C-1 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 APPENDIXC ESD Precautions Revised: July 2011 This appendix provides information on preventing ESD when removing and installing modules in a chassis. Attaching Your ESD Grounding Strap Electrostatic discharge (ESD) damage, which can occur when modules or other FRUs are improperly handled, results in intermittent or complete failures. Modules consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, always use an ESD grounding strap when handling modules. For preventing ESD damage, follow these guidelines: Always use an ESD wrist strap and ensure that it makes maximum contact with bare skin. ESD grounding straps are available with banana plugs, metal spring clips, or alligator clips. All Catalyst 6500 series chassis are equipped with a banana plug connector (identified by the ground symbol next to the connector) somewhere on the front panel. –If you have an older Catalyst 6500 series chassis equipped with a plastic banana plug connector, we recommend that you use either the supplied ESD grounding wrist strap (with a metal clip) or an ESD grounding wrist strap equipped with an alligator clip. –If you have a newer Catalyst 6500 series chassis that has a bare metal hole as the banana plug connector (also identified by the ground symbol next to the hole), we recommend that you use a personal ESD grounding strap equipped with a banana plug. If you choose to use the disposable ESD wrist strap supplied with most FRUs or an ESD wrist strap equipped with an alligator clip, you must attach the system ground lug to the chassis in order to provide a proper grounding point for the ESD wrist strap. NoteThis system ground is also referred to as the network equipment building system (NEBS) ground. If your chassis does not have the NEBS system ground attached, you must install the system ground lug and a ground wire. Refer to the online Catalyst 6500 Series Switches Installation Guide for the procedure.
C-2 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Appendix C ESD Precautions Attaching Your ESD Grounding Strap After you install the system ground lug, follow these steps to correctly attach the ESD wrist strap: Step 1Attach the ESD wrist strap to bare skin as follows: a.If you are using the ESD wrist strap supplied with the FRUs, open the wrist strap package and unwrap the ESD wrist strap. Place the black conductive loop over your wrist and tighten the strap so that it makes good contact with your bare skin. b.If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove the ESD wrist strap. Locate the end of the wrist strap that attaches to your body and secure it to your bare skin. Step 2Grasp the spring or alligator clip on the ESD wrist strap and momentarily touch the clip to a bare metal spot (unpainted surface) on the rack. We recommend that you touch the clip to an unpainted rack rail so that any built-up static charge is then safely dissipated to the entire rack. Step 3Attach either the spring clip or the alligator clip to the ground lug screw as follows (See Figure C-1): a.If you are using the ESD wrist strap that is supplied with the FRUs, squeeze the spring clip jaws open, position the spring clip to one side of the system ground lug screw head, and slide the spring clip over the lug screw head so that the spring clip jaws close behind the lug screw head. NoteThe spring clip jaws do not open wide enough to fit directly over the head of the lug screw or the lug barrel. b.If you are using an ESD wrist strap that is equipped with an alligator clip, attach the alligator clip directly over the head of the system ground lug screw or to the system ground lug barrel.
C-3 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Appendix C ESD Precautions Attaching Your ESD Grounding Strap Figure C-1 Attaching the ESD Wrist Strap Clip to the System Ground Lug Screw In addition, follow these guidelines when handling modules: Handle carriers by available handles or edges only; avoid touching the printed circuit boards or connectors. Place a removed component board-side-up on an antistatic surface or in a static-shielding container. If you plan to return the component to the factory, immediately place it in a static-shielding container. Never attempt to remove the printed circuit board from the metal carrier. CautionFor safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohm (Mohm). SUPERVISOR2 WS-X6K-SUP2-2GESTATUSSYSTEMCONSOLEPWR MGMTRESETC O N S O LEC ON SO LE PO R T M O DEP C M C IA EJE CTP O R T 1PO R T 2S w itch Loa d 100% 1 % LINK LINKO S M -4 O C 1 2 P O S -S I 4 P O R T O C -1 2 P O S S M IRS T A T U S 1 1 2 23 3 4 4R E S E T L I N K L IN KL I N K L I N K C A R R I E R A L A R M C A R R I E R A L A R M C A R R I E R A L A R M C A R R I E R A L A R M A C T I V E T X R X T X P O R T 1 R X A C T I V E T X R X T X P O R T 2 R XA C T I V E T X R X T X P O R T 3 R XA C T IV E T X R X T X P O R T 4 R X O S M - 4 O C 1 2 P O S -S I 4 P O R T O C -1 2 P O S S M IR S T A T U S 1 1 2 23 3 4 4R E S E T L I N K L I N KL I N K L I N K C A R R I E R A L A R M C A R R I E R A L A R M C A R R I E R A L A R M C A R R I E R A L A R M A C T I V E T X R X T X P O R T 1 R X A C T I V E T X R X T X P O R T 2 R XA C T I V E T X R X T X P O R T 3 R XA C T I V E T X R X T X P O R T 4 R X 144607 System ground connector Grounding lug Side view of grounding lug ESD ground strap Slide clip behind screw Clip installed behind screwClip Screw
C-4 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Appendix C ESD Precautions Attaching Your ESD Grounding Strap
IN-1 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 INDEX Numerics 10/100 and 10/100/1000BASE modules WS-X6148A-GE-TX 2-14 to 2-19 WS-X6148E-GE-45AT 2-29 to 2-31 WS-X6148-GE-TX 2-14 to 2-19 WS-X6148-RJ21 2-19 to 2-22 WS-X6148-RJ-45 2-23 to 2-28 WS-X6148X2-RJ-45 2-32 to 2-36 WS-X6196-RJ-21 2-37 to 2-40 WS-X6348-RJ21V 2-41 to 2-43 WS-X6348-RJ45 2-43 to 2-46 WS-X6516-GE-TX 2-47 to 2-49 WS-X6548-GE-TX 2-50 to 2-53 WS-X6548-RJ-21 2-54 to 2-57 WS-X6548-RJ-45 2-57 to 2-60 WS-X6748-GE-TX 2-61 to 2-66 WS-X6848-TX-2T/-2TXL 2-61 to 2-66 100-MB SFP transceivers B-1 to B-3 10 and 10/100 fiber-based modules See WS-X6024-10FL-MT See WS-X6148-FE-SFP See WS-X6324-100FX-MM See WS-X6324-100FX-SM See WS-X6524-100FX-MM 10-GB modules WS-X6704-10GE 2-93 to 2-97 WS-X6708-10G-3C 2-98 to 2-101 WS-X6708-10G-3CXL 2-98 to 2-101 WS-X6716-10G-3C 2-102 to 2-108 WS-X6716-10G-3CXL 2-102 to 2-108 WS-X6716-10T-3C 2-108 to 2-114 WS-X6716-10T-3CXL 2-108 to 2-114 WS-X6816-10G-2T/-2TXL 2-102 to 2-108 WS-X6816-10T-2T/-2TXL 2-108 to 2-114 WS-X6908-10G 2-114 to 2-117 10-GB transceivers B-8 to B-15 X2 transceivers B-8 to B-15 modules supported on B-8 optical transmit and receive specifications B-15 physical and environmental specifications table B-15 XENPAK transceivers B-8 to B-11 modules supported on B-8 physical form (figure) B-9 polish face types supported B-9 specifications and cabling distances table B-10 1-GB modules WS-X6408A-GBIC 2-67 to 2-69 WS-X6416-GBIC 2-70 to 2-72 WS-X6516A-GBIC 2-73 to 2-77 WS-X6516-GBIC 2-73 to 2-77 WS-X6724-SFP 2-78 to 2-83 WS-X6748-SFP 2-83 to 2-89 WS-X6816-GBIC 2-89 to 2-92 WS-X6824-SFP-2T/-2TXL 2-78 to 2-83 WS-X6848-SFP-2T/-2TXL 2-83 to 2-89 1-GB transceivers See either GBIC transceivers or SFP transceivers 40-GB modules WS-X6904-40G 2-118 to 2-122 A attenuators, using with 1000BASE-ZX GBIC B-5 audience, document 1-v
Index IN-2 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 B blank module carriers 3-6 C Catalyst 6503-E switches airflow 1-9 altitude, operating 1-9 chassis, dimensions 1-9 environmental specifications 1-9 fantrays supported 1-9 features table 1-6 form factor, front view (figure) 1-6 form factor, rear view (figure) 1-6 humidity, operating 1-9 physical characteristics 1-9 slot numbering 1-7 specifications table 1-6 supervisor engines supported 1-8 temperature, operating 1-9 weight 1-9 Catalyst 6503 switches airflow 1-5 altitude, operating 1-5 chassis, dimensions 1-5 environmental specifications 1-5 fan trays supported 1-5 features table 1-2 form factor, front view (figure) 1-2 form factor, rear view (figure) 1-2 humidity, operating 1-5 physical characteristics 1-5 slot numbering 1-3 specifications table 1-2 supervisor engines supported 1-4 temperature, operating 1-5 weight 1-5 Catalyst 6504-E switches airflow 1-13 altitude, operating 1-13 chassis, dimensions 1-13 environmental specifications 1-13 fan trays supported 1-13 features table 1-10 form factor, front view (figure) 1-10 form factor, rear view (figure) 1-10 humidity, operating 1-13 physical characteristics 1-13 slot numbering 1-11 specifications table 1-10 supervisor engines supported 1-12 temperature, operating 1-13 weight 1-13 Catalyst 6506-E switches airflow 1-22 altitude, operating 1-22 chassis dimensions 1-22 environmental specifications 1-22 fan trays supported 1-22 features table 1-19 form factor (figure) 1-19 humidity, operating 1-22 physical characteristics 1-22 slot numbering 1-20 specifications table 1-19 supervisor engines 1-21 temperature, operating 1-22 weight 1-22 Catalyst 6506 switches airflow 1-18 altitude, operating 1-17 chassis, dimensions 1-18 environmental specifications 1-17 fan trays supported 1-18 features table 1-14 form factor (figure) 1-14 humidity, operating 1-17
Index IN-3 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 physical characteristics 1-18 slot numbering 1-15 specifications 1-14 supervisor engines supported 1-16 temperature, operating 1-17 weight 1-18 Catalyst 6509-E switches airflow 1-31 altitude, operating 1-31 chassis dimensions 1-31 environmental specifications 1-31 fan trays supported 1-31 features table 1-28 form factor (figure) 1-28 humidity, operating 1-31 physical characteristics 1-31 slot numbering 1-29 specifications table 1-28 supervisor engines 1-30 temperature, operating 1-31 weight 1-31 Catalyst 6509-NEB-A switches airflow 1-39 altitude, operating 1-39 chassis dimensions 1-39 environmental specifications 1-39 fan trays supported 1-39 features table 1-36 form factor (figure) 1-36 humidity, operating 1-39 physical characteristics 1-39 specifications table 1-36 supervisor engines supported 1-38 temperature, operating 1-39 weight 1-39 Catalyst 6509-NEB switches airflow 1-35 altitude, operating 1-35 chassis dimensions 1-35 environmental specifications 1-35 fan trays supported 1-35 features table 1-32 form factor (figure) 1-32 humidity, operating 1-35 physical characteristics 1-35 slot numbering 1-33 specifications 1-32 supervisor engines supported 1-34 temperature, operating 1-35 weight 1-35 Catalyst 6509 switches airflow 1-27 altitude, operating 1-27 chassis, dimensions 1-27 environmental specifications 1-27 fan trays supported 1-27 features table 1-23 form factor (figure) 1-23 humidity, operating 1-27 physical characteristics 1-27 slot numbering 1-24 specifications table 1-23 supervisor engines supported 1-25 temperature, operating 1-27 weight 1-27 Catalyst 6509-V-E switches airflow 1-43 altitude, operating 1-43 chassis dimensions 1-43 environmental specifications 1-43 fan trays supported 1-43 features table 1-40 form factor (figure) 1-40 humidity, operating 1-43 physical characteristics 1-43 specifications table 1-40 supervisor engines supported 1-42 temperature, operating 1-43
Index IN-4 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 weight 1-43 Catalyst 6513-E switches airflow 1-53 altitude, operating 1-52 chassis dimensions 1-53 environmental specifications 1-52 fan trays supported 1-53 features table 1-49 form factor (figure) 1-49 humidity, operating 1-52 physical characteristics 1-53 slot numbering 1-50 specifications table 1-49 supervisor engines supported 1-51 temperature, operating 1-52 weight 1-53 Catalyst 6513 switches airflow 1-48 altitude, operating 1-48 chassis dimensions 1-48 environmental specifications 1-48 fan trays supported 1-48 features table 1-44 form factor (figure) 1-44 humidity, operating 1-48 physical characteristics 1-48 slot numbering 1-45 specifications table 1-44 supervisor engines supported 1-46 temperature, operating 1-48 weight 1-48 chassis Catalyst 6509-E switches 1-31 commands show module 3-16 show port 3-16 connectivity checking 3-17 conventions, documentation 1-vi CWDM GBIC transceivers description B-17 modules supported on B-17 physical form (figure) B-19 wavelength table B-19 CWDM SFP transceivers description B-18 modules supported on B-18 physical form (figure) B-21 product numbers and color codes B-21 D dimensions, chassis Catalyst 6503-E switches 1-9 Catalyst 6503 switches 1-5 Catalyst 6504-E switches 1-13 Catalyst 6506-E switches 1-22 Catalyst 6506 switches 1-18 Catalyst 6509-NEB-A switches 1-39 Catalyst 6509-NEB switches 1-35 Catalyst 6509 switches 1-27 Catalyst 6509-V-E switches 1-43 Catalyst 6513-E switches 1-53 Catalyst 6513 switches 1-48 documentation audience 1-v conventions 1-vi organization 1-v related 1-xiii DWDM GBIC transceivers description B-17 modules supported on B-17 physical form (figure) B-19 product numbers and ITU channel numbers B-20 DWDM XENPAK transceivers description B-18 modules supported on B-18
Index IN-5 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 physical form (figure) B-23 product numbers and ITU channel numbers B-21 E environmental specifications Catalyst 6503-E switches 1-9 Catalyst 6503 switches 1-5 Catalyst 6504-E switches 1-13 Catalyst 6506-E switches 1-22 Catalyst 6506 switches 1-17 Catalyst 6509-E switches 1-31 Catalyst 6509-NEB-A switches 1-39 Catalyst 6509-NEB switches 1-35 Catalyst 6509 switches 1-27 Catalyst 6509-V-E switches 1-43 Catalyst 6513-E switches 1-52 Catalyst 6513 switches 1-48 environmental specifications tables WS-X6516-GE-TX 2-49 WS-X6548-GE-TX 2-53 F features tables WS-X6024-10FL-MT 2-2 WS-X6148A-GE-TX 2-15 WS-X6148E-GE-45AT 2-29 WS-X6148-FE-SFP 2-4 WS-X6148-GE-TX 2-15 WS-X6148-RJ21 2-19 WS-X6148-RJ-45 2-24 WS-X6148X2-RJ-45 2-33 WS-X6196-RJ-21 2-37 WS-X6324-100FX-MM 2-7 WS-X6324-100FX-SM 2-7 WS-X6348-RJ21V 2-41 WS-X6348-RJ45 2-44 WS-X6408A-GBIC 2-67 WS-X6416-GBIC 2-70 WS-X6516A-GBIC 2-73 WS-X6516-GBIC 2-73 WS-X6516-GE-TX 2-47 WS-X6524-100FX-MM 2-10 WS-X6548-GE-TX 2-50 WS-X6548-RJ-21 2-54 WS-X6548-RJ-45 2-57 WS-X6704-10GE 2-93 WS-X6708-10G-3C 2-98 WS-X6708-10G-3CXL 2-98 WS-X6716-10G-3C 2-102 WS-X6716-10G-3CXL 2-102 WS-X6716-10T-3C 2-109 WS-X6716-10T-3CXL 2-109 WS-X6724-SFP 2-78 WS-X6748-GE-TX 2-61 WS-X6748-SFP 2-83 WS-X6816-10G-2T/-2TXL 2-102 WS-X6816-10T-2T/-2TXL 2-109 WS-X6816-GBIC 2-89 WS-X6824-SFP-2T/-2TXL 2-78 WS-X6848-SFP-2T/-2TXL 2-83 WS-X6848-TX-2T/-2TXL 2-61 WS-X6904-40G 2-119 WS-X6908-10G 2-114 fiber modules WS-X6024-10FL-MT 2-2 to 2-4 WS-X6148-FE-SFP 2-4 to 2-7 WS-X6324-100FX-MM 2-7 to 2-9 WS-X6324-100FX-SM 2-7 to 2-9 WS-X6524-100FX-MM 2-10 to 2-13 filler plate, module 3-6 G GBIC transceivers B-3 to B-8 attenuators B-5
Index IN-6 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 cabling specifications (table) B-4 modules supported on B-3 optical GBICs physical form (figure) B-4 WS-G5483 copper GBICs physical form (figure) B-4 M modules blank module carriers 3-6 O organization, document 1-v P physical and enviromental specifications tables transceivers 1-GB SFP transceivers B-8 physical and environmental specifications tables fiber modules WS-X6024-10FL-MT 2-4 transceivers 100-MB SFP transceivers B-3 GBIC transceivers B-6 X2 transceivers B-15 WS-X6148A-GE-TX 2-17 WS-X6148E-GE-45AT 2-31 WS-X6148-FE-SFP 2-6 WS-X6148-GE-TX 2-17 WS-X6148-RJ21 2-22 WS-X6148-RJ-45 2-27 WS-X6148X2-RJ-45 2-36 WS-X6196-RJ-21 2-40 WS-X6324-100FX-MM 2-9 WS-X6324-100FX-SM 2-9 WS-X6348-RJ21V 2-43 WS-X6348-RJ45 2-46 WS-X6408A-GBIC 2-69 WS-X6416-GBIC 2-72 WS-X6516A-GBIC 2-75 WS-X6516-GBIC 2-75 WS-X6524-100FX-MM 2-12 WS-X6548-RJ-21 2-56 WS-X6548-RJ-45 2-59 WS-X6704-10GE 2-96 WS-X6708-10G-3C 2-101 WS-X6708-10G-3CXL 2-101 WS-X6716-10G-3C 2-107 WS-X6716-10G-3CXL 2-107 WS-X6716-10T-3C 2-112 WS-X6716-10T-3CXL 2-112 WS-X6724-SFP 2-81 WS-X6748-GE-TX 2-64 WS-X6748-SFP 2-87 WS-X6816-10G-2T/-2TXL 2-107 WS-X6816-10T-2T/-2TXL 2-112 WS-X6816-GBIC 2-92 WS-X6824-SFP-2T/-2TXL 2-81 WS-X6848-SFP-2T/-2TXL 2-87 WS-X6848-TX-2T/-2TXL 2-64 WS-X6904-40G 2-121 WS-X6908-10G 2-116 physical characteristics Catalyst 6503-E switches 1-9 Catalyst 6503 switches 1-5 Catalyst 6504-E switches 1-13 Catalyst 6506-E switches 1-22 Catalyst 6506 switches 1-18 Catalyst 6509-E switches 1-31 Catalyst 6509-NEB-A switches 1-39 Catalyst 6509-NEB switches 1-35 Catalyst 6509 switches 1-27 Catalyst 6509-V-E switches 1-43 Catalyst 6513-E switches 1-53 Catalyst 6513 switches 1-48