1-5 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6503 Switch Table 1-2 Catalyst 6503 Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storage–4° to 149°F (–20° to 65°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 10% to 85% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m) Physical Characteristics Dimensions (H x W x D)7 x 17.37 x 21.75 in. (17.78 x 44.12 x 55.25 cm). Chassis requires 4 RU. Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Weight Chassis only: 27 lb (12.25 kg). Chassis fully configured with 1 supervisor engine, 2 modules, 2 AC-input PEMs, and 2 AC-input power supplies: 85.4 lb (38.7 kg). Airflow FAN-MOD-3 (standard fan tray)—170 CFM FAN-MOD-3HS (optional high-speed fan tray)—270 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side.
1-6 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6503-E Switch Catalyst 6503-E Switch The Catalyst 6503-E switch is an enhanced version of the Catalyst 6503. Figure 1-3 shows the front view of the chassis and Figure 1-4 shows the rear view of the chassis. Ta b l e 1 - 3 provides a description of the major switch features. Table 1-4 lists the specifications of the Catalyst 6503-E switch chassis. Figure 1-3 Catalyst 6503-E Switch—Front View Figure 1-4 Catalyst 6503-E Switch—Rear View 91239 Slots 1-3 (top to bottom) Fan assemblyPEM 1 PEM 2 ESD ground strap connection Supervisor Engine Modules W S-X 6516-G E-T X 16 PO RT 1000 BA SE-T G E1234567 8910 111213 141516 LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK W S -X6516-G E-T X 16 P O RT 1000 B AS E-T G E12345 67 8910 111213 141516 LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK W S-S UP 32-G E-3B ST A T US SYST EM ACT IVE PWR MGMT RESETCAT ALYST 6500 SUPER VIS OR ENGI NE 32CO NSO LE EJECTDIS K 0PORT 1 PO RT 2 PO RT 3 P O RT 4PO RT 5 PO RT 6 PO RT 7PO R T 8P O RT 9 USB 2. 0 LI NK LINK LI NK LI NK LI NK LINK LI NK LIN K LINK 63031 INPUT OKFA N OKOUTPUT FA I L INPUT OKFA N OKOUTPUT FA I L Power supply 2 (redundant) Power supply 1
1-7 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6503-E Switch Table 1-3 Catalyst 6503-E Switch Features Feature Description Chassis Three horizontal slots. Slots are numbered from 1 (top) to 3 (bottom). Power supplies Supports one or two power supplies. The following power supplies are supported: –PWR-950-AC (950 W AC-input power supply) –PWR-950-DC (950 W DC-input power supply) –PWR-1400-AC (1400 W AC-input power supply) NoteFor information and specifications for each of the supported power supplies, refer to Appendix A, “Power Supply Specifications,” in the Catalyst 6500 Series Switches Installation Guide. Installed power supplies can be of different wattage ratings. Installed power supplies can be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or nonredundant mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Supervisor Engine 2T requires a 1400 W power supply to operate. Single power supplies are installed in the lower power supply bay. The second power supply is installed in the upper power supply bay.
1-8 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6503-E Switch Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T. –Supervisor engines are installed in slot 1 and slot 2. –Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have built-in switching fabric and do not support Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). –Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules ((WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine when it is in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Modules Chassis supports up to two Catalyst 6500 series modules. Chassis does not support the WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules. Some Catalyst 6500 series modules: –Are not supported –Require that you install a Supervisor Engine 720 or Supervisor Engine 2T –Have chassis slot restrictions –Require a specific software release level Check your software release notes for specific information on module support and restrictions. Table 1-3 Catalyst 6503-E Switch Features (continued) Feature Description
1-9 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6503-E Switch Table 1-4 Catalyst 6503-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storage–4° to 149°F (–20° to 65°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 10% to 85% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m) Physical Characteristics Dimensions (H x W x D)7 x 17.37 x 21.75 in. (17.78 x 44.12 x 55.25 cm). Chassis requires 4 RU. Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Weight Chassis only: 33 lb (15 kg). Chassis fully configured with 1 supervisor engine, 2 modules, 2 AC-input PEMs, and 2 AC-input power supplies: 85.4 lb (38.7 kg). AirflowWS-C6503-E-FAN—282 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 15 cm (6-inch) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side.
1-10 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6504-E Switch Catalyst 6504-E Switch The Catalyst 6504-E switch is a 4-slot horizontal enhanced chassis. Figure 1-5 shows the front view of the chassis and Figure 1-6 shows the rear view of the chassis. Ta b l e 1 - 5 provides a description of major switch features. Ta b l e 1 - 6 lists the specifications of the Catalyst 6504-E switch chassis. Figure 1-5 Catalyst 6504-E Switch—Front View Figure 1-6 Catalyst 6504-E Switch—Rear View 126559 STATUS FAN STATUS STATUS Slots 1-4 (top to bottom) Supervisor Engine OSMs Redundant Supervisor Engine 126560 P W R -2700-AC INPUT OKFA N OKOUTPUT FAIL ALL F ASTENERS MUST BE FULLY ENGAGED PRIOR TO OPERATING THE POWER SUPP LY 100-240 V-16A 50/60Hz P W R -2700-AC INPUT OKF AN OKOUTPUT FAIL ALL F ASTEN ERS M UST BE FULLY ENGA G ED PRIOR TO OPER A TING THE P OW ER SUPPL Y 100-240V-16A 50/60Hz Power Supply 1Power Supply 2 (redundant)
1-11 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6504-E Switch Table 1-5 Catalyst 6504-E Switch Features Feature Description Chassis Four horizontal slots. Slots are numbered from 1 (top) to 4 (bottom). Power supplies Supports one or two power supplies. The following power supplies are supported: –PWR-2700-AC/4 (2700 W AC-input power supply) –PWR-2700-DC/4 (2700 W DC-input power supply) NoteFor information and specifications for each of the supported power supplies, refer to Appendix A, “Power Supply Specifications,” in the Catalyst 6500 Series Switches Installation Guide. Installed power supplies can be both AC-input, both DC-input, or one AC-input and one DC-input. Power supplies can be configured in either redundant or nonredundant mode. All Catalyst 6500 series AC-input power supplies require single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. Single power supplies are installed in the lower power supply bay. The second power supply is installed in the upper power supply bay.
1-12 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6504-E Switch Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T. –Supervisor engines are installed in slot 1 and slot 2. –Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported by those supervisor engines. –Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules ((WS-C6500-SFM and WS-X6500-SFM2). The uplink ports are fully functional on the redundant supervisor engine when it is in standby mode. NoteIn systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. Modules Chassis supports up to three Catalyst 6500 series modules. Chassis does not support the WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules. Some Catalyst 6500 series modules: –Are not supported –Require that you install a Supervisor Engine 720 or Supervisor Engine 2T –Have chassis slot restrictions –Require a specific software release level Check your software release notes for specific information on module support and restrictions. Table 1-5 Catalyst 6504-E Switch Features (continued) Feature Description
1-13 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6504-E Switch Table 1-6 Catalyst 6504-E Switch Specifications Item Specification Environmental Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) NoteThe Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. Temperature, nonoperating and storage–4° to 149°F (–20° to 65°C) Thermal transition 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) Humidity (RH), ambient (noncondensing) operating 10% to 85% Humidity (RH), ambient (noncondensing) nonoperating and storage 5% to 95% Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m) Physical Characteristics Dimensions (H x W x D)8.7 x 17.5 x 21.6 in. (22.09 x 44.45 x 54.86 cm). Chassis requires 5 RU. Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Weight Chassis only: 27 lb (12.25 kg). Chassis fully configured with 2 supervisor engines, 2 modules, and 2 AC-input power supplies: 97 lb (43.99 kg). AirflowFAN-MOD-4HS—300 CFM NoteTo maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side.
1-14 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 1 Catalyst 6500 Series Switch Chassis Overview Catalyst 6506 Switch Catalyst 6506 Switch The Catalyst 6506 switch is a 6-slot horizontal chassis. Figure 1-7 shows a front view of the chassis. Table 1-7 provides a description of the major switch features. Ta b l e 1 - 8 lists the specifications of the Catalyst 6506 switch chassis. Figure 1-7 Catalyst 6506 Switch 18224 INPUT OKFA N OKOUTPUT FA I L o INPUT OKFA N OKOUTPUT FA I L o 1 2 3 FA N STATUS 4 5 68 P O R T G IG A B I T E TH E R N E TWS-X64081LINKSTA TUS2 3 4 56 7 8LINKLINKLINKLINKLINKLINKLINK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 5 6 7 8LI NKLINKLINKLIN KLI NKLINKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LIN KSTA TUS2 3 4 56 7 8LI NKLINKLINKLIN KLI NKLINKLI NK 8 P O R T G IG A B IT E TH E R N E TWS-X64081LINKSTA TUS2 3 4 5 6 7 8LINKLINKLINKLINKLINKLINKLINKW S - S U P 32 -G E-3 BST AT U S SYS TEM ACTIVE PW R MGM T R ESE TC ATA LY S T 65 00 SUP ER V IS O R E N G IN E 3 2CONSOLE EJEC TDISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 POR T 6 PO RT 7PO RT 8POR T 9 USB 2.0 LIN K L INK L I NK LI NK LI NK LI NK LI NK LIN K LINKW S -S U P 32 -G E-3 BST AT U S SYSTEM ACTIVE PW R MG M T R ESETC AT A LY S T 65 00 S UP ER V IS O R E N G IN E 3 2CONSOL E EJECTDISK 0PORT 1 PORT 2 PORT 3 PORT 4PORT 5 PORT 6 PO RT 7PO RT 8POR T 9 USB 2.0 LINK L IN K L I NK LI NK LI N K LI NK LI NK LINK LINK Fan assembly Supervisor engine Redundant supervisor engine Switching modules Power supply 2 (redundant)Power supply 1 ESD ground strap connector