Home > Cisco > Ethernet Switch > Cisco 6509 E Installation Manual

Cisco 6509 E Installation Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Cisco 6509 E Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							2-101
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Table 2-57 WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Module Physical and Environmental Specifications 
    Item Specification
    Dimensions 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the 
    chassis.
    Weight 16.0 lb (7.26 kg)
    Power and heat numbers
    WS-X6708-10G-3C (base module + the DFC3C daughter card)
     –Module current—10.58 A
     –Module power—444.36 W
     –AC-input power—555.45 W
     –AC heat dissipation—1896.86 BTU/hour
     –DC-input power—597.26 W
     –DC heat dissipation—2039.64 BTU/hour
    WS-X6708-10G-3CXL (base module + the DFC3CXL daughter 
    card)
     –Module current—11.28 A
     –Module power—473.76 W
     –AC-input power—592.20 W
     –AC heat dissipation—2022.36 BTU/hour
     –DC-input power—636.77 W
     –DC heat dissipation—2174.58 BTU/hour
    Environment
    Operating temperature
    Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    Humidity (RH) ambient 
    (noncondensing)10 to 90%
    Operating altitude
    Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 
    3000 m) 
    						
    							2-102
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Modules
    The WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet modules (Figure 2-27) provide 16 
    10-Gbps full- or half-duplex ports. Table 2-58 lists the module features, and Table 2-59 lists the module 
    physical and environmental specifications. 
    NoteA sticker is placed on the module faceplate identifying it as either a WS-X6816-10G-2T or 
    WS-X6816-10G-2TXL depending on whether a WS-F6K-DFC4-E or WS-F6K-DFC4-EXL daughter 
    card is installed on the module.
    Figure 2-27 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Front Panel
    Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features 
    Feature Description
    Ports per module
    16 ports. Ports are numbered (left to right):
     –Top row, odd numbered ports 1 through 15.
     –Bottom row, even numbered ports 2 through 16.
    4 port groups
    Port ranges per port group: 1–4, 5–8, 9–12, 13–16
    Port connector type SC or CX4 depending on the type of X2 transceiver installed in the 
    module port.
    Cabling distance Depends on the X2 transceiver installed in the module port. For X2 
    transceivers currently supported, refer to the compatibility matrices at 
    the following URL:
    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_
    device_support_tables_list.html
    For cabling distance information, refer to the transceiver installation 
    guides at the following URL:
    http://www.cisco.com/en/US/products/hw/modules/ps5455/prod_insta
    llation_guides_list.html
    Buffer size
    Oversubscription mode—90 MB per port group
    Performance mode—200 MB per port
    186704 
    						
    							2-103
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    QoSNumber of egress queues: 8
    Number of ingress queues: 8
    Number of thresholds per egress queue: 2 per queue in 
    oversubscription mode or 4 per queue in performance mode
    Number of thresholds per ingress queue: 4
    Maximum frame size Up to 9216 bytes
    Module oversubscription rate 4:1
    Supervisor engine support
    WS-X6716-10GE supported on the following supervisor engines:
     –Supervisor Engine 720
     –Supervisor Engine 720-10GE
     –Supervisor Engine 2T (module must be upgraded with either a 
    DFC4-E or DFC4-EXL daughter card)
    WS-X6816-10G-2T/-2TXL supported on the following supervisor 
    engines:
     –Supervisor Engine 2T-10GE
    Software support
    WS-X6716-10GE
     –With Supervisor Engine 720—12.2(33)SXH2
     –With Supervisor Engine 720-10GE—12.2(33)SXH2
     –With Supervisor Engine 2T (module upgraded with DFC4-E 
    or DFC4-EXL)—12.2(50)SY
    WS-X6816-10G-2T/-2TXL
     –With Supervisor Engine 2T-10GE—12.2(50)SY
    Queues per port
    Oversubscription mode: 
     –Tx—1p7q4t per port group
     –Rx—1p7q2t per port
    Performance mode:
     –Tx—1p7q4t per port
     –Rx—8q4t per port
    Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued)
    Feature Description 
    						
    							2-104
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Chassis/slot restrictionsNot supported in the Catalyst 6503 chassis. 
    Supported only in slots 9–13 in the Catalyst 6513 chassis and does 
    not power up in slots 1–8. 
    When the WS-X6716-10G module is installed in a Catalyst 6500 
    E-series chassis or a Catalyst 6509-NEB-A chassis, the 
    configuration is NEBS 3 compliant (chassis supports operating 
    temperatures up to 55°C). 
    When the WS-X6716-10G module is installed in a Catalyst 6500 
    non-E series chassis that is equipped with a fan tray 2 and a 
    2500 W or larger power supply, the configuration is not NEBS 3 
    compliant (chassis supports operating temperatures up to 40°C 
    only).
    Support in the Catalyst 6509-NEB-A chassis requires two 
    FAN-MOD-09 fan trays.
    WS-X6816-10G-2T/-2TXL is supported only in Catalyst 6500 
    E-series switches equipped with a Supervisor Engine 2T.
    Requires that modules be installed in adjacent slots or, if either 
    adjacent slot is unused, you must install a switching-module filler 
    plate (Cisco part numbers WS-X6K-SLOT-CVR-E or 
    SLOTBLANK-09) rather than a blank slot cover 
    (WS-X6K-SLOT-CVR) to maintain an adequate air flow through 
    the chassis.
    Fabric connection
    Dual switch-fabric connections:
     –Fabric channel 1: Ports 1–8
     –Fabric channel 2: Ports 9–16
    Fabric channel speed 20 Gb/sec (dual channel, 40 Gb/sec total)
    Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued)
    Feature Description 
    						
    							2-105
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Module upgrades available
    PoE support Not supported.
    Distributed forwarding 
    support
    WS-X6716-10G-3C comes factory-equipped with a DFC3C 
    daughter card.
    WS-X6716-10G-3CXL comes factory-equipped with a DFC3CXL 
    daughter card.
    WS-X6816-10G-2T comes factory-equipped with a DFC4-E 
    daughter card.
    WS-X6816-10G-2TXL comes factory-equipped with a DFC4-EXL 
    daughter card.
    Pluggable transceivers 
    supportX2 transceivers are supported. Not all types of X2 transceivers may be 
    supported. For an up-to-date list of supported transceivers, refer to your 
    transceiver compatibility matrices at the following URL.
    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_
    device_support_tables_list.html
    See the “10-GB Transceivers” section on page B-8 in Appendix B for 
    additional information on the X2 transceivers.
    NoteWS-6716-10GE does not support X2 transceivers shipped prior 
    to the release of the WS-X6708-10GE with Cisco IOS 
    Release 12.2(18)SXF5. The unsupported X2 transceivers are 
    labeled with a number that ends with -01. This restriction does 
    not apply to the X2-10GB-LRM transceiver.
    NoteSome X2 transceivers shipped prior to the WS-X6716-10GE 
    becoming available might not provide EMI compliance with the 
    WS-X6716-10GE. All X2 transceivers shipped since the 
    WS-X6716-10GE became available provide EMI compliance 
    with the WS-X6716-10GE. See the “10-GB Transceivers” 
    section on page B-8 in Appendix B for additional information.
    Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued)
    Feature Description 
    						
    							2-106
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Digital Optical Monitoring 
    (DOM) supportSupported on some X2 transceivers.
    NoteRefer to your software release notes for specific information on 
    which X2 transceivers support DOM and the software release 
    required for support.
    Module front panel LEDsSTATUS
    Green—All diagnostics pass; the module is operational.
    Orange—The module is booting or running diagnostics; an 
    overtemperature condition has occurred.
    LINK
    Green—The port is active (the link is connected and operational).
    Flashing orange—The port failed diagnostics and is disabled.
    Orange—The port is disabled.
    Red—The module is resetting; an overtemperature condition has 
    occurred. 
    NoteIf the module fails to download code and configuration 
    information successfully during the initial reset, the LED stays 
    red; the module does not come online.
    Off—The port is not active or the link is not connected.
    Table 2-58 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Features (continued)
    Feature Description 
    						
    							2-107
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Table 2-59 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Physical and Environmental 
    Specifications 
    Item Specification
    Dimensions 1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the 
    chassis.
    Weight 13.6 lb (6.16 kg) (Excludes weight of X2 transceivers)
    Power and heat numbers
    WS-X6716-10G-3C (base module + the DFC3C daughter 
    card)—10.9 A
     –Module power—457.80 W
     –AC-input power—572.25 W
     –AC heat dissipation—1954.23 BTU/hour
     –DC-input power—615.32 W
     –DC heat dissipation—2101.33 BTU/hour
    WS-X6716-10G-3CXL (base module + the DFC3CXL daughter 
    card)—11.6 A
     –Module power—487.20 W
     –AC-input power—609.00 W
     –AC heat dissipation—2079.74 BTU/hour
     –DC-input power—654.84 W
     –DC heat dissipation—2236.27 BTU/hour
    WS-X6816-10G-2T (base module + the DFC4-E daughter 
    card)—11.63 A
     –Module power—488.46 W
     –AC-input power—610.58 W
     –AC heat dissipation—2085.11 BTU/hour
     –DC-input power—656.53 W
     –DC heat dissipation—2242.06 BTU/hour
    WS-X6816-10G-2TXL (base module + the DFC4-EXL daughter 
    card)—11.99 A
     –Module power—503.58 W
     –AC-input power—629.48 W
     –AC heat dissipation—2149.66 BTU/hour
     –DC-input power—676.85 W
     –DC heat dissipation—2311.46 BTU/hour 
    						
    							2-108
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Modules
    The WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet modules (Figure 2-28) provide 16 
    10-Gbps full- or half-duplex copper ports. Table 2-60 lists the module features, and Table 2-61 lists the 
    module physical and environmental specifications. 
    NoteA sticker is placed on the module faceplate identifying it as either a WS-X6816-10T-2T or 
    WS-X6816-10T-2TXL depending on whether a WS-F6K-DFC4-E or WS-F6K-DFC4-EXL daughter 
    card is installed on the module. Environment
    Operating temperature
    Certified for operation: 32° to 104°F (0° to 40°C)
    Designed and tested for operation: 32° to 130°F (0° to 55°C)
    Humidity (RH) ambient 
    (noncondensing)10 to 90%
    Operating altitude
    Certified for operation: 0 to 6500 ft (0 to 2000 m)
    Designed and tested for operation: –200 to 10,000 ft (–60 to 
    3000 m)
    Table 2-59 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Module Physical and Environmental Specifications 
    (continued)
    Item Specification 
    						
    							2-109
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Figure 2-28 WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Module Front Panel
    Table 2-60 WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Module Features 
    Feature Description
    Ports per module
    4 ports (Transparent mode):
     –Only port numbers 1, 5, 9, and 13 are used.
    16 ports (MUX mode, 4:1 oversubscription). Ports are numbered 
    (left to right)
    4 port groups
    Port ranges per port group: 1–4, 5–8, 9–12, 13–16
    Port connector type RJ-45
    Cabling distance Cat 6 cable—Up to 179 ft (55 m)
    Cat 5 cable—Up to 98 ft (30 m)
    Buffer size
    Oversubscription mode—90 MB per port group
    Performance mode—200 MB per port
    QoS
    Number of egress queues: 8
    Number of ingress queues: 8
    Number of thresholds per egress queue: 2 per queue in 
    oversubscription mode or 4 per queue in performance mode
    Number of thresholds per ingress queue: 4
    Maximum frame size Up to 9216 bytes
    208567 
    						
    							2-110
    Catalyst 6500 Series Ethernet Modules Installation Guide
    OL-6265-04
    Chapter 2      Ethernet Switching Modules
      10-Gigabit Ethernet Modules
    Module oversubscription rate 4:1
    Supervisor engine support
    The WS-X6716-10T is supported on the following supervisor 
    engines:
     –Supervisor Engine 720
     –Supervisor Engine 720-10GE
     –Supervisor Engine 2T (module must be upgraded with either a 
    DFC4-E or DFC4-EXL daughter card)
    The WS-X6816-10T-2T/-2TXL is supported on the following 
    supervisor engines
     –Supervisor Engine 2T
    Software support
    WS-X6716-10T
     –With Supervisor Engine 720—12.2(33)SXI4a or later
     –With Supervisor Engine 720-10GE—12.2(33)SXI4
     –With Supervisor Engine 2T (module upgraded with either a 
    DFC4-E or DFC4-EXL daughter card)—12.2(50)SY
    WS-X6816-10T-2T/-2TXL
     –With Supervisor Engine 2T—12.2(50)SY
    Queues per port
    Oversubscription mode: 
     –Tx—1p7q4t per port group
     –Rx—1p7q2t per port
    Performance mode:
     –Tx—1p7q4t per port
     –Rx—8q4t per port
    Table 2-60 WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Module Features (continued)
    Feature Description 
    						
    All Cisco manuals Comments (0)