Cisco 6509 E Installation Manual
Have a look at the manual Cisco 6509 E Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2-101 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules Table 2-57 WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Module Physical and Environmental Specifications Item Specification Dimensions 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 16.0 lb (7.26 kg) Power and heat numbers WS-X6708-10G-3C (base module + the DFC3C daughter card) –Module current—10.58 A –Module power—444.36 W –AC-input power—555.45 W –AC heat dissipation—1896.86 BTU/hour –DC-input power—597.26 W –DC heat dissipation—2039.64 BTU/hour WS-X6708-10G-3CXL (base module + the DFC3CXL daughter card) –Module current—11.28 A –Module power—473.76 W –AC-input power—592.20 W –AC heat dissipation—2022.36 BTU/hour –DC-input power—636.77 W –DC heat dissipation—2174.58 BTU/hour Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
2-102 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Modules The WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet modules (Figure 2-27) provide 16 10-Gbps full- or half-duplex ports. Table 2-58 lists the module features, and Table 2-59 lists the module physical and environmental specifications. NoteA sticker is placed on the module faceplate identifying it as either a WS-X6816-10G-2T or WS-X6816-10G-2TXL depending on whether a WS-F6K-DFC4-E or WS-F6K-DFC4-EXL daughter card is installed on the module. Figure 2-27 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Front Panel Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features Feature Description Ports per module 16 ports. Ports are numbered (left to right): –Top row, odd numbered ports 1 through 15. –Bottom row, even numbered ports 2 through 16. 4 port groups Port ranges per port group: 1–4, 5–8, 9–12, 13–16 Port connector type SC or CX4 depending on the type of X2 transceiver installed in the module port. Cabling distance Depends on the X2 transceiver installed in the module port. For X2 transceivers currently supported, refer to the compatibility matrices at the following URL: http://www.cisco.com/en/US/products/hw/modules/ps5455/products_ device_support_tables_list.html For cabling distance information, refer to the transceiver installation guides at the following URL: http://www.cisco.com/en/US/products/hw/modules/ps5455/prod_insta llation_guides_list.html Buffer size Oversubscription mode—90 MB per port group Performance mode—200 MB per port 186704
2-103 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules QoSNumber of egress queues: 8 Number of ingress queues: 8 Number of thresholds per egress queue: 2 per queue in oversubscription mode or 4 per queue in performance mode Number of thresholds per ingress queue: 4 Maximum frame size Up to 9216 bytes Module oversubscription rate 4:1 Supervisor engine support WS-X6716-10GE supported on the following supervisor engines: –Supervisor Engine 720 –Supervisor Engine 720-10GE –Supervisor Engine 2T (module must be upgraded with either a DFC4-E or DFC4-EXL daughter card) WS-X6816-10G-2T/-2TXL supported on the following supervisor engines: –Supervisor Engine 2T-10GE Software support WS-X6716-10GE –With Supervisor Engine 720—12.2(33)SXH2 –With Supervisor Engine 720-10GE—12.2(33)SXH2 –With Supervisor Engine 2T (module upgraded with DFC4-E or DFC4-EXL)—12.2(50)SY WS-X6816-10G-2T/-2TXL –With Supervisor Engine 2T-10GE—12.2(50)SY Queues per port Oversubscription mode: –Tx—1p7q4t per port group –Rx—1p7q2t per port Performance mode: –Tx—1p7q4t per port –Rx—8q4t per port Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued) Feature Description
2-104 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules Chassis/slot restrictionsNot supported in the Catalyst 6503 chassis. Supported only in slots 9–13 in the Catalyst 6513 chassis and does not power up in slots 1–8. When the WS-X6716-10G module is installed in a Catalyst 6500 E-series chassis or a Catalyst 6509-NEB-A chassis, the configuration is NEBS 3 compliant (chassis supports operating temperatures up to 55°C). When the WS-X6716-10G module is installed in a Catalyst 6500 non-E series chassis that is equipped with a fan tray 2 and a 2500 W or larger power supply, the configuration is not NEBS 3 compliant (chassis supports operating temperatures up to 40°C only). Support in the Catalyst 6509-NEB-A chassis requires two FAN-MOD-09 fan trays. WS-X6816-10G-2T/-2TXL is supported only in Catalyst 6500 E-series switches equipped with a Supervisor Engine 2T. Requires that modules be installed in adjacent slots or, if either adjacent slot is unused, you must install a switching-module filler plate (Cisco part numbers WS-X6K-SLOT-CVR-E or SLOTBLANK-09) rather than a blank slot cover (WS-X6K-SLOT-CVR) to maintain an adequate air flow through the chassis. Fabric connection Dual switch-fabric connections: –Fabric channel 1: Ports 1–8 –Fabric channel 2: Ports 9–16 Fabric channel speed 20 Gb/sec (dual channel, 40 Gb/sec total) Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued) Feature Description
2-105 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules Module upgrades available PoE support Not supported. Distributed forwarding support WS-X6716-10G-3C comes factory-equipped with a DFC3C daughter card. WS-X6716-10G-3CXL comes factory-equipped with a DFC3CXL daughter card. WS-X6816-10G-2T comes factory-equipped with a DFC4-E daughter card. WS-X6816-10G-2TXL comes factory-equipped with a DFC4-EXL daughter card. Pluggable transceivers supportX2 transceivers are supported. Not all types of X2 transceivers may be supported. For an up-to-date list of supported transceivers, refer to your transceiver compatibility matrices at the following URL. http://www.cisco.com/en/US/products/hw/modules/ps5455/products_ device_support_tables_list.html See the “10-GB Transceivers” section on page B-8 in Appendix B for additional information on the X2 transceivers. NoteWS-6716-10GE does not support X2 transceivers shipped prior to the release of the WS-X6708-10GE with Cisco IOS Release 12.2(18)SXF5. The unsupported X2 transceivers are labeled with a number that ends with -01. This restriction does not apply to the X2-10GB-LRM transceiver. NoteSome X2 transceivers shipped prior to the WS-X6716-10GE becoming available might not provide EMI compliance with the WS-X6716-10GE. All X2 transceivers shipped since the WS-X6716-10GE became available provide EMI compliance with the WS-X6716-10GE. See the “10-GB Transceivers” section on page B-8 in Appendix B for additional information. Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued) Feature Description
2-106 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules Digital Optical Monitoring (DOM) supportSupported on some X2 transceivers. NoteRefer to your software release notes for specific information on which X2 transceivers support DOM and the software release required for support. Module front panel LEDsSTATUS Green—All diagnostics pass; the module is operational. Orange—The module is booting or running diagnostics; an overtemperature condition has occurred. LINK Green—The port is active (the link is connected and operational). Flashing orange—The port failed diagnostics and is disabled. Orange—The port is disabled. Red—The module is resetting; an overtemperature condition has occurred. NoteIf the module fails to download code and configuration information successfully during the initial reset, the LED stays red; the module does not come online. Off—The port is not active or the link is not connected. Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued) Feature Description
2-107 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules Table 2-59 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Physical and Environmental Specifications Item Specification Dimensions 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis. Weight 13.6 lb (6.16 kg) (Excludes weight of X2 transceivers) Power and heat numbers WS-X6716-10G-3C (base module + the DFC3C daughter card)—10.9 A –Module power—457.80 W –AC-input power—572.25 W –AC heat dissipation—1954.23 BTU/hour –DC-input power—615.32 W –DC heat dissipation—2101.33 BTU/hour WS-X6716-10G-3CXL (base module + the DFC3CXL daughter card)—11.6 A –Module power—487.20 W –AC-input power—609.00 W –AC heat dissipation—2079.74 BTU/hour –DC-input power—654.84 W –DC heat dissipation—2236.27 BTU/hour WS-X6816-10G-2T (base module + the DFC4-E daughter card)—11.63 A –Module power—488.46 W –AC-input power—610.58 W –AC heat dissipation—2085.11 BTU/hour –DC-input power—656.53 W –DC heat dissipation—2242.06 BTU/hour WS-X6816-10G-2TXL (base module + the DFC4-EXL daughter card)—11.99 A –Module power—503.58 W –AC-input power—629.48 W –AC heat dissipation—2149.66 BTU/hour –DC-input power—676.85 W –DC heat dissipation—2311.46 BTU/hour
2-108 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Modules The WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet modules (Figure 2-28) provide 16 10-Gbps full- or half-duplex copper ports. Table 2-60 lists the module features, and Table 2-61 lists the module physical and environmental specifications. NoteA sticker is placed on the module faceplate identifying it as either a WS-X6816-10T-2T or WS-X6816-10T-2TXL depending on whether a WS-F6K-DFC4-E or WS-F6K-DFC4-EXL daughter card is installed on the module. Environment Operating temperature Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing)10 to 90% Operating altitude Certified for operation: 0 to 6500 ft (0 to 2000 m) Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m) Table 2-59 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Physical and Environmental Specifications (continued) Item Specification
2-109 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules Figure 2-28 WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Module Front Panel Table 2-60 WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Module Features Feature Description Ports per module 4 ports (Transparent mode): –Only port numbers 1, 5, 9, and 13 are used. 16 ports (MUX mode, 4:1 oversubscription). Ports are numbered (left to right) 4 port groups Port ranges per port group: 1–4, 5–8, 9–12, 13–16 Port connector type RJ-45 Cabling distance Cat 6 cable—Up to 179 ft (55 m) Cat 5 cable—Up to 98 ft (30 m) Buffer size Oversubscription mode—90 MB per port group Performance mode—200 MB per port QoS Number of egress queues: 8 Number of ingress queues: 8 Number of thresholds per egress queue: 2 per queue in oversubscription mode or 4 per queue in performance mode Number of thresholds per ingress queue: 4 Maximum frame size Up to 9216 bytes 208567
2-110 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-04 Chapter 2 Ethernet Switching Modules 10-Gigabit Ethernet Modules Module oversubscription rate 4:1 Supervisor engine support The WS-X6716-10T is supported on the following supervisor engines: –Supervisor Engine 720 –Supervisor Engine 720-10GE –Supervisor Engine 2T (module must be upgraded with either a DFC4-E or DFC4-EXL daughter card) The WS-X6816-10T-2T/-2TXL is supported on the following supervisor engines –Supervisor Engine 2T Software support WS-X6716-10T –With Supervisor Engine 720—12.2(33)SXI4a or later –With Supervisor Engine 720-10GE—12.2(33)SXI4 –With Supervisor Engine 2T (module upgraded with either a DFC4-E or DFC4-EXL daughter card)—12.2(50)SY WS-X6816-10T-2T/-2TXL –With Supervisor Engine 2T—12.2(50)SY Queues per port Oversubscription mode: –Tx—1p7q4t per port group –Rx—1p7q2t per port Performance mode: –Tx—1p7q4t per port –Rx—8q4t per port Table 2-60 WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Module Features (continued) Feature Description