    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509 Switch
    Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, Supervisor Engine 720, and Supervisor 
    Engine 720-10GE. 
     –Supervisor Engine 2 is installed in slot 1 and slot 2.
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine  720, and Supervisor Engine  720-10GE are installed in slot  5 
    and slot 6.
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE require that the 
    high-speed fan tray be installed in the chassis. You must also install 
    a 2500 W or higher capacity power supply in the chassis to power 
    the high-speed fan tray.
    NoteThe 2500 W power supply, when supporting the high-speed fan tray, 
    can be powered from either 120 VAC or 220 VAC.
     –Supervisor Engine 720 and Supervisor Engine 720-10GE have 
    built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM 
    and WS-X6500-SFM2) are not supported by Supervisor Engine  720 
    and Supervisor Engine 720-10GE and cannot be installed in the 
    same chassis.
     –Supervisor Engine 32 and Supervisor Engine 32 PISA do not 
    support the Switch Fabric Modules (WS-C6500-SFM and 
    WS-X6500-SFM2).
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode.
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Table 1-11 Catalyst 6509 Switch Features (continued)
    Feature Description 
    						
    							1-26
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509 Switch
    ModulesChassis supports up to eight Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    Some Catalyst 6500 series modules:
     –Are not supported
     –Require that you install a Supervisor Engine 720
     –Have chassis slot restrictions
     –Require a specific software release level
    Check your software release notes for specific information on supported 
    modules.
    Table 1-11 Catalyst 6509 Switch Features (continued)
    Feature Description 
    						
    							1-27
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509 Switch
    Table 1-12 Catalyst 6509 Switch Specifications 
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, ambient 
    nonoperating and storage–20° to 65°C (–4° to 149°F)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 10% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
    Physical Characteristics
    Dimensions (H x W x D)25.2 x 17.2 x 18.4 in. (64.0 x 43.7 x 46.7 cm).
    Chassis depth including cable guide is 21.64 in. (55.0 cm). 
    Chassis requires 15 RU.
    Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D 
    and ETS 300-119 standards.
    Weight Chassis only: 55 lb (24.9 kg).
    Chassis fully configured with 1 supervisor engine, 8  switching modules, and 
    2 power supplies: 194.5 lb (88.2 kg).
    Airflow
    WS-C6K-9SLOT-FAN (Standard fan tray)—340 CFM
    WS-C6K-9SLOT-FAN2 (Optional high-speed fan tray)—630 CFM
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15  cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side.  
    						
    							1-28
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509-E Switch
    Catalyst 6509-E Switch
    The Catalyst 6509-E switch is an enhanced version of the Catalyst 6509 chassis. Figure 1-10 shows a 
    front view of the chassis. Table 1-13 provides a description of the major switch features. Table 1-14 lists 
    the specifications of the Catalyst 6509-E switch chassis. 
    Figure 1-10 Catalyst 6509-E Switch 
    113676
    FA N
    STA
    TUS
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    1
    2
    3
    4
    5
    6
    7
    8
    9
    Power supply 2
    (redundant)Power supply 1
    ESD ground strap
    connector
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LIN
    KLINKLIN
    KLINKLINKLINKLINK
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LIN
    KSTATUS2
    3
    4
    5
    6
    7
    8LINKLINKLINKLINKLINKLINKLINK
    8 PORT GIGABIT ETHER
    NET
    WS-X64081LINKSTATUS2
    3
    4
    5
    6
    7
    8LIN
    KLINKLINKLIN
    KL
    INKLINKLINK
    8 PORT GIGABIT ETHERNET
    WS-X64081L
    INKSTATUS2
    3
    4
    5
    6
    7
    8LINKLIN
    KLIN
    KLINKLINKLIN
    KLINK
    8
     P
    OR
    T
     G
    IG
    ABIT
     E
    THE
    R
    N
    ET
    W
    S
    -X
    6
    4
    0
    81LINKS
    T
    AT
    U
    S2
    34
    56
    7
    8LINKLINKLINKLINKLINKLINKLINK
    24 PORT 1
    00FX
    WS-
    X6224STATUS
    2
    4
     P
    O
    R
    T
     1
    0
    0
    F
    X
    W
    S
    -X
    6
    2
    2
    4S
    T
    AT
    U
    S
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK10LINK11LINK12LINK13LINK14LINK15LINK16LINK17LINK18LINK19LINK20LINK21LINK22LINK23LINK24LINK
    1LINK2LINK3LINK4LINK5LINK6LINK7LINK8LINK9LINK1
    0LINK1
    1LINK1
    2LINK1
    3LINK1
    4LINK1
    5LINK1
    6LINK1
    7LINK1
    8LINK1
    9LINK2
    0LINK2
    1LINK2
    2LINK2
    3LINK2
    4LINK
    WS-SUP32-G
    E-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINKWS-SUP32-G
    E-3BSTA
    TUS
    SYSTEM
    ACTIVE
    PWR MGMT
    RESETCATALYST   6500 SUPERVIS
    OR  ENGINE  32
    CONSOLE
    EJECTDISK 0PORT 1
    PORT 2
    PORT 3
    PORT 4PORT 5
    PORT 6
    PORT 7PORT 8PORT 9
    USB 2.0
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    Switching
    modules
    Switching
    modules
    Fan assembly
    Supervisor engine
    Redundant supervisor
    engine 
    						
    							1-29
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509-E Switch
    Table 1-13 Catalyst 6509-E Switch Features 
    Feature Description
    Chassis Nine horizontal slots. Slots are numbered from (1) top to (9) bottom.
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
     –WS-CAC-2500W (2500 W AC-input power supply)
     –WS-CDC-2500W (2500 W DC-input power supply)
     –WS-CAC-3000W (3000 W AC-input power supply)
     –WS-CAC-4000W-US (4000 W AC-input power supply)
     –WS-CAC-4000W-INT (4000 W AC-input power supply)
     –PWR-4000-DC (4000 W DC-input power supply)
     –WS-CAC-6000W (6000 W AC-input power supply)
     –WS-CAC-8700W-E (8700 W AC-input power supply)
    NoteFor information and specifications for each of the supported power 
    supplies, refer to Appendix  A, “Power Supply Specifications,” in the 
    Catalyst 6500 Series Switches Installation Guide.
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or nonredundant mode.
    Supervisor Engine 2T requires a 3000 W or greater power supply to 
    operate.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated. 
    						
    							1-30
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509-E Switch
    Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine  32 PISA, Supervisor Engine  720, Supervisor Engine  720-10GE, 
    and Supervisor Engine 2T. 
     –Supervisor Engine 2 is installed in slot 1 and slot 2.
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, Supervisor Engine 720-10GE, and Supervisor 
    Engine 2T are installed in slot 5 and slot 6.
     –Supervisor Engine 720, Supervisor Engine 720-10GE, and 
    Supervisor Engine 2T have built-in switching fabric; Switch Fabric 
    Modules (WS-C6500-SFM and WS-X6500-SFM2) are not 
    supported.
     –Supervisor Engine 32 and Supervisor Engine 32 PISA do not 
    support the Switch Fabric Modules (WS-C6500-SFM and 
    WS-X6500-SFM2).
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode.
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Modules
    Chassis supports up to eight Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    Some Catalyst 6500 series modules:
     –Are not supported
     –Require that you install a Supervisor Engine 720 or Supervisor 
    Engine 2T
     –Have chassis slot restrictions
     –Require a specific software release level
    NoteCheck your software release notes for specific information on 
    module support and restrictions.
    Table 1-13 Catalyst 6509-E Switch Features (continued)
    Feature Description 
    						
    							1-31
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509-E Switch
    Table 1-14 Catalyst 6509-E Switch Specifications 
    Item Specification
    Environmental
    Temperature, operating Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    NoteThe Catalyst 6500 series switches are equipped with internal air 
    temperature sensors that are triggered at 104°F (40°C) generating a 
    minor alarm and at 131°F (55°C) generating a major alarm.
    Temperature, nonoperating 
    and storage–4° to 149°F (–20° to 65°C)
    Thermal transition 0.5°C per minute (hot to cold)
    0.33°C per minute (cold to hot)
    Humidity (RH), ambient 
    (noncondensing) operating 10% to 90%
    Humidity (RH), ambient 
    (noncondensing) 
    nonoperating and storage 5% to 95% 
    Altitude, operating Certified for operation: 0 to 6500 feet (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
    Physical Characteristics
    Dimensions (H x W x D)24.5 x 17.5 x 18.2 in. (62.2 x 44.5 x 46.0 cm).
    Chassis depth including cable guide is 21.64 in. (55.0 cm). 
    Chassis requires 15 RU.
    Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D 
    and ETS 300-119 standards.
    Weight Chassis only: 55 lb (24.9 kg).
    Chassis fully configured with 1 supervisor engine, 8  switching modules, and 
    2 power supplies: 135 lb (61.2 kg).
    AirflowWS-C6509-E-FAN—846 CFM
    NoteTo maintain proper air circulation through the Catalyst switch 
    chassis, we recommend that you maintain a minimum 6-inch (15  cm) 
    separation between a wall and the chassis air intake or a wall and the 
    chassis air exhaust. You should also allow a minimum separation of 
    12 inches (30.5 cm) between the hot air exhaust on one chassis and 
    the air intake on another chassis. Failure to maintain adequate air 
    space can cause the chassis to overheat and the system to fail. On 
    Catalyst chassis in which the airflow is from front to back, the 
    chassis may be placed side-by-side.  
    						
    							1-32
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509-NEB Switch
    Catalyst 6509-NEB Switch
    The Catalyst  6509-NEB switch is a 9-slot vertical chassis. Figure 1-11 shows a front view of the chassis. 
    Table 1-15 provides a description of the major switch features. Table 1-16 lists the specifications of the 
    Catalyst 6509-NEB switch chassis. 
    Figure 1-11 Catalyst 6509-NEB Switch
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    INPUT
    OKFA N
    OKOUTPUT
    FA I
    L
    o
    FA N
    STATUS
    30695
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTA
    TUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTA
    TUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTATUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTATUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    24 PORT 100FXWS-X6224STA
    TUS1LIN
    K2LIN
    K3LINK4LINK5LIN
    K6LIN
    K7LINK8LIN
    K9LINK1
    0LINK1
    1LIN
    K1
    2L
    IN
    K1
    3LINK1
    4LINK1
    5LIN
    K1
    6LIN
    K1
    7LIN
    K1
    8LIN
    K1
    9LINK2
    0LIN
    K2
    1L
    IN
    K2
    2LINK2
    3LIN
    K2
    4LINK
    Slots 1-9
    (right to left)
    Power supply 1Power supply 2
    (redundant)
    ESD ground strap
    connection
    W
    S
    -S
    U
    P32
    -GE
    -3
    BSTATUS
    SYST
    EM
    ACT
    IVE
    PWR
     MG
    MT
    RES
    ETC
    A
    T
    A
    L
    YS
    T
       6
    500
     S
    U
    P
    E
    RV
    IS
    O
    R
      E
    N
    G
    IN
    E
      32
    C
    O
    N
    S
    O
    L
    E
    E
    J
    EC
    TD
    IS
    K
     0P
    O
    R
    T
     1
    P
    O
    R
    T 2
    P
    O
    R
    T 3
    P
    O
    R
    T 4P
    O
    R
    T 5
    P
    O
    R
    T 6
    P
    O
    R
    T
     7P
    O
    R
    T 8P
    O
    R
    T 9
    U
    S
    B 2
    .0
    LIN
    K
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LIN
    K
    LINK
    W
    S
    -S
    U
    P32
    -G
    E
    -3
    BSTA
    TUS
    SYST
    EM
    ACT
    IVE
    PWR
     MG
    MT
    RES
    ETC
    A
    T
    A
    L
    YS
    T
       6
    500
     SU
    P
    E
    RV
    IS
    O
    R
      E
    N
    G
    IN
    E
      32
    C
    O
    N
    S
    O
    L
    E
    E
    J
    EC
    TD
    IS
    K
     0P
    O
    R
    T 1
    P
    O
    R
    T 2
    P
    O
    R
    T
     3
    P
    O
    R
    T 4P
    O
    R
    T
     5
    P
    O
    R
    T 6
    P
    O
    R
    T
     7P
    O
    R
    T 8P
    O
    R
    T 9
    U
    S
    B 2
    .0
    LIN
    K
    LIN
    K
    LIN
    K
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    8 PORT GIGABIT ETHER
    NETWS-X6408
    1LINKSTA
    TUS
    2
    3
    45
    6
    7
    8LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    LINK
    24 PORT 100FXWS-X6224STATUS1LIN
    K2LIN
    K3LINK4LI
    NK5L
    INK6LIN
    K7L
    INK8LINK9LIN
    K1
    0LIN
    K1
    1LINK1
    2LINK1
    3LIN
    K1
    4LIN
    K1
    5LINK1
    6LINK1
    7L
    IN
    K1
    8LINK1
    9LINK2
    0LIN
    K2
    1LINK2
    2LINK2
    3LINK2
    4LIN
    K
    Switching
    modules
    Fan
    assembly
    Supervisor
    engine
    Redundant
    supervisor
    engine 
    						
    							1-33
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509-NEB Switch
    Table 1-15 Catalyst 6509-NEB Switch Features 
    Feature Features
    Chassis Nine vertical slots. Slots are numbered from 1 (right) to 9 (left).
    Power supplies
    Supports one or two power supplies. The following power supplies are 
    supported:
     –WS-CAC-2500W (2500 W AC-input power supply)
     –WS-CDC-2500W (2500 W DC-input power supply)
     –WS-CAC-3000W (3000 W AC-input power supply)
     –WS-CAC-4000W-US (4000 W AC-input power supply)
     –WS-CAC-4000W-INT (4000 W AC-input power supply)
     –PWR-4000-DC (4000 W DC-input power supply)
     –WS-CAC-6000W (6000 W AC-input power supply)
     –WS-CAC-8700W-E (8700 W AC-input power supply)
    NoteThe 6000 W and the 8700 W AC-input power supplies are limited to 
    4500 W maximum output when installed in the Catalyst 6509-NEB 
    chassis.
    NoteFor information and specifications for each of the supported power 
    supplies, refer to Appendix  A, “Power Supply Specifications,” in the 
    Catalyst 6500 Series Switches Installation Guide.
    Installed power supplies can be of different wattage ratings. Installed 
    power supplies can also be both AC-input, both DC-input, or one 
    AC-input and one DC-input. Power supplies can be configured in either 
    redundant or nonredundant mode.
    All Catalyst 6500 series AC-input power supplies require single-phase 
    source AC. Source AC can be out of phase between multiple power 
    supplies or multiple AC-power plugs on the same power supply because 
    all AC power supply inputs are isolated.
    Single power supplies are installed in the left power supply bay. The 
    second power supply is installed in the right power supply bay. 
    						
    							1-34
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 1      Catalyst 6500 Series Switch Chassis Overview
      Catalyst 6509-NEB Switch
    Supervisor enginesSupports Supervisor Engine 2, Supervisor Engine 32, Supervisor 
    Engine 32 PISA, Supervisor Engine 720, and Supervisor 
    Engine 720-10GE.
     –Supervisor Engine 2 is installed in slot 1 or slot 2.
     –Supervisor Engine 32 is installed in slot 5 or slot 6.
    Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE are supported if the 
    WS-6509-NEB-UPGRD kit is installed.
     –Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor 
    Engine 720, and Supervisor Engine 720-10GE. are installed in 
    slot 5 or slot 6.
     –Supervisor Engine 720 and Supervisor Engine 720-10GE have 
    built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM 
    and WS-X6500-SFM2) are not supported by Supervisor Engine  720 
    and cannot be installed in the same chassis.
     –Supervisor Engine 32 and Supervisor Engine 32 PISA do not 
    support the Switch Fabric Modules ((WS-C6500-SFM and 
    WS-X6500-SFM2).
    The uplink ports are fully functional on all redundant supervisor engine 
    models when they are in standby mode. 
    NoteIn systems with redundant supervisor engines, both supervisor 
    engines must be the same model and have the same daughter card 
    configurations. Each supervisor engine must have the resources to 
    run the switch on its own, which means all supervisor engine 
    resources are duplicated. Identical supervisor engine memory 
    configurations are recommended, but are not required as long as the 
    supervisor engine with the smaller memory configuration is 
    sufficient to run the configured features of the switch. Additionally, 
    each supervisor engine must have its own flash device and console 
    port connections.
    Modules
    Chassis supports up to eight Catalyst 6500 series modules.
    WS-C6500-SFM and WS-X6500-SFM2 Switch Fabric Modules must be 
    installed in slot 5 or slot 6.
    Some Catalyst 6500 series modules:
     –Are not supported
     –Require that you install a Supervisor Engine 720
     –Have chassis slot restrictions
     –Require a specific software release level
    NoteCheck your software release notes for specific information on 
    module support and restrictions.
    Table 1-15 Catalyst 6509-NEB Switch Features (continued)
    Feature Features 
    						