the normal initialization sequence. An overtemperature condition has occurred. (A major temperature threshold has been exceeded during environmental monitoring.) If the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. LINK Green—The port is active (the link is connected and operational). Orange—The module or port is disabled through the CLI command or the module is initializing1. Flashing orange—The port is faulty and has been disabled. Off—The port is not active or the link is not connected. PHONE Green—The PoE daughter card is installed and detected. Off—The PoE daughter card is not detected or is not installed. 1. Verify that all LINK LEDs are functioning. Table 2-31 WS-X6516-GE-TX Ethernet Module Features (continued) Feature Description
2-49 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules Table 2-32 WS-X6516-GE-TX Ethernet Module Physical and Environmental Specifications Item Specification Dimensions (H x W x D) 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 7.65 lb (3.43 kg) Power and heat numbers Module current—3.45 A Module power—144.90 W AC-input power—181.13 W AC heat dissipation—618.54 BTU/hour DC-input power—194.76 W DC heat dissipation—665.10 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
2-50 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10/100 and 10/100/1000 Ethernet Modules WS-X6548-GE-TX, WS-X6548-GE-45AF, and WS-X6548V-GE-TX Ethernet Modules The WS-X6548-GE-TX Ethernet module and its variants, listed in Table 2-33, provide 48 10/100/1000-Mbps full- or half-duplex ports. Figure 2-15 shows the module front panel. Figure 2-15 WS-X6548-GE-TX Ethernet Module Front Panel Table 2-34 lists the features and descriptions for the modules, and Table 2-35 lists the physical and environmental specifications for the modules. Table 2-33 WS-X6548-GE-TX Ethernet Module Variants Module Description WS-X6548-GE-TX Base module without daughter cards installed. WS-X6548-GE-45AF Base module equipped with a factory-installed IEEE 802.3af PoE daughter card (WS-F6K-GE48-AF). WS-X6548V-GE-TX Base module equipped with a factory-installed Cisco prestandard PoE daughter card (WS-F6K-VPWR-GE). 184596 WS-X6548-GE-TX STATUS 48 PORT10/100/1000 BASE-T GESWITCHING MODULE123456789101112131415161718192021222324252627282930313233343536373839404142434445464748PHONE 1 211 1213 1423 2425 2635 3637 3847 48 Table 2-34 WS-X6548-GE-TX Modules Features Feature Description Ports per module 48 (all variants). Ports are numbered (left to right): –Top row, odd-numbered ports 1–47. –Bottom row, even-numbered ports 2–48. 2 port groups Port ranges per port group: 1–24, 25–48 Port connector type RJ-45 (all variants) Cabling distance 328 ft (100 m) over Category 5, 5e, and 6 UTP/STP cable (all variants) Buffer size 1.4 MB per 8 ports QoS Number of egress queues: 3 Number of ingress queues: 1 Number of thresholds per egress queue: 2 Number of thresholds per ingress queue: 2 Maximum frame size Up to 1518 bytes per frame Module oversubscription rate N/A