    							1-15
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506 Switch
    Table 1-7 Catalyst 6506 Switch Features 
    Feature Descriptions
    Chassis Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom).
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
     –WS-CAC-1000W (1000 W AC-input power supply)
     –WS-CAC-1300W (1300 W AC-input power supply)
     –WS-CDC-1300W (1300 W DC-input power supply)
     –WS-CAC-2500W (2500 W AC-input power supply)
     –WS-CDC-2500W (2500 W DC-input power supply)
     –WS-CAC-3000W (3000 W AC-input power supply)
     –WS-CAC-4000W-US (4000 W AC-input power supply)
     –WS-CAC-4000W-INT (4000 W AC-input power supply)
     –PWR-4000-DC (4000 W DC-input power supply)
     –WS-CAC-6000W (6000 W AC-input power supply)
     –WS-CAC-8700W (8700 W AC-input power supply)
    NoteThe 6000 W and the 8700 W AC-input power supplies are limited to 
    4500 W maximum output when installed in the Catalyst 6506 
    chassis.
    NoteFor information and specifications for each of the supported power 
    supplies, refer to Appendix  A, “Power Supply Specifications,” in the 
    Catalyst 6500 Series Switches Installation Guide.
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or nonredundant mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    Single power supplies are installed in the left power supply bay. The 
    second power supply is installed in the right power supply bay.
    You must install a 2500 W or higher capacity power supply when using 
    the Supervisor Engine 32 or the Supervisor Engine 720 and the 
    high-speed fan tray. 
    						
    							1-16
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506 Switch
    Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, Supervisor Engine 720, and Supervisor 
    Engine 720-10GE. 
     –Supervisor Engine 2 is installed in slot 1 or slot 2. 
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine  720, and Supervisor Engine  720-10GE are installed in slot  5 
    or slot 6.
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE all require the 
    high-speed fan tray (WS-C6K-6SLOT-FAN2) be installed in the 
    chassis. You must also install a 2500 W or higher capacity power 
    supply in the chassis to power the high-speed fan tray.
    NoteThe 2500 W power supply, when supporting the high-speed fan tray, 
    can be powered from either 120 VAC or 220 VAC.
     –Supervisor Engine 720 and Supervisor Engine 720-10GE have 
    built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM 
    and WS-X6500-SFM2) are not supported by Supervisor Engine  720 
    and Supervisor Engine 720-10GE and cannot be installed in the 
    same chassis.
     –Supervisor Engine 32 and Supervisor Engine 32 PISA do not 
    support the Switch Fabric Modules (WS-C6500-SFM and 
    WS-X6500-SFM2).
    The uplink ports are fully functional on the redundant supervisor engine 
    in standby mode. 
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Table 1-7 Catalyst 6506 Switch Features (continued)
    Feature Descriptions 
    						
    							1-17
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506 Switch
    ModulesChassis supports up to five Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    Some Catalyst 6500 series modules:
     –Are not supported
     –Require that you install a Supervisor Engine 720
     –Have chassis slot restrictions
     –Require a specific software release level
    Check your software release notes for specific information on supported 
    modules.
    Table 1-8 Catalyst 6506 Switch Specifications 
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storage–4° to 149°F (–20° to 65°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 10% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
    Table 1-7 Catalyst 6506 Switch Features (continued)
    Feature Descriptions 
    						
    							1-18
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506 Switch
    Physical Characteristics
    Dimensions (H x W x D)20.1 x 17.2 x 18.1 in. (51.1 x 43.7 x 46.0 cm).
    Chassis depth including cable guide is 21.64 in. (55.0 cm). 
    Chassis requires 12 RU.
    Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D 
    and ETS 300-119 standards.
    Weight
    Chassis only: 45 lb (20.4 kg).
    Chassis fully configured with 1 supervisor engine, 5  switching modules, 
    and 2 power supplies: 156.6 lb (71.0 kg).
    Airflow
    WS-C6K-6SLOT-FAN (Standard fan tray)—227 CFM.
    WS-C6K-6SLOT-FAN2 (Optional high-speed fan tray)—420 CFM.
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15  cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side. 
    Table 1-8 Catalyst 6506 Switch Specifications (continued)
    Item Specification 
    						
    							1-19
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506-E Switch
    Catalyst 6506-E Switch
    The Catalyst 6506-E switch is an enhanced version of the Catalyst 6506 chassis. Figure 1-8 shows a 
    front view of the chassis. Ta b l e  1 - 9 provides a description of the major switch features. Table 1-10 lists 
    the specifications of the Catalyst 6506-E switch chassis. 
    Figure 1-8 Catalyst 6506-E Switch 
    18224
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    1
    2
    3
    FA N
    STATUS
    4
    5
    68
     P
    O
    R
    T G
    IG
    A
    B
    IT
     
    E
    TH
    E
    R
    N
    E
    TWS-X64081LINKSTA
    TUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKLINKLINKLINKLINK
    8
     P
    O
    R
    T G
    IG
    A
    B
    IT
     E
    TH
    E
    R
    N
    E
    TWS-X64081LIN
    KSTA
    TUS2
    3
    4
    5
    6
    7
    8LI
    NKLINKLINKLIN
    KLI
    NKLI
    NKLI
    NK
    8
     P
    O
    R
    T G
    IG
    A
    B
    IT
     E
    TH
    E
    R
    N
    E
    TWS-X64081LIN
    KSTA
    TUS2
    3
    4
    5
    6
    7
    8LI
    NKLINKLINKLIN
    KLI
    NKLI
    NKLI
    NK
    8
     P
    O
    R
    T G
    IG
    A
    B
    IT
     E
    TH
    E
    R
    N
    E
    TWS-X64081LINKSTA
    TUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKLINKLINKLINKLINKW
    S
    -
    S
    U
    P
    32
    -G
    E-3
    BST
    AT
    U
    S
    SYSTEM
    ACT
    IVE
    PW
    R MGM
    T
    R
    ESETC
    ATA
    LY
    S
    T   
    65
    00 
    SUP
    ER
    V
    IS
    O
    R
      E
    N
    G
    IN
    E
      3
    2CONSOL
    E
    EJEC
    TD
    ISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    POR
    T 6
    PO
    RT 7PO
    RT 8POR
    T
     9
    USB 2.0
    LIN
    K
    L
    INK
    L
    I
    NK
    LI
    NK
    LI
    NK
    LI
    NK
    LINK
    LIN
    K
    LINKW
    S
    -S
    U
    P
    32-
    G
    E-3
    BS
    T
    AT
    U
    S
    SYSTEM
    ACT
    IVE
    PW
    R MG
    M
    T
    R
    ESETC
    AT
    A
    LY
    S
    T   
    65
    00
     
    S
    UP
    ER
    V
    IS
    O
    R
      E
    N
    G
    IN
    E
      3
    2CONSOLE
    EJECTDISK 0PORT 1
    PORT
     2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PO
    RT 7PO
    RT 8POR
    T 9
    USB 
    2.0
    LINK
    L
    IN
    K
    L
    I
    NK
    LI
    NK
    LI
    N
    K
    LI
    NK
    LINK
    LINK
    LINK
    Fan assembly
    Supervisor engine
    Redundant supervisor
    engine Switching
    modules
    Power supply 2
    (redundant)Power supply 1
    ESD ground strap 
    connector 
    						
    							1-20
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506-E Switch
    Table 1-9 Catalyst 6506-E Switch Features 
    Feature Descriptions
    Chassis Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom).
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
     –WS-CAC-2500W (2500 W AC-input power supply)
     –WS-CDC-2500W (2500 W DC-input power supply)
     –WS-CAC-3000W (3000 W AC-input power supply)
     –WS-CAC-4000W-US (4000 W AC-input power supply)
     –WS-CAC-4000W-INT (4000 W AC-input power supply)
     –PWR-4000-DC (4000 W DC-input power supply)
     –WS-CAC-6000W (6000 W AC-input power supply)
     –WS-CAC-8700W-E (8700 W AC-input power supply)
    NoteFor information and specifications for each of the supported power 
    supplies, refer to Appendix  A, “Power Supply Specifications,” in the 
    Catalyst 6500 Series Switches Installation Guide.
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or nonredundant mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    The Supervisor Engine 2T requires a 3000  W or greater power supply to 
    operate.
    Single power supplies are installed in the left power supply bay. The 
    second power supply is installed in the right power supply bay. 
    						
    							1-21
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506-E Switch
    Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine  32 PISA, Supervisor Engine  720, Supervisor Engine  720-10GE, 
    and Supervisor Engine 2T. 
     –Supervisor Engine 2 is installed in slot 1 and slot 2.
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, Supervisor Engine 720-10GE, and Supervisor 
    Engine 2T are installed in slot 5 and slot 6.
     –Supervisor Engine 720, Supervisor Engine 720-10GE, and 
    Supervisor Engine 2T have built-in switching fabric; Switch Fabric 
    Modules (WS-C6500-SFM and WS-X6500-SFM2) are not 
    supported.
     –Supervisor Engine 32 and Supervisor Engine 32 PISA do not 
    support the Switch Fabric Modules ((WS-C6500-SFM and 
    WS-X6500-SFM2).
    The uplink ports are fully functional on the redundant supervisor engine 
    in standby mode. 
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Modules
    Chassis supports up to five Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    Some Catalyst 6500 series modules:
     –Are not supported
     –Require that you install a Supervisor Engine 720
     –Have chassis slot restrictions
     –Require a specific software release level
    Check your software release notes for specific information on module 
    support and restrictions.
    Table 1-9 Catalyst 6506-E Switch Features (continued)
    Feature Descriptions 
    						
    							1-22
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6506-E Switch
    Table 1-10 Catalyst 6506-E Switch Specifications 
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storage–4° to 149°F (–20° to 65°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 10% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
    Physical Characteristics
    Dimensions (H x W x D)19.2 x 17.5 x 18.2 in. (48.8 x 44.5 x 46.0 cm).
    Chassis depth including cable guide is 21.64 in. (55.0 cm). 
    Chassis requires 12 RU.
    Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D 
    and ETS 300-119 standards.
    Weight Chassis only: 45 lb (20.41 kg).
    Chassis fully configured with 1 supervisor engine, 5  switching modules, and 
    2 power supplies: 159 lb (72.3 kg).
    AirflowWS-C6506-E-FAN—564 CFM.
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15  cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side.  
    						
    							1-23
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509 Switch
    Catalyst 6509 Switch
    The Catalyst 6509 switch is a 9-slot horizontal chassis. Figure 1-9 shows a front view of the chassis. 
    Table 1-11 provides a description of the major switch features. Table 1-12 lists the specifications of the 
    Catalyst 6509 switch chassis. 
    Figure 1-9 Catalyst 6509 Switch
    16076
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    1
    2
    3
    4
    5
    6
    7
    8
    9
    Power supply 2
    (redundant)Power supply 1
    ESD ground strap
    connector
    8 PORT GIGABIT ETHER
    NET
    WS-X64081L
    IN
    KSTATUS2
    3
    4
    5
    6
    7
    8LIN
    KLIN
    KL
    IN
    KLIN
    KLIN
    KL
    INKL
    IN
    K
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LIN
    KSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKL
    IN
    KLINKLINKLINKLINK
    8 PORT GIGABIT ETHER
    NET
    WS-X64081L
    INKSTA
    TUS2
    3
    4
    5
    6
    7
    8LIN
    KL
    INKL
    INKL
    IN
    KLIN
    KLIN
    KL
    IN
    K
    8 PORT GIGABIT ETHERNET
    WS-X64081LIN
    KSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLIN
    KLINKLINKLINKLINK
    8 P
    O
    RT GIG
    A
    BIT
     ETHE
    R
    NET
    W
    S
    -X
    6
    4
    0
    81LINKSTATUS2
    34
    56
    78LINKLINKLINKLINKLINKLINKLINK
    24 POR
    T 1
    00FX
    WS-X6224S
    T
    AT
    U
    S
    2
    4
     P
    O
    R
    T
     1
    0
    0
    F
    X
    W
    S
    -
    X
    6
    2
    2
    4S
    T
    AT
    U
    S
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK1
    0LINK1
    1LINK1
    2LINK1
    3LINK1
    4LINK1
    5LINK1
    6LINK1
    7LINK1
    8LINK1
    9LINK2
    0LINK2
    1LINK2
    2LINK2
    3LINK2
    4LINK
    WS-SUP32-GE-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINKWS-SUP32-G
    E-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    Switching
    modules
    Switching
    modules
    Fan assembly
    Supervisor engine
    Redundant supervisor
    engine 
    						
    							1-24
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509 Switch
    Table 1-11 Catalyst 6509 Switch Features 
    Feature Description
    Chassis Nine horizontal slots. Slots are numbered from 1 (top) to 9 (bottom).
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
     –WS-CAC-1000W (1000 W AC-input power supply)
     –WS-CAC-1300W (1300 W AC-input power supply)
     –WS-CDC-1300W (1300 W DC-input power supply)
     –WS-CAC-2500W (2500 W AC-input power supply)
     –WS-CDC-2500W (2500 W DC-input power supply)
     –WS-CAC-3000W (3000 W AC-input power supply)
     –WS-CAC-4000W-US (4000 W AC-input power supply)
     –WS-CAC-4000W-INT (4000 W AC-input power supply)
     –PWR-4000-DC (4000 W DC-input power supply)
     –WS-CAC-6000W (6000 W AC-input power supply)
     –WS-CAC-8700W-E (8700 W AC-input power supply)
    NoteThe 6000 W and the 8700 W AC-input power supplies are limited to 
    4500 W maximum output when installed in the Catalyst 6509 
    chassis.
    NoteFor information and specifications for each of the supported power 
    supplies, refer to Appendix  A, “Power Supply Specifications,” in the 
    Catalyst 6500 Series Switches Installation Guide.
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or nonredundant mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    Single power supplies are installed in the left power supply bay. The 
    second (redundant) power supply is installed in the right power supply 
    bay.
    You must install a 2500 W or higher capacity power supply when using 
    the Supervisor Engine 32 or the Supervisor Engine 720 and the 
    high-speed fan tray. 
    						
    All Cisco manuals Comments (0)

    Related Manuals for Cisco 6509 E Installation Manual