Home > Cisco > Ethernet Switch > Cisco 6509 E Installation Manual

Cisco 6509 E Installation Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Cisco 6509 E Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							B-15
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      10-GB Transceivers
    Ta b l e  B - 1 6 lists the fiber loss budgets for the 10-GB X2 transceivers.
    Ta b l e  B - 1 7 lists the physical and environmental specifications for the X2 transceiver.
    SFP+ Transceivers
    10-Gigabit SFP+ transceivers are supported by the Virtual Switching Supervisor Engine 720 
    (VS-S720-10G-3C and VS-S720-10G-3CXL) and the WS-X6904-40G Ethernet module (with the use of 
    FourX converter modules). The supervisor engine has two 10-Gigabit ports on the the front panel. The 
    two ports normally accepts X2 10-Gigabit transceivers. By installing a OneX converter module 
    (CVR-X2-SFP10G) in the port, the port can accept a 10-Gigabit SFP+ transceiver. For general 
    information, compatibility matrix, and installation instructions for the SFP+ transceiver, see the 
    following publications:
    For general information on the 10-Gigabit SFP+ transceiver modules including models and 
    specifications, see the Cisco 10GBASE SFP+ Modules Data Sheet at the following URL:
    http://www.cisco.com/en/US/prod/collateral/modules/ps5455/data_sheet_c78-455693.html
    Ta b l e  B - 1 6 X 2  Tr a n s c e i v e r  O p t i c a l  Transmit and Receive Specifications 
    X2 Transceiver Product 
    NumberTransmit Power (dBm) Receive Power (dBm)
    X2-10GB-LRM 0.5 (max)
    –6.5 (min)0.5 (max)
    –8.4 (min) (In average)
    1
    –6.4 (min) (in Optical Modulation 
    Amplitude (OMA))
    1. Both the average and the OMA specifications must be met simultaneously.
    X2-10GB-SR –1.2 (max)2
    –7.3 (min)
    2. The launch power shall be the lesser of the class 1 safety limit or the maximum receive power. Class 1 laser requirements are 
    defined by IEC 60825: 2001.
    –1.0 (max)
    –9.9 (min)
    X2-10GB-LR 0.5 (max)
    –8.2 (min)0.5 (max)
    –14.4 (min)
    X2-10GB-ER 4.0 (max)
    –4.7 (min)–1.0 (max)
    –15.8 (min)
    X2-10GB-LX4 –0.5 per lane (max)
    –6.75 per lane –0.5 (max)
    –14.4 per lane
    Table B-17 10-GB X2 Transceiver Physical and Environmental Specifications
    Item Specification
    Dimensions (H x W x D) 0.53 x 1.41 x 3.58 in. (13.46 x 36 x 91 mm)
    Operating temperature
    Storage temperature32° to 104°F (0° to 40°C)
    –40° to 167°F (–40° to 75°C) 
    						
    							B-16
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      40-Gigabit Transceivers
    For details on which modules support the 10-Gigabit SFP+ transceiver module and software 
    requirements, see the Cisco 10-Gigabit Ethernet Transceiver Modules Compatibility Matrix at the 
    following URL:
    http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/
    OL_6974.html
    For 10-Gigabit SFP+ transceiver installation instructions, see the Cisco SFP and SFP+ Transceiver 
    Module Installation Notes at the following URL:
    http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/installation/note/78_1
    5160.html
    For general information on the OneX converter, see the Cisco OneX Converter Module data sheet at 
    the following URL:
    http://www.cisco.com/en/US/prod/collateral/modules/ps5455/data_sheet_c78-547521.html
    40-Gigabit Transceivers
    40-Gigabit CFP transceivers are supported by the WS-X6904-40G Ethernet module. The module accepts 
    up to four of the 40-Gigabit CFP transceivers in slots on the module front panel. For general information, 
    compatibility matrix, and installation instructions, see the following publications:
    For general information, including specifications and optical characteristics, on the 40-Gigabit CFP 
    transceiver modules, see the Cisco 40GBASE CFP Modules Data Sheet at the following URL:
    http://www.cisco.com/en/US/prod/collateral/modules/ps5455/data_sheet_c78-702617.html
    For 40-Gigabit CFP transceiver module compatibility information, see the Cisco 40-Gigabit 
    Ethernet Transceiver Modules Compatibility Matrix at the following URL:
    http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/
    OL_24900.html
    For 40-Gigabit CFP transceiver module installation instructions, see the Cisco 40-Gigabit and 
    100-Gigabit CFP transceiver Modules Installation Note at the following URL:
    http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/installation/note/OL_2
    3946.html
    WDM Transceivers 
    The WDM transceiver modules are listed in Table B-18 along with brief descriptions of the transceiver 
    modules and illustration references. 
    						
    							B-17
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers
    Table B-18 WDM Transceivers 
    WDM Transceiver 
    Ty p eDescription Supported on these 
    Modules1WDM 
    Transceiver 
    IllustrationWDM Transceiver 
    Specification 
    Ta b l e
    CWDM  GBIC The CWDM GBIC transceivers provide 
    1000BASE-X full-duplex connectivity 
    between the GBIC-compatible 
    modules, supervisor engines, and the 
    network. A set of eight CWDM GBICs 
    are available for use with the CWDM 
    Passive Optical System. The CWDM 
    GBIC transceivers have a duplex SC 
    connector.
    WS-X6408A-GBIC
    WS-X6416-GBIC
    WS-X6516-GBIC
    WS-X6516A-GBIC
    WS-X6816-GBICFigure B-9 Table B-19
    DWDM GBIC DWDM GBIC transceivers are used as 
    part of a DWDM optical network to 
    provide high-capacity bandwidth across 
    an fiber-optic network. There are 32 
    fixed-wavelength DWDM GBICs that 
    support the International 
    Telecommunications Union (ITU) 
    100-GHz wavelength grid. The DWDM 
    GBIC transceivers have a duplex SC 
    connector.
    WS-X6408A-GBIC
    WS-X6416-GBIC
    WS-X6516-GBIC
    WS-X6516A-GBIC
    WS-X6816-GBICFigure B-10 Table B-20
    R/O WDM GBIC The R/O WDM GBIC receiver 
    (WDM-GBIC-REC) operates as a 
    pluggable receiver on any 
    unidirectional link in a CWDM or 
    DWDM transport network; there is no 
    transmitter in the GBIC. The receiver 
    can be used for all wavelengths 
    supported by Cisco CWDM and 
    DWDM transceivers and can be used 
    interchangeably with 1000BASE-SX, 
    1000BASE-LX/LH, and 
    1000BASE-ZX transceivers on a 
    port-by-port basis. The W/O WDM 
    receiver has a single SC connector.
    WS-X6408A-GBIC
    WS-X6416-GBIC
    WS-X6516-GBIC
    WS-X6516A-GBIC
    WS-X6816-GBIC—— 
    						
    							B-18
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers
    CWDM SFP The Coarse Wavelength Division 
    Multiplexing (CWDM) SFPs are 
    hot-swappable, transceiver components 
    that you plug into SFP-compatible 
    modules and supervisor engines. The 
    CWDM SFP transceiver uses an LC 
    optical connector to connect to 
    single-mode fiber-optic (SMF) cable. 
    You can connect the CWDM SFPs to 
    CWDM passive optical system 
    add/drop multiplexer (OADM) modules 
    or multiplexer/demultiplexer plug-in 
    modules using single-mode fiber-optic 
    cables. WS-X6724-SFP
    WS-X6748-SFPFigure B-11 Table B-21
    DWDM  XENPAK DWDM XENPAK transceivers are used 
    as part of a DWDM optical network to 
    provide high-capacity bandwidth across 
    an fiber-optic network. There are 32 
    fixed-wavelength DWDM XENPAK 
    transceivers that support the 
    International Telecommunications 
    Union (ITU) 100  GHz wavelength grid. 
    The DWDM XENPAK transceivers 
    have a duplex SC connector.
    WS-X6704-10GEFigure B-12 Table B-22
    R/O WDM 
    XENPAKThe R/O WDM XENPAK receiver 
    (WDM-XENPAK-REC) operates as a 
    pluggable receiver on any 
    unidirectional link in a CWDM or 
    DWDM transport network; there is no 
    transmitter in the XENPAK. The 
    receiver can be used for all wavelengths 
    supported by Cisco DWDM XENPAK 
    transceivers. The W/O WDM receiver 
    has a single SC connector. 
    WS-X6704-10GE — —
    1. Not all WDM transceivers may be supported on the modules. Refer to your software release notes for specific information on which WDM transceivers 
    are supported and the software release level necessary to support them.
    Table B-18 WDM Transceivers (continued)
    WDM Transceiver 
    Ty p eDescription Supported on these 
    Modules1WDM 
    Transceiver 
    IllustrationWDM Transceiver 
    Specification 
    Ta b l e 
    						
    							B-19
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers
    Figure B-9 CWDM GBIC Transceiver
    Figure B-10 DWDM GBIC Transceiver Module
    1Color arrow on label5Optical bore dust plug
    2Alignment groove6Receive optical bore
    3Spring clip7Color dot
    4Transmit optical bore
    Table B-19 CWDM GBIC Transceivers Wavelengths 
    Model Number Color Code CWDM GBIC Wavelength
    CWDM-GBIC-1470= Gray 1470 nm laser single-mode
    CWDM-GBIC-1490= Violet 1490 nm laser single-mode
    CWDM-GBIC-1510= Blue 1510 nm laser single-mode
    CWDM-GBIC-1530= Green 1530 nm laser single-mode
    CWDM-GBIC-1550= Yellow 1550 nm laser single-mode
    CWDM-GBIC-1570= Orange 1570 nm laser single-mode
    CWDM-GBIC-1590= Red 1590 nm laser single-mode
    CWDM-GBIC-1610= Brown 1610 nm laser single-mode
    SINGLE-MODE1000BASE-CWDM GBIC
    CWDM-GBIC-1550=2
    5
    6
    17
    3484472
    36494
    Receiver Transmitter 
    						
    							B-20
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers
    Table B-20 DWDM GBIC Transceiver Product Numbers and ITU Channel Numbers 
    DWDM GBIC 
    Product NumberDescription ITU Channel
    DWDM-GBIC-60.61 1000BASE-DWDM 1560.61 nm GBIC 21
    DWDM-GBIC-59.79 1000BASE-DWDM 1559.79 nm GBIC 22
    DWDM-GBIC-58.98 1000BASE-DWDM 1558.98 nm GBIC 23
    DWDM-GBIC-58.17 1000BASE-DWDM 1558.17 nm GBIC 24
    DWDM-GBIC-56.55 1000BASE-DWDM 1556.55 nm GBIC 26
    DWDM-GBIC-55.75 1000BASE-DWDM 1555.75 nm GBIC 27
    DWDM-GBIC-54.94 1000BASE-DWDM 1554.94 nm GBIC 28
    DWDM-GBIC-54.13 1000BASE-DWDM 1554.13 nm GBIC 29
    DWDM-GBIC-52.52 1000BASE-DWDM 1552.52 nm GBIC 31
    DWDM-GBIC-51.72 1000BASE-DWDM 1551.72 nm GBIC 32
    DWDM-GBIC-50.92 1000BASE-DWDM 1550.92 nm GBIC 33
    DWDM-GBIC-50.12 1000BASE-DWDM 1550.12 nm GBIC 34
    DWDM-GBIC-48.51 1000BASE-DWDM 1548.51 nm GBIC 36
    DWDM-GBIC-47.72 1000BASE-DWDM 1547.72 nm GBIC 37
    DWDM-GBIC-46.92 1000BASE-DWDM 1546.92 nm GBIC 38
    DWDM-GBIC-46.12 1000BASE-DWDM 1546.12 nm GBIC 39
    DWDM-GBIC-44.53 1000BASE-DWDM 1544.53 nm GBIC 41
    DWDM-GBIC-43.73 1000BASE-DWDM 1543.73 nm GBIC 42
    DWDM-GBIC-42.94 1000BASE-DWDM 1542.94 nm GBIC 43
    DWDM-GBIC-42.14 1000BASE-DWDM 1542.14 nm GBIC 44
    DWDM-GBIC-40.56 1000BASE-DWDM 1540.56 nm GBIC 46
    DWDM-GBIC-39.77 1000BASE-DWDM 1539.77 nm GBIC 47
    DWDM-GBIC-39.98 1000BASE-DWDM 1539.98 nm GBIC 48
    DWDM-GBIC-38.19 1000BASE-DWDM 1538.19 nm GBIC 49
    DWDM-GBIC-36.61 1000BASE-DWDM 1536.61 nm GBIC 51
    DWDM-GBIC-35.82 1000BASE-DWDM 1535.82 nm GBIC 52
    DWDM-GBIC-35.04 1000BASE-DWDM 1535.04 nm GBIC 53
    DWDM-GBIC-34.25 1000BASE-DWDM 1534.25 nm GBIC 54
    DWDM-GBIC-32.68 1000BASE-DWDM 1532.68 nm GBIC 56
    DWDM-GBIC-31.90 1000BASE-DWDM 1531.90 nm GBIC 57
    DWDM-GBIC-31.12 1000BASE-DWDM 1531.12 nm GBIC 58
    DWDM-GBIC-30.33 1000BASE-DWDM 1530.33 nm GBIC 59 
    						
    							B-21
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers
    Figure B-11 CWDM SFP Transceiver Table B-21 CWDM SFP Transceivers 
    Model Number Color Code CWDM GBIC Wavelength
    CWDM-SFP-1470= Gray 1470 nm laser, single-mode
    CWDM-SFP-1490= Violet 1490 nm laser, single-mode
    CWDM-SFP-1510= Blue 1510 nm laser, single-mode
    CWDM-SFP-1530= Green 1530 nm laser, single-mode
    CWDM-SFP-1550= Yellow 1550 nm laser, single-mode
    CWDM-SFP-1570= Orange 1570 nm laser, single-mode
    CWDM-SFP-1590= Red 1590 nm laser, single-mode
    CWDM-SFP-1610= Brown 1610 nm laser, single-mode
    Table B-22 DWDM XENPAK Transceiver Module Product Numbers and 
    ITU Channel Numbers 
    DWDM XENPAK 
    Product NumberDescription ITU Channel
    DWDM-XENPAK-60.61 1000BASE-DWDM 1560.61 nm 
    XENPAK21
    DWDM-XENPAK-59.79 1000BASE-DWDM 1559.79 nm 
    XENPAK22
    DWDM-XENPAK-58.98 1000BASE-DWDM 1558.98 nm 
    XENPAK23
    DWDM-XENPAK-58.17 1000BASE-DWDM 1558.17 nm 
    XENPAK24
    DWDM-XENPAK-56.55 1000BASE-DWDM 1556.55 nm 
    XENPAK26
    DWDM-XENPAK-55.75 1000BASE-DWDM 1555.75 nm 
    XENPAK27
    DWDM-XENPAK-54.94 1000BASE-DWDM 1554.94 nm 
    XENPAK28
    113753
    CWDM
    -SFP-1470-2GClass 1 21CFR1040.10
    LN#50 7/01         03-13
    S/N: OH1233456
    Color arrow on label
    Receive optical bore
    Transmit optical bore
    Bail clasp Dustplug  
    						
    							B-22
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers
    DWDM-XENPAK-54.13 1000BASE-DWDM 1554.13 nm 
    XENPAK29
    DWDM-XENPAK-52.52 1000BASE-DWDM 1552.52 nm 
    XENPAK31
    DWDM-XENPAK-51.72 1000BASE-DWDM 1551.72 nm 
    XENPAK32
    DWDM-XENPAK-50.92 1000BASE-DWDM 1550.92 nm 
    XENPAK33
    DWDM-XENPAK-50.12 1000BASE-DWDM 1550.12 nm 
    XENPAK34
    DWDM-XENPAK-48.51 1000BASE-DWDM 1548.51 nm 
    XENPAK36
    DWDM-XENPAK-47.72 1000BASE-DWDM 1547.72 nm 
    XENPAK37
    DWDM-XENPAK-46.92 1000BASE-DWDM 1546.92 nm 
    XENPAK38
    DWDM-XENPAK-46.12 1000BASE-DWDM 1546.12 nm 
    XENPAK39
    DWDM-XENPAK-44.53 1000BASE-DWDM 1544.53 nm 
    XENPAK41
    DWDM-XENPAK-43.73 1000BASE-DWDM 1543.73 nm 
    XENPAK42
    DWDM-XENPAK-42.94 1000BASE-DWDM 1542.94 nm 
    XENPAK43
    DWDM-XENPAK-42.14 1000BASE-DWDM 1542.14 nm 
    XENPAK44
    DWDM-XENPAK-40.56 1000BASE-DWDM 1540.56 nm 
    XENPAK46
    DWDM-XENPAK-39.77 1000BASE-DWDM 1539.77 nm 
    XENPAK47
    DWDM-XENPAK-39.98 1000BASE-DWDM 1539.98 nm 
    XENPAK48
    DWDM-XENPAK-38.19 1000BASE-DWDM 1538.19 nm 
    XENPAK49
    DWDM-XENPAK-36.61 1000BASE-DWDM 1536.61 nm 
    XENPAK51
    DWDM-XENPAK-35.82 1000BASE-DWDM 1535.82 nm 
    XENPAK52
    DWDM-XENPAK-35.04 1000BASE-DWDM 1535.04 nm 
    XENPAK53
    Table B-22 DWDM XENPAK Transceiver Module Product Numbers and 
    ITU Channel Numbers (continued)
    DWDM XENPAK 
    Product NumberDescription ITU Channel 
    						
    							B-23
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers
    Figure B-12 DWDM XENPACK Transceiver 
    DWDM-XENPAK-34.25 1000BASE-DWDM 1534.25 nm 
    XENPAK54
    DWDM-XENPAK-32.68 1000BASE-DWDM 1532.68 nm 
    XENPAK56
    DWDM-XENPAK-31.90 1000BASE-DWDM 1531.90 nm 
    XENPAK57
    DWDM-XENPAK-31.12 1000BASE-DWDM 1531.12 nm 
    XENPAK58
    DWDM-XENPAK-30.33 1000BASE-DWDM 1530.33 nm 
    XENPAK59
    Table B-22 DWDM XENPAK Transceiver Module Product Numbers and 
    ITU Channel Numbers (continued)
    DWDM XENPAK 
    Product NumberDescription ITU Channel
    1Captive installation screw2Dustplug
    3Transmit optical bore4Receive optical bore
    2
    99376
    RX
    TX
    1
    34 
    						
    							B-24
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Appendix B      Pluggable Transceiver Modules
      WDM Transceivers 
    						
    All Cisco manuals Comments (0)

    Related Manuals for Cisco 6509 E Installation Manual