1-15 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506 Switch Table 1-7 Catalyst 6506 Switch Features Feature Descriptions Chassis Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom). Power supplies Supports one or two power supplies. The following power supplies are supported: –WS-CAC-1000W (1000 W AC-input power supply) –WS-CAC-1300W (1300 W AC-input power supply) –WS-CDC-1300W (1300 W DC-input power supply) –WS-CAC-2500W (2500 W AC-input power supply) –WS-CDC-2500W (2500 W DC-input power supply) –WS-CAC-3000W (3000 W AC-input power supply) –WS-CAC-4000W-US (4000 W AC-input power supply) –WS-CAC-4000W-INT (4000 W AC-input power supply) –PWR-4000-DC (4000 W DC-input power supply) –WS-CAC-6000W (6000 W AC-input power supply) –WS-CAC-8700W (8700 W AC-input power supply) NoteThe 6000 W and the 8700 W AC-input power supplies are limited to 4500 W maximum output when installed in the Catalyst 6506 chassis. NoteFor information and specifications for each of the supported power supplies, refer to Appendix A, “Power Supply Specifications,” in the Catalyst 6500 Series Switches Installation Guide. Installed power supplies can be of different wattage ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or nonredundant mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay. You must install a 2500 W or higher capacity power supply when using the Supervisor Engine 32 or the Supervisor Engine 720 and the high-speed fan tray.
1-16 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506 Switch Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE. –Supervisor Engine 2 is installed in slot 1 or slot 2. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE are installed in slot 5 or slot 6. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, and Supervisor Engine 720-10GE all require the high-speed fan tray (WS-C6K-6SLOT-FAN2) be installed in the chassis. You must also install a 2500 W or higher capacity power supply in the chassis to power the high-speed fan tray. NoteThe 2500 W power supply, when supporting the high-speed fan tray, can be powered from either 120 VAC or 220 VAC. –Supervisor Engine 720 and Supervisor Engine 720-10GE have built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported by Supervisor Engine 720 and Supervisor Engine 720-10GE and cannot be installed in the same chassis. –Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Table 1-7 Catalyst 6506 Switch Features (continued) Feature Descriptions
1-17 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506 Switch ModulesChassis supports up to five Catalyst 6500 series modules. WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be installed in slot 5 or slot 6. Some Catalyst 6500 series modules: –Are not supported –Require that you install a Supervisor Engine 720 –Have chassis slot restrictions –Require a specific software release level Check your software release notes for specific information on supported modules. Table 1-8 Catalyst 6506 Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storage–4° to 149°F (–20° to 65°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 10% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m) Table 1-7 Catalyst 6506 Switch Features (continued) Feature Descriptions
1-18 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506 Switch Physical Characteristics Dimensions (H x W x D)20.1 x 17.2 x 18.1 in. (51.1 x 43.7 x 46.0 cm). Chassis depth including cable guide is 21.64 in. (55.0 cm). Chassis requires 12 RU. Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Weight Chassis only: 45 lb (20.4 kg). Chassis fully configured with 1 supervisor engine, 5 switching modules, and 2 power supplies: 156.6 lb (71.0 kg). Airflow WS-C6K-6SLOT-FAN (Standard fan tray)—227 CFM. WS-C6K-6SLOT-FAN2 (Optional high-speed fan tray)—420 CFM. NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. Table 1-8 Catalyst 6506 Switch Specifications (continued) Item Specification
1-19 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506-E Switch Catalyst 6506-E Switch The Catalyst 6506-E switch is an enhanced version of the Catalyst 6506 chassis. Figure 1-8 shows a front view of the chassis. Ta b l e 1 - 9 provides a description of the major switch features. Table 1-10 lists the specifications of the Catalyst 6506-E switch chassis. Figure 1-8 Catalyst 6506-E Switch 18224 INPUT OKFA N OKOUTPUT FA I L o INPUT OKFA N OKOUTPUT FA I L o 1 2 3 FA N STATUS 4 5 68 P O R T G IG A B IT E TH E R N E TWS-X64081LINKSTA TUS2 3 4 5 6 7 8LINKLINKLINKLINKLINKLINKLINK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 5 6 7 8LI NKLINKLINKLIN KLI NKLI NKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 5 6 7 8LI NKLINKLINKLIN KLI NKLI NKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LINKSTA TUS2 3 4 5 6 7 8LINKLINKLINKLINKLINKLINKLINKW S - S U P 32 -G E-3 BST AT U S SYSTEM ACT IVE PW R MGM T R ESETC ATA LY S T 65 00 SUP ER V IS O R E N G IN E 3 2CONSOL E EJEC TD ISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 POR T 6 PO RT 7PO RT 8POR T 9 USB 2.0 LIN K L INK L I NK LI NK LI NK LI NK LINK LIN K LINKW S -S U P 32- G E-3 BS T AT U S SYSTEM ACT IVE PW R MG M T R ESETC AT A LY S T 65 00 S UP ER V IS O R E N G IN E 3 2CONSOLE EJECTDISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PO RT 7PO RT 8POR T 9 USB 2.0 LINK L IN K L I NK LI NK LI N K LI NK LINK LINK LINK Fan assembly Supervisor engine Redundant supervisor engine Switching modules Power supply 2 (redundant)Power supply 1 ESD ground strap connector
1-20 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506-E Switch Table 1-9 Catalyst 6506-E Switch Features Feature Descriptions Chassis Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom). Power supplies Supports one or two power supplies. The following power supplies are supported: –WS-CAC-2500W (2500 W AC-input power supply) –WS-CDC-2500W (2500 W DC-input power supply) –WS-CAC-3000W (3000 W AC-input power supply) –WS-CAC-4000W-US (4000 W AC-input power supply) –WS-CAC-4000W-INT (4000 W AC-input power supply) –PWR-4000-DC (4000 W DC-input power supply) –WS-CAC-6000W (6000 W AC-input power supply) –WS-CAC-8700W-E (8700 W AC-input power supply) NoteFor information and specifications for each of the supported power supplies, refer to Appendix A, “Power Supply Specifications,” in the Catalyst 6500 Series Switches Installation Guide. Installed power supplies can be of different wattage ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or nonredundant mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. The Supervisor Engine 2T requires a 3000 W or greater power supply to operate. Single power supplies are installed in the left power supply bay. The second power supply is installed in the right power supply bay.
1-21 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506-E Switch Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T. –Supervisor Engine 2 is installed in slot 1 and slot 2. –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T are installed in slot 5 and slot 6. –Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have built-in switching fabric; Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported. –Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules ((WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Modules Chassis supports up to five Catalyst 6500 series modules. WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be installed in slot 5 or slot 6. Some Catalyst 6500 series modules: –Are not supported –Require that you install a Supervisor Engine 720 –Have chassis slot restrictions –Require a specific software release level Check your software release notes for specific information on module support and restrictions. Table 1-9 Catalyst 6506-E Switch Features (continued) Feature Descriptions
1-22 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506-E Switch Table 1-10 Catalyst 6506-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storage–4° to 149°F (–20° to 65°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 10% to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m) Physical Characteristics Dimensions (H x W x D)19.2 x 17.5 x 18.2 in. (48.8 x 44.5 x 46.0 cm). Chassis depth including cable guide is 21.64 in. (55.0 cm). Chassis requires 12 RU. Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Weight Chassis only: 45 lb (20.41 kg). Chassis fully configured with 1 supervisor engine, 5 switching modules, and 2 power supplies: 159 lb (72.3 kg). AirflowWS-C6506-E-FAN—564 CFM. NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side.
1-23 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6509 Switch Catalyst 6509 Switch The Catalyst 6509 switch is a 9-slot horizontal chassis. Figure 1-9 shows a front view of the chassis. Table 1-11 provides a description of the major switch features. Table 1-12 lists the specifications of the Catalyst 6509 switch chassis. Figure 1-9 Catalyst 6509 Switch 16076 INPUT OKFA N OKOUTPUT FA I L o INPUT OKFA N OKOUTPUT FA I L o 1 2 3 4 5 6 7 8 9 Power supply 2 (redundant)Power supply 1 ESD ground strap connector 8 PORT GIGABIT ETHER NET WS-X64081L IN KSTATUS2 3 4 5 6 7 8LIN KLIN KL IN KLIN KLIN KL INKL IN K 8 PORT GIGABIT ETHER NET WS-X64081LIN KSTATUS2 3 4 5 6 7 8LINKLINKL IN KLINKLINKLINKLINK 8 PORT GIGABIT ETHER NET WS-X64081L INKSTA TUS2 3 4 5 6 7 8LIN KL INKL INKL IN KLIN KLIN KL IN K 8 PORT GIGABIT ETHERNET WS-X64081LIN KSTATUS2 3 4 5 6 7 8LINKLINKLIN KLINKLINKLINKLINK 8 P O RT GIG A BIT ETHE R NET W S -X 6 4 0 81LINKSTATUS2 34 56 78LINKLINKLINKLINKLINKLINKLINK 24 POR T 1 00FX WS-X6224S T AT U S 2 4 P O R T 1 0 0 F X W S - X 6 2 2 4S T AT U S 1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK 1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK1 0LINK1 1LINK1 2LINK1 3LINK1 4LINK1 5LINK1 6LINK1 7LINK1 8LINK1 9LINK2 0LINK2 1LINK2 2LINK2 3LINK2 4LINK WS-SUP32-GE-3BSTA TUS SYSTEM ACTIVE PWR MGMT RESETCATALYST 6500 SUPERVIS OR ENGINE 32CONSOLE EJECTDISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PORT 7PORT 8PORT 9 USB 2.0 LINK LINK LINK LINK LINK LINK LINK LINK LINKWS-SUP32-G E-3BSTA TUS SYSTEM ACTIVE PWR MGMT RESETCATALYST 6500 SUPERVIS OR ENGINE 32CONSOLE EJECTDISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PORT 7PORT 8PORT 9 USB 2.0 LINK LINK LINK LINK LINK LINK LINK LINK LINK Switching modules Switching modules Fan assembly Supervisor engine Redundant supervisor engine
1-24 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6509 Switch Table 1-11 Catalyst 6509 Switch Features Feature Description Chassis Nine horizontal slots. Slots are numbered from 1 (top) to 9 (bottom). Power supplies Supports one or two power supplies. The following power supplies are supported: –WS-CAC-1000W (1000 W AC-input power supply) –WS-CAC-1300W (1300 W AC-input power supply) –WS-CDC-1300W (1300 W DC-input power supply) –WS-CAC-2500W (2500 W AC-input power supply) –WS-CDC-2500W (2500 W DC-input power supply) –WS-CAC-3000W (3000 W AC-input power supply) –WS-CAC-4000W-US (4000 W AC-input power supply) –WS-CAC-4000W-INT (4000 W AC-input power supply) –PWR-4000-DC (4000 W DC-input power supply) –WS-CAC-6000W (6000 W AC-input power supply) –WS-CAC-8700W-E (8700 W AC-input power supply) NoteThe 6000 W and the 8700 W AC-input power supplies are limited to 4500 W maximum output when installed in the Catalyst 6509 chassis. NoteFor information and specifications for each of the supported power supplies, refer to Appendix A, “Power Supply Specifications,” in the Catalyst 6500 Series Switches Installation Guide. Installed power supplies can be of different wattage ratings. Installed power supplies can also be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or nonredundant mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the left power supply bay. The second (redundant) power supply is installed in the right power supply bay. You must install a 2500 W or higher capacity power supply when using the Supervisor Engine 32 or the Supervisor Engine 720 and the high-speed fan tray.